HRP-600 600W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.94 High efficiency up to 89% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Built-in constant current limiting circuit Built-in cooling fan ON-OFF control Built-in DC OK signal Built-in remote sense function All using 105 long life electrolytic capacitors 5 years warranty SPECIFICATION MODEL OUTPUT HRP-600-3.3 HRP-600-5 DC VOLTAGE 3.3V 5V 7.5V 12V 15V RATED CURRENT 120A 120A 80A 53A 43A CURRENT RANGE 0 ~ 120A 0 ~ 120A 0 ~ 80A 0 ~ 53A 0 ~ 43A RATED POWER 396W 600W 600W 636W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p VOLTAGE ADJ. RANGE 4.3 ~ 5.8V 2.0% 6.8 ~ 9V 2.0% 2.8 ~ 3.8V VOLTAGE TOLERANCE Note.3 2.0% HRP-600-24 HRP-600-36 HRP-600-48 24V 36V 48V 27A 17.5A 13A 0 ~ 27A 0 ~ 17.5A 0 ~ 13A 645W 648W 630W 624W 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p 10.2 ~ 13.8V 1.0% 13.5 ~ 18V 1.0% 21.6 ~ 28.8V 1.0% 28.8 ~ 39.6V 1.0% 40.8 ~ 55.2V 1.0% 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load PF>0.94/230VAC EFFICIENCY (Typ.) 78.5% 8.5A/115VAC 35A/115VAC LEAKAGE CURRENT <1.2mA / 240VAC OVER VOLTAGE 2500ms, 50ms/115VAC at full load 120 ~ 370VDC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) OVERLOAD FUNCTION HRP-600-15 LOAD REGULATION POWER FACTOR (Typ.) PROTECTION HRP-600-12 LINE REGULATION VOLTAGE RANGE Note.5 85 ~ 264VAC 47 ~ 63Hz FREQUENCY RANGE INPUT HRP-600-7.5 PF>0.99/115VAC at full load 87% 82% 88% 88% 88% 89% 89% 41.4 ~ 48.6V 57.6 ~ 67.2V 5A/230VAC 70A/230VAC 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover 80 5 OVER TEMPERATURE 90 5 (TSW1)detect on heatsink of power transistor DC OK SIGNAL Protection type : Shut down o/p voltage, recovers automatically after temperature goes down PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V FAN CONTROL (Typ.) Load 35 15% or RTH2 WORKING TEMP. -40 ~ +70 (TSW2) detect on heatsink of power doide for 3.3V,5V,7.5V ; 100 50 5 (TSW2) detect on main power output choke for others Fan on (Refer to "Derating Curve") 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION OTHERS I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A MTBF 140.6K hrs min. DIMENSION 218*105*63.5mm (L*W*H) 1.5Kg;8pcs/13Kg/1.34CUFT PACKING NOTE UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:HRP-600-SPEC 2011-08-09 HRP-600 600W Single Output with PFC Function Mechanical Specification Case No. 977A O/P 2 105 4 5 6 1 2 CN100 218 152.4 32.8 8-M4 L=4 (Both Sides) 12.5 38.3 18max. 63.5 12max. 3 4 LED 1 2 3 SVR1 (Vo ADJ.) 8.2 9.2 63.5 3 I/P 10 11 1 4-M4 L=6 Air flow direction Unit:mm 32.8 20.75 152.4 series AC Input Terminal Pin No. Assignment Pin No. 1 2 3 Connector Pin No. Assignment(CN100) : HRS DF11-4DP-2DS or equivalent DC Output Terminal Pin No. Assignment Assignment AC/L AC/N FG Pin No. 1~3 4~6 Pin No. Assignment DC-OK GND +S -S 1 2 3 4 Assignment -V +V Mating Housing Terminal HRS DF11-4DS HRS DF11-**SC or equivalent or equivalent Block Diagram PW M fosc : 70KHz EMI FILTER I/P +S ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC RECTIFIERS & FILTER POWER SWITCHING +V -V -S O.L.P. O.T.P. FG PFC CONTROL DETECTION CIRCUIT PWM CONTROL Derating Curve DC OK O.T.P. O.V.P. Output Derating VS Input Voltage 100 125 90 100 80 70 LOAD(%) LOAD (%) 80 50 20 -40 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 65 70 (HORIZONTAL) 60 50 40 85 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:HRP-600-SPEC 2011-08-09