6073200007en

Technical Data
Rope pull switch
Series SRM - ASI
Description
Article number
ASI SRM-QF-175
6073200007
Operating symbol
Operating diagram
Latch
Latch
ON
OFF
Tolerance:
Operating point ± 0,5 mm
Actuating force ± 15 %
Electrical data
Operating voltage
Operating current
AS-i Specifications
AS-i Inputs
Parameter bits
AS-i Address
U
I
26,5 … 31,6 V; via AS-interface, reverse-polarity proof
< 30mA
Profile S-0.B
IO-Code: 0x0
ID-Code: 0xB
ID-Code1: 0xF
ID-Code2: 0xE
Contact 1: Date bits D0/D1 = static 00
or dynamic code transmission
Contact 2: Date bits D2/D3 = static 00
or dynamic code transmission
no function
preset address: 0
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 07.09.2009 / Page 1 of 2
Document: 6073200007_en / Last update: 2 / 2433-09
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein.eu
Vorlage : 0850174284 Orig. 2
Technical Data
Rope pull switch
Mechanical data
Enclosure
Cover
Indication
Actuator
Emergency Stop
Ambient air temperature
Contact type
Latching device
Reset facility
Mechanical life
Rope length
Rope ∅
Switching frequency
Assembly
Connection
Plug connection
Weight
Installation position
Protection type
Al-die cast
Al-die cast
LEDs for slave and bus state
Quick clamping device
with integrated Turnbuckle (Zn-die cast)
PA, glass fibre reinforced
-25° C ... +70° C
(no freezing over/ no condensation)
2 NC (slow-action, Zb)
acc. to IEC 60947-5-5, DIN EN 60947-5-5,
ISO 13850 (DIN EN 418)
pull of the emergency stop acc. to IEC/EN 60947-5-5
acc. to IEC 60947-5-5 max. 1 x 105 switching cycles
≤ 37,5 m
(depends on the max. temperature variation)
D = ∅ 2 - 5 mm
≤ 20/min.
4 х М6 oder 4 x M5
Plug connector M12 male
1: AS-i +
2: free
3: AS-i 4: free
≈ 0,48 kg
operator definable
IP67 acc. to IEC/EN 60529
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
VDE 0660 T210, DIN EN 60947-5-5, IEC 60947-5-5
ISO 13850
EN 50295, EN ISO 13849-1
EU Conformity
acc. to EMC Directive
Safety Classification
according 13849-1 to PL e
MTTFd = high
PFD
= 2,49 * 10-10
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an
equivalent cable gland with adequate cable.
Maintenance-free installation.
Rope with accessories is available on demand.
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 07.09.2009 / Page 2 of 2
Document: 6073200007_en / Last update: 2 / 2433-09
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein.eu
Vorlage : 0850174284 Orig. 2