Download

15W DC-DC Converter P15E-Series
●
●
●
●
●
●
●
●
Wide 4:1 input range
Efficiency up to 86 %
1500 VDC isolation
Continuous short circuit protection
Standard package 2” x 1” x 0.4”
MTBF 1.12 M hours
Wide Operating Temperature Range -40..+85°C
On/Off Remote Control optional
Model selection guide
Typ
Input nominal
voltage
Input
quiescent
current
[mA]
Output
voltage
[VDC]
[VDC]
Single output
P15E243R3S
9...36
25
3.3
P15E2405S
9...36
25
5.0
P15E2412S
9...36
25
12.0
P15E2415S
9...36
25
15.0
P15E483R3S
18...72
20
3.3
P15E4805S
18...72
20
5.0
P15E4812S
18...72
20
12.0
P15E4815S
18...72
20
15.0
Dual output
P15E2405D
9...36
25
±5.0
P15E2412D
9...36
25
±12.0
P15E2415D
9...36
25
±15.0
P15E4805D
18...72
20
±5.0
P15E4812D
18...72
20
±12.0
P15E4815D
18...72
20
±15.0
Ordering information: add suffix “C” for remote control option
Output
current
Efficiency typ.
capacitive
load
[mA]
[%]
[µF]
3000
3000
1250
1000
3000
3000
1250
1000
80
83
85
86
80
83
85
86
3300
3300
680
470
3300
3300
680
470
±1500
±625
±500
±1500
±625
±500
83
85
86
83
85
86
2 x 2200
2 x 470
2 x 330
2 x 2200
2 x 470
2 x 330
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
15W DC-DC Converter P15E-Series
Specifications
Input
Voltage range
Filter
Remote control pin 6
Input current:-2,5 mA
Isolation Voltage:
Input to Output
Input/Output to Case
Resistance
Capacitance
Output
Voltage accuracy
Load voltage regulation
Line voltage regulation
Over current protection
Short circuit protection
Short circuit restart
Ripple and noise
(at 20 MHz BW)
Temperature coefficient
General
Switching frequency
Safety standard compliant with
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Humidity
24 VDC, 9…36 VDC
48 VDC, 18…72 VDC
Capacitors
on: pin open or 2.5...5.5 V
off: pin to gnd or 0.7...0.8 V
1,5 kVDC for 1 min., test 1 s
1000 VDC for 1 min.
9
10 Ω
1200 pF, typ.
300 kHz, typ.
IEC60950-1 : 2001
-40 °C to +85 °C
100 °C, max.
-40 °C to +125 °C
Up to 95 %,
non-condensing
Free-air convection
Cooling
Physical
Dimensions
Weight
Case material
Potting material
Pin material
Absolute maximum ratings
Soldering temperature
1.5mm distance from case
Input voltage for max. 100 ms
24 V input types
48 V input types
±1%
± 0.5 %, at 10..100 % load
± 0.5 %, max.
140 % of max. Iout
Continuous
Automatic
75 mVp-p, max.
± 0.02% / °C
50.80 x 25.40 x 10.16 mm
30.0 g
Nickel-coated copper
Epoxy (UL94V-0 rated)
Brass solder coated
260 °C for 10 s
-0.7...40 V
-0.7...80 V
Input reflected ripple current measure circuit
The input reflected
ripple current is
measured through a
source inductor
12 µH and a source
capacitor Cin 47 µF,
ESR<1 ohm at 100 kHz
at nominal input voltage
and full load.
+ Input
Measure
Point
L: 12 µH
1
3
+Vin
47µF
33µF
ESR
<1Ω
@ 100kHz
+Vout
Current
Probe
DC/DC – Converter
Resistive
load
2
5
-Vin
-Vout
- Input
Output ripple & noise reduction
To reduce ripple and noise,
it is recommended to use
a 1µF ceramic disk and a
10 µF electrolytic capacitor.
+ Input
1
4
+Vin
+Vout
10µF
1µF
10µF
Load
DC/DC – Converter
2
5
-Vin
-Vout
- Input
On / Off Control
Positive logic turns ON the
module during high logic
and Off during low logic.
CTRL function can be
controlled by an external
switch between the CRTL
terminal and –Vin terminal.
The switch can be an open
collector or open drain for
positive logic. If the CTRL
feature is not used then do
not connect the CTRL pin.
+ Input
1
+Vin
+Vout
ON
Remote
Control
OFF
OFF
CTRL
DC/DC – Converter
3
ON
- Input
-Vin
-Vout
2
Page 2of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
15W DC-DC Converter P15E-Series
Dimensions
COM /
no Pin
COM /
no Pin
Pin
1
2
3
4
5
6
Standard version
Single output
+ V input
- V input
+ V output
No pin
- V output
No pin
Dual output
+ V input
- V input
+ V output
Common
- V output
No pin
Version with remote control input option
Single output
Dual output
+ V input
+ V input
- V input
- V input
+ V output
+ V output
No pin
Common
- V output
- V output
Remote control
Remote control
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected
to result in significant injury to the user.
Rev: 11 / 11f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]