Shielded Wiring Duct and Noise Shield - WDCB26--SA-ENG

Product Bulletin
Panduct ® PanelMax ™
Shielded Wiring Duct and Noise Shield
PanelMax ™ Shielded Wiring Duct and Noise Shield route, separate, and shield
sensitive wiring from noise emission. This allows pathways to be placed in
closer proximity, saving valuable space within industrial control panels. The
shielding provides up to 20dB reduction in noise (EMI/RFI), or 90% noise
voltage reduction (NVR), which is equivalent to 6 inches of air spacing
between sensitive and noise-emitting wiring.* **
Several wire routing and segregation configurations are possible with the
innovative Shielded Wiring Duct and Noise Shield, delivering greater
design flexibility to satisfy a wide range of applications.
These products are part of the broad range of reliable product systems
offered by the Panduit Industrial Automation Solution. These product
systems aid in reducing design and assembly time, create valuable panel
space savings, and provide easier installation and maintenance.
PanelMax™
Shielded Wiring Duct
PanelMax™
Noise Shield
PanelMax™ Shielded Wiring Duct
Key Features
Benefits
Continuous foil shield* **^‡
Durable metallic foil covers and shields outer duct surfaces providing EMI/RFI noise
reduction between sensitive and noisy wiring for up to 20dB reduction in noise, or 90%
NVR (equivalent to 6 inches of air spacing)
Slotted sidewalls with horizontal
bridge connectors
Provide wire management capability and noise reduction in the full height of the duct;
slot size compatible with various wire types and sizes, including UTP Ethernet cabling
High-quality Panduit PVC wiring
duct baseu
Fully contains and protects wiring; easy to cut and install; ensures reliable
performance and improved aesthetics; used with standard Panduit wiring duct cover;
installs with standard fasteners, including Panduit NR1 rivets
Upper and lower score lines
Facilitate duct finger and sidewall section removal to ease installation and wire routing
PanelMax ™ Noise Shield
Key Features
Benefits
Metal noise barrier* **^‡
Reduces EMI/RFI noise between sensitive and noisy wiring for up to 20dB reduction
in noise, or 90% NVR (equivalent to 6 inches of air spacing); innovative design installs
easily within Panduit wiring duct or when mounted separately, delivering greater design
flexibility to satisfy a wide range of applications
Bonding clip ^
When installing the shield inside a wiring duct, the bonding clip maintains electrical
continuity between the panel and shield for optimal noise mitigation and aesthetics
Segmented design
Speeds installation by allowing section(s) of the shield to be cut and snapped off at
intervals to easily size shield to length, with minimal deburring
Vertical wall slots
Allow wires to cross the barrier at 90° when necessary, providing greater design flexibility
Horizontal cable tie slots
Allow wire bundles to be held in place using cable ties to optimize cable management
and aesthetics
Zinc-plated steel and durable
black powder-coated surfaces
Durable powder-coated vertical surfaces for smooth edges; uncoated, corrosion
resistant, zinc-plated surface in shield contact area with sub-panel, ensures continuity
for proper bond to ground
*Recommendations for distance separation between noisy and low-noise zones are referenced in IEEE 1100 Emerald Book, Recommended Practice for Powering and Grounding
Electronic Equipment. Consult the component manufacturer for specific wire segregation distance requirements.
**PanelMax™ Shielded Wiring Duct and Noise Shield deliver approximately 20dB of noise reduction across common industrial noise frequencies at 30mm wire separation
with an approximate 1 meter coupling length.
^The shielded wiring duct or noise shield, bonding clip (if used) and enclosure must be electrically bonded to ground for the shield to be effective (see Panduit installation
instructions EP001, for shielded wiring duct or RW260, for noise shield).
‡For reference on optimal control panel layouts see the Panduit Industrial Ethernet Physical Infrastructure Reference Architecture Design Guide.
uUL Recognized continuous use temperature: 122°F (50°C)
N o i s e a n d I t s E f f e c t s o n I nProduct
d u s t r Selection
i a l C o nGuide
trols
Source
Victim
Potential noise emitters/wiring
• Variable frequency and servo
motor drives
• Switching power supplies
• Contact switching of coils
and solenoid valves
One of the core issues affecting the performance and reliability of
industrial control systems is electrical noise emitted from devices.
This electrical noise can create voltage spikes in victim wiring,
affecting component performance (as figure at left depicts).
Sensitive devices/wiring
•Communications/network
wiring (UTP Ethernet, RS232)
• High-speed counting signals
•Controllers
• Microprocessor based devices
Business Risks
• Productivity loss
•Downtime
• Maintenance/repair costs
• Device replacement costs
• Troubleshooting costs
Proper noise mitigation and panel layout practices help to ensure system productivity, quality, and safety. Panel designers
have historically used air spacing between components and wire pathways for noise mitigation, per IEEE recommendations.
With Panduit ® PanelMax™ Shielded Wiring Duct and Noise Shield, panel designers can provide noise mitigation with reduced
air spacing requirements allowing for a space optimized control panel layout.
Multi-Layered Noise Prevention and Mitigation
Panduit recommends following a multi-layered electrical noise prevention and mitigation strategy that also optimizes control
panel space utilization. This strategy includes grounding/bonding, segregation, shielding, and filtering practices to provide
optimal protection. This product bulletin focuses on noise mitigation via shielded wiring duct and noise shield products.
Refer to Panduit’s white paper WP-14, Optimizing Control Panel Layouts for Noise Mitigation in Factory Automation Systems,
for greater detail on other strategy recommendations.
Considering Shielded Cables vs. Shielded Wiring Duct and Noise Shield
An alternative to shielded wiring duct or noise shield is to consider an increased use of shielded cables, such as
shielded twisted pair network cables and shielded control cables. Shielded cables provide superior noise mitigation
and noise voltage reduction, but at a typically higher premium and installed cost than unshielded cables. Panduit ®
PanelMax™ Shielded Wiring Duct and Noise Shield add project value by providing sufficient noise mitigation at a lower
premium than a shielded cable solution.
Shielded Wiring Duct and Noise Shield advantages:
•Routing 10 standard unshielded cables in shielded wiring duct has up to a 35% lower purchased cost vs.
10 shielded cables routed in conventional wiring duct
•Shielded wiring duct and noise shield provide an effective noise mitigation solution when a shielded cable option
is not available or is difficult to source
2
Conventional Panel Layout
Motor Control and Networked Programmable Automation Controller (PAC) Panel
A conventional panel layout uses air spacing between pathways and components as a strategy to mitigate noise.
Duct color is used to indicate noisy (gray) and clean (white) pathways.
2
1
Sensitive
Noisy
3
DISTANCE
BETWEEN WIRE
PATHWAYS
(6-inch minimum)
The strategy is to keep sensitive and potentially noisy wiring/cabling separated to mitigate noise:
1
Control and potentially sensitive wiring is routed in “clean” pathways (white color).
2
Power and potentially noise-emitting wiring is routed in “noisy” pathways (gray color).
3
A 6-inch distance is used between parallel noisy and clean wire pathways to mitigate noise coupling.^
Problems to resolve:
•Difficult to lay out and maintain segregated pathways throughout design
•Distance spacing often requires a larger panel size to implement, significantly increasing panel costs
and enclosure footprint requirements
•Distance separation between wire pathways can be compromised due to panel space constraints
^As a best wiring practice, where necessary, sensitive and potentially noisy wires should cross only at 90° in order to minimize the coupled length between wires.
3
Optimized Layout with PanelMax™ Offering
An optimized panel layout uses PanelMax™ Shielded Wiring Duct and Noise Shield to provide noise mitigation with reduced
distance spacing required between clean and noisy pathways. PanelMax™ DIN Rail Wiring Duct is also implemented to
provide additional panel space savings.
1
5
Noise Shield
2
Sensitive
Noisy
3
Conventional
Wiring Duct
6
2
Noise Shield
4
40%+
Space Savings
Shielded
Wiring Duct
The strategy is to shield, mitigating noise between sensitive and potentially noisy wiring/cabling while reducing panel space:
1
Control and potentially sensitive wiring is routed in “clean” pathways (white color).
2
Power and potentially noisy wiring is routed in “noisy” pathways or shielded wiring duct (gray color).
3
Conventional wiring duct contains motor cabling. Noise shield is mounted separately to shield control and
network cabling.
4
Optionally, noise shield is mounted inside shielded wiring duct to segregate and shield sensitive cabling from noise.
Shielded wiring duct mitigates potential noise emission from cabling inside the duct near clean pathways.
Shielded wiring duct mitigates potential noise emission from motor drives onto the PAC device and sensitive
wiring connections.
5
6
PanelMax™ DIN Rail Wiring Duct is added to the design to provide additional space savings.t
Layout Benefits:
•Robust noise mitigation is achieved
•Shielded wiring duct and noise shield reduce panel height by over 20% and DIN Rail wiring duct reduces panel width
by over 20% resulting in significant enclosure footprint reduction
•Net value of space saved in panel/enclosure with cost of PanelMax™ Shielded Wiring Duct and Noise Shield and
DIN Rail Wiring Duct is between $1,500 and $5,000 n
tSee www.panduit.com for more information on PanelMax™ DIN Rail Wiring Duct (product
n Material cost savings potential depends on enclosure/panel type selected (e.g., standard
4
bulletin WDCB36--SA-ENG).
NEMA12 steel vs. NEMA4X stainless steel enclosures).
Ordering Information
Noise shield provides
UL508 compliant
wire separation
Cable tie slots
integrated into
shield for cable
management
Potential
noise-emitting
wiring
Durable black
powder coat for smooth
edges
Durable metallic
foil shield covers base
and side walls
Potential
noise-emitting
wiring
Vertical wire
slots for wire
pass-through
Horizontal bridge
connectors provide
continuity to
ground plane
Bonding clip
allows shield
use within
wiring duct
Uncoated conductive
zinc-plated surface (top/
bottom) for
electrical bond
Sensitive
communications
cable
Sensitive wiring
Ordering Information
Part Number
G2X2LG6EMI
Part Description
2" x 2" PanelMax™ Shielded Wiring Duct; 6-foot length. Foil metal
finish includes anti-oxidizing paste. Cover sold separately.
G2X3LG6EMI
2" x 3" PanelMax™ Shielded Wiring Duct; 6-foot length. Foil metal
finish includes anti-oxidizing paste. Cover sold separately.
G2X4LG6EMI
2" x 4" PanelMax™ Shielded Wiring Duct; 6-foot length. Foil metal
finish includes anti-oxidizing paste. Cover sold separately.
Std.
Pkg.
Qty.
12
12
12
Use C2LG6 or C2WH6 cover with shielded wiring duct. Standard package quantity in feet.
PanelMax™ Shielded Wiring Duct
PanelMax™ Noise Shield and
Bonding Clips
Part Number
SD2EMI
Part Description
EMI noise shield kit for 2" height Panduit wiring duct; two 3-foot
sections, four bonding clips, and anti-oxidizing paste.
SD3EMI
EMI noise shield kit for 3" height Panduit wiring duct; two 3-foot
sections, four bonding clips, and anti-oxidizing paste.
SD4EMI
EMI noise shield kit for 4" height Panduit wiring duct; two 3-foot
sections, four bonding clips, and anti-oxidizing paste.
SDCLIP
Noise shield replacement bonding clips – 2 clips.
Std.
Pkg.
Qty.
1
1
1
1
Standard package quantity in kits.
Noise Shielding Effectiveness in dB
Performance Characteristics
Relative noise reduction in decibels over
frequency range of Panduit ® PanelMax ™
Shielded Wiring Duct and Noise Shield
Noise Shielding Performance
0.00
-5.00
-
--10.00
No Shield
--15.00
Panduit ® PanelMax™
Shielded Products
--20.00
90%NVR*
-25.00
0
1
2
3
4
5
6
7
Frequency in Mhz
8
9
10
PanelMax ™ Shielded Wiring Duct and Noise Shield deliver approximately
20dB of noise reduction across common industrial noise frequencies at
30mm wire separation with an approximate 1-meter coupling length.
*NVR (Noise Voltage Reduction percentage).
5
Technical Information
PanelMax ™ Noise Shield
.30
[7.6]
2.00
[50.8]
GAP
.16 [4.2]
.50 [12.7]
TYP.
1.00 1.00
[25.4] [25.4]
X
1.50
[38.1]
.20
[5.0]
.75 [19.0]
.96
[24.4]
.52 [13.3]
.80
[20.3]
Part No.
SD2EMI
X — Inches (mm)
1.82 (46.1)
SD3EMI
2.88 (73.2)
SD4EMI
3.86 (98.2)
2.62
[66.6]
Sidewall: SD3EMI shown.
SD2EMI sidewall features one pair of
cable tie slots per section.
.20 [5.0] TYP.
Bottom view.
Bonding clip (for use with
wiring duct).
PanelMax ™ Shielded Wiring Duct
C
.84 [21.3]
.84 [21.3]
F
T
.57 [14.5]
.70 [17.8]
B
H D
.48 [12.1]
.33 [8.4]
A
2x3 sidewall
E
2x2 sidewall
Dimensions – Inches (mm)
.50 [12.7] TYP.
.20 [5.0] TYP.
CL
Part Number
A
2.25
(57.2)
2.25
(57.2)
2.25
(57.2)
G2X2LG6EMI
K
K
2.00
[50.8]
2x4 sidewall
G2X3LG6EMI
4.00
[101.6] TYP.
G2X4LG6EMI
B
2.12
(53.8)
3.12
(79.2)
4.10
(104.1)
C
2.25
(57.2)
2.25
(57.2)
2.25
(57.2)
D
1.61
(41.0)
2.64
(67.0)
3.62
(91.9)
E
0.31
(7.9)
0.31
(7.9)
0.31
(7.9)
F
0.80
(20.3)
1.00
(25.4)
1.00
(25.4)
H
2.00
(50.8)
3.00
(76.2)
4.00
(101.6)
K
0.50
(12.7)
0.50
(12.7)
0.50
(12.7)
T
0.08
(2.0)
0.10
(2.4)
0.11
(2.7)
PanelMax ™ Shielded Wiring Duct Wire Fill
Electrical
10
8 AWG AWG
Part Number
G2X2LG6EMI
G2X3LG6EMI
G2X4LG6EMI
Nominal
Area in2
4.000
6.000
8.000
12
AWG
Communication
14
AWG
23
AWG
23/24
AWG
0.216 0.164 0.130 0.141 0.152 0.111 0.124 0.133 0.096 0.111 0.118 0.084 0.100 0.106 0.085
0.330
THHN THHN THHN MTW
48
84
135 114
73
127 202 172
97
169 270 229
Cat 6A
20
31
41
MTW THHN MTW
98
185 148
148 278 222
197 371 297
16
AWG
MTW
129
193
258
TFFN
248
372
496
MTW
185
278
371
18
AWG
MTW TFFN MTW
164 323 228
246 485 342
328 647 457
22
AWG
MTW MTW
203 316
305 474
406 632
24
AWG
Fiber
Cable
0.250
0.190
0.118
Cat 6
36
54
73
Cat 5e 3.0 mm
63
163
94
245
126
327
Table shows maximum wire fill based on 50% of duct internal cross sectional area. Formula = Nominal Area / 1.75xD2. All dimensions represent typical outer cable diameter in inches.
Related products
NR1 Nylon Rivet
For use with TNR tool
TNR Nylon Rivet
Installation Tool
Hand-held tool for easy
rivet installation
DNT-100 Notching Tool
Notches duct sidewalls to
bottom scoreline for tees
and corners
DCT Tool
Provides a smooth
burr-free cut on both
wiring duct and cover
CWST Tool
Snipping tool cuts
conductors flush for
improved performance
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT CANADA
Markham, Ontario
[email protected]
Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK
[email protected]
Phone: 44.20.8601.7200
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
[email protected]
Phone: 65.6305.7575
PANDUIT JAPAN
Tokyo, Japan
[email protected]
Phone: 81.3.6863.6000
PANDUIT LATIN AMERICA
Guadalajara, Mexico
[email protected]
Phone: 52.33.3777.6000
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
[email protected]
Phone: 61.3.9794.9020
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
For more information
Visit us at www.panduit.com
Contact Customer Service by email: [email protected]
or by phone: 800.777.3300 and reference WDCB26
©2016 Panduit Corp.
ALL RIGHTS RESERVED.
WDCB26--SA-ENG
replaces SA-WDCB23
3/2016