6075988029en

Technical Data
Safety switch
Series CSMS
Type designation CSMS-SET-RRS-U-KA
Set consisting of
Article number
6075985025
6075980023
6075980023
Type designation
CSMS-M-RRS-U-KA
CSMS-S
Article number
6075988029
Description
CSMS, cable version with plug connector
Actuator
6075985025
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 19.06.2012 / Page 1 of 4
Document : 6075988029_en.doc / Last update : 2 / 0221-12
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu
Vorlage : 0850174285 Orig. 1
Technical Data
Safety switch
Sensing distance
min.
Rated sensing distance
Assured sensing distance – On
Hysteresis
Assured sensing distance – Off
Sn
Sao
H
Sar
typ.
13 mm
max.
10 mm
0,5 mm
19 mm
Distance S [mm]
14
Off
Switch-off distance
12
10
Hysteresis
Switch-on distance
8
On
6
4
2
0
-35
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
Side lobe
Metal can influence the sensing distance.
Active surfaces
Connection
Pin 1 – DI - white
Pin 2 – I1 - brown
Pin 3 – I2 / Q3 - green
Pin 4 – DO - yellow
Pin 5 – Q1 - grey
Pin 6 – Q2 - pink
Pin 7 – + - blue
Pin 8 – - - red
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 19.06.2012 / Page 2 of 4
Document : 6075988029_en.doc / Last update : 2 / 0221-12
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu
Vorlage : 0850174285 Orig. 1
Technical Data
Safety switch
Electrical Data
Rated operating voltage
Ue
Voltage level
Rated insulation voltage
Ui
Rated impulse withstand voltage
Uimp
Rated conditional short circuit current
No-load current
I0
Transponder frequency
Repeatability
Operating frequency
Switch-off
ta
Time delay start button
tv
Automatic start on delay
tv
Electromagnetic interference
Inputs I1,I2, Di (digital inputs according to EN61131-2)
Voltage
UHmax
UHmin
ULmin
ULmax
Outputs Q1,Q2
Switching element funtion
Rated operating current
Ie
Minimum operating current
Im
Leakage current
Ir
Switching elements
Voltage drop
Ud
Type of short circuit protection
Utilization category
Output Do
Switching element funtion
Rated operating current
Ie
Minimum operating current
Im
Leakage current
Ir
Switching elements
Voltage drop
Ud
Type of short circuit protection
Utilization category
Mechanical Data
Enclosure
Mounting
Indication
Shock and Swing
Ambient temperature
Storage temperature
Maximum relative humidity
Altitude
Connection
Mass 6075985025
6075980023
Type of protection
Protection class acc. to EN IEC 61558
Pollution degree
24 V, Reverse polarity protection
according to Typ 3 EN 61131-2
75 V DC
500 V
100 A
≤ 55 mA
6,78 MHz
0,1 x S (within the limits Smin and Smax)
≤ 1Hz
5 ms + 260 µs x following CSMS
33 ms +33 ms x following CSMS
2 s +33 ms x following CSMS
according to EN IEC 60947-5-2 and EN 61326-3-1
30 V
11 V
-3 V
5V
pnp NO
250 mA
1 mA DC
0,5 mA DC
Sustained short-circuit and overload protection
≤1V
Clocking
DC-13
npn NO
2 mA
1 mA DC
0,5 mA DC
Sustained short-circuit and overload protection
≤3V
thermal, current limited
DC-12
Macromelt, red / PA 6, black
2 holes Ø 4,5
(for M4 screws)
3 LEDs (for diagnosis)
acc. to EN IEC 60947-5-2
-25°C … +70°C
-25°C … +70°C
90 % @ 40 °C without condensation
≤ 2000 m NHN
Cable with plug connector M12 male
185g
27g
IP67
III
3 (metallic pollution can cause
impairments of the operating distances.)
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 19.06.2012 / Page 3 of 4
Document : 6075988029_en.doc / Last update : 2 / 0221-12
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu
Vorlage : 0850174285 Orig. 1
Technical Data
Safety switch
Safety data (according to EN ISO 13849-1)
Up to PL
Category
Service life
MTTFd
SIL
e
4
20 years
High
3 (according to EN 62061:2005)
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EN 50295, EN ISO 13849-1 (IEC/EN 61508,
EN 60947-5-3)
EN 300330-2
EU-Conformity
according to Directive 2006/42/EG
according to Directive 2004/108/EG
according to Directive 1999/5/EG
Approvals
TÜV Nord (being prepared)
Notes
The specified protection classification (IP code) applies only when an appropriate plug connector is used.
Intended use
Application with feedback loop with or without start button (for Stand Alone Applications)
Application with start button
Application without start button (automatic start)
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 19.06.2012 / Page 4 of 4
Document : 6075988029_en.doc / Last update : 2 / 0221-12
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu
Vorlage : 0850174285 Orig. 1