REVISIONS LTR DATE (YR-MO-DA) APPROVED A Make change to case outline Y terminal symbols as specified in figure 2. - ro DESCRIPTION 00-11-07 R. MONNIN B Make change to power dissipation as specified under 1.3. - ro 01-04-20 R. MONNIN C Delete input voltage and power dissipation limits and replace with reverse current and forward current limits as specified under 1.3. - ro 04-03-12 R. MONNIN D Make change to the post irradiation limits as specified in the reference voltage test under Table I. - ro 04-05-25 R. MONNIN E Add a new footnote under paragraph 1.5 and Table I. Add pin numbers to figure 1 and add a note to figure 2. - ro 05-05-17 R. MONNIN F Add a new footnote to the conditions column header under Table I. Delete paragraph 4.4.4.1.1 accelerated aging test. Make change to paragraph A.4.3.1. - ro 06-01-18 R. MONNIN G Add two sentences to footnote 3/ as specified under Table I. - ro 08-11-05 R. HEBER H Make a clarification to paragraph 3.5 by adding back special part marking information. - ro 09-04-01 J. RODENBECK J Make correction to the zener voltage versus zener current test conditions column by deleting “100 mA” and substituting “10 mA”. - ro 10-04-20 C. SAFFLE K Make corrections to die thickness and glassivation as specified under figure A-1. - ro 11-07-06 C. SAFFLE L Add device type 02 and figure A-2. Make changes to footnotes 2/, 3/ and add 4/ under paragraph 1.5. Make changes to footnotes 1/ and 2/ under table I. Delete paragraph 4.4.4.2 Dose rate burnout. Delete figure 3 Radiation exposure circuit. Delete device class M references. - ro 13-09-10 C. SAFFLE REV SHEET REV L L L SHEET 15 16 17 REV STATUS REV L L L L L L L L L L L L L L OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PMIC N/A PREPARED BY RICK OFFICER STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http://www.landandmaritime.dla.mil CHECKED BY RAJESH PITHADIA APPROVED BY THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE AMSC N/A RAYMOND MONNIN DRAWING APPROVAL DATE 00-08-04 REVISION LEVEL L MICROCIRCUIT, LINEAR, RADIATION HARDENED, 2.5 V SHUNT DIODE REGULATOR, MONOLITHIC SILICON SIZE CAGE CODE A 67268 SHEET DSCC FORM 2233 APR 97 5962-00523 1 OF 17 5962-E489-13 1. SCOPE 1.1 Scope. This drawing documents two product assurance class levels consisting of high reliability (device class Q) and space application (device class V). A choice of case outlines and lead finishes are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of Radiation Hardness Assurance (RHA) levels is reflected in the PIN. 1.2 PIN. The PIN is as shown in the following example: 5962 F 00523 Federal stock class designator \ RHA designator (see 1.2.1) 01 V X C Device type (see 1.2.2) Device class designator (see 1.2.3) Case outline (see 1.2.4) Lead finish (see 1.2.5) / \/ Drawing number 1.2.1 RHA designator. Device classes Q and V RHA marked devices meet the MIL-PRF-38535 specified RHA levels and are marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type 01 02 Generic number Circuit function IS-1009RH IS-1009EH Radiation hardened, 2.5 V shunt regulator diode Radiation hardened, 2.5 V shunt regulator diode 1.2.3 Device class designator. The device class designator is a single letter identifying the product assurance level as follows: Device class Device requirements documentation Q or V Certification and qualification to MIL-PRF-38535 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter X Y Descriptive designator Terminals See figure 1 CBCC1-N3 3 3 Package style Can, similar to TO-206AB or TO-46 Bottom terminal chip carrier 1.2.5 Lead finish. The lead finish is as specified in MIL-PRF-38535 for device classes Q and V. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 2 1.3 Absolute maximum ratings. 1/ Reverse current ............................................................................................................ Forward current ............................................................................................................. Lead temperature (soldering, 10 seconds) .................................................................... Junction temperature (TJ) ............................................................................................. Storage temperature range ........................................................................................... Thermal resistance, junction-to-case (θJC): Case X ....................................................................................................................... Case Y ....................................................................................................................... Thermal resistance, junction-to-ambient (θJA): Case X ....................................................................................................................... Case Y ....................................................................................................................... 20 mA 10 mA 265°C 175°C -65°C to +150°C 30°C/W 8°C/W 300°C/W 60°C/W 1.4 Recommended operating conditions. Input current (IIN) .......................................................................................................... 400 µA to 10 mA Ambient operating temperature range (TA) ................................................................... -55°C to +125°C 1.5 Radiation features. Maximum total dose available (dose rate = 50 – 300 rads(Si)/s): Device type 01: .......................................................................................................... Device type 02 ........................................................................................................... Maximum total dose available (dose rate ≤ 0.01 rad(Si)/s): Device type 02 .......................................................................................................... Single event latch-up (SEL) .......................................................................................... 300 krads(Si) 2/ 300 krads(Si) 3/ 50 krads(Si) 3/ No latch up 4/ ______ 1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ Device type 01 may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effects. The radiation end point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, method 1019, condition A to a maximum total dose of 300 krads(Si). 3/ Device type 02 radiation end point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, method 1019, condition A to a maximum total dose of 300 krads(Si), and condition D to a maximum total dose of 50 krads(Si). 4/ Devices use dielectrically isolated (DI) technology and latch up is physically not possible. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 3 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 MIL-STD-1835 - Test Method Standard Microcircuits. Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 MIL-HDBK-780 - List of Standard Microcircuit Drawings. Standard Microcircuit Drawings. (Copies of these documents are available online at http://quicksearch.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements for device classes Q and V shall be in accordance with MIL-PRF-38535 as specified herein, or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. 3.1.1 Microcircuit die. For the requirements of microcircuit die, see appendix A to this document. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38535 and herein for device classes Q and V. 3.2.1 Case outlines. The case outlines shall be in accordance with 1.2.4 herein and figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2. 3.2.3 Radiation exposure circuit. The radiation exposure circuit shall be maintained by the manufacturer under document revision level control and shall be made available to the preparing and acquiring activity upon request. 3.3 Electrical performance characteristics and postirradiation parameter limits. Unless otherwise specified herein, the electrical performance characteristics and postirradiation parameter limits are as specified in table I and shall apply over the full ambient operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table IIA. The electrical tests for each subgroup are defined in table I. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 4 3.5 Marking. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturer's PIN may also be marked. For packages where marking of the entire SMD PIN number is not feasible due to space limitations, the manufacturer has the option of not marking the "5962-" on the device. For RHA product using this option, the RHA designator shall still be marked. Marking for device classes Q and V shall be in accordance with MIL-PRF-38535. Special marking for device classes Q and V for case outline X. The marking of the PIN number may be reduced to the RHA designator, the 5 digit drawing designator, and the device class (for example, F00523V for device class V on the 01 device type). The date code may be reduced to 3 digits (for example, 026 where 0 is the last digit of the year and 26 is the seal week) for device class Q and V. Device type 01 part number marking for device class V – F00523V. Device type 02 part number marking for device class V – F00523V2. 3.5.1 Certification/compliance mark. The certification mark for device classes Q and V shall be a "QML" or "Q" as required in MIL-PRF-38535. 3.6 Certificate of compliance. For device classes Q and V, a certificate of compliance shall be required from a QML-38535 listed manufacturer in order to supply to the requirements of this drawing (see 6.6.1 herein). The certificate of compliance submitted to DLA Land and Maritime-VA prior to listing as an approved source of supply for this drawing shall affirm that the manufacturer's product meets, for device classes Q and V, the requirements of MIL-PRF-38535 and herein. 3.7 Certificate of conformance. A certificate of conformance as required for device classes Q and V in MIL-PRF-38535 shall be provided with each lot of microcircuits delivered to this drawing. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 5 TABLE I. Electrical performance characteristics. Test Reference voltage Symbol VREF Conditions 1/ 2/ 3/ -55°C ≤ TA ≤ +125°C unless otherwise specified ∆VZ / 400 µA ≤ IR ≤ 10 mA M,D,P,L,R,F Shunt resistance rZ 4/ M,D,P,L,R,F 1/ Unit 2.495 2.505 2,3 2.480 2.510 1 2.49 2.515 -6 +6 2,3 -10 +10 1 -15 +15 0 0.6 2,3 0 1.0 1 0 1.5 1 IR = 1 mA Limits Max 1 ∆IZ Device type Min 1 IL = 1 mA M,D,P,L,R,F Zener voltage versus zener current Group A subgroups 01, 02 01, 02 01, 02 V mV Ω RHA device type 01 supplied to this drawing will meet all levels M, D, P, L, R, and F of irradiation. However, device type 01 is only tested at the “F” level in accordance with MIL-STD-883 method 1019 condition A (see 1.5 herein). RHA device type 02 supplied to this drawing will meet all levels M, D, P, L, R, and F of irradiation for condition A and levels M, D, P, and L for condition D. However, device type 02 is only tested at the “F” level in accordance with MIL-STD-883, method 1019, condition A and tested at the “L” level in accordance with MIL-STD-883, method 1019, condition D (see 1.5 herein). Pre and post irradiation values are identical unless otherwise specified in table I. When performing post irradiation electrical measurements for any RHA level, TA = +25°C. 2/ RHA device type 01 may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effects. Radiation end point limits for the noted parameters are guaranteed only for the conditions specified in MIL-STD-883, method 1019, condition A. 3/ Device is tested with 10 µF shunt capacitance connected from V+ to V-, which provides optimum stability. This reference is susceptible to output oscillation for a certain range of shunt capacitance. Shunt capacitance values from 1 nF to 3 µF inclusive should be avoided. 4/ This parameter is guaranteed but not tested. This parameter is characterized upon initial design or process changes which affect this characteristic. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 6 Bottom view Symbol Inches Millimeters Notes Min Max Min Max A 0.065 0.085 1.65 2.16 φb 0.016 0.021 0.41 0.53 φD 0.209 0.230 5.31 5.84 φD1 0.178 0.195 4.52 4.95 e 0.100 BSC 2.54 BSC e1 0.050 BSC 1.27 BSC F --- 0.040 --- 1.02 j 0.028 0.048 0.71 1.22 k 0.036 0.046 0.91 1.17 L 0.500 --- 12.70 1 --- α 45° 45° 2 N 3 3 3 NOTES: 1. Measured from maximum diameter of the actual device. 2. Measured from tab centerline. 3. N is number of leads. 4. The U.S. government preferred system of measurement is the metric SI system. However, since this item was originally designed using inch-pound units of measurement, in the event of conflict between the metric and inch-pound units, the inch-pound units shall take precedence. FIGURE 1. Case outline. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 7 Device types Case outlines Terminal number 01, 02 X Y Terminal symbol 1 ADJUST V+ 2 V+ ADJUST 3 Vsee note V- NOTE: For case X only, pin 3 is electrically tied to the case. FIGURE 2. Terminal connections. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 8 4. VERIFICATION 4.1 Sampling and inspection. For device classes Q and V, sampling and inspection procedures shall be in accordance with MIL-PRF-38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. 4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and shall be conducted on all devices prior to qualification and technology conformance inspection. 4.2.1 Additional criteria for device classes Q and V. a. The burn-in test duration, test condition and test temperature, or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under document revision level control of the device manufacturer's Technology Review Board (TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. b. Interim and final electrical test parameters shall be as specified in table IIA herein. c. Additional screening for device class V beyond the requirements of device class Q shall be as specified in MIL-PRF-38535, appendix B. 4.3 Qualification inspection for device classes Q and V. Qualification inspection for device classes Q and V shall be in accordance with MIL-PRF-38535. Inspections to be performed shall be those specified in MIL-PRF-38535 and herein for groups A, B, C, D, and E inspections (see 4.4.1 through 4.4.4). 4.4 Conformance inspection. Technology conformance inspection for classes Q and V shall be in accordance with MIL-PRF-38535 including groups A, B, C, D, and E inspections, and as specified herein. 4.4.1 Group A inspection. a. Tests shall be as specified in table IIA herein. b. Subgroups 4, 5, 6, 7, 8, 9, 10, and 11 in table I, method 5005 of MIL-STD-883 shall be omitted. 4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table IIA herein. 4.4.2.1 Additional criteria for device classes Q and V. The steady-state life test duration, test condition and test temperature, or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The test circuit shall be maintained under document revision level control by the device manufacturer's TRB in accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-STD-883. 4.4.3 Group D inspection. The group D inspection end-point electrical parameters shall be as specified in table IIA herein. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 9 TABLE IIA. Electrical test requirements. Test requirements Interim electrical parameters (see 4.2) Final electrical parameters (see 4.2) Group A test requirements (see 4.4) Group C end-point electrical parameters (see 4.4) Group D end-point electrical parameters (see 4.4) Group E end-point electrical parameters (see 4.4) 1 Subgroups (in accordance with MIL-PRF-38535, table III) Device Device class Q class V 1 1,2,3 1/ 1,2,3 2/ 3/ 1,2,3 1,2,3 1,2,3 1,2,3 3/ 1 1 1 1 1/ PDA applies to subgroup 1. 2/ PDA applies to subgroup 1 and deltas. 3/ Delta limits as specified in table IIB herein shall be required where specified, and the delta values shall be completed with reference to the zero hour electrical parameters (see table I). TABLE IIB. Delta parameters (+25°C). Parameters Delta limits VREF ±2 mV ∆VZ / ∆IZ ±1 mV 4.4.4 Group E inspection. Group E inspection is required only for parts intended to be marked as radiation hardness assured (see 3.5 herein). a. End-point electrical parameters shall be as specified in table IIA herein. b. For device classes Q and V, the devices or test vehicle shall be subjected to radiation hardness assured tests as specified in MIL-PRF-38535 for the RHA level being tested. All device classes must meet the postirradiation end-point electrical parameter limits as defined in table I at TA = +25°C ±5°C, after exposure, to the subgroups specified in table IIA herein. 4.4.4.1 Total dose irradiation testing. Total dose irradiation testing shall be performed in accordance with MIL-STD-883 method 1019, condition A and as specified herein for device types 01 and 02. In addition, for device type 02 a low dose rate test shall be performed in accordance with MIL-STD-883 method 1019, condition D and as specified herein. 5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535 for device classes Q and V. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 10 6. NOTES 6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications (original equipment), design applications, and logistics purposes. 6.1.1 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor prepared specification or drawing. 6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal. 6.3 Record of users. Military and industrial users should inform DLA Land and Maritime when a system application requires configuration control and which SMD's are applicable to that system. DLA Land and Maritime will maintain a record of users and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices (FSC 5962) should contact DLA Land and Maritime-VA, telephone (614) 692-8108. 6.4 Comments. Comments on this drawing should be directed to DLA Land and Maritime-VA, Columbus, Ohio 43218-3990, or telephone (614) 692-0540. 6.5 Abbreviations, symbols, and definitions. The abbreviations, symbols, and definitions used herein are defined in MIL-PRF-38535 and MIL-HDBK-1331. 6.6 Sources of supply. 6.6.1 Sources of supply for device classes Q and V. Sources of supply for device classes Q and V are listed in MIL-HDBK-103 and QML-38535. The vendors listed in MIL-HDBK-103 and QML-38535 have submitted a certificate of compliance (see 3.6 herein) to DLA Land and Maritime-VA and have agreed to this drawing. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 11 APPENDIX A APPENDIX A FORMS A PART OF SMD 5962-00523 A.1 SCOPE A.1.1 Scope. This appendix establishes minimum requirements for microcircuit die to be supplied under the Qualified Manufacturers List (QML) Program. QML microcircuit die meeting the requirements of MIL-PRF-38535 and the manufacturers approved QM plan for use in monolithic microcircuits, multi-chip modules (MCMs), hybrids, electronic modules, or devices using chip and wire designs in accordance with MIL-PRF-38534 are specified herein. Two product assurance classes consisting of military high reliability (device class Q) and space application (device class V) are reflected in the Part or Identification Number (PIN). When available, a choice of Radiation Hardiness Assurance (RHA) levels are reflected in the PIN. A.1.2 PIN. The PIN is as shown in the following example: 5962 F Federal stock class designator \ RHA designator (see A.1.2.1) 00523 01 V 9 A Device type (see A.1.2.2) Device class designator (see A.1.2.3) Die code Die details (see A.1.2.4) / \/ Drawing number A.1.2.1 RHA designator. Device classes Q and V RHA identified die meet the MIL-PRF-38535 specified RHA levels. A dash (-) indicates a non-RHA die. A.1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function IS-1009RH IS-1009EH Radiation hardened, 2.5 V shunt regulator diode Radiation hardened, 2.5 V shunt regulator diode 01 02 A.1.2.3 Device class designator. Device class Q or V STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 Device requirements documentation Certification and qualification to the die requirements of MIL-PRF-38535 SIZE 5962-00523 A REVISION LEVEL L SHEET 12 APPENDIX A APPENDIX A FORMS A PART OF SMD 5962-00523 A.1.2.4 Die details. The die details designation is a unique letter which designates the die's physical dimensions, bonding pad location(s) and related electrical function(s), interface materials, and other assembly related information, for each product and variant supplied to this appendix. A.1.2.4.1 Die physical dimensions. Die type Figure number 01 02 A-1 A-2 A.1.2.4.2 Die bonding pad locations and electrical functions. Die type Figure number 01 02 A-1 A-2 A.1.2.4.3 Interface materials. Die type Figure number 01 02 A-1 A-2 A.1.2.4.4 Assembly related information. Die type Figure number 01 02 A-1 A-2 A.1.3 Absolute maximum ratings. See paragraph 1.3 herein for details. A.1.4 Recommended operating conditions. See paragraph 1.4 herein for details. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 13 APPENDIX A APPENDIX A FORMS A PART OF SMD 5962-00523 A.2 APPLICABLE DOCUMENTS. A.2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STANDARD MIL-STD-883 - Test Method Standard Microcircuits. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at http://quicksearch.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) A.2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. A.3 REQUIREMENTS A.3.1 Item requirements. The individual item requirements for device classes Q and V shall be in accordance with MIL-PRF-38535 and as specified herein or as modified in the device manufacturer’s Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. A.3.2 Design, construction and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38535 and herein and the manufacturer’s QM plan for device classes Q and V. A.3.2.1 Die physical dimensions. The die physical dimensions shall be as specified in A.1.2.4.1 and on figure A-1. A.3.2.2 Die bonding pad locations and electrical functions. The die bonding pad locations and electrical functions shall be as specified in A.1.2.4.2 and on figure A-1. A.3.2.3 Interface materials. The interface materials for the die shall be as specified in A.1.2.4.3 and on figure A-1. A.3.2.4 Assembly related information. The assembly related information shall be as specified in A.1.2.4.4 and on figure A-1. A.3.2.5 Radiation exposure circuit. The radiation exposure circuit shall be as defined in paragraph 3.2.3 herein. A.3.3 Electrical performance characteristics and post-irradiation parameter limits. Unless otherwise specified herein, the electrical performance characteristics and post-irradiation parameter limits are as specified in table I of the body of this document. A.3.4 Electrical test requirements. The wafer probe test requirements shall include functional and parametric testing sufficient to make the packaged die capable of meeting the electrical performance requirements in table I. A.3.5 Marking. As a minimum, each unique lot of die, loaded in single or multiple stack of carriers, for shipment to a customer, shall be identified with the wafer lot number, the certification mark, the manufacturer’s identification and the PIN listed in A.1.2 herein. The certification mark shall be a “QML” or “Q” as required by MIL-PRF-38535. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 14 APPENDIX A APPENDIX A FORMS A PART OF SMD 5962-00523 A.3.6 Certification of compliance. For device classes Q and V, a certificate of compliance shall be required from a QML-38535 listed manufacturer in order to supply to the requirements of this drawing (see A.6.4 herein). The certificate of compliance submitted to DLA Land and Maritime -VA prior to listing as an approved source of supply for this appendix shall affirm that the manufacturer’s product meets, for device classes Q and V, the requirements of MIL-PRF-38535 and the requirements herein. A.3.7 Certificate of conformance. A certificate of conformance as required for device classes Q and V in MIL-PRF-38535 shall be provided with each lot of microcircuit die delivered to this drawing. A.4 VERIFICATION A.4.1 Sampling and inspection. For device classes Q and V, die sampling and inspection procedures shall be in accordance with MIL-PRF-38535 or as modified in the device manufacturer’s Quality Management (QM) plan. The modifications in the QM plan shall not affect the form, fit, or function as described herein. A.4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and as defined in the manufacturer’s QM plan. As a minimum, it shall consist of: a. Wafer lot acceptance for class V product using the criteria defined in MIL-STD-883, method 5007. b. 100% wafer probe (see paragraph A.3.4 herein). c. 100% internal visual inspection to the applicable class Q or V criteria defined in MIL-STD-883, method 2010 or the alternate procedures allowed in MIL-STD-883, method 5004. A.4.3 Conformance inspection. A.4.3.1 Group E inspection. Group E inspection is required only for parts intended to be identified as radiation assured (see A.3.5 herein). RHA levels for device classes Q and V shall be as specified in MIL-PRF-38535. End point electrical testing of packaged die shall be as specified in table II herein. Group E tests and conditions are as specified in paragraphs 4.4.4 and 4.4.4.1 herein. A.5 DIE CARRIER A.5.1 Die carrier requirements. The requirements for the die carrier shall be accordance with the manufacturer’s QM plan or as specified in the purchase order by the acquiring activity. The die carrier shall provide adequate physical, mechanical and electrostatic protection. A.6 NOTES A.6.1 Intended use. Microcircuit die conforming to this drawing are intended for use in microcircuits built in accordance with MIL-PRF-38535 or MIL-PRF-38534 for government microcircuit applications (original equipment), design applications, and logistics purposes. A.6.2 Comments. Comments on this appendix should be directed to DLA Land and Maritime -VA, Columbus, Ohio, 43218-3990 or telephone (614)-692-0540. A.6.3 Abbreviations, symbols, and definitions. The abbreviations, symbols, and definitions used herein are defined in MIL-PRF-38535 and MIL-HDBK-1331. A.6.4 Sources of supply for device classes Q and V. Sources of supply for device classes Q and V are listed in QML-38535. The vendors listed within MIL-HDBK-103 and QML-38535 have submitted a certificate of compliance (see A.3.6 herein) to DLA Land and Maritime -VA and have agreed to this drawing. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 15 APPENDIX A APPENDIX A FORMS A PART OF SMD 5962-00523 Die physical dimensions. Die size: 50 mils x 70 mils Die thickness: 14 mils ± 1 mils Interface materials. Top metallization: Al Si Cu 16.0 kÅ ± 2 kÅ Backside metallization: None (Silicon) Glassivation. Type: Nitride (Si3N4) Nitride thickness: 4 kÅ ± 1 kÅ Substrate: HFSTDB: Single-poly dielectrically isolated complementary bipolar Assembly related information. Substrate potential: Unbiased Special assembly instructions: None FIGURE A-1. Die bonding pad locations and electrical functions. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 16 APPENDIX A APPENDIX A FORMS A PART OF SMD 5962-00523 Die physical dimensions. Die size: 50 mils x 70 mils Die thickness: 14 mils ± 1 mils Interface materials. Top metallization: Al Si Cu 16.0 kÅ ± 2 kÅ Backside metallization: None (Silicon) Glassivation. Type: Silox (Si02) 1:6:1 Thickness: 8 kÅ ± 0.8 kÅ (1 kÅ undopped, 6 kÅ dopped, cap 1 kÅ undopped) Substrate: HFSTDB: Single-poly dielectrically isolated complementary bipolar Assembly related information. Substrate potential: Unbiased Special assembly instructions: None FIGURE A-2. Die bonding pad locations and electrical functions. STANDARD MICROCIRCUIT DRAWING DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 DSCC FORM 2234 APR 97 SIZE 5962-00523 A REVISION LEVEL L SHEET 17 STANDARD MICROCIRCUIT DRAWING BULLETIN DATE: 13-09-10 Approved sources of supply for SMD 5962-00523 are listed below for immediate acquisition information only and shall be added to MIL-HDBK-103 and QML-38535 during the next revision. MIL-HDBK-103 and QML-38535 will be revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a certificate of compliance has been submitted to and accepted by DLA Land and Maritime-VA. This information bulletin is superseded by the next dated revision of MIL-HDBK-103 and QML-38535. DLA Land and Maritime maintains an online database of all current sources of supply at http://www.landandmaritime.dla.mil/Programs/Smcr/. Standard microcircuit drawing PIN 1/ Vendor CAGE number Vendor similar PIN 2/ 5962F0052301QXC 34371 IS2-1009RH-8 5962F0052301QYC 34371 ISYE-1009RH-8 5962F0052301VXC 34371 IS2-1009RH-Q 5962F0052301VYA 3/ ISYES-1009RH-Q 5962F0052301VYC 34371 ISYE-1009RH-Q 5962F0052301V9A 34371 IS0-1009RH-Q 5962F0052302VXC 34371 IS2-1009EH-Q 5962F0052302VYC 34371 ISYE-1009EH-Q 5962F0052302V9A 34371 IS0-1009EH-Q 1/ The lead finish shown for each PIN representing a hermetic package is the most readily available from the manufacturer listed for that part. If the desired lead finish is not listed contact the vendor to determine its availability. 2/ Caution. Do not use this number for item acquisition. Items acquired to this number may not satisfy the performance requirements of this drawing. 3/ Not available from approved source of supply. Vendor CAGE number 34371 Vendor name and address Intersil Corporation 1001 Murphy Ranch Road Milpitas, CA 95035-6803 The information contained herein is disseminated for convenience only and the Government assumes no liability whatsoever for any inaccuracies in the information bulletin.