Download

7.5W DC-DC Converter P8Y90S05HD
●
●
●
●
2:1 Wide input voltage range
Five-sided shield
Standard 1" x 2" x 0.41" package
Fixed switching frequency
Model selection guide
Typ
Input nominal voltage
[VDC]
Single Output
P8Y90S05HD
40…140
Output voltage
[VDC]
Output current
[mA]
5.0
Efficiency typ.
[%]
1500
78
Specifications
Input
Voltage range
Filter (see note 1)
Output
Output Power
Voltage accuracy full
load and nominal Vin
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Transient response,
25% step load change
Line voltage regulation
LL to HL at Full Load
Load voltage regulation
Full load at 25% of full load
Temperature coefficient
Minimum load
Over voltage protection
40 to 140VDC
Pi type
7.5 W max.
±2%
50mVp-p
Continuous
400µs
100mV max.
±0.1%
±0.2%
General
Switching frequency
Environmental
Operating temperature
Storage temperature range
Cooling
Physical
Dimensions
Weight
Case material
Isolation
Rated voltage
Resistance
Capacitance
EMC
± 0.02% / °C, max
10% of full load
5.6 to 6Vdc
220 kHz, typ.
-25°C to +71°C
-40 °C to +125 °C
Free-air convection
50.8 x 25.4 x 10.2 mm
20 g
Nickel-coated copper
1500 VDC, min
9
10 Ω, min.
1000pF, max
In accordance with
EN55022 class B
Note1: An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A ripple current.
Example: 220µF/ 100V, ESR <90mΩ.
Pin connections
Pin
1
2
3
4
5
Dimensions
Triple
+ Input
- Input
+ Output
Omitted
- Output
Life Support Policy: HY-LINE does not
authorize the use of any of its products
for use in life support devices or systems
without the express written approval of
an officer of the Company. Life support
systems are devices which support or
sustain life, and whose failure to perform,
when properly used in accordance with
instructions for use provided in the
labeling, can be reasonably expected to
result in significant injury to the user.
Rev: 05 / 05 f
1.
2.
All dimensions in mm
Pin pitch tolerance ±0.35
Page 1 of 1
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]