DCT Duct Cutting Tool

A.
System
Overview
PHYSICAL INFRASTRUCTURE SYSTEMS
B.
Copper
Systems
Panduct ® Installation Tools
• DCT easily cuts any Panduct® Duct and Cover
C.
Fiber
Optic
Systems
• DNT-100 notches sidewalls to bottom scoreline for tees
and corner junctions
Part Number
Std.
Pkg.
Qty.
Part Description
Duct Cutting Tool
DCT
DCT
Hand-held duct cutting tool.
1
Duct Notching Tool (For use with all slotted duct types)
DNT-100
D.
Power
over
Ethernet
Hand-held sidewall notching tool.
1
E.
Zone
Cabling
Always use approved safety goggles when using any tools.
F.
Wireless
G.
Outlets
DNT-100
H.
Media
Distribution
Panduct ® Type HN, H, and HS Wiring Duct – Wirefill Capacity
Electrical
8
10
AWG AWG
12
AWG
Nominal
0.216 0.164 0.130 0.141
Duct
Size
Nominal
(W x H)
Area
In.
In.²
THHN THHN THHN MTW
1.50 x 2.00 3.000
34
60
95
81
1.50 x 3.00 4.500
52
90
143 122
2.00 x 2.00 4.000
46
80
127 108
2.00 x 3.00 6.000
69
120
191 163
2.00 x 4.00 8.000
92
160
255 217
3.00 x 3.00 9.000
104
180
287 244
3.00 x 4.00 12.000
139
241
383 326
4.00 x 4.00 16.000
185
321
511 435
Communication
14
AWG
16
AWG
18
AWG
22
AWG
23 AWG
23/24 24 Fiber
AWG AWG Cable
0.152 0.111 0.124 0.133 0.096 0.111 0.118 0.084 0.100 0.106 0.085 0.300 0.240 0.240 0.225 0.118
MTW THHN MTW
70
131 105
105 197 158
93
175 140
140 263 210
187 350 281
210 394 316
280 526 421
374 701 562
MTW
91
137
122
183
244
275
366
488
TFFN
175
263
234
351
469
527
703
938
MTW
131
197
175
263
350
394
526
701
MTW
116
174
155
232
310
349
465
621
TFFN
229
344
306
459
612
689
919
1225
Cat.
Cat. 6A Cat.
MTW MTW MTW 6A (SD)
6
162 144 224
18
28
28
243 216 336
27
42
42
216 192 299
24
37
37
324 288 448
36
56
56
432 384 598
48
75
75
486 432 673
54
84
84
648 577 897
72 112 112
864 769 1197 96 150 150
Cat.
5e
32
48
42
64
85
96
128
170
3.0
mm
116
174
154
232
309
348
464
619
Table shows maximum wire fill based on 50% of duct internal cross sectional area. Formula = Nominal Area/1.85 x D². All dimensions represent typical outer
cable diameter in inches.
Electrical
Nominal
0.216 0.164
Duct
Size
Nominal
(W x H)
Area
THHN THHN
In.
In.²
2.00 x 2.00
4.000
48
84
2.00 x 3.00
6.000
73
127
2.00 x 4.00
8.000
97
169
12
AWG
14
AWG
MTW MTW THHN MTW
114 98
185 148
172 148 278 222
229 197 371 297
MTW
129
193
258
TFFN
248
372
496
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
Communication
16
AWG
18
AWG
22
AWG
23 AWG
23/24 24 Fiber
AWG AWG Cable
0.130 0.141 0.152 0.111 0.124 0.133 0.096 0.111 0.118 0.084 0.100 0.106 0.085 0.300 0.240 0.240 0.225 0.118
THHN
135
202
270
J.
Overhead &
Underfloor
Routing
M.
Grounding &
Bonding
Panduct ® Shielded Wiring Duct – Wirefill Capacity
8
10
AWG AWG
I.
Physical
Infrastructure
Management
MTW
185
278
371
MTW
164
246
328
TFFN
323
485
647
MTW
228
342
457
Cat.
Cat. 6A Cat.
MTW MTW 6A (SD)
6
203 316
25
39
39
305 474
38
59
59
406 632
50
79
79
Cat.
5e
45
67
90
Table shows maximum wire fill based on 50% of duct internal cross sectional area. Formula = Nominal Area / 1.75 x D². All dimensions represent typical
outer cable diameter in inches. The above communication cable diameters represent the nominal Panduit cable diameter per performance level.
For specific cable fill information based on specific part numbers, please contact Panduit customer service.
3.0
mm
163
245
327
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
www.panduit.com
For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see catalog back cover).
P.13