Technical Data Safety switch Series SK - ASI – with separate actuator Description Article number ASI SK M 6073205028 Operating symbol Operating diagram Actuator withdrawn inserted Tolerances Operating point: ± 0,25 mm ON OFF Electrical data Operating voltage Operating current AS-i Specifications AS-i Inputs Parameter bits AS-i Address U I 26,5 … 31,6 V; via AS-interface, reverse-polarity proof < 30mA Profile S-0.B IO-Code: 0x0 ID-Code: 0xB ID-Code1: 0xF ID-Code2: 0xE Contact 1: Date bits D0/D1 = static 00 or dynamic code transmission Contact 2: Date bits D2/D3 = static 00 or dynamic code transmission no function preset address: 0 This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice! Date of issue: 07.09.2009 / Page 1 of 2 Document : 6073205028_en / Last update: 2 / 2433-09 Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu Vorlage : 0850174285 Orig. 2 Technical Data Safety switch Mechanical data Enclosure Cover Indication Actuator Extraction force Ambient air temperature Contact type Mechanical life Switching frequency Assembly Safety switch Actuator Connection Plug connection Weight Installation position Protection type Thermoplastic, glass fibre reinforced (UL94-V0) Thermoplastic, glass fibre reinforced (UL94-V0) LEDs for slave and bus state Separate actuator (St-stainless steel) 10N -25° C … +70° C 2 NC (slow-action, Zb) 1 x 106 switch operations ≤ 30 / min. 2 x M5 2 x M5 Plug connector M12 male 1: AS-i + 2: free 3: AS-i 4: free ≈ 0,14 kg Operator definable IP65 acc. to IEC/EN 60529 Actuation Turning the cap (pos A/B) allows 4 different directions of drive. Cover (1) has to be opened before turning the cap (2). Insert the screwdriver into the gap between housing and cap and turn until the cap snaps off. Remove the cap, turn it 180° (4), latch it into the housing and close the cover. Standards VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 EN 50295, EN ISO 13849-1 EU Conformity acc. to EMC Directive Safety Classification according 13849-1 to PL e MTTFd = high PFD = 2,49 * 10-10 Notes The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent connector. The switch may not be used as a mechanical stop. Radial actuation may reduce the mechanical life. The min. radius refers to a pivot at the top of the cap (S0). Tapped holes not in use must be closed with blind plugs. This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice! Date of issue: 07.09.2009 / Page 2 of 2 Document : 6073205028_en / Last update: 2 / 2433-09 Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu Vorlage : 0850174285 Orig. 2