15W DC-DC Converter P15E-Series ● ● ● ● ● ● ● ● Wide 4:1 input range Efficiency up to 86 % 1500 VDC isolation Continuous short circuit protection Standard package 2” x 1” x 0.4” MTBF 1.12 M hours Wide Operating Temperature Range -40..+85°C On/Off Remote Control optional Model selection guide Typ Input nominal voltage Input quiescent current [mA] Output voltage [VDC] [VDC] Single output P15E243R3S 9...36 25 3.3 P15E2405S 9...36 25 5.0 P15E2412S 9...36 25 12.0 P15E2415S 9...36 25 15.0 P15E483R3S 18...72 20 3.3 P15E4805S 18...72 20 5.0 P15E4812S 18...72 20 12.0 P15E4815S 18...72 20 15.0 Dual output P15E2405D 9...36 25 ±5.0 P15E2412D 9...36 25 ±12.0 P15E2415D 9...36 25 ±15.0 P15E4805D 18...72 20 ±5.0 P15E4812D 18...72 20 ±12.0 P15E4815D 18...72 20 ±15.0 Ordering information: add suffix “C” for remote control option Output current Efficiency typ. capacitive load [mA] [%] [µF] 3000 3000 1250 1000 3000 3000 1250 1000 80 83 85 86 80 83 85 86 3300 3300 680 470 3300 3300 680 470 ±1500 ±625 ±500 ±1500 ±625 ±500 83 85 86 83 85 86 2 x 2200 2 x 470 2 x 330 2 x 2200 2 x 470 2 x 330 Page 1 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 15W DC-DC Converter P15E-Series Specifications Input Voltage range Filter Remote control pin 6 Input current:-2,5 mA Isolation Voltage: Input to Output Input/Output to Case Resistance Capacitance Output Voltage accuracy Load voltage regulation Line voltage regulation Over current protection Short circuit protection Short circuit restart Ripple and noise (at 20 MHz BW) Temperature coefficient General Switching frequency Safety standard compliant with Environmental Operating temperatur (ambient) Case temperature Storage temperature Humidity 24 VDC, 9…36 VDC 48 VDC, 18…72 VDC Capacitors on: pin open or 2.5...5.5 V off: pin to gnd or 0.7...0.8 V 1,5 kVDC for 1 min., test 1 s 1000 VDC for 1 min. 9 10 Ω 1200 pF, typ. 300 kHz, typ. IEC60950-1 : 2001 -40 °C to +85 °C 100 °C, max. -40 °C to +125 °C Up to 95 %, non-condensing Free-air convection Cooling Physical Dimensions Weight Case material Potting material Pin material Absolute maximum ratings Soldering temperature 1.5mm distance from case Input voltage for max. 100 ms 24 V input types 48 V input types ±1% ± 0.5 %, at 10..100 % load ± 0.5 %, max. 140 % of max. Iout Continuous Automatic 75 mVp-p, max. ± 0.02% / °C 50.80 x 25.40 x 10.16 mm 30.0 g Nickel-coated copper Epoxy (UL94V-0 rated) Brass solder coated 260 °C for 10 s -0.7...40 V -0.7...80 V Input reflected ripple current measure circuit The input reflected ripple current is measured through a source inductor 12 µH and a source capacitor Cin 47 µF, ESR<1 ohm at 100 kHz at nominal input voltage and full load. + Input Measure Point L: 12 µH 1 3 +Vin 47µF 33µF ESR <1Ω @ 100kHz +Vout Current Probe DC/DC – Converter Resistive load 2 5 -Vin -Vout - Input Output ripple & noise reduction To reduce ripple and noise, it is recommended to use a 1µF ceramic disk and a 10 µF electrolytic capacitor. + Input 1 4 +Vin +Vout 10µF 1µF 10µF Load DC/DC – Converter 2 5 -Vin -Vout - Input On / Off Control Positive logic turns ON the module during high logic and Off during low logic. CTRL function can be controlled by an external switch between the CRTL terminal and –Vin terminal. The switch can be an open collector or open drain for positive logic. If the CTRL feature is not used then do not connect the CTRL pin. + Input 1 +Vin +Vout ON Remote Control OFF OFF CTRL DC/DC – Converter 3 ON - Input -Vin -Vout 2 Page 2of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 15W DC-DC Converter P15E-Series Dimensions COM / no Pin COM / no Pin Pin 1 2 3 4 5 6 Standard version Single output + V input - V input + V output No pin - V output No pin Dual output + V input - V input + V output Common - V output No pin Version with remote control input option Single output Dual output + V input + V input - V input - V input + V output + V output No pin Common - V output - V output Remote control Remote control Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 11 / 11f Page 3 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]