JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 75SA-030 SWITCH ASSEMBLY Frequency Range 5-1000 MHz Configuration 10 individually controlled 1P4T reflective solid-state RF switches Enclosure Type 19 inch rack mount @ 4RU high Startup/Default States (configurable) RF switches off at startup (see SWITCH command) DHCP enabled (see NET command) 4 Ethernet users (see NET command) Prompts off (see PROMPT command) Impedance 75 Ohms nominal VSWR 1.3:1 maximum Insertion Loss 2.5 dB maximum Isolation 60 dB minimum RF Input Power +20 dBm (1 dB compression) +30 dBm (no damage) Switching Speed 10 microseconds (after command is received and processed) (3 milliseconds typical processing time) Manual Control 20-Button Keypad and LCD display (IP Address configurable via keypad) (Net mask configurable via keypad) (Gateway configurable via keypad) (Baud rate configurable via keypad) Remote Control Ethernet (DHCP, TCP/IP, 10/100, up to 12 users) RS-232 (up to 115200 Baud) Remote Commands RF Switch Control Commands: Switch, Set Switch, Read Switch, Set All Switches, Read All Switches System Commands: Help, Identification, Store, Recall, Pause, Net, Serial, Close, Disconnect, MOTD, Date, Message, Restrict, IDENT, Name, Show Users, Reboot, Uptime, Prompt RF Connector F female --CONTINUED-Page 1 of 2 JFW FORM E-7-F REV F JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 75SA-030 SWITCH ASSEMBLY AC Supply 100-240 VAC @ 47-63 Hz 2 Amp 5x20mm "Slo-Blo" AC fuse Littelfuse #215-002, JFW #025-021 Operating Temperature Range 0ºC to +50ºC Physical Size See outline drawing 092-4915 ECR/ECN # DATE REV 08/22/2005 Page 2 of 2 APPR / DATE ECR/ECN # DATE REV APPR / DATE SL 08/22/2005 16179 08/07/2008 C TRS 08/07/2008 11839 09/07/2005 A SL 09/07/2005 20002 04/20/2011 D TRS 04/20/2011 15916 05/28/2008 B TRS 05/28/2008 24239 12/09/2014 E TRS 12/09/2014 JFW FORM E-7-F REV F