Download

40W DC-DC Converter P40B-Series
●
●
●
●
●
●
●
●
●
●
●
●
Wide 4:1 input range
Efficiency up to 92%
Adjustable output voltage
Remote control on/off
1600 VDC isolation
Continuous short circuit protection
Over voltage protection
Over Temperature protection
Standard package 2” x 2” x 0.4”
MTBF >150 khrs
-40...+85°C operating temperature range
Soft start function
Model selection guide
Type
Input
nominal
voltage
[VDC]
Single output
P40B243R3S
P40B2405S
P40B2412S
P40B2415S
P40B483R3S
P40B4805S
P40B4812S
P40B4815S
Dual output
P40B2412D
P40B2415D
P40B4812D
P40B4815D
Input current
no load full load
[mA]
[mA]
Output
voltage
Output
current
Ripple &
noise
*3
Z-Diode
output
protection
Efficiency
typ.
@ full load
Capacitive
load
*4
[VDC]
[mA]
[mVpk-pk]
[VDC]
[%]
[µF]
9...36
9...36
9...36
9...36
18...75
18...75
18...75
18...75
80
100
50
50
60
60
30
30
1600
1900
1920
1920
800
950
960
950
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
10000
8000
3350
2650
10000
8000
3350
2650
50
50
75
75
50
50
75
75
3.9
6.2
15
18
3.9
6.2
15
18
89
91
90
90
89
92
90
91
25000
13000
2300
1500
25000
13000
2300
1500
9...36
9...36
18...75
18...75
60
60
30
30
1940
1940
960
960
±12.0
±15.0
±12.0
±15.0
±1650
±1350
±1650
±1350
150
150
150
150
±15
±18
±15
±18
89
89
90
90
2 x 1200
2 x 750
2 x 1200
2 x 750
Application example for single output version
+ INPUT
C1
+ 220µF
< 90 mΩ
L 12µH
C2
1µF
100V
The output voltage can be externally
trimmed by using the method shown below.
( ) for dual output trim
1
6
Remote
ON
5 +SENSE
3
DC/DC - Converter
P40Bxxxxx
Remote
OFF
+ OUTPUT
R - Trim down
8
C-load
See table
4 -SENSE
R - Trim up
- OUTPUT
- INPUT
7
2
1. For the Single output: Maximum output deviation is 10 % inclusive of remote sense and trim. If remote sense is not being used,
the + SENSE should be connected to it’s corresponding +OUTPUT and likewise the - SENSE should be connected to its
corresponding -OUTPUT.
2. One load is 25 % to 100 % load, the other load is 100 % load, the output voltage variable rate is within ± 5 %.
3. Measured with 20 MHz bandwidth and 1.0 µF ceramic capacitor.
4. Tested by minimal Vin and constant resistive load.
5. Tested by normal Vin and 25 % load step change ( 75 %-50 %-25 % of full load ).
6. Measured Input reflected ripple current with a simulated source inductance of 12 µH.
7. The remote on / off control pin is referenced to –Vin (pin 2).
8. The P40B-series can meet EN55022 Class A with an external filter in parallel with the input pins .
9. An external filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5.
The filter capacitor PHI-CON suggest: NIPPON CHEMI-CONs KY - series, 220 µF / 100V.
10. Exceeding the absolute ratings of the unit could cause damage. It is not allowed for continuous operating!
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
40W DC-DC Converter P40B-Series
Specifications
Input
Under Voltage lockout
Vin 24V types
Vin 48V types
Filter
Reflected ripple current *6
Remote control levels *7
On
Off
Off input idle current
Isolation:
Rated voltage (tested for 3 s)
Resistance
Capacitance
Output
Voltage accuracy
Output voltage trim range
Voltage cross balance
(dual outputs) *2
Line voltage regulation
Load voltage regulation single
Load voltage regulation dual
Temperature coefficient
Transient recovery time *5
Transient response deviation
*5
Short circuit protection
Over load protection
Short circuit restart
on @ 8.6 VDC, off @ 7.9 VDC
on @ 17.8 VDC, off @ 16 VDC
π - type
20 mAp-p, typ.
3~12 VDC or open input
0~1.2 VDC
5 mA, typ.
1600 VDC
9
10 Ω
2500 pF, typ.
±1%
± 10 %
±5 % @ 25 % / 100 % of load
± 0.5 %
± 0.5 % @ 0 %...100 % load
± 1 % @ 1 %...100 % load
± 0.02 % / °C
250 µs, typ
3%
Continuous, hiccup
130 % of full load, typ.
Automatic
General
Start up time
Switching frequency
Safety standard in accordance with
Reliability Calculated MBTF
EMC characteristics
Radiated emissions
Conducted emissions *8
ESD
RS
EFT *9
Surge *9
CS
PFMF
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Over temp. protection
Humidity
Cooling
Physical
Dimensions
Weight
Case material
Potting Material
Absolute max. ratings *10
Pin soldering temperature
1.5 mm distance from body
Max. input voltage for 0.1s
Vin 24 V types
Vin 48 V types
25 ms @ R-load
270 kHz, typ.
IEC / EN 60950-1
>150000 hrs
EN55022 Class A
EN55022 Class A
EN61000-4-2 pref criteria A
EN61000-4-3 pref criteria A
EN61000-4-4 pref criteria A
EN61000-4-5 pref criteria A
EN61000-4-6 pref criteria A
EN61000-4-8 pref criteria A
-40 °C to +85 °C with derating
-40 °C to +55 °C full load
105 °C, max.
-40 °C to +125 °C
t-case 110 °C, typ
Up to 95 %,
non-condensing
Free-air convection
50.80 x 50.80 x 10.16 mm
60 g
Nickel-coated brass
Epoxy (UL94V-0 rated)
260°C for 10 sec
-0.7~50 VDC
-0.7~100 VDC
Efficiency vias load change
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
40W DC-DC Converter P40B-Series
Dimensions
Pin configuration
Pin
1
2
3
4
5
6
7
8
Single
+ Vin
- Vin
Rem ctrl
- Sense
+ Sense
+ Vout
- Vout
Trim
Dual
+ Vin
- Vin
Rem ctrl
+ Vout
Common
Common
- Vout
Trim
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the
instructions for use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems
without the express written approval of an officer of the Company. Life support systems are devices which support or
sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the
labeling, can be reasonably expected to result in significant injury to the user. Rev: 9.12 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]