MYLSM00502ERPL DATA Sheet 1 DC-DC Converter DATA Sheet MYLSM00502ERPL 1. Features ・Wide input voltage range. (8.0V~13.2V) ・Single Output Voltage(Iout=2.5A) and Surface Mount Type of Non-insulated DC-DC Converter. ・Ultra small size and low profile. ・High Efficiency product. ・Wide adjustable output voltage by connecting external resistors. (1.0 to 5.25V) ・On/Off function and short circuit protection is built in. 2. Appearance, Dimensions 【Unit:mm】 Tolerance ±0.3mm Toleranc is not accumulated. Note: 1.This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2.This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 2 Marking Engraved on the metal case (1) Pin No.1 Side Marking (2) Manufacturer Parts No. (3) Manufacturer ID (4) Lot No. ○ MYLSM00502EEPL MURATA ■■■■■■ ①②③④④④ ①Production factory Mark ② Production Year ③ Production Month(1,2,3,・・・・・・,9,O,N,D) ④ Production Lot.No. (3 End Digit Of Production Lot) Pin Number and Function Pin No. Symbol Function 1 VAR Output voltage adjustment 2,3,6,8 GND GND 4 Vin Input 5 ON/OFF Remote ON/OFF 7 Vout Output 9 G-PAD GND-Pad 3. Block Diagram Vout Vin 7 4 2,3 6,8 GND 5 GND Control Circuit ON/OFF 1 VAR Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 3 4. Environmental Conditions o 5. Absolute Maximum Rating Item Maximum Input Voltage ON/OFF VAR Terminal Voltage o -10 C ~ +85 C o o -20 C ~ +85 C 10% ~ 85%(No water condenses in any cases.) 5% ~ 90%(No water condenses in any cases.) 4 .1. Operating Temperature Range 4 .2. Storage Temperature Range 4 .3. Operating Humidity Range 4 .4. Storage Humidity Range Unit V V V Absolute Rating +17 Vin +7 ※No voltage, no matter how instantaneous, shall be applied beyond the absolute maximum voltage rating to this product. If you apply any voltage over this limit the product characteristics will deteriorate or the product itself will be destroyed. Even though it may continue operating for a while after the over-voltage event, its life will likely be shortened significantly. Reliability and life of the module may degrade similarly if the maximum operating voltage rating is continuously exceeded. This product is designed to operate within the maximum operating voltage rating specification. 6. Characteristics o 6.1. Electrical Characteristics (Ta=25 C) Value Item Input Voltage Output Voltage Condition Symbol Min. Typ. Max. +8.0 +12.0 +16.0 RVAR=381kΩ +0.96 +1.00 +1.04 RVAR=short +5.04 +5.25 +5.46 Output voltage adjustable range +1.0 - +5.25 Vin Vout Vin=8.0~16.0V Io=0~2.5A Vin>Vo+3V ※1 Unit V Output Current Iout Vin=8.0~16.0V 0 - 2.5 A Output Peak Current Iop Vin=8.0~16.0V - - 2.5 A Ripple Voltage Vrip - 30 - mV(p-p) Efficiency EFF - 85 - % - - 0.3 ON/OFF Voltage ON/OFF Undervoltage Lockout threshold UVLO Short Circuit Protection SCP Vin =12.0V, Vout=3.3V,Iout=2.5A,BW=20MHz Vin =12.0V Vout=3.3V,Iout=2.5A Vin=8.0~16.0V Io=0~2.5A REN=100kΩ Vin=8.0~16.0V Io=0~2.5A OFF V Open ON 1.0 - Vin Failing input voltage 2.5 2.7 2.9 Hysteresis - 0.2 - If output is shorted to GND , DC-DC Converter shall be operated in a drooping characteristic. After the short circuit event has cleared, the output is automatically brought back into regulation. ※2 <Caution> ※1 Input voltage shall be sat Vin>Vo+3V. And please turn on and off at this condition. ※2 Please avoid continuous SCP condition. Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 4 6. 2. Output Current Derating Output Current Derating Io [ A ] Ta [ ℃ ] 7. Operation in information 7.1. Output Voltage Adjustment The output voltage can be adjusted by connecting resistors between VAR-pin(1pin) to GND-pin. The following chart gives the required external-resistor value to adjust the output voltage . <RVAR calculation example> Vout[V] RVAR 1.0V 382kΩ 1.5V 96.1kΩ 3.3V 14kΩ 5.0V 1.047kΩ 5.25V 0 RVAR = 80 / ( Vo – 0.8 ) -18 [kΩ] Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 5 7.2. ON/OFF control ON/OFF function The DC-DC Converter can be inactive by using ON/OFF function. ON/OFF EN EN ON/OFF 10k EN(Hi-z) When the EN terminal is open, the activity is indetermination. So if you connect EN terminal with open corrector and open drain circuits, please use pull up or pull down resister to fixed voltage of EN terminal high or low.(you shall choice the value of resistor under 100kΩ) 8. Reliability 8.1. Humidity According to JIS-C-0022. 40 土2°C, 90 to 95%RH, 100 hours. Leave for 4 hours at room temperature. No damage in appearance and no deviation from electrical characteristics (section 6.1.). 8.2. Temperature Cycles Repeat cycle 5 times. Leave 2 hours at room temp. No damage in appearance and no deviation from electrical characteristics (section 6.1.). Step Condition Time 1 -20°C±3°C 30 minutes 2 Room Temp. 10-15 minutes 3 +85°C±2°C 30 minutes 4 Room Temp. 10-15 minutes Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 6 9. Test Circuit In the following test circuit, the initial values under item 6.1. should be met. 9.1. General Measure Circuit MYLSM00502ERPL A VOUT VIN EN RVAR VAR C2 C1 Vin C3 Vr V RL REN GND GND G-PAD V A Vr Digital Multi meter HP34401A equivalent (Keysight Technologies) Ripple Voltmeter RM-101 equivalent ( Keisokugiken Electronic Load Device EUL-150αXL equivalent DC Power Supply HP6654A equivalent ( Fujitsu access ) RL C1 C2 C3 RVAR REN (Keysight Technologies) :Ceramic Capacitor 10μF/25V (GRM32DR71E106KA12 : Murata) :Ceramic Capacitor 47μF/6.3V (GRM31CC80J476KE18 : Murata) :Ceramic Capacitor 0.1μF/50V (GRM188R11H104KA93 : Murata) :Chip Resistor ±0.5% , 1/16W :Chip Resistor ±5% , 100kΩor less,1/16W 9.2. Ripple Voltage Measurement Circuit L L≦3cm Ripple Voltmeter or Oscilloscope Keisokugiken RM-101 equivalent or Tektronix 460A equivalent DC-DC Converter load Terminating resistance Keisokugiken TRC-50F equivalent Output capacitor Coaxial cable(1.5D-2V,L=1.5m) A :Output Ripple Noise B :Output Ripple Voltage B A C :Switching cycle C Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 7 10. Packaging Specification 10.1. Embossed Tape Dimension 7.50±0.1 B A (5°) 4.00±0.1 A’ 0.30±0.05 B’ φ1.50 +0.1 -0 8.40±0.1 16.00±0.1 16.00 +0.3 -0.1 φ1.50 +0.1 -0 1.75±0.1 2.00±0.1 2.50±0.1 Section B-B’ 8.40±0.1 (5°) Section A-A’ 10.2. Reel Dimensions 21.5±1.0 17.5±1.0 φ100±1 φ330±2 A 2.0±0.5 表示 Indication φ21.0±0.8 φ13.0±0.5 A部詳細図 Portion A Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 8 10.3. Taping Specification 未実装部 Empty portion (200mm MIN) 未実装部 Empty portion (180mm MIN) リーダー部 Leader portion (200mm MIN) 部品収納部 "Module on tape" portion 表示 Indication 丸穴 AF AF M M 引き出し方向 Pull direction The modules is located such as case in upper side and terminal in lower side. 10.4. Note 1. The adhesive strength of the protective tape must be within 0.2-0.95N. 2. Each reel contains 1,000pcs. 3. Maximum 2 pockets of no unit are allowed except the empty portion of both start and end. The one unit in pocket shall not be consecutive. 4. The reel is labeled with Murata part number, quantity and Inspection No.. 5. The color of reel is not specified. Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 9 11. Mounting Condition 11.1. PCB Land Pattern Recommendation 1.35 1.0 2.6 1.0 1.2 0.6 1.2 0.6 1.2 1.35 0.3 1.2 2.6 0.3 1.35 3.35 1.0 7.9 1.0 3.35 1.35 0.3 0.3 1.55 1pin 1.55 7.9 Soldering land :製品ランド Area prohibits wirings other than land. There are wiring coppers or through-hole via at the bottom side of the DC-DC converter. When you design your PCBs, please be careful not to short the circuit of the DC-DC converter or PCBs. Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 10 11.2. Recommendable Condition of Soldering 11.2.1. Re-flow Soldering Please solder under the following condition. Method Soldering temperatture o Soldering time (Over 250 C) o (Over 220 C) Preheating Times : : : : : : Infrared ray re-flow soldering. o Case surface temperature 260 C Max. 20 seconds max (Case surface temperature) 30~75 seconds (Case surface temperature) o 60~150 seconds(150~200 C) 1time 260℃Max. 250℃ Case surface temperature 20 seconds max. 220℃ 200℃ Colling curve 2~3℃/seconds 30~75 seconds 150℃ 60~150 seconds Soldering time ※Do not vibrate for the products on reflow. Please need to take care temperature control because mounted parts may come off if the product are left under the high temperature. Do not reflow DC-DC converter as follows, because DC-DC converter may fall down from a substrate during reflowing Substrate DC-DC Converter 11.2.2. Recondition the soldering after re-flow Perform within 4 seconds while the temperature of soldering iron is 380℃max., andit’s power is 30W or less. Don’t put the edge of soldering iron and solder on the pin of product, but put on the end of solder land. Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 11 12. Characteristics Data 1.03 1.53 1.02 1.52 1.01 1.51 OUtputVoltage [V] OUtputVoltage [V] 12.1.Static Electrical Characyeristics Vin=12.0V (Ta=25℃) 1.00 0.99 0.98 0.97 1.50 1.49 1.48 1.47 0.0 0.5 1.0 1.5 2.0 2.5 3.0 0.0 0.5 1.0 Iout [A] Fig.12-1-1. Output Voltage vs. Output Current(Vout=1.0V) 2.0 2.5 3.0 Fig.12-1-2. Output Voltage vs. Output Current(Vout=1.5V) 2.53 3.33 2.52 3.32 2.51 3.31 OUtputVoltage [V] OUtputVoltage [V] 1.5 Iout [A] 2.50 2.49 2.48 2.47 3.30 3.29 3.28 3.27 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Iout [A] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Iout [A] Fig.12-1-3. Output Voltage vs. Output Current(Vout=2.5V) Fig.12-1-4. Output Voltage vs. Output Current(Vout=3.3V) 5.28 OUtputVoltage [V] 5.27 5.26 5.25 5.24 5.23 5.22 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Iout [A] Fig.12-1-5. Output Voltage vs. Output Current(Vout=5.25V) Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 100 100 95 95 90 90 Efficiency [%] Efficiency [%] 12 85 80 75 70 65 85 80 75 70 65 60 60 0.0 0.5 1.0 1.5 2.0 2.5 3.0 0.0 0.5 1.0 Iout [A] Fig.12-1-6. Efficiency vs. Output Current (Vout=1.0V) 2.0 2.5 3.0 Fig.12-1-7. Efficiency vs. Output Current (Vout=1.5V) 100 100 95 95 90 90 Efficiency [%] Efficiency [%] 1.5 Iout [A] 85 80 75 70 65 85 80 75 70 65 60 60 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Iout [A] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Iout [A] Fig.12-1-8. Efficiency vs. Output Current (Vout=2.5V) Fig.12-1-9. Efficiency vs. Output Current (Vout=3.3V) 100 95 Efficiency [%] 90 85 80 75 70 65 60 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Iout [A] Fig.12-1-10. Efficiency vs. Output Current (Vout=5.25V) Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 13 12.2.Dynamic Electrical Characyeristics Vin=12V, Vout=1.0V (Ta=25℃) Vin(10V/div) Vout(500mV/div) Fig.12-2-1. Start-up Waveform (Io=0A) Vin(10V/div) Vout(500mV/div) Fig.12-2-3. Stop-down Waveform (Io=0A) Vout(50mV/div) Vin(10V/div) Vout(500mV/div) Fig.12-2-2. Start-up Waveform (Io=2.75A) Vin(10V/div) Vout(500mV/div) Fig.12-2-4. Stop-down Waveform (Io=2.75A) Vout(50mV/div) Iout(2A/div) Iout(2A/div) Fig.12-2-5. Load Transient Response (Io= 0 → 2.75A/2.5μs) Fig.12-2-6. Load Transient Response (Io= 2.75 → 0A/2.5μs) Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 14 Vin=12V, Vout=2.5V (Ta=25℃) Vin(10V/div) Vout(1V/div) Fig.12-2-7. Start-up Waveform (Io=0A) Vin(10V/div) Vout(1V/div) Fig.12-2-9. Stop-down Waveform (Io=0A) Vout(50mV/div) Vin(10V/div) Vout(1V/div) Fig.12-2-8. Start-up Waveform (Io=2.75A) Vin(10V/div) Vout(1V/div) Fig.12-2-10. Stop-down Waveform (Io=2.75A) Vout(50mV/div) Iout(2A/div) Iout(2A/div) Fig.12-2-11. Load Transient Response (Io= 0 → 2.75A/2.5μs) Fig.12-2-12. Load Transient Response (Io= 2.75A → 0/2.5μs) Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 15 Vin=12V, Vout=5.25V (Ta=25℃) Vin(10V/div) Vout(2V/div) Fig.12-2-13. Start-up Waveform (Io=0A) Vin(10V/div) Vout(2V/div) Fig.12-2-15. Stop-down Waveform (Io=0A) Vout(50mV/div) Vin(10V/div) Vout(2V/div) Fig.12-2-14. Start-up Waveform (Io=2.75A) Vin(10V/div) Vout(2V/div) Fig.12-2-16. Stop-down Waveform (Io=2.75A) Vout(50mV/div) Iout(2A/div) Iout(2A/div) Fig.12-2-17. Load Transient Response (Io= 0 → 2.75A/2.5μs) Fig.12-2-18. Load Transient Response (Io=2.75A → 0/2.5μs) Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 16 13. Notice 13.1. Please do not use a connector or a socket for connection with your board of this product. Electrical performance may be deteriorated the influence of contact resistance. Please be sure to mount this product with solder. 13.2. Be sure to provide an appropriate fail-safe function on your product to prevent a second damage that may be caused by the abnormal function or the failure of our product. 13.3. Input / Output capacitor When a inductance or a switch devise are connected to the input line, or when you use a power supply with output inductance as the input voltage source, the input voltage of the DC-DC converter will be fluctuated. By this input voltage fluctuation, the transient load response of the DC-DC converter may be deteriorated or abnormal oscillation may occur. So please confirm normal operation on each application. Please use external input capacitor in order to decrease inductance of input line. 13. 4. Wiring of input / output capacitor In the case of input / output capacitor connection, in order to reduce electrical noise, please design PCBs with consideration of the following item. ①.Please be sure to check normal operation on your system. ②.Please use low impedance capacitors with good high frequency characteristic. ③.Please shorten those leads of each capacitor as much as possible, and make sure the lead Inductance low. ④.Both input-side and output side, please make the wiring loop between plus and minus as small as possible.The influence of leakage inductance can be reduced. ⑤.Please design the print pattern of the main circuit as wide and short as possible. Make wiring roop small Make wiring roop small +Vin +Vin +Vout +Vout DC-DC Converter +Vin Load -Vin GND C1 C2 shorten the leads and pattern shorten the leads and pattern 13.5. This product should not be operated in parallel or in series. 13.6. Inrush current protection is not a feature of this product. Please be careful that surge voltage caused by wiring indcutance etc. may make the product damage when input voltage is applied suddenly to the product. 13.7. Please connect the input terminal with proper polarity. If you connect wrong polarity, the DC-DC Converter may be broken. In the case of the DC-DC Converter is damaged, abnormal input current may flow in, and abnormal overheat of the DC-DC Converter, or some damage of your products may occur. Please use a diode and a fuse to as following figure. fuse + + + diode IN - OUT Load - ※Please select diode and fuse after confirming the operation. Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 17 13.8. Cleaning Please use no-cleaning type flux and do not wash this product. 13.9. Storage 13.9.1. Please store the products in room where the temperature/humidity is stable and direct sunlight cannot come in, and use the products within 6 months after delivery. Please avoid damp and heat or such places where the temperature greatly changes, as water may condenseon this product, and the quality of characteristics may be reduced, and/or be the solderability may be degraded. If this product needs to be stored for a long time (more than 1 year), this product may be degraded in solderability and/or corroded. Please test the solderability of this product regularly. Baking before reflow process is unnecessary to store the products under 30℃,60%RH or less up to 6 months. In case the storage condition is over above mentioned, if these are unpacked condition, please bake them at 125℃±5℃/24hour. If these are packed in a tape, please bake them before soldering at 60℃±5℃/168hour. 13.9.2. Please do not store this product in places such as : A dusty place, a place exposed directly to sea breeze, or in an atmosphere containing corrosive gas (Cl2,NH3,SO2,NOX and so on). 13.10. Operational Environment and Operational Conditions 13.10.1. Operational Environment The products are not waterproof, chemical-proof or rust-proof. In order to prevent leakage of electricity and abnormal temperature increase of the products, do not use the products under the following circumstances: (1) in an atmosphere containing corrosive gas (Cl2, NH3, SO2, NOX and so on). (2) in a dusty place. (3) in a place exposed to direct sunlight. (4) in such a place where water splashes or in such a humid place where water condenses. (5) in a place exposed to sea breeze. (6) in any other places similar to the above (1)through (5). 13.10.2. Operational Conditions Please use the products within specified values (power supply, temperature, input, output and load condition, and so on). Input voltage drop for line impedance, so please make sure that input voltage is included in specified values. If you use the products over the specified values, it may break the products, reduce the quality, and even if the products can endure the condition for short time, it may cause degradation of the reliability. Also please take care that the external voltage over output voltage of DC-DC Converter does not applies to output of this DC-DC Converter. 13.10.3. Note prior to use If you apply high static electricity, over rated voltage or reverse voltage to the products, it may cause defects in the products or degrade the reliability. Please avoid the following items: (1) over rating power supply, reverse power supply or not-enough connection of 0 V(DC) line. (2) electrostatic discharge by production line and/or operator. (3) electrified product by electrostatic induction. Do not give an excessive mechanical shock. If you drop the products on the floor, etc., it may occur a crack to the core of inductors and monolithic ceramic capacitors. Do not give a strong shock such as a drop in handling. 13.11. Transportation If you transport the products, please pack them so that the package will not be damaged by mechanical vibration or mechanical shock, and please educate and guide a carrier to prevent rough handling. If you transport the products to overseas (in particular, by sea), it is expected that the transportation environment will be the worst, so please pack the products, in the package designed on the consideration of mechanical strength, vibration-resistant and humidity-resistant. The package of the products which Murata sells in Japan, may not resist over seas transport. Please consult us if you are to use the Murata package of the products sold in Japan for transport to overseas. Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21 MYLSM00502ERPL DATA Sheet 18 Note 1. Murata recommends that customers ensure that the evaluation and testing of these devices are completed with this product actually assembled on their product. 2. Please contact our main sales office or nearby sales office before using our products for the applications listed below which require especially high reliability for the prevention of defects which might directly cause damage to the third party’s life, body or property or this products for any other applications that described in the above. ①Aircraft equipment ②Aerospace equipment ③Undersea equipment ④Power plant control equipment ⑤Medical equipment ⑥Transportation equipment (vehicles, trains, ships, etc.) ⑦Traffic signal equipment ⑧Disaster prevention /crime prevention equipment ⑨Data-processing equipment ⑩Application of similar complexity and/or reliability requirements to the applications listed in the above. 3. If you have any concerned materials other than RoHS directive, please contact us. 4. About the written contents, since changing without a preliminary announcement for improvement and supply are sometimes stopped, please confirm in case of ordering. If written contents are unknown, please ask to our main sales office or nearby sales office. Note: 1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. 2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 2016.1.21