6W DC-DC Converter P6X-Series ● ● ● ● ● ● 6 W maximum output power Adjustable Output Voltage 2:1 wide input voltage range Five-Sided continuous shield Small package 1.6" x 1" x 0.33" Short circuit protection Model selection guide Typ Input nominal Input current voltage full-load [VDC] [mA] Single output P6X05S33 4.5…9 1131 P6X05S05 4.5…9 1370 P6X05S12 4.5…9 1519 P6X12S33 9…18 573 P6X12S05 9…18 658 P6X12S12 9…18 617 P6X24S33 18…36 286 P6X24S05 18…36 321 P6X24S12 18…36 309 P6X48S33 36...75 143 P6X48S05 36...75 165 P6X48S12 36...75 155 Dual output P6X05D12 4.5…9 1519 P6X12D12 9…18 617 P6X24D12 18…36 309 P6X48D12 36...75 155 Trimming Output voltage [VDC] Output current [mA] Efficiency typ. [%] Capacitor load max. [uF] 3.3 5.0 12.0 3.3 5.0 12.0 3.3 5.0 12.0 3.3 5.0 12.0 1200 1000 500 1200 1000 500 1200 1000 500 1200 1000 500 74 77 83 76 80 85 77 82 85 77 80 85 6600 3000 1400 6600 3000 1400 6600 3000 1400 6600 3000 1400 ±12.0 ±12.0 ±12.0 ±12.0 ±250 ±250 ±250 ±250 83 85 85 85 2 x 510 2 x 510 2 x 510 2 x 510 Remote Control Output can be externally trimmed by using the method shown below. ( ) for dual output 5 (4) TRIM UP 6 (6) TRIM DOWN 7 (7) Page 1 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 6W DC-DC Converter P6X-Series Specifications Input Voltage range Filter EMC external filter capacitor for EN55022 class A Input surge voltage for 100mS max. Output Power Voltage accuracy Minimum load Line regulation Load voltage regulation Ripple and noise (at 50 MHz BW) Transient response recovery time Short circuit protection Voltage adjustability Over current protection Temperature coefficient 5V type: 4.5…9 VDC 12V type: 9…18 VDC 24V type: 18…36 VDC 48V type: 36…75 VDC L-C type 5V type: 220 µF / 16 VDC 12V type: 220 µF / 25 VDC 24V type: 100 µF / 50 VDC 48V type: 100 µF / 100 VDC 5V type : 15 VDC max. 12V type : 36 VDC max. 24V type : 50 VDC max. 48V type : 100 VDC max. 6 W max. ± 2% 0% ± 0.2% ± 0.5% between 10% and 100% load 100mVp-p max. 500 µs / 25% load step change continuous, automatics recovery ± 10% 150% ± 0.02% / °C General Efficiency Switching frequency Isolation voltage Isolation Resistance Isolation Capacitance Safety standards in accordance with MTBF Bellcore TR-NWT-000332 Environmental Operating temperature Storage temperature Thermal shock Cooling Vibration Relative humidity operating and storage Physical Dimensions Weight Base material Case material Dimensions See table 100 to 1500 kHz 500 VAC 6 50 Ω @ 500 V 300 pF, max. IEC60950, UL60950, EN60950 @Ta 40 °C, 100% stress: 6 1.5x10 hrs -20 °C to +70 °C (with derating) -40 °C to +85 °C MIL-STD-810D Nature convection 10..55..10 Hz, sweep15 minutes, amplitude 1.5 mm, max. 9 G X,Y, Z 2 hrs each axis 20% to 95% RH 1.6 x 1 x 0.33 inches 41 x 25.8 x 8.5 mm 20 g None Metal Derating All dimensions in inches (mm) Pin Pitch tolerance ±0.014 (0.35) Pin connections Pin 1 2 3 4 5 6 7 Single + Input CTRL - Input N.C. - Output Trim + Output Dual + Input CTRL - Input Common - Output Trim + Output Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 02 / 2008 f Page 2 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]