PB314 Series 6 3 6 - 7 4 5 W AT T S B AT T E R Y C H A R G E R S Y S T E M FEATURES • • • • • • • 636 - 745W PSU for Battery Backup DC UPS Connectable Constant Float Voltage & Current Limit Circuit Breaker & Alarm Relays Optional LVD - Low Volts Battery Disconnect OPERATIONS & INSTALLATION HANDBOOK AVAILABLE SPECIFICATIONS INPUT Input Voltage DISPLAYS AND ALARMS DC OK LED Green On = OK, Voltage-free changeover contact (32V, 1A).Alarm on failure of AC/DC PSU and tripping of over temperature limit. AC OK LED Green On = OK, Voltage-free changeover contact (32V, 1A). Alarm on mains fail. Battery Ok LED Green On = OK, Voltage-free changeover contact(32V, 1A). Alarm on battery low voltage or on opening of battery circuit breaker. 85-264Vac or 120-360Vdc Frequency: 47 to 63 Hz Input Current: 4.1A typical at 200Vac Inrush current: 40A typical cold start 200Vac Line regulation 60mV maximum OUTPUT Output Voltage 13.8Vdc, 27.6Vdc Output Power 636W - 745W Output Current See Selection Table Efficiency Battery low alarm voltage -11.0Vdc 79% typical Battery Low Voltage Disconnect Option LVD: Battery LVD disconnect 10.5V Battery LVD reconnect 12.0Vdc Load regulation 1% typical Voltage meter 0 to 15Vdc Ripple 160mVp-p max Load current meter 0 to 100A Noise 180mVp-p max Battery current meter -100A to +100A scale. PROTECTION OPTIONAL FEATURES Overvoltage shutdown 16.2 to 19.8V latching Output short circuit Indefinite protection (Autoresetting) Battery Charge Limit Option BCL: Specify battery charge current based on battery size. Battery LVD disconnect Option LVD: For 12V and 24V models, not available in 48V models. Battery charger short circuit Indefinite protection (Autoresetting) Load output protection Thermal - Magnetic Circuit Breaker Battery output protection Thermal - Magnetic Circuit Breaker. Isolation Input - Output: 3KVac 1 min Input - Ground: 2KVac 1 min Output - Ground: 500Vac 1min ENVIRONMENT Operating temperature -20°C to 71°C Derating from 50°C to 71°C to 50% power Humidity 20-90% relative humidity (non condensing) Cooling Forced cooling - internal fan STANDARDS & APPROVALS C-Tick AS/NZS CISPR11 Group 1 Class A. Safety UL 60950 Class 1 EMC Emissions comply with AS/NZ CISPR22 Class-B MECHANICAL AC input socket IEC320 fused / on off switch Output termination Hirose connector (-H version) Cage clamp terminals (-C version) Alarm relay contacts DB25 socket Load fault current proteciton breaker 63 A Battery fault current protection breaker 63 A Rack mount size 264 L x 172 W x 67 H mm Weight 5.0Kg Doc. No. PB314 Series Rev.L 09-06-16 PB314 Series 6 3 6 - 7 4 5 W AT T S B AT T E R Y C H A R G E R S Y S T E M SELECTION TABLE MODEL NUMBER OUTPUT VOLTAGE OUTPUT CURRENT BATTERY CHARGE CURRENT POWER OUTPUT CONNECTOR PB314-12-43-H 13.8Vdc 43A Balance of load current 645W Hirose PB314-12-43-C 13.8Vdc 43A Balance of load current 645W Cage clamp PB314-12-53-H 13.8Vdc 53A Balance of load current 636W Hirose PB314-12-53-C 13.8Vdc 53A Balance of load current 636W Cage clamp PB314-24-27-H 27.6Vdc 27A Balance of load current 745W Hirose PB314-24-27-C 27.6Vdc 27A Balance of load current 745W Cage clamp Notes 1. Battery Charge Current is the remainder balance of Load Current. 2. BCL option, specifies battery charge current limit recommended on battery size. 3. LVD option, Low Voltage Battery Disconnect. TECHNICAL ILLUSTRATIONS Doc. No. PB314 Series Rev.L 09-06-16 Powering Progress – www.powerbox.com.au PB314 Series 6 3 6 - 7 4 5 W AT T S B AT T E R Y C H A R G E R S Y S T E M Doc. No. PB314 Series Rev.L 09-06-16