12W DC-DC Converter P12B-Series ● ● ● ● ● ● ● Wide 4:1 input range Efficiency up to 85 % 1500 VDC isolation Continuous short circuit protection Standard package 2” x 1” x 0.4” MTBF 1.12 M hours Wide Operating Temperature Range -40..+85°C Model selection guide Typ Single output P12B243R3S P12B2405S P12B2412S P12B2415S P12B483R3S P12B4805S P12B4812S P12B4815S Dual output P12B2405D P12B2412D P12B2415D P12B4805D P12B4812D P12B4815D Input nominal Input voltage quiescent [VDC] current [mA] Output voltage Output current [VDC] [mA] Efficiency typ. capacitive load [%] [µF] 9...36 9...36 9...36 9...36 18...72 18...72 18...72 18...72 25 25 25 25 20 20 20 20 3.3 5.0 12.0 15.0 3.3 5.0 12.0 15.0 2400 2400 1000 800 2400 2400 1000 800 80 82 85 85 80 82 85 85 3300 3300 680 470 3300 3300 680 470 9...36 9...36 9...36 18...72 18...72 18...72 25 25 25 20 20 20 ±5.0 ±12.0 ±15.0 ±5.0 ±12.0 ±15.0 ±1200 ±500 ±400 ±1200 ±500 ±400 82 85 85 82 85 85 2 x 2200 2 x 470 2 x 330 2 x 2200 2 x 470 2 x 330 Page 1 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 12W DC-DC Converter P12B-Series Specifications Input Voltage range Filter Remote control pin 6 Input current:-2,5 mA Isolation Voltage: Input to Output Input/Output to Case Resistance Capacitance Output Voltage accuracy Load voltage regulation Line voltage regulation Over current protection Short circuit protection Short circuit restart Ripple and noise (at 20 MHz BW) Temperature coefficient 24 VDC, 9…36 VDC 48 VDC, 18…72 VDC Capacitors on: pin open or 2.5...5.5V off: pin to gnd or 0.7...0.8V 1,5 kVDC for 1 min., test 1s 1000 VDC for 1 min. 109 Ω 1200 pF, typ. ± 1% ± 0.5%, at 10..100% load ± 0.5%, max. 140% of max. Iout Continuous Automatic 75 mVp-p, max. ± 0.02% / °C General Switching frequency Safety standard in accordance with Environmental Operating temperatur (ambient) Case temperature Storage temperature Humidity 300 kHz, typ. IEC60950-1 : 2001 -40 °C ... +85 °C 100 °C, max. -40 °C to +125 °C Up to 95%, non-condensing Free-air convection Cooling Physical Dimensions Weight Case material Potting material Pin material Soldering temperature 1.5mm distance from case 50.80 x 25.40 x 10.16 mm 30.0 g Nickel-coated copper Epoxy (UL94V-0 rated) Brass solder coated 260°C for 10s Dimensions COM / no Pin COM / no Pin Output ripple and noise reduction + DC Power Source - +input +output DC/DC Converter -input Scope Load To reduce ripple and noise, it is recommended to use 4.7µF capacitors to the output -output Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 2 / 07f Page 2 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]