NEC Blade Enclosure H v2 System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. December 8, 2015 Revision 3.1 NEC Corporation SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 4 Front View .............................................................................................................................................. 4 Rear View ............................................................................................................................................... 4 Dimensions (mm) .................................................................................................................................. 5 CONFIGURATION DIAGRAM ......................................................................................... 5 SYSTEM CONFIGURATION ........................................................................................... 6 1 2 3 4 5 6 7 8 Enclosure........................................................................................................................................ 6 Installable Blades .......................................................................................................................... 6 Switch Module / Pass-Through Card ........................................................................................... 9 3.1 Network Switche and Pass-Through Card......................................................................... 10 3.2 Fibre Channel Switch and Pass-Through Card ................................................................. 12 Enclosure Management Card ..................................................................................................... 12 Power Supply Module ................................................................................................................. 13 Cooling Fan .................................................................................................................................. 13 Optical Drive ................................................................................................................................. 14 Add-on Components ................................................................................................................... 15 8.1 Front Bezel ......................................................................................................................... 15 8.2 Flash FDD .......................................................................................................................... 15 8.3 17-inch LCD Console Drawer ............................................................................................ 15 8.4 KVM Switch ........................................................................................................................ 15 8.5 SUV Cable ......................................................................................................................... 15 REFERENCES............................................................................................................... 16 Product Overview ................................................................................................................................ 16 Enclosure Management Card ........................................................................................................ 16 1Gb Intelligent L3 Switch ............................................................................................................... 18 1:10Gb Intelligent L3 Switch .......................................................................................................... 20 10Gb Intelligent L3 Switch ............................................................................................................. 22 10Gb Intelligent L3 Switch ............................................................................................................. 24 1Gb Pass-Through Card ................................................................................................................ 26 10Gb Pass-Through Card .............................................................................................................. 27 4G FC Pass-Through Card ............................................................................................................ 28 8G FC switch (12 ports) ................................................................................................................. 29 8G FC switch (24 ports) ................................................................................................................. 30 Copyright Notice and Liability Disclaimer ........................................................................................ 31 REVISION HISTORY ..................................................................................................... 32 NEC Corporation Revision 3.1 – December 8, 2015 2 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 Technical Specification Key Features High capability with sixteen server/storage blades bays and eight switch modules bays High reliability by redundant enclosure management card, power supply, and cooling fan Full manageability by enclosure management card Specification Model Part Number Number of Bays Internal Storage Blade Enclosure H v2 Blades Switch Modules Enclosure Management Card Power Supply Cooling Fan Optical Disk Drive Interfaces Server Management Redundant Server Management Controller Redundant Fan Redundant Power Supply Power Supply Maximum Power Consumption Dimensions (W x D x H ) Weight (Maximum) Temperature, Relative Humidity (non-condensing) Regulatory and Safety Standards 1 N8405-040AF 16 8 2 6 10 DVD-ROM drive Read speed: DVD 8X maximum, CD 24X maximum 1 Keyboard (6-pin mini DIN, 1 rear) 1 Mouse (6-pin mini DIN, 1 rear) 1 VGA (15-pin mini D-sub, 1 rear) 1 USB2.0 (1 rear) Enclosure Management Card Optional, hot plug Optional, hot plug Optional, hot plug 100-240 VAC ± 10% 50 / 60 Hz ± 1 Hz 12,148 VA / 11,905 Watt 483 x 823 x 442 mm (10U) / 19.0 x 32.4 x 17.4 in 214 kg, 471.78 lbs. 1 1 Operating: 10° to 40°C / 50° to 104°F , 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% FCC, CE, CCC, UL, CB, RoHS, WEEE For some configurations, it may be up to 35°C/95°F depending on the installed equipment. NEC Corporation Revision 3.1 – December 8, 2015 3 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 External Views Front View A B C D Legend A. Server/Storage Blade Bays C. Control Panel B. DVD-Drive D. USB Connector Rear View A E FG H B I C A D Legend A. B. C. D. E. Cooling Fan Bays Switch Module Bays Enclosure Management Card Bays Power Supply Bays Keyboard Connector NEC Corporation F. G. H. I. Mouse Connector Serial Connector Blade Enclosure Interconnect Connector VGA Connector Revision 3.1 – December 8, 2015 4 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 445.0 483.0 Dimensions (mm) 442.0 823.0 Configuration Diagram Optical Drive Control Panel Legend: NEC Corporation Server Blade Bay #8 Server Blade Bay #16 Server Blade Bay #7 Server Blade Bay #15 Server Blade Bay #6 Server Blade Bay #14 Server Blade Bay #5 Server Blade Bay #13 Server Blade Bay #4 Server Blade Bay #12 Server Blade Bay #3 CHASSIS REAR Server Blade Bay #11 Server Blade Bay #2 Server Blade Bay #10 Server Blade Bay #9 Server Blade Bay #1 CHASSIS FRONT Cooling Fan Cooling Fan Cooling Fan Cooling Fan Cooling Fan Switch Module Bay #1 Switch Module Bay #2 Switch Module Bay #3 Switch Module Bay #4 Switch Module Bay #5 Switch Module Bay #6 Switch Module Bay #7 Switch Module Bay #8 EM Card #1 Cooling Fan Power Supply #1 Standard Components EM Card#2 Cooling Fan Power Supply #2 Cooling Fan Power Supply #3 Cooling Fan Power Supply #4 Power Supply #5 Cooling Fan Power Supply #6 Mandatory Components Revision 3.1 – December 8, 2015 5 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 System Configuration 1 Enclosure Product Name / Description Part Number Blade Enclosure H v2 10U height enclosure N8405-040AF 2 Installable Blades Available sockets: 16 Category Product Name Part Number Server NEC Express5800/B120f-h NEC Express5800/B120f NEC Express5800/B120e NEC Express5800/B120e-h NEC Express5800/B110d NEC Express5800/B120d NEC Express5800/B120d-h NEC Express5800/B120b NEC Express5800/B120b-d NEC Express5800/B120b-h NEC Express5800/B120a NEC Express5800/B120a-d NEC Express5800/B140a-T AD106c AD106b AD106a AT101b Slot Cover(Server Blade) -N8405-046 Storage and I/O Tape Bay Cover NOTE: To configure the blades, refer to the Configuration Guide of each blade. For efficient cooling, all vacant slots must be covered with a Slot cover. Server Blade and Storage/Tape Installation Guideline See the figures below to install the blades. One-bay height server blades: Server blades can be installed into any bay. NEC Corporation Revision 3.1 – December 8, 2015 6 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 1 2 9 10 11 12 13 14 15 16 NEC Corporation 3 4 5 6 7 8 Revision 3.1 – December 8, 2015 7 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 One-bay height server blades paired with storage or tape blades: Install sets of server blades and their direct attached storage/tape blades into paired/horizontally adjacent bays as below. 1 2 3 4 5 6 7 8 Tow bay height blades: Install server blades into the bays as below. Install two-bay height server blades in pairs, or install a Slot Cover instead of the second blade in horizontally adjacent bays (1-2, 3-4, 5-6, 7-8) as below. 1 2 NEC Corporation 3 4 5 6 7 8 Revision 3.1 – December 8, 2015 8 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 3 Switch Module / Pass-Through Card Switch Modules / Pass-Through Cards and Installable Bays See the table below for installable switches or cards and bay number. The paired bays (1-2, 3-4, 5-6, 7-8) must have the same modules or cards installed. Switch Module Bays Part Number N8406-023AF N8406-044F N8406-051F N8406-052F N8406-026 N8406-029 N8406-036F N8406-040F N8406-042F N8406-030 1 Product Name : Bay # 1Gb Intelligent L3 Switch 1:10Gb Intelligent L3 Switch 10Gb Intelligent L3 Switch 10Gb Intelligent L3 Switch 10Gb Intelligent L3 Switch 1Gb Pass-Through Card 10Gb Pass-Through Card 8G FC switch (12 ports) 8G FC switch (24 ports) 4G FC Pass-Through Card #1 / #2 #3 / #4 - #5 / #6 1 #7 / #8 1 - When installing N8406-026 10Gb Intelligent L3 Switch, The same switch must be installed into switch module bays 5-6 and 7-8. Switch Module Bay Positions Bay #1 Bay #3 Bay #5 Bay #7 Bay #2 Bay #4 Bay #6 Bay #8 Network Port and Switch Module Bay Interconnection See the tables below for the network port and switch module bay interconnection. Because the blades in the enclosure share switch modules or pass-through cards, all blades must have I/O expansion cards of the same interface installed in the same bay to correspond with the switch modules. 2-Socket Server Blades and Storage/Tape Blades Blade Port Type Port Embedded NIC Expansion Slot 1 Type 1 I/O Expansion Card excluding N8403-049F Quad Port 10GbE Adapter N8403-049F Quad Port 10GbE Adapter NEC Corporation Port 1 Port 2 Port 1 Switch Module Bays Port 2 Bay #1 Bay #2 Bay #3 Bay #4 Port 1 and Port 2 Port 3 and Port 4 Bay #3 Bay #4 Revision 3.1 – December 8, 2015 9 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 Expansion Slot 2 Type 2 I/O Expansion Card excluding N8403-024 10GbE (2ch) Adapter and N8403-049F Quad Port 10GbE Adapter N8403-024 10GbE(2ch) adapter N8403-049F Quad Port 10GbE Adapter Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 1 and Port 2 Port 3 and Port 4 Bay #5 Bay #6 Bay #7 Bay #8 Bay #5 and Bay #6 Bay #6 and Bay #7 Bay #5 Bay #6 4-Socket Server Blades Blade Port Type Port Embedded NIC Expansion Slot 1 Type 1 Expansion Slot 2 Type 2 I/O Expansion Card excluding N8403-024 10GbE (2ch) adapter N8403-024 10GbE(2ch) adapter Switch Module Bays Port 1 Bay #1 Port 2 Bay #2 Port 3 Bay #1 Port 4 Bay #2 Port 1 Bay #3 Port 2 Bay #4 Port 1 Bay #5 Port 2 Bay #6 Port 3 Bay #7 Port 4 Bay #8 Port 1 Bay #5 and Bay #6 Port 2 Bay #6 and Bay #7 Expansion Slot 3 Type 1 Port 1 Bay #3 Port 2 Bay #4 Expansion Slot 4 Type 2 Port 1 Bay #7 Port 2 Bay #8 Port 3 Bay #5 Port 4 Bay #6 3.1 Network Switche and Pass-Through Card Category GbE Switch Card 10GbE NEC Corporation Switch Product Name / Description Part Number 1Gb Intelligent L3 Switch Uplink : 5 1000BASE-T (RJ-45), 4 1000BASE-SX (SPF) NOTE: - N8406-024 1000BASE-SX SFP Module is required for each port to connect an optical cable. - 4 ports of 1000BASE-SX and 4 ports of 1000BASE-T are mutually exclusive. - K410-84(05) Ethernet crossover cable is recommended to configure a switch. 1Gb Pass-Through Card Uplink : 16 1000BASE-T (RJ-45) NOTE: - The card supports only 1 Gbps link speed. N8406-023AF 10Gb Intelligent L3 Switch Uplink :8 10GBASE-SR (SFP+) Downlink:16 NOTE: - Interconnection with N8403-024 10GbE adaptor (2ch) is not N8406-051F Revision 3.1 – December 8, 2015 N8406-029 10 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 supported. - The following SFP Module is required for each port to connect a cable: N8406-024 1000BASE-SX SFP Module N8406-037 10GBASE-SR SFP+ Module N8406-039 1000BASE-T SFP Module - An Inter-link connection is supported with a backplane to connect with switches installed into horizontally adjacent bays. To connect with switches not installed into horizontally adjacent bays, K410-203(03) 10GSFP+ Cable is required. 10Gb Intelligent L3 Switch Uplink : 8 10GBASE-SR (SFP+), 2 40GBASE-SR (QSFP+) Downlink : 32 NOTE: - Interconnection with N8403-024 10GbE adaptor (2ch) is not supported. - The following SFP Module is required for each port to connect a cable when using an SFP Module slot: N8406-024 1000BASE-SX SFP Module N8406-037 10GBASE-SR SFP+ Module N8406-039 1000BASE-T SFP Module - The following QSFP Module is required for each port to connect a cable when using a QSFP Module slot: N8406-053 40GBASE-SR QSFP+ Module - An Inter-link connection is supported with a backplane to connect with switches installed into horizontally adjacent bays. To connect with switches not installed into horizontally adjacent bays, K410-203(03) 10GSFP+ Cable is required when using an SFP Module slot, and K410-235(03) 40G QSFP Cable or K410-236(03) 40G QSFP-10G SFP+ x4 Cable is required when using an QSFP Module slot. - The switch is make-to-order product. Please consult our sales representative in regard to production lead time. 1:10Gb Intelligent L3 Switch Uplink : 2 10GBASE-SR (XFP), 4 1000BASE-T (RJ-45) NOTE: - N8406-027 10GBase-SR XFP Module is required for each port to connect an optical cable. - K410-84(05) Ethernet crossover cable is recommended to configure a switch. - The interconnection speed to server blades is 1Gbps Card 10Gb Pass-Through Card Uplink :16 10GBASE-SR (SFP+) NOTE: - Interconnection with N8403-024 10GbE adaptor (2ch) is not supported. - The following SFP Module is required for each port to connect a cable: N8406-024 1000BASE-SX SFP Module N8406-037 10GBASE-SR SFP+ Module N8406-039 1000BASE-T SFP Module - The card supports only 1 Gbps and 10 Gbps link speed. - To connect to an external network, route through external switch. - To connect to a FCoE network via 10Gb Pass-though card, 10Gb Converged Network Adapter must be used. N8406-052F N8406-044F N8406-036F NOTE: For standard NIC connection, select either the 1Gb Intelligent L3 Switch, 1:10Gb Intelligent L3 Switch, 10Gb Intelligent L3 Switch, 1Gb Pass-Through Card or 10Gb Pass-Through Card. To activate both NIC ports of a server blade, a pair of a switch or card is required. NEC Corporation Revision 3.1 – December 8, 2015 11 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 3.2 Fibre Channel Switch and Pass-Through Card Category 8G Switch Product Name / Description Part Number 8G FC switch (12 ports) 8 downlink, 4 uplink, including 2 SFP+ modules NOTE: - Up to 8 blades installed into the upper blade bays can be connected to the switches. - N8406-041 4G/8G SFP+ modules must be ordered if three or more modules are needed. - The switch supports only 4 and 8 Gbps link speed. 8G FC switch (24 ports) 16 downlink, 8 uplink, including 4 SFP+ modules NOTE: - N8406-041 4G/8G SFP+ modules must be ordered if five or more modules are needed. - The switch supports only 4 and 8 Gbps link speed. N8403-040F N8406-042F NOTE: Link speed of two fibre channel ports in a controller in a blade must be the same. To activate two fibre channel ports of a dual channel fibre channel controller in a server blade, a pair of a switch or card is required. 4 Enclosure Management Card Available bays: 2 Product Name / Description Part Number Enclosure Manager Card N8405-043 NOTE: Minimum one enclosure management card must be installed. Install two cards for redundancy. The Management LAN Connector supports auto negotiation only. Attention is required when configuring settings to the external switch connected to this connector. Supporting Virtual IO control See the tables below for the blades and optional NICs that support the feature. Category Part Number Server Blades B120f , B120f-h 1 1 B120e , B120e-h 1 1 1 B120d , B110d , B120d-h 2 B120b, B120b-d, B120b-h 1 1 B120a, B120a-d Storage and Tape Blades AD106c, AD106b, AD106a, AT101b Optional NICs N8403-018 N8403-034 N8403-021 N8403-022 N8403-035 N8403-065F N8403-067F N8403-084F N8403-085F NEC Corporation Fibre Channel Controller(4Gbps/2ch) Fibre Channel Controller(8Gbps/2ch) 3 1000BASE-T(2ch) adapter (for iSCSI) 3 1000BASE-T(4ch) adapter (for iSCSI) 10GBASE-KR LAN interface card Dual Port 10GBASE Adapter Dual Port 10GBASE Adapter(for iSCSI) Dual Port 10GBASE Adapter Dual Port 10GBASE Adapter Revision 3.1 – December 8, 2015 12 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 N8403-049F Quad Port 10GBASE Adapter N8403-051F Quad Port 10GBASE Adapter 1 Supports only on the flexible integrated NICs. 2 Not support in PXE Boot configuration 3 Not support on the following operating systems: Red Hat Enterprise Linux : 5.6, 5.7, 6.0, 6.1 VMWare ESX/ESXi : 4.0 Update3 or later, 4.1 Update1, 4.1 Update2, 5.0 5 Power Supply Module Available bays: 6 Product Name / Description Part Number Power Unit 2,269 Watt (200VAC), 985 Watt (100VAC) N8405-044F NOTE: Minimum two power units for 200VAC input and minimum three power units for 100VAC input must be installed. Number of Required Power Supplies See the table below for the number of power supplies required according to maximum power consumption. Maximum power consumption can be calculated by adding the power consumption of each server/storage blade, the power consumption of each switch modules/pass-through cards and the power consumption of blade enclosure, 725 Watts 200VAC Input Maximum Power Consumption (VDC / Watt) Number of Power Supplies (N+1) Number of Power Supplies (N+N) Up to 2244 Up to 4260 Up to 6280 Up to 8304 Up to 10320 2 3 4 5 6 2 4 6 Not Available Not Available Remarks 100VAC Input Maximum Power Consumption (VDC / Watt) Number of Power Supplies (N+1) Number of Power Supplies (N+N) Up to 1824 Up to 2688 Up to 3552 Up to 4416 3 4 5 6 4 6 Not Available Not Available Remarks 6 Cooling Fan Available bays: 10 Product Name / Description Part Number Fan Unit N8405-045F NOTE: NEC Corporation Revision 3.1 – December 8, 2015 13 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 Minimum four or six fan units must be installed as indicated below. Number of Required Fan Units See the figure below for the number of fan units required according to type of blades and the number of blades installed. Server/Storage Blades excluding B120b-h, B120d, B110d, B120d-h, B120e, B120e-h, B120f, B120f-h To install blade servers in area #1 only, four fan units are required. To install blade servers in area #1 and #2, six fan units are required. To install blade servers in area #1, #2 and #3, eight fan units are required. 4 fans 6 fans 1 2 8 fans 3 B120b-h, B120d, B110d, B120d-h, B120e, B120e-h, B120f, B120f-h To install blade servers in area #1 only, six fan units are required. To install blade servers in area #1 and #2, eight fan units are required. To install blade servers in area #1, #2 and #3, ten fan units are required. 6 fans 8 fans 1 2 10 fans 3 7 Optical Drive Product Name / Description Part Number Internal Slim DVD-ROM drive Slim DVD-ROM drive (Standard) NEC Corporation Revision 3.1 – December 8, 2015 14 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 8 Add-on Components 8.1 Front Bezel Product Name / Description Part Number Front Bezel NOTE: When installing the enclosure into a rack cabinet, be sure the rack has enough depth. The enclosure with the front bezel may be too large for the rack door to close. In such cases, use racks without doors N8405-051 8.2 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-96 8.3 17-inch LCD Console Drawer Category Drawer Drawer w/o KVM 8.4 Product Name / Description Part Number 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2 m N8143-76F KVM Switch Category Product Name / Description Part Number KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch N8191-12F Switch Unit Connection Cable Set (PS/2,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 2 x PS/2 Switch Unit Connection Cable Set (PS/2,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 2 x PS/2 Switch Unit Connection Cable Set (PS/2,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 2 x PS/2 Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 K410-119(1A) Cable KVM Cascading 8.5 K410-119(03) K410-119(05) K410-119(1A) SUV Cable Product Name / Description Part Number SUV Cable 0.6 m, 1 x SUV to 1 x 15-pin mini D-sub, 1 x USB, 1 x 9-pin D-sub NOTE: One cable is included in the blade enclosure. K410-150(00) NEC Corporation Revision 3.1 – December 8, 2015 15 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 References Product Overview Enclosure Management Card The enclosure management card provides the following management feature: Web console integration The enclosure management card web console displays a list of the Blade Enclosure H v2 / -M enclosures that are installed in the same rack cabinet. Via the list, the web consoles of other enclosures are available to view. Power capping management For power consumption control, a maximum power consumption value can be set through the enclosure management card for each enclosure or for the whole blade enclosure group in the same rack. vIO Control The Virtual IO control feature virtualizes the MAC address / WWN / UUID / serial number of server blades. Specification Model Enclosure Management Card Part Number Features N8405-043 Interface 1 Serial (9-pin D-sub) 2 (1) 100BASE-T (RJ-45) 0.3 kg, 0.66 lbs. 5.5 Watt Power supply management Cooling management Enclosure management System status monitoring Redundancy Switch module configuration Web console integration Power capping management Enclosure web console management 1 vIO control Weight (Maximum) Maximum Power Consumption (VDC) 1 Requires EMFW 05.00 or later 2 Supports only automatic negotiation NEC Corporation Revision 3.1 – December 8, 2015 16 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 Front View A B C D E F G H I Legend A. B. C. D. E. Reset Button System Status LED Active LED ID LED ID Button NEC Corporation F. G. H. I. Serial Port Connector LAN Connector Link/active LED Speed LED Revision 3.1 – December 8, 2015 17 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 1Gb Intelligent L3 Switch Specification Model Part Number Performance Interface 1Gb Intelligent L3 Switch Switching capacity MAC address Forwarding method Forwarding rate Downlink Inter-switch 1 Uplink Other Features Specifications Management Interface Supported NIB Weight (Maximum) Card Size Maximum Power Consumption (VDC) 1 N8406-023AF 48 Gbps up to 8K address (per module) Store and Forward 1,488,095 pps per port (16) 1000BASE-X (2) 1000BASE-X (5) 1000BASE-T (RJ-45), (4) 1000BASE-SX (SFP) 1 Serial Layer 2 Switch function Layer 3 Switch function VLAN (Port/Tag/Private) Spanning tree (STP, RSTP, MSTP, PVRST) Link aggregation (static, LACP) Trunk failover (original) QoS ACL (Access Control List) Jumbo frame (up to 9K) Port mirroring Auto MDI / MDI-X IGMP snooping (v1, v2, v3) NTP client DNS client Syslog 802.1x RADIUS TACACS+ SNMP v1, v2c, v3 RMON (Group 1, 2, 3, 9) Routing protocol (static, RIPv1, RIPv2, OSPF) VRRP IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3ac, IEEE802.3ad, IEEE802. 1D, IEEE802.1W, IEEE802.1s, IEEE802.1Q Web Console, telnet/ssh, serial console SNMPv1 (RFC 1157) MIB-II (RFC 1213) Bridge-MIB (RFC 1493) Interface MIB (RFC 2863) Ethernet MIB (RFC 1643) RMON v1 (RFC 1757) Group 1, 2, 3, 9 2 kg, 4.41 lbs. 1 bay width 30 Watt 4 ports of 1000BASE-SX and 4 ports of 1000BASE-T are mutually exclusive. NEC Corporation Revision 3.1 – December 8, 2015 18 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 Front View A B E C F D C G F G H Legend A. B. C. D. ID LED Serial Connector RJ-45 Connectors SFP Connectors NEC Corporation E. F. G. H. Status LED Link/active LED Speed LED Reset Button Revision 3.1 – December 8, 2015 19 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 1:10Gb Intelligent L3 Switch Specification Model Part Number Performance Interface 1:10Gb Intelligent L3 Switch Switching Capacity MAC Address Forwarding Method Forwarding Rate Downlink Inter-switch Uplink Other Features Specifications Management Interface Supported NIB Weight (Maximum) Card Size Maximum Power Consumption (VDC) NEC Corporation N8406-044F 122 Gbps up to 8K address per module Store and Forward 1Gbps port : 1,488,095 pps per port 10Gbps port : 14,880,950 pps per port (16) 1000BASE-X (1) 10GBASE-X (2) 10GBASE-SR (XFP), (4) 1000BASE-T (RJ-45) 1 Serial Layer 2 Switch function Layer 3 Switch function VLAN (Port/Tag/Protocol/Private) Spanning tree (STP, RSTP, MSTP, PVRST) Link aggregation (static, LACP) Trunk failover (original) QoS ACL (Access Control List) Jumbo frame (up to 9K) Port mirroring Auto MDI / MDI-X IGMP snooping (v1, v2, v3) NTP client DNS client Syslog 802.1x RADIUS TACACS+ SNMP v1, v2c, v3 RMON (group 1, 2, 3, 9) Routing protocol (static, RIPv1, RIPv2, OSPF) VRRP IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3ac, IEEE802.3ad, IEEE802.1D, IEEE802.1w, IEEE802.1s, IEEE802.1Q Web Console, telnet/ssh, serial console SNMPv1 (RFC 1157) MIB-II (RFC 1213) Bridge-MIB (RFC 1493) Interface MIB (RFC 2863) Ethernet MIB (RFC 1643) RMON v1 (RFC 1757) Group 1, 2, 3, 9 2 kg, 4.41 lbs. 1 bay width 50 Watt Revision 3.1 – December 8, 2015 20 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 Front View A B C C D E D N8406-044 19 F 22 23 24 25 RST 21 20 G G H I J Legend A. B. C. D. E. ID LED Serial Connector Link LED XFP Connectors RJ-45 Connectors NEC Corporation F. G. H. I. J. Status LED Active LED Link/active LED Speed LED Reset Button Revision 3.1 – December 8, 2015 21 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 10Gb Intelligent L3 Switch Specification Model Part Number Performance Interface 10Gb Intelligent L3 Switch Switching Capacity MAC Address Forwarding Rate Downlink Inter-switch Uplink Other Features Management Interface Supported NIB Weight (Maximum) Card Size Maximum Power Consumption (VDC) 1 N8406-051F 480 Gbps up to 128 K address per module 14.8 Mpps per port (16) 10GBASE-X 1 (4) 10GBASE-X 1 (8) 10GBASE-SR (SFP+) 1 Serial Layer 2 Switch function Layer 3 Switch function VLAN (Port/Tag/Protocol/Private) Spanning tree (RSTP, MSTP, PVRST) Link aggregation (static, LACP) Trunk failover (original) QoS ACL (Access Control List) Jumbo frame (up to 9K) Port mirroring Auto MDI / MDI-X IGMP snooping (v1, v2, v3) NTP client DNS client Syslog 802.1x RADIUS TACACS+ SNMP v1, v2c, v3 RMON (group 1, 2, 3, 9) Routing protocol (static, RIPv1, RIPv2, OSPF) VRRP Web Console, telnet/ssh, serial console SNMPv1 (RFC 1157) MIB-II (RFC 1213) Bridge-MIB (RFC 1493) Interface MIB (RFC 2863) Ethernet MIB (RFC 1643) RMON v1 (RFC 1757) Group 1,2,3,9 2 kg, 4.41 lbs. 1 bay width 100 Watt 4 ports of 10GBASE-X and 4 ports of 10GBASE-SR are mutually exclusive. NEC Corporation Revision 3.1 – December 8, 2015 22 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 Front View A B C D E N8406-051 -38- -39- -40- -41- -42- -43- -44- -45RST 46-49 F 50-53 G Legend A. B. C. D. ID LED Serial Connector Link LED Active LED NEC Corporation E. F. G. SFP+ Connectors Status LED Reset Button Revision 3.1 – December 8, 2015 23 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 10Gb Intelligent L3 Switch Specification Model Part Number Performance Interface 10Gb Intelligent L3 Switch Switching Capacity MAC Address Forwarding Rate Downlink Inter-switch Uplink Other Features Management Interface Supported NIB Weight (Maximum) Card Size Maximum Power Consumption (VDC) NEC Corporation N8406-052F 1040 Gbps up to 128 K address per module 14.8 Mpps per port (32) 10GBASE-X 1 (4) 10GBASE-X (8) 10GBASE-SR (SFP+), (2) 40GBASE-SR (QSFP+) 1 Serial Layer 2 Switch function Layer 3 Switch function VLAN (Port/Tag/Protocol/Private) Spanning tree (RSTP, MSTP, PVRST) Link aggregation (static, LACP) Trunk failover (original) QoS ACL (Access Control List) Jumbo frame (up to 9K) Port mirroring Auto MDI / MDI-X IGMP snooping (v1, v2, v3) NTP client DNS client Syslog 802.1x RADIUS TACACS+ SNMP v1, v2c, v3 RMON (group 1, 2, 3, 9) Routing protocol (static, RIPv1, RIPv2, OSPF) VRRP Web Console, telnet/ssh, serial console SNMPv1 (RFC 1157) MIB-II (RFC 1213) Bridge-MIB (RFC 1493) Interface MIB (RFC 2863) Ethernet MIB (RFC 1643) RMON v1 (RFC 1757) Group 1,2,3,9 2 kg, 4.41 lbs. 1 bay width 100 Watt Revision 3.1 – December 8, 2015 24 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 Front View A B C D E F N8406-052 -38- -39- -40- -41- -42- -43- -44- -45RST 46-49 H 50-53 G I Legend A. B. C. D. E. ID LED Serial Connector Link LED Active LED SFP+ Connectors NEC Corporation F. G. H. I. QSFP+ Connectors Link/Active LED Status LED Reset Button Revision 3.1 – December 8, 2015 25 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 1Gb Pass-Through Card Specification Model 1Gb Pass-Through Card Part Number Interface N8406-029 (16) 1000BASE-X Uplink (16) 1000BASE-T (RJ-45) 2 kg, 4.41 lbs. 1 bay width 14 Watt Weight (Maximum) Card Size Maximum Power Consumption (VDC) 1 1 Downlink 1 Not support 10BASE-T and 100BASE-TX connection. Front View A D E F B C B C A Legend A. B. C. RJ-45 Connectors Link/active LED Speed LED NEC Corporation D. E. F. Reset Button ID LED Status LED Revision 3.1 – December 8, 2015 26 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 10Gb Pass-Through Card Specification Model 10Gb Pass-Through Card Part Number Interface N8406-036F Downlink (16) 10GBASE-X Uplink Weight (Maximum) Card Size Maximum Power Consumption (VDC) (16) 10GBASE-SR (SFP+) 2 kg, 4.41 lbs. 1 bay width 76 Watt Front View AB C D E Legend A. B. C. ID LED Status LED Port Status LED NEC Corporation D. E. Reset Button SFP+ Connectors Revision 3.1 – December 8, 2015 27 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 4G FC Pass-Through Card Specification Model 4G FC Pass-Through Card Part Number Interface N8406-030 Downlink 16 Uplink Supported Link Speed (Gbps) 16 SFP Weight (Maximum) Card Size Maximum Power Consumption (VDC) 2 kg, 4.41 lbs. 1 bay width 39 Watt 2/4 Front View A B B C D A E Legend A. B. C. SFP Connectors Link LED ID LED NEC Corporation D. E. Reset Button Status LED Revision 3.1 – December 8, 2015 28 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 8G FC switch (12 ports) Specification Model 8G FC switch (12 ports) Part Number Interface N8406-040F 8 4 x SFP 4/8 High Speed switching function Auto routing function Cascade connection Zoning function Shared Memory F / FL / E port support 2 kg, 4.41 lbs. 1 bay width 38 Watt Downlink Uplink Supported Link Speed (Gbps) Feature Internal Architecture Weight (Maximum) Card Size Maximum Power Consumption (VDC) Front View A E B C D F Legend A. B. C. ID LED Status LED Port Status LED NEC Corporation D. E. F. SFP Connectors Reset Button Active LED Revision 3.1 – December 8, 2015 29 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 8G FC switch (24 ports) Specification Model 8G FC switch (24 ports) Part Number Interface N8406-042F 16 8 x SFP 4/8 High Speed switching function Auto routing function Cascade connection Zoning function Shared Memory F / FL / E port support 2 kg, 4.41 lbs. 1 bay width 38 Watt Downlink Uplink Supported Link Speed (Gbps) Feature Internal Architecture Weight (Maximum) Card Size Maximum Power Consumption (VDC) Front View A E B C D D F Legend A. B. C. ID LED System Status LED Port Status LED NEC Corporation D. E. F. SFP Connectors Reset Button Active LED Revision 3.1 – December 8, 2015 30 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. NEC Corporation Revision 3.1 – December 8, 2015 31 SYSTEM CONFIGURATION GUIDE – NEC Blade Enclosure H v2 Revision History Revision Date Description 3.1 December 8, 2015 Others: Added a note to the specification table Deleted BSMI from Regulatory and Safety Standards because not applicable 3.0 June 19, 2015 New products added: Flash FDD / N8160-96 Others: Added support information of B120f-h, N8403-051, and N8403-085 2.0 October 16, 2014 New products added: 10Gb Intelligent L3 Switch / N8406-052F Others: Add support information of new server blade Remove Flash FDD 1.3 January 16, 2014 Others: Add support information of new server blade 1.2 September 13, 2013 Others: Add support information of new server blade and storage blade 1.1 August 6, 2013 Others: Correct incorrect parts number and product name for KVM switch cables 1.0 September 28, 2012 Initial release in new format NEC Corporation Revision 3.1 – December 8, 2015 32