6075980023en 001

Technical Data
Safety switch
Series CSMS
Type designation CSMS-S
Article number
6075980023
Active surfaces
Sensing distance (Only in conjunction with CSMS of the Bernstein AG – see page 2 „Use“.)
min.
typ.
Rated sensing distance
Sn
13 mm
Assured sensing distance – On
Sao
10 mm
Hysteresis
H
0,5 mm
Assured sensing distance – Off
Sar
max.
19 mm
Distance S [mm]
14
Off
Switch-off distance
12
10
Hysteresis
Switch-on distance
8
On
6
4
2
0
-35
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
Side lobe
Metal can influence the sensing distance.
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 19.06.2012 / Page 1 of 2
Document : 6075980023_en.doc / Last update : 2 / 0221-12
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu
Vorlage : 0850174285 Orig. 1
Technical Data
Safety switch
Electrical Data
Transponder frequency
Repeatability
Operating frequency
Electromagnetic interference
Mechanical Data
Enclosure
Mounting
Shock and Swing
Ambient temperature
Storage temperature
Maximum relative humidity
Altitude
Mass
Type of protection
Protection class acc. to EN IEC 61558
Pollution degree
Safety data (according to EN ISO 13849-1)
Up to PL
Category
Service life
MTTFd
SIL
6,78 MHz
0,1 x S (within the limits Smin and Smax)
≤ 1Hz
according to EN IEC 60947-5-2 and EN 61326-3-1
Macromelt, red / PA 6, black
2 holes Ø 4,5
(for M4 screws)
acc. to EN IEC 60947-5-2
-25°C … +70°C
-25°C … +70°C
90 % @ 40 °C without condensation
≤ 2000 m NHN
27 g
IP67
III
3 (metallic pollution can cause
impairments of the operating distances.)
e
4
20 years
High
3 (according to EN 62061:2005)
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EN 50295, EN ISO 13849-1 (IEC/EN 61508,
EN 60947-5-3)
EN 300330-2
EU-Conformity
according to Directive 2006/42/EG
according to Directive 2004/108/EG
according to Directive 1999/5/EG
Approvals
TÜV Nord (being prepared)
Use
Article number
6075985025
6075986022
6075985026
6075986024
Type designation
CSMS-M-RRS-U-KA
CSMS-M-RRS-U-ST
CSMS-M-R-U-KA
CSMS-M-R-U-ST
Description - CSMS, can be switched in series,
with return circuit and start button monitoring, cable version
with return circuit and start button monitoring, M12 connector
be connected to a safety monitoring device, cable version
be connected to a safety monitoring device, M12 connector
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 19.06.2012 / Page 2 of 2
Document : 6075980023_en.doc / Last update : 2 / 0221-12
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu
Vorlage : 0850174285 Orig. 1