Download

500mA DC-DC Step Down Converter P78A-Series
●
●
●
●
●
●
●
Non Isolated
3 Pin SIL
Pin compatible with 78Mxx linear regulator
Efficiency up to 97 %
Operating temperature range -40...+85 °C
Wide Input Range
Continuous short circuit protected
Model guide
Typ
P78A1R5
P78A1R8
P78A2R5
P78A3R3
P78A05
P78A6R5
P78A7R2
P78A09
P78A12
P78A15
Input
nominal
voltage
[VDC]
4.75...30
4.75...34
4.75...34
4.75...34
6.5...34
8...34
9...34
11...34
15...34
18...34
No-load
[mA]
8
8
8
8
8
8
8
8
8
8
Input current
Full load
@ Vin min. @ Vin max.
[mA]
[mA]
200
37
230
38
300
48
380
60
410
86
425
108
420
118
425
144
412
188
430
232
Specifications
Input
Input reflected ripple current
@source induct. 12 µH (*3)
Filter
Output
Voltage accuracy
Input voltage regulation
Load regulation
Short circuit protection
Ripple and noise (*1)
Temperature coefficient
Minimum load (*7)
General
Switching frequency
Reliability calculated MTBF
EMC Characteristics
ESD
RS
EFT (*5)
CS
PFMF
Output
Current
[VDC]
1.5
1.8
2.5
3.3
5.0
6.5
7.2
9.0
12.0
15.0
[mA]
500
500
500
500
500
500
500
500
500
500
Capacitive
load max.
[µF] (*2)
220
220
220
220
220
220
220
220
220
220
EMC Characteristics
Radiated emissions
Conducted emissions (*4)
Environmental
Operating temperature amb.
Case temperature
Storage temperature
Derating
Humidity
35 mA p-p
Capacitors
± 2 %, max.
± 0.5 %
± 0.6 % @ load 10..100%
not limited,
automatic recovery
60 mVp-p, max.
± 0.02% / °C
50 mA
Cooling
Physical
Dimensions
Weight
Case material
330 kHz, typ.
>4.5 Mio. h
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
EN 61000-4-8
Voltage
Perf. Crit. A
Perf. Crit. A
Perf. Crit. A
Perf. Crit. A
Perf. Crit. A
EN55022
EN55022
Efficiency
@ Vin
@ Vin
min.
max.
[%]
[%]
78
65
82
70
87
76
91
81
94
85
95
88
95
89
96
92
97
94
97
95
class B
class B
-40 °C ... +85 °C
100 °C, max.
-40 °C ... +125 °C
see diagram
Up to 95%,
non-condensing
nature convection
11.68 x 7.5 x 10.16 mm
1.8 g
Non-conductive black plastic,
UL94V-0
Potting material
Epoxy UL94V-0
Absolut maximum ratings (*6)
Input voltage range
0...34 VDC, 0.1 s max.
260 °C for 10s
Soldering temperature 1,5
mm distance from case
Note:
1. Ripple & Noise measured with 20 MHz bandwidth. Load condition: 10% ~ 100%, output noise arise when load is under 10%.
2. Tested by minimal Vin and constant resistive load.
3. Measured input reflected ripple current with a simulated source inductance of 12 µH.
4. Input filter components (C1, C2, L) are used to help meet conducted emissions requirement for the module. These components
should be mounted as close as possible to the module; and all leads should be minimized to decrease radiated noise.
5. An external filter capacitor is required if the module has to meet EN61000-4-4.
Recommended filter capacitor: Nippon Chemicon KY series, 470 µF / 100V.
6. Do not operate the units exceeding the absolute maximum rating, over rating causes damage to the units.
7. Operation under no-load conditions will not damage these devices, however they may not meet all listed specifications.
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
500mA DC-DC Step Down Converter P78A-Series
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
500mA DC-DC Step Down Converter P78A-Series
Dimensions
11.68
9.65
7.5
PHI-CON
P78A05
0.5
1
2
3
4.1
2.54
0.5
2.0
0.5
All dimensions in mm
Pitch tolerance ±0.35 mm
Pin tolerance ±0.05 mm
Package tolerance ±0.5mm
0.25
Pin connections
Pin
1
2
3
Connections
+V Input
GND
+V Output
PHI-CON is a trademark of HY-LINE Power Components.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected
to result in significant injury to the user. Rev: 5.13 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]