Blade Enclosure M - December 8, 2015

NEC Blade Enclosure M
System Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The
guide will ensure fast and proper configuration of your NEC Express5800 server.
December 8, 2015
Revision 3.1
NEC Corporation
SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure M
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Key Features .......................................................................................................................................... 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 4
Front View .............................................................................................................................................. 4
Rear View ............................................................................................................................................... 4
Dimensions (mm) .................................................................................................................................. 5
CONFIGURATION DIAGRAM ......................................................................................... 5
SYSTEM CONFIGURATION ........................................................................................... 6
1
2
3
4
5
6
7
8
Enclosure........................................................................................................................................ 6
Installable Blades .......................................................................................................................... 6
Switch Module / Pass-Through Card ........................................................................................... 8
3.1
Network Switche and Pass-Through Card........................................................................... 9
3.2
Fibre Channel Switch and Pass-Through Card ................................................................. 10
Enclosure Management Card ..................................................................................................... 11
Power Supply Module ................................................................................................................. 12
Cooling Fan .................................................................................................................................. 13
Optical Drive ................................................................................................................................. 13
Add-on Components ................................................................................................................... 13
8.1
Front Bezel ......................................................................................................................... 13
8.2
Flash FDD .......................................................................................................................... 13
8.3
17-inch LCD Console Drawer ............................................................................................ 13
8.4
KVM Switch ........................................................................................................................ 14
8.5
SUV Cable ......................................................................................................................... 14
REFERENCES............................................................................................................... 15
Product Overview ................................................................................................................................ 15
Enclosure Management Card ........................................................................................................ 15
1Gb Intelligent L3 Switch ............................................................................................................... 17
1:10Gb Intelligent L3 Switch .......................................................................................................... 19
10Gb Intelligent L3 Switch ............................................................................................................. 21
10Gb Intelligent L3 Switch ............................................................................................................. 23
1Gb Pass-Through Card ................................................................................................................ 25
10Gb Pass-Through Card .............................................................................................................. 26
1Gb Interlink Expansion Card ........................................................................................................ 27
8G FC switch (12 ports) ................................................................................................................. 29
Copyright Notice and Liability Disclaimer ........................................................................................ 30
REVISION HISTORY ..................................................................................................... 31
NEC Corporation
Revision 3.1 – December 8, 2015
2
SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure M
Technical Specification
Key Features



High capability with eight server/storage blades bays and six switch modules bays
High reliability by redundant enclosure management card, power supply, and cooling fan
Full manageability by enclosure management card
Specification
Model
Part Number
Number of Bays
Internal Storage
Blade Enclosure M
Blades
Switch Modules
Enclosure Management Card
Power Supply
Cooling Fan
Optical Disk Drive
Interfaces
Server Management
Redundant Server Management Controller
Redundant Fan
Redundant Power Supply
Power Supply
Maximum Power Consumption
Dimensions (W x D x H )
Weight (Maximum)
Temperature, Relative Humidity
(non-condensing)
Regulatory and Safety Standards
NEC Corporation
N8405-016BF
8
6
2
4
5
DVD-ROM drive
Read speed: DVD 8X maximum, CD 24X maximum
1 Keyboard (6-pin mini DIN, 1 rear)
1 Mouse (6-pin mini DIN, 1 rear)
1 VGA (15-pin mini D-sub, 1 rear)
1 USB2.0 (1 rear)
1 Serial (9-pin D-sub, 1 rear)
Enclosure Management Card
Optional, hot plug
Optional, hot plug
Optional, hot plug
100-240 VAC ± 10% 50 / 60 Hz ± 1 Hz
6,301 VA / 6,175 Watt
484.8 x 829 x 264.2 mm (6U) / 19.0 x 32.6 x 10.4 in
125 kg, 275.57 lbs.
Operating: 10° to 35° C / 50° to 95° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
FCC, CE, CCC, UL, CB, RoHS, WEEE
Revision 3.1 – December 8, 2015
3
External Views
Front View
A
1
1
2
1
2
ID
1
1
2
ID
1
2
2
ID
1
2
ID
ID
1
2
ID
2
ID
ID
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
E
B
C
D
E
Legend
A.
B.
C.
Server/Storage Blade Bays
DVD-ROM Drive
Control Panel
D.
E.
USB Connector
Power Supply Bays
F.
G.
H.
I.
J.
VGA Connector
Enclosure Management LAN Connectors
Keyboard Connector
Mouse Connector
UPS Connectors
Rear View
A
B
C
C
C C
D
J
E
F
G
H
I
Legend
A.
B.
C.
D.
E.
Cooling Fan Bays
Switch Module Bays
AC Inlet
Blade Enclosure Interconnect Connectors
Serial Connector
NEC Corporation
Revision 3.1 – December 8, 2015
4
441.4
Dimensions (mm)
30
22
777
113.95
209.7
264.2
88
24
484.8
Configuration Diagram
Power
Supply
#1
Power
Supply
#2
Optical Drive
EM Card #1
EM Card#2
Control
Panel
Legend:
NEC Corporation
Server Blade
Bay #8
Server Blade
Bay #7
Server Blade
Bay #6
Server Blade
Bay #5
Server Blade
Bay #4
CHASSIS
REAR
Server Blade
Bay #3
Server Blade
Bay #2
Server Blade
Bay #1
CHASSIS
FRONT
Cooling
Fan
#5
Cooling
Fan
#4
Cooling
Fan
#3
Cooling
Fan
#2
Cooling
Fan
#1
Switch Module Bay #5
Switch Module Bay #6
Switch Module Bay #3
Switch Module Bay #4
Switch Module Bay #1
Switch Module Bay #2
Power Power
Supply Supply
#3
#4
Standard Components
Mandatory components
Revision 3.1 – December 8, 2015
5
System Configuration
1 Enclosure
Product Name / Description
Part Number
Blade Enclosure M
6U height enclosure
N8405-016BF
2 Installable Blades
Available sockets: 8
Category
Product Name
Part Number
Server
NEC Express5800/B120f-h
NEC Express5800/B120f
NEC Express5800/B120e
NEC Express5800/B120e-h
NEC Express5800/B110d
NEC Express5800/B120d
NEC Express5800/B120d-h
NEC Express5800/B120b
NEC Express5800/B120b-d
NEC Express5800/B120b-h
NEC Express5800/B120a
NEC Express5800/B120a-d
AD106c
AD106b
AD106a
AT101b
Slot Cover(Server Blade)
N8405-032
Storage
and I/O
Tape
Bay Cover
NOTE:

To configure the blades, refer to the Configuration Guide of each blade.

For efficient cooling, all vacant slots must be covered with a Slot cover.
NEC Corporation
Revision 3.1 – December 8, 2015
6
Server Blade and Storage/Tape Installation Guideline
See the figures below to install the blades.
One-bay height server blades:

Server blades can be installed into any bay.
1
1
1
1
1
1
1
2
2
2
2
2
2
2
ID
ID
ID
ID
ID
ID
ID
1
2
0
1
3
0
1
4
0
1
5
0
6
0
1
1
1
2
ID
7
0
1
8
0
1
0
1
One-bay height server blades paired with storage or tape blades:

Install sets of Server blades and their direct attached storage/tape blades into paired adjacent bays as
below.
1
1
1
1
1
1
1
2
2
2
2
2
2
2
ID
ID
ID
ID
ID
ID
ID
0
1
1
NEC Corporation
0
0
1
1
2
0
0
1
1
3
1
2
ID
0
0
1
1
4
0
1
Revision 3.1 – December 8, 2015
7
3 Switch Module / Pass-Through Card
Switch Modules / Pass-Through Cards and Installable Bays
See the table below for installable switches or cards and bay number. The paired bays (1-2, 3-4, 5-6) must
have the same modules or cards installed.
Switch Module Bays
Part Number
N8406-023AF
N8406-044F
N8406-051F
N8406-052F
N8406-011
N8406-013
N8406-035F
N8406-040F
N8406-021
1
Bay # : Product Name
#1 / #2
#3 / #4





-
1Gb Intelligent L3 Switch
1:10Gb Intelligent L3 Switch
10Gb Intelligent L3 Switch
10Gb Intelligent L3 Switch
1Gb Pass-Through Card
1Gb Interlink Expansion Card
10Gb Pass-Through Card
8G FC switch (12 ports)
4G FC Pass-Through Card





1
 



#5 / #6








N8406-023AF 1Gb Intelligent L3 Switch must be installed into bay #1 and #2 when installing N8406-013 1Gb
Interlink Expansion Card.
Switch Module Bay Positions
Bay #5
Bay #3
Bay #1
Bay #6
Bay #4
Bay #2
Network Port and Switch Module Bay Interconnection
See the tables below for the network port and switch module bay interconnection. Because the blades in
the enclosure share switch modules or pass-through cards, all blades must have I/O expansion cards of
the same interface installed in the same bay to correspond with the switch modules.
Blade Port Type
Port
Embedded NIC
Expansion Slot 1 Type 1
I/O Expansion Card
excluding N8403-049F
Quad Port 10GbE Adapter
N8403-049F Quad Port
10GbE Adapter
Expansion Slot 2 Type 2
I/O Expansion Card
excluding N8403-024
10GbE (2ch) Adapter and
N8403-049F Quad Port
10GbE Adapter
N8403-024 10GbE(2ch)
adapter
N8403-049F Quad Port
10GbE Adapter
NEC Corporation
Port 1
Port 2
Port 1
Port 2
Port 1 and Port 2
Port 3 and Port 4
Port 1
Port 2
Port 3
Switch Module Bays
Bay #1
Bay #2
Bay #3
Bay #4
Port 4
Bay #3
Bay #4
Bay #5
Bay #6
Bay #5
Bay #6
Port 1
Port 2
Port 1 and Port 2
Port 3 and Port 4
Bay #5
Bay #6
Bay #5
Bay #6
Revision 3.1 – December 8, 2015
8
3.1
Network Switche and Pass-Through Card
Category
GbE
10GbE
NEC Corporation
Product Name / Description
Part Number
Switch
1Gb Intelligent L3 Switch
Uplink : 5 1000BASE-T (RJ-45), 4 1000BASE-SX (SPF)
NOTE:
- N8406-024 1000BASE-SX SFP Module is required for each
port to connect an optical cable.
- 4 ports of 1000BASE-SX and 4 ports of 1000BASE-T are
mutually exclusive.
- K410-84(05) Ethernet crossover cable is recommended to
configure a switch.
N8406-023AF
Card
1Gb Pass-Through Card
Uplink : 16 1000BASE-T (RJ-45)
NOTE:
- The card supports only 1 Gbps link speed.
1Gb Interlink Expansion Card
Interlink : 16 1000BASE
NOTE:
- N8406-023AF 1Gb Intelligent L3 Switch must be installed into
bay #1 and #2 when installing the card.
- The card supports N8403-017 1000BASE-T(2ch) adapter and
N8403-021 1000BASE-T(2ch) adapter only.
N8406-011
10Gb Intelligent L3 Switch
Uplink :8 10GBASE-SR (SFP+)
Downlink:16
NOTE:
- Interconnection with N8403-024 10GbE adaptor (2ch) is not
supported.
- The following SFP Module is required for each port to connect
a cable:
N8406-024 1000BASE-SX SFP Module
N8406-037 10GBASE-SR SFP+ Module
N8406-039 1000BASE-T SFP Module
- A Inter-link connection is supported with a backplane to
connect with switches installed into horizontally adjacent bays.
To connect with switches not installed into horizontally
adjacent bays, K410-203(03) 10GSFP+ Cable is required.
N8406-051F
10Gb Intelligent L3 Switch
Uplink : 8 10GBASE-SR (SFP+), 2 40GBASE-SR (QSFP+)
Downlink : 32
NOTE:
- Interconnection with N8403-024 10GbE adaptor (2ch) is not
supported.
- The following SFP Module is required for each port to connect
a cable when using an SFP Module slot:
N8406-024 1000BASE-SX SFP Module
N8406-037 10GBASE-SR SFP+ Module
N8406-039 1000BASE-T SFP Module
- The following QSFP Module is required for each port to
connect a cable when using a QSFP Module slot:
N8406-053 40GBASE-SR QSFP+ Module
- An Inter-link connection is supported with a backplane to
connect with switches installed into horizontally adjacent bays.
To connect with switches not installed into horizontally
adjacent bays, K410-203(03) 10GSFP+ Cable is required
when using an SFP Module slot and K410-235 (03) 40G
QSFP Cable or K410-236(03) 40G QSFP-10G SFP+ x4 Cable
is required when using a QSFP Module slot.
- The switch is make-to-order product. Please consult our sales
N8406-052F
Switch
Revision 3.1 – December 8, 2015
N8406-013
9
representative in regard to production lead time.
1:10Gb Intelligent L3 Switch
Uplink : 2 10GBASE-SR (XFP), 4 1000BASE-T (RJ-45)
NOTE:
- N8406-027 10GBase-SR XFP Module is required for each
port to connect an optical cable.
- K410-84(05) Ethernet crossover cable is recommended to
configure a switch.
- The interconnection speed to server blades is 1Gbps
Card
10Gb Pass-Through Card
Uplink :16 10GBASE-SR (SFP+)
NOTE:
- Interconnection with N8403-024 10GbE adaptor (2ch) is not
supported.
- The following SFP Module is required for each port to connect
a cable:
N8406-024 1000BASE-SX SFP Module
N8406-037 10GBASE-SR SFP+ Module
N8406-039 1000BASE-T SFP Module
- The card supports only 1 Gbps and 10 Gbps link speed.
- To connect to an external network, route through external
switch.
N8406-044F
N8406-035F
NOTE:

For standard NIC connection, select either the 1Gb Intelligent L3 Switch, 1:10Gb Intelligent L3 Switch,
10Gb Intelligent L3 Switch, 1Gb Pass-Through Card or 10Gb Pass-Through Card.

To activate both NIC ports of a server blade, a pair of a switch or card is required.
3.2
Fibre Channel Switch and Pass-Through Card
Category
8Gb
Switch
Product Name / Description
Part Number
8G FC switch (12 ports)
8 downlink, 4 uplink, including 2 SFP+ modules
NOTE:
- Up to 8 blades installed into the upper blade bays can be
connected to the switches.
- N8406-041 4G/8G SFP+ modules must be ordered if three or
more modules are needed.
- The switch supports only 4 and 8 Gbps link speed.
N8403-040F
NOTE:

Link speed of two fibre channel ports in a controller in a blade must be the same.

To activate two fibre channel ports of a dual channel fibre channel controller in a server blade, a pair of
a switch or card is required.
NEC Corporation
Revision 3.1 – December 8, 2015
10
4 Enclosure Management Card
Available bays: 2
Product Name / Description
Part Number
Enclosure Manager Card
N8405-019A
NOTE:



Minimum one enclosure management card must be installed.
Install two cards for redundancy.
The Management LAN Connector supports auto negotiation only. Attention is required when
configuring settings to the external switch connected to this connector.
Supporting Virtual IO control
See the tables below for the blades and optional NICs that support the feature.
Category
Part Number
Server Blades
B120f B120f-h
1 ,
1
B120e , B120e-h
1
1
1
B120d , B110d , B120d-h
2
B120b, B120b-d, B120b-h
B120a, B120a-d
AD106c, AD106b, AD106a, AT101b
N8403-018
Fibre Channel Controller(4Gbps/2ch)
N8403-034
Fibre Channel Controller(8Gbps/2ch)
3
N8403-021
1000BASE-T(2ch) adapter (for iSCSI)
3
N8403-022
1000BASE-T(4ch) adapter (for iSCSI)
N8403-035
10GBASE-KR LAN interface card
N8403-065F Dual Port 10GBASE Adapter
N8403-067F Dual Port 10GBASE Adapter(for iSCSI)
N8403-084F Dual Port 10GBASE Adapter
N8403-085F Dual Port 10GBASE Adapter
N8403-049F Quad Port 10GBASE Adapter
N8403-051F Quad Port 10GBASE Adapter
Storage and Tape Blades
Optional NICs
1
1
1
Supports only on the flexible integrated NICs.
2
Not support in PXE Boot configuration
3
Not support on the following operating systems:
Red Hat Enterprise Linux : 5.6, 5.7, 6.0, 6.1
VMWare ESX/ESXi : 4.0 Update3 or later, 4.1 Update1, 4.1 Update2, 5.0
NEC Corporation
Revision 3.1 – December 8, 2015
11
5 Power Supply Module
Available bays: 4
Product Name / Description
Part Number
Power Unit
2,250 Watt (200VAC), 985 Watt (100VAC)
N8405-055F
NOTE:

Minimum two power units must be installed.
Number of Required Power Supplies
See the table below for the number of power supplies required according to maximum power consumption.
Maximum power consumption can be calculated by adding the power consumption of each server/storage
blade, the power consumption of each switch modules/pass-through cards and the power consumption of
blade enclosure, 370 Watts
200VAC Input
Maximum Power
Consumption (VDC / Watt)
Number of Power
Supplies (N+1)
Number of Power
Supplies (N+N)
Up to 2244
Up to 4260
2
3
2
4
100VAC Input
Maximum Power
Consumption (VDC / Watt)
Number of Power Supplies (N+1)
Up to 1044
Up to 1980
Up to 2964
2
3
4
NEC Corporation
Revision 3.1 – December 8, 2015
12
6 Cooling Fan
Available bays: 5
Product Name / Description
Part Number
Fan Unit
N8405-053F
NOTE:

Minimum three fan units must be installed as indicated below.
Number of Required Fan Units
See the figure below for the number of fan units required according to the number of blades installed.
3 fans 4 fans
1
1
1
5 fans
1
1
1
1
2
2
2
2
2
2
2
ID
ID
ID
ID
ID
ID
ID
0
1
1
0
0
1
1
2
0
0
0
1
1
1
1
2
ID
3
0
0
1
1
7 Optical Drive
Product Name / Description
Part Number
Internal Slim DVD-ROM drive
Slim DVD-ROM drive
(Standard)
8 Add-on Components
8.1
Front Bezel
Product Name / Description
Part Number
Front Bezel
N8405-033
8.2
Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for floppy drive.
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-96
8.3
17-inch LCD Console Drawer
Category
Drawer
w/o KVM
NEC Corporation
Drawer
Product Name / Description
Part Number
17inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height,
4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m,
15-pin mini D-sub VGA cable 2 m
N8143-76F
Revision 3.1 – December 8, 2015
13
8.4
KVM Switch
Category
Product Name / Description
Part Number
KVM Switch
Server Switch Unit (8 server)
1U USB 8 port KVM switch
Switch Unit Connection Cable Set (PS/2,1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 2 x PS/2
Switch Unit Connection Cable Set (PS/2,3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 2 x PS/2
Switch Unit Connection Cable Set (PS/2,3m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 2 x PS/2
Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub to 1x 15-pin mini D-Sub / 2x PS/2
N8191-12F
Cable
KVM
Cascading
8.5
K410-119(1A)
K410-119(03)
K410-119(05)
K410-119(1A)
SUV Cable
Product Name / Description
Part Number
SUV Cable
1 x SUV to 1 x 15-pin mini D-sub, 1 x USB, 1 x 9-pin D-sub
K410-150(00)
NOTE:

One cable is included in the blade enclosure.
NEC Corporation
Revision 3.1 – December 8, 2015
14
References
Product Overview
Enclosure Management Card
The enclosure management card provides the following management feature:
Web console integration
The enclosure management card web console displays a list of the Blade Enclosure H v2 / -M enclosures
that are installed in the same rack cabinet. Via the list, the web consoles of other enclosures are available
to view.
Power capping management
For power consumption control, a maximum power consumption value can be set through the enclosure
management card for each enclosure or for the whole blade enclosure group in the same rack.
vIO Control
The Virtual IO control feature virtualizes the MAC address / WWN / UUID / serial number of server blades.
Specification
Model
Enclosure Management Card
Part Number
Features
N8405-043
Power supply management
Cooling management
Enclosure management
System status monitoring
Redundancy
Switch module configuration
Web console integration
Power capping management
Enclosure web console management
1
vIO control
1 Serial (9-pin D-sub)
2
(1) 100BASE-T (RJ-45)
0.3 kg, 0.66 lbs.
5.5 Watt
Interface
Weight (Maximum)
Maximum Power Consumption (VDC)
1
Requires EMFW 05.00 or later
2
Supports only automatic negotiation
Front View
A
B C D
E
F
G
H
NEC Corporation
I
Revision 3.1 – December 8, 2015
15
Legend
A.
B.
C.
D.
E.
Reset Button
System Status LED
Active LED
ID LED
ID Button
NEC Corporation
F.
G.
H.
I.
Serial Port Connector
LAN Connector
Link/active LED
Speed LED
Revision 3.1 – December 8, 2015
16
1Gb Intelligent L3 Switch
Specification
Model
Part Number
Performance
Interface
1Gb Intelligent L3 Switch
Switching capacity
MAC address
Forwarding method
Forwarding rate
Downlink
Inter-switch
1
Uplink
Other
Features
Specifications
Management
Interface
Supported NIB
Weight (Maximum)
Card Size
Maximum Power Consumption (VDC)
1
N8406-023AF
48 Gbps
up to 8K address (per module)
Store and Forward
1,488,095 pps per port
(16) 1000BASE-X
(2) 1000BASE-X
(5) 1000BASE-T (RJ-45), (4) 1000BASE-SX (SFP)
1 Serial
Layer 2 Switch function
Layer 3 Switch function
VLAN (Port/Tag/Private)
Spanning tree (STP, RSTP, MSTP, PVRST)
Link aggregation (static, LACP)
Trunk failover (original)
QoS
ACL (Access Control List)
Jumbo frame (up to 9K)
Port mirroring
Auto MDI / MDI-X
IGMP snooping (v1, v2, v3)
NTP client
DNS client
Syslog
802.1x
RADIUS
TACACS+
SNMP v1, v2c, v3
RMON (Group 1, 2, 3, 9)
Routing protocol (static, RIPv1, RIPv2, OSPF)
VRRP
IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3ac,
IEEE802.3ad, IEEE802. 1D, IEEE802.1W, IEEE802.1s,
IEEE802.1Q
Web Console, telnet/ssh, serial console
SNMPv1 (RFC 1157)
MIB-II (RFC 1213)
Bridge-MIB (RFC 1493)
Interface MIB (RFC 2863)
Ethernet MIB (RFC 1643)
RMON v1 (RFC 1757) Group 1, 2, 3, 9
2 kg, 4.41 lbs.
1 bay width
30 Watt
4 ports of 1000BASE-SX and 4 ports of 1000BASE-T are mutually exclusive.
NEC Corporation
Revision 3.1 – December 8, 2015
17
Front View
A
B
E
C
F
D
C
G
F
G
H
Legend
A.
B.
C.
D.
ID LED
Serial Connector
RJ-45 Connectors
SFP Connectors
NEC Corporation
E.
F.
G.
H.
Status LED
Link/active LED
Speed LED
Reset Button
Revision 3.1 – December 8, 2015
18
1:10Gb Intelligent L3 Switch
Specification
Model
Part Number
Performance
Interface
1:10Gb Intelligent L3 Switch
Switching Capacity
MAC Address
Forwarding Method
Forwarding Rate
Downlink
Inter-switch
Uplink
Other
Features
Specifications
Management
Interface
Supported NIB
Weight (Maximum)
Card Size
Maximum Power Consumption (VDC)
NEC Corporation
N8406-044F
122 Gbps
up to 8K address per module
Store and Forward
1Gbps port : 1,488,095 pps per port
10Gbps port : 14,880,950 pps per port
(16) 1000BASE-X
(1) 10GBASE-X
(2) 10GBASE-SR (XFP), (4) 1000BASE-T (RJ-45)
1 Serial
Layer 2 Switch function
Layer 3 Switch function
VLAN (Port/Tag/Protocol/Private)
Spanning tree (STP, RSTP, MSTP, PVRST)
Link aggregation (static, LACP)
Trunk failover (original)
QoS
ACL (Access Control List)
Jumbo frame (up to 9K)
Port mirroring
Auto MDI / MDI-X
IGMP snooping (v1, v2, v3)
NTP client
DNS client
Syslog
802.1x
RADIUS
TACACS+
SNMP v1, v2c, v3
RMON (group 1, 2, 3, 9)
Routing protocol (static, RIPv1, RIPv2, OSPF)
VRRP
IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3ac,
IEEE802.3ad, IEEE802.1D, IEEE802.1w, IEEE802.1s,
IEEE802.1Q
Web Console, telnet/ssh, serial console
SNMPv1 (RFC 1157)
MIB-II (RFC 1213)
Bridge-MIB (RFC 1493)
Interface MIB (RFC 2863)
Ethernet MIB (RFC 1643)
RMON v1 (RFC 1757) Group 1, 2, 3, 9
2 kg, 4.41 lbs.
1 bay width
50 Watt
Revision 3.1 – December 8, 2015
19
Front View
A
B
C
C
D
E
D
N8406-044
19
F
22
23
24
25
RST
21
20
G
G
H
I
J
Legend
A.
B.
C.
D.
E.
ID LED
Serial Connector
Link LED
XFP Connectors
RJ-45 Connectors
NEC Corporation
F.
G.
H.
I.
J.
Status LED
Active LED
Link/active LED
Speed LED
Reset Button
Revision 3.1 – December 8, 2015
20
10Gb Intelligent L3 Switch
Specification
Model
Part Number
Performance
Interface
10Gb Intelligent L3 Switch
Switching Capacity
MAC Address
Forwarding Rate
Downlink
Inter-switch
Uplink
Other
Features
Management
Interface
Supported NIB
Weight (Maximum)
Card Size
Maximum Power Consumption (VDC)
1
N8406-051F
480 Gbps
up to 128 K address per module
14.8 Mpps per port
(16) 10GBASE-X
1
(4) 10GBASE-X
1
(8) 10GBASE-SR (SFP+)
1 Serial
Layer 2 Switch function
Layer 3 Switch function
VLAN (Port/Tag/Protocol/Private)
Spanning tree (RSTP, MSTP, PVRST)
Link aggregation (static, LACP)
Trunk failover (original)
QoS
ACL (Access Control List)
Jumbo frame (up to 9K)
Port mirroring
Auto MDI / MDI-X
IGMP snooping (v1, v2, v3)
NTP client
DNS client
Syslog
802.1x
RADIUS
TACACS+
SNMP v1, v2c, v3
RMON (group 1, 2, 3, 9)
Routing protocol (static, RIPv1, RIPv2, OSPF)
VRRP
Web Console, telnet/ssh, serial console
SNMPv1 (RFC 1157)
MIB-II (RFC 1213)
Bridge-MIB (RFC 1493)
Interface MIB (RFC 2863)
Ethernet MIB (RFC 1643)
RMON v1 (RFC 1757) Group 1,2,3,9
2 kg, 4.41 lbs.
1 bay width
100 Watt
4 ports of 10GBASE-X and 4 ports of 10GBASE-SR are mutually exclusive.
NEC Corporation
Revision 3.1 – December 8, 2015
21
Front View
A
B
C D
E
N8406-051
-38-
-39-
-40-
-41-
-42-
-43-
-44-
-45RST
46-49
F
50-53
G
Legend
A.
B.
C.
D.
ID LED
Serial Connector
Link LED
Active LED
NEC Corporation
E.
F.
G.
SFP+ Connectors
Status LED
Reset Button
Revision 3.1 – December 8, 2015
22
10Gb Intelligent L3 Switch
Specification
Model
Part Number
Performance
Interface
10Gb Intelligent L3 Switch
Switching Capacity
MAC Address
Forwarding Rate
Downlink
Inter-switch
Uplink
Other
Features
Management
Interface
Supported NIB
Weight (Maximum)
Card Size
Maximum Power Consumption (VDC)
NEC Corporation
N8406-052F
1040 Gbps
up to 128 K address per module
14.8 Mpps per port
(32) 10GBASE-X
1
(4) 10GBASE-X
(8) 10GBASE-SR (SFP+), (2) 40GBASE-SR (QSFP+)
1 Serial
Layer 2 Switch function
Layer 3 Switch function
VLAN (Port/Tag/Protocol/Private)
Spanning tree (RSTP, MSTP, PVRST)
Link aggregation (static, LACP)
Trunk failover (original)
QoS
ACL (Access Control List)
Jumbo frame (up to 9K)
Port mirroring
Auto MDI / MDI-X
IGMP snooping (v1, v2, v3)
NTP client
DNS client
Syslog
802.1x
RADIUS
TACACS+
SNMP v1, v2c, v3
RMON (group 1, 2, 3, 9)
Routing protocol (static, RIPv1, RIPv2, OSPF)
VRRP
Web Console, telnet/ssh, serial console
SNMPv1 (RFC 1157)
MIB-II (RFC 1213)
Bridge-MIB (RFC 1493)
Interface MIB (RFC 2863)
Ethernet MIB (RFC 1643)
RMON v1 (RFC 1757) Group 1,2,3,9
2 kg, 4.41 lbs.
1 bay width
100 Watt
Revision 3.1 – December 8, 2015
23
Front View
A
B
C D
E
F
N8406-052
-38-
-39-
-40-
-41-
-42-
-43-
-44-
-45RST
46-49
H
50-53
G
I
Legend
A.
B.
C.
D.
E.
ID LED
Serial Connector
Link LED
Active LED
SFP+ Connectors
NEC Corporation
F.
G.
H.
I.
QSFP+ Connectors
Link/Active LED
Status LED
Reset Button
Revision 3.1 – December 8, 2015
24
1Gb Pass-Through Card
Specification
Model
1Gb Pass-Through Card
Part Number
Interface
N8406-011
1
(16) 1000BASE-X
1
(16) 1000BASE-T (RJ-45)
3 kg, 6.61 lbs.
2 bay width
23 Watt
Downlink
Uplink
Weight (Maximum)
Card Size
Maximum Power Consumption (VDC)
1
Not support 10BASE-T and 100BASE-TX connection.
Front View
AB C
AB C
1
2
ID
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
RST
D E F
Legend
A.
B.
C.
RJ-45 Connectors
Link/active LED
Speed LED
NEC Corporation
D.
E.
F.
Reset Button
ID LED
Status LED
Revision 3.1 – December 8, 2015
25
10Gb Pass-Through Card
Specification
Model
10Gb Pass-Through Card
Part Number
Interface
Downlink
Uplink
Weight (Maximum)
Card Size
Maximum Power Consumption (VDC)
N8406-035F
(8) 10GBASE-X
(8) 10GBASE-SR (SFP+)
2 kg, 4.41 lbs.
1 bay width
61 Watt
Front View
AB C
D
E
Legend
A.
B.
C.
ID LED
Status LED
Port Status LED
NEC Corporation
D.
E.
Reset Button
SFP+ Connectors
Revision 3.1 – December 8, 2015
26
1Gb Interlink Expansion Card
Specification
Model
Part Number
Interface
1Gb Interlink Expansion Card
Downlink
Interlink
Weight (Maximum)
Card Size
Maximum Power Consumption (VDC)
N8406-013
(8) 100BASE-X
(8) 100BASE-X
2 kg, 4.41 lbs.
2 bay width
1 Watt
Front View
NEC Corporation
Revision 3.1 – December 8, 2015
27
4G FC Pass-Through Card
Specification
Model
4G FC Pass-Through Card
Part Number
Interface
N8406-021
16
16 SFP
2/4
3 kg, 6.61 lbs.
2 bay width
24 Watt
Downlink
Uplink
Supported Link Speed (Gbps)
Weight (Maximum)
Card Size
Maximum Power Consumption (VDC)
Front View
A
B
B
A
ID
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
RST
C D E
Legend
A.
B.
C.
SFP Connectors
Link LED
ID LED
NEC Corporation
D.
E.
Reset Button
Status LED
Revision 3.1 – December 8, 2015
28
8G FC switch (12 ports)
Specification
Model
8G FC switch (12 ports)
Part Number
Interface
N8406-040F
8
4 x SFP
4/8
High Speed switching function
Auto routing function
Cascade connection
Zoning function
Shared Memory F / FL / E port support
2 kg, 4.41 lbs.
1 bay width
38 Watt
Downlink
Uplink
Supported Link Speed (Gbps)
Feature
Internal Architecture
Weight (Maximum)
Card Size
Maximum Power Consumption (VDC)
Front View
A
E
B
C D
F
Legend
A.
B.
C.
ID LED
Status LED
Port Status LED
NEC Corporation
D.
E.
F.
SFP Connectors
Reset Button
Active LED
Revision 3.1 – December 8, 2015
29
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries.
Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
NEC Corporation
Revision 3.1 – December 8, 2015
30
Revision History
Revision
Date
Description
3.1
December 8, 2015
Others:
Deleted BSMI from Regulatory and Safety Standards because not applicable
3.0
June 19, 2015
New products added:
Flash FDD / N8160-96
Others:
Added support information of B120f-h, N8403-051, and N8403-085
2.0
October 16, 2014
New products added:
10Gb Intelligent L3 Switch / N8406-052F
Discontinued product deleted:
2G/4G FC Path-through Card / N8406-030
Others:
Add support information of B120f server blade
Remove Flash FDD
1.1
January 16, 2014
Others:
Add support information of B120e server blade
1.0
September 13, 2013
Initial release in new format
NEC Corporation
Revision 3.1 – December 8, 2015