Download

60W DC-DC Converter P60A-Series
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Wide 2:1 input range
Efficiency up to 92%
Adjustable output voltage
Remote control on/off
1600 VDC isolation
Continuous short circuit protection
Over voltage protection
Over current protection
Over Temperature protection
Under voltage lockout
Soft start function
Standard package 2” x 2” x 0.4”
Output with sense feedback
-40...+85°C operating temperature range with derating
Model selection guide
Type
Input
nominal
voltage
[VDC]
Single output
P60A243R3S
P60A2405S
P60A2412S
P60A2415S
P60A483R3S
P60A4805S
P60A4812S
P60A4815S
18...36
18...36
18...36
18...36
36...75
36...75
36...75
36...75
Input current
no load full load
[mA]
80
100
40
40
50
60
40
40
[mA]
2150
2760
2800
2800
1075
1390
1400
1400
Output
voltage
Output
current
Ripple &
noise
*3
Z-Diode
output
protection
Efficiency
typ.
@ full load
Capacitive
load
*4
[VDC]
[A]
[mVpk-pk]
[VDC]
[%]
[µF]
0...14
0...12
0...5
0...4
0...14
0...12
0...5
0...4
75
75
100
100
75
75
100
100
3.9
6.2
15
18
3.9
6.2
15
18
91
92
91
91
91
92
91
91
33000
20000
3300
2200
33000
20000
3300
2200
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
Application example for single output version
+ INPUT
C1
+ 220µF
< 90 mΩ
L 12µH
C2
1µF
100V
The output voltage can be externally
trimmed by using the method shown below.
( ) for dual output trim
1
6
Remote
ON
5 +SENSE
3
DC/DC - Converter
P60Axxxxx
Remote
OFF
+ OUTPUT
R - Trim down
8
C-load
See table
4 -SENSE
R - Trim up
- OUTPUT
- INPUT
7
2
1. For the Single output: Maximum output deviation is 10 % inclusive of remote sense and trim. If remote sense is not being used,
the + SENSE should be connected to it’s corresponding +OUTPUT and likewise the - SENSE should be connected to its
corresponding -OUTPUT.
2. One load is 25 % to 100 % load, the other load is 100 % load, the output voltage variable rate is within ± 5 %.
3. Measured with 20 MHz bandwidth and 1.0 µF ceramic capacitor.
4. Tested by minimal Vin and constant resistive load.
5. Tested by normal Vin and 25 % load step change ( 75 %-50 %-25 % of full load ).
6. Measured Input reflected ripple current with a simulated source inductance of 12 µH.
7. The remote on / off control pin is referenced to –Vin (pin 2).
8. The P60B-series can meet EN55022 Class A with an external filter in parallel with the input pins .
9. An external filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5.
The filter capacitor PHI-CON suggest: NIPPON CHEMI-CONs KY - series, 220 µF / 100V.
10. Exceeding the absolute ratings of the unit could cause damage. It is not allowed for continuous operating!
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
60W DC-DC Converter P60A-Series
Specifications
Input
Under Voltage lockout
Vin 24V types
Vin 48V types
Filter
Reflected ripple current *6
Remote control levels *7
On
Off
Off input idle current
Isolation:
Rated voltage (tested for 3 s)
Resistance
Capacitance
Output
Voltage accuracy
Output voltage trim range
Voltage cross balance
(dual outputs) *2
Line voltage regulation
Load voltage regulation single
Load voltage regulation dual
Temperature coefficient
Transient recovery time *5
Transient response deviation
*5
Short circuit protection
Over load protection
Short circuit restart
on @ 17.8 VDC, off @ 16 VDC
on @ 33.5 VDC, off @ 30.5VDC
π - type
20 mAp-p, typ.
3~12 VDC or open input
0~1.2 VDC
5 mA, typ.
1600 VDC
9
10 Ω
2500 pF, typ.
±1%
± 10 %
±5 % @ 25 % / 100 % of load
± 0.5 %
± 0.5 % @ 0 %...100 % load
± 1 % @ 1 %...100 % load
± 0.02 % / °C
250 µs, typ
3%
Continuous, hiccup
130 % of full load, typ.
Automatic
General
Start up time
Switching frequency
Safety standard in accordance with
Reliability Calculated MBTF
EMC characteristics
Radiated emissions
Conducted emissions *8
ESD
RS
EFT *9
Surge *9
CS
PFMF
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Over temp. protection
Humidity
Cooling
Physical
Dimensions
Weight
Case material
Potting Material
Absolute max. ratings *10
Pin soldering temperature
1.5 mm distance from body
Max. input voltage for 0.1s
Vin 24 V types
Vin 48 V types
20 ms @ R-load
270 kHz, typ.
IEC / EN 60950-1
>110000 hrs
EN55022 Class A
EN55022 Class A
EN61000-4-2 pref criteria A
EN61000-4-3 pref criteria A
EN61000-4-4 pref criteria A
EN61000-4-5 pref criteria A
EN61000-4-6 pref criteria A
EN61000-4-8 pref criteria A
-40 °C to +85 °C with derating
-40 °C to +40 °C full load
110 °C, max.
-40 °C to +125 °C
t-case 120 °C, typ
Up to 95 %,
non-condensing
Free-air convection
50.80 x 50.80 x 10.16 mm
70 g
Nickel-coated brass
Epoxy (UL94V-0 rated)
260°C for 10 sec
-0.7~50 VDC
-0.7~100 VDC
Efficiency vias load change
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
60W DC-DC Converter P60A-Series
Dimensions
Pin configuration
Pin
1
2
3
4
5
6
7
8
Single
+ Vin
- Vin
Rem ctrl
- Sense
+ Sense
+ Vout
- Vout
Trim
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems
without the express written approval of an officer of the Company. Life support systems are devices which support or
sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the
labeling, can be reasonably expected to result in significant injury to the user.
Rev: 9 / 12f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00