Download

12W DC-DC Converter P12B-Series
●
●
●
●
●
●
●
Wide 4:1 input range
Efficiency up to 85 %
1500 VDC isolation
Continuous short circuit protection
Standard package 2” x 1” x 0.4”
MTBF 1.12 M hours
Wide Operating Temperature Range -40..+85°C
Model selection guide
Typ
Single output
P12B243R3S
P12B2405S
P12B2412S
P12B2415S
P12B483R3S
P12B4805S
P12B4812S
P12B4815S
Dual output
P12B2405D
P12B2412D
P12B2415D
P12B4805D
P12B4812D
P12B4815D
Input nominal Input
voltage
quiescent
[VDC]
current
[mA]
Output
voltage
Output
current
[VDC]
[mA]
Efficiency typ. capacitive
load
[%]
[µF]
9...36
9...36
9...36
9...36
18...72
18...72
18...72
18...72
25
25
25
25
20
20
20
20
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
2400
2400
1000
800
2400
2400
1000
800
80
82
85
85
80
82
85
85
3300
3300
680
470
3300
3300
680
470
9...36
9...36
9...36
18...72
18...72
18...72
25
25
25
20
20
20
±5.0
±12.0
±15.0
±5.0
±12.0
±15.0
±1200
±500
±400
±1200
±500
±400
82
85
85
82
85
85
2 x 2200
2 x 470
2 x 330
2 x 2200
2 x 470
2 x 330
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
12W DC-DC Converter P12B-Series
Specifications
Input
Voltage range
Filter
Remote control pin 6
Input current:-2,5 mA
Isolation Voltage:
Input to Output
Input/Output to Case
Resistance
Capacitance
Output
Voltage accuracy
Load voltage regulation
Line voltage regulation
Over current protection
Short circuit protection
Short circuit restart
Ripple and noise
(at 20 MHz BW)
Temperature coefficient
24 VDC, 9…36 VDC
48 VDC, 18…72 VDC
Capacitors
on: pin open or 2.5...5.5V
off: pin to gnd or 0.7...0.8V
1,5 kVDC for 1 min., test 1s
1000 VDC for 1 min.
109 Ω
1200 pF, typ.
± 1%
± 0.5%, at 10..100% load
± 0.5%, max.
140% of max. Iout
Continuous
Automatic
75 mVp-p, max.
± 0.02% / °C
General
Switching frequency
Safety standard in
accordance with
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Humidity
300 kHz, typ.
IEC60950-1 : 2001
-40 °C ... +85 °C
100 °C, max.
-40 °C to +125 °C
Up to 95%,
non-condensing
Free-air convection
Cooling
Physical
Dimensions
Weight
Case material
Potting material
Pin material
Soldering temperature
1.5mm distance from case
50.80 x 25.40 x 10.16 mm
30.0 g
Nickel-coated copper
Epoxy (UL94V-0 rated)
Brass solder coated
260°C for 10s
Dimensions
COM /
no Pin
COM /
no Pin
Output ripple and noise reduction
+
DC Power
Source
-
+input
+output
DC/DC Converter
-input
Scope
Load
To reduce ripple and noise, it is recommended to use
4.7µF capacitors to the output
-output
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems
without the express written approval of an officer of the Company. Life support systems are devices which support or
sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the
labeling, can be reasonably expected to result in significant injury to the user.
Rev: 2 / 07f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]