AN42 Digital indicators

AN42 Digital indicators
20.000 counts LED display
4-20 mA or 0-10V input
Keyboard configuration or by USB terminal
2 alarm switches – form C relays
4-20mA or 0-10V analog isolated output
Wide universal power supply
Meet the toughest requirements of electromagnetic compatibility standards EN 50081 and EN 50082 (European directive :
89/336/CEE).
The AN42 is a process panel meter for 4-20mA or 0-10V input,
programmable with capability of transmitter supply, 2 alarm
switches and a 4-20mA or 0-10V analog isolated output. The device
configuration is done easily either by the front panel keyboard or by
a USB terminal. This configuration can be locked. Filter function can
be selected to smooth a signal, modulo function can in some cases
give a comfortable display using always the best specifications of the
instrument. The AN42 is features 2 alarm switches programmable
on value, delay, hysteresis, switching status and separation for LED
status. The AN42 is a panel mounting meter, 20000 count 14mm LED
with wiring on removable screwon
terminal blocks.
Specifications (20 °C)
Display
-19999 to +19999 counts red LED
programmable decimal point
Overflow : display dEP. or dEP
Reading rate 10 measurements/second
Operating temperature
0 ... 50°C
Storage temperature
-40 ... 85°C
Current
4-20mA or voltage 1V or 10V
Input and display programmable by front panel
keyboard or by USB terminal
Transmitter supply
20 V
permanent short-circuit max 23mA
Current input shunt value : ~75 Ω
Voltage input impedance 100M Ω
Accuracy
Full scale 0.15% - zero 0.1%
Repeatability
0.1% - Thermal drift 100ppm/°C
Default value > 21mA or 10,5V
Thermal drift
Max. 100ppm/°C
Alarms
2 independent alarm switches programmable
on value, delay, hysteresis, relay status and
separation for LED status. LED alarm status on
front panel. 2 relays form C - 1A 220V cos ø0,7
Analog isolated output
4-20 mA active 1-10V, 4-20 mA passive.
Isolation voltage input/output : 500 Veff
Output load 400 Ω (8V) max current 22mA
Power supply
Wide universal 24 to 250Vac and 22 to
140Vdc -Consumption 3,5VA
Case
Noryl UL94V0 case (panel mounting)
Protection
Front panel waterproof IP54
Electric connector
Wiring on removable screw-on terminal blocks
www.baumer.com/process
Modifications reserved.
Options
Calibration with certificate Q1060
Data sheet D21.02
Page 1
Dimensions (mm)
Analog isolated output wiring Cn4 terminal
SA2 0-10V
SA3 active 4-20mA
SA4 passive 4-20mA
Alarmes wiring
Alarm switches are available on terminal Cn3
Power supply wiring
Primary supply is connected on terminal Cn1
Input terminal wiring Cn2
Supplying a 4-20mA
transmitter 4-20mA loop receiver
1V or 10V voltage input
UK/02-2008 This data sheet must only be copied in full.
Dimensions (mm)
Panel cut out
500 g
kg
Ordering Details - AN42
AN4xxxx
Family
Accessories electronic
1´ digit
A
Type
Digital indicator with tresholds
2 ... 4´ digit
Power supply
0-10 Vcc (standard)
4-20 mA active
4-20 mA passive
5 ... 6´ digit
N 42
02
03
04
Tresholds
2 Tresholds
7´ digit
Transmitter with indicator calibrated together
Without
Phisical unit display (to specifybar, psi, daN)
End points calibration (zero and span)
Q1060 calibration certificate 21 points
Q1060 calibration certificate 11 points
8´ digit
www.baumer.com/process
Modifications reserved.
2
0
1
2
3
5
Data sheet D21.02