www.osram.com/boxled MAY 2013 Technical application guide BoxLED Side and BoxLED Side Plus CONTENT Content 1. Product overview BoxLED Side and BoxLED Side Plus 3 6. Application overview 14 1.1. General features 3 6.1. Recommended dimensions for light boxes 14 1.2. Applications 3 6.2. Dimming matrix 15 1.3. BoxLED mounting profile BX-MP 4 6.3. Power output rating 15 1.4. Side lighting 4 1.5. Technical data at a glance 5 7. Thermal properties 16 7.1. Casing temperature at the Tc point 16 2. Product overview OPTOTRONIC power supplies 6 7.2. Measuring the Tc temperature 17 3. System combinations LED modules – OPTOTRONIC power supplies 8 8. Installation instructions 18 4. Product identifiers 9 9. Standards and regulations for LED modules and power supplies 20 5. Electrical properties 11 10. Notes 21 5.1. Electrical connections 11 10.1. General notes 21 5.2. Electrical connectors 12 10.2. Safety information 21 11. Tools and links 22 5.2.1. General 12 5.2.2. Overview of connectors 13 Disclaimer: All the information in this guide has been produced with the utmost care. However, OSRAM does not accept any liability for possible errors, changes and/or omissions. Please check www.osram.com/boxled to see whether a more recent version of this guide is available, or get in touch with your sales contact. 2 PRODUCT OVERVIEW BoxLED Side AND BoxLED Side Plus 1. Product overview BoxLED Side and BoxLED Side Plus 1.1. General features • Maximum versatility for side lighting • Quick and easy installation by click-in of the module into the BoxLED mounting profile (screw connection and sticking also possible) • Optimized elliptical lenses provide uniform illumination of light boxes • Type of protection for LED modules: IP66 • Optimal module operation in combination with an OPTOTRONIC power supply 1.2. Applications • Illuminated advertising • Side lighting of single and double-sided light boxes BoxLED Side BoxLED Side Plus BoxLED Side All figures in mm BoxLED Side Plus All figures in mm 3 PRODUCT OVERVIEW BoxLED Side AND BoxLED Side Plus 1.3. BoxLED mounting profile BX-MP The universal mounting profile for all types of BoxLED modules provides the basis for quick and easy installation in single-sided and double-sided light boxes. 1.4. Side lighting Single-sided light boxes: Single-sided light-emitting surface Double-sided light boxes: Double-sided light-emitting surfaces 1 2 3 4 Slot holes for the mounting of the profile on the rear board or side board of the light box. 2 Holes for the easy installation of a mounting grid. The constant hole spacing of 55 mm provides consistent pitches of LED modules without measuring. 3 Square holes for simple fixing of electrical cables with cable ties. 4 Embossings/edges for the easy click-in of the individual LED modules (Click & Play). 1 Direction of light injection Direction of light injection Single-sided side lighting Double-sided side lighting For low luminance For medium luminance Direction of light injection Four-sided side lighting For high luminance 4 PRODUCT OVERVIEW BoxLED Side AND BoxLED Side Plus 1.5. Technical data at a glance Product reference Product number Light color No. of LED modules per chain (no. of LEDs per module) Rated output per chain (per module) [W]1) Luminous Beam flux per chain angle [°]1) (per module) [lm]1) Color temperature [K]1) DC voltage [V]1) Standard pack/ pcs. BX03SAW4F-765 4008321641427 White 8 (3) 60 (7.5) 3932 (491.5) 12 x 65 6500 12 1 BX03SAW4F-840 4008321693365 White 8 (3) 60 (7.5) 3276 (409.5) 12 x 65 4000 12 1 BX03SAW4F-830 4008321693204 White 8 (3) 60 (7.5) 3108 (388.5) 12 x 65 3000 12 1 BoxLED Side BoxLED Side Plus BX06SAW4F-765 4008321828606 White 32 (6) 115.2 (3.6) 9280 (290) 12 x 67 6500 24 1 BX06SAW4F-840 4008321828682 White 32 (6) 115.2 (3.6) 7680 (240) 12 x 67 4000 24 1 BX06SAW4F-830 4008321828767 White 32 (6) 115.2 (3.6) 7680 (240) 12 x 67 3000 24 1 – – – – – – – 24 BoxLED mounting profile BX-MP 4008321981110 Modules are perfectly matched to 12/24 V OSRAM OPTOTRONIC power supplies. For current photometric data and important safety, installation and application information, see www.osram.com/led-systems. 1) In view of the complex manufacturing process for light-emitting diodes, the specified typical values for the technical LED parameters are merely statistical values that do not necessarily correspond to the actual technical parameters of an individual product; individual products may vary from the typical values. 5 PRODUCT OVERVIEW OPTOTRONIC POWER SUPPLIES 2. Product overview OPTOTRONIC power supplies 12 V range for BoxLED Side Power supply OT 15/220-240/12 P OT 30/220-240/12 P OT 60/220-240/12 P OT 120/220-240/12 P AC voltage, nominal 220–240 VAC 220–240 VAC 220–240 VAC 220–240 VAC Output voltage 12.5 VDC ± 0.5 V 12.5 VDC ± 0.5 V 12.5 VDC ± 0.5 V 12.5 VDC ± 0.5 V Protection class and IP rating (type of protection) Class II, IP66 Class II, IP66 Class II, IP67 Class I, IP67 Maximum load 15 W 30 W 60 W 120 W Power factor > 0.5 full load @ 230 VAC > 0.95 full load @ 230 VAC > 0.90 half load @ 230 VAC > 0.98 full load @ 230 VAC > 0.93 half load @ 230 VAC > 0.98 full load @ 230 VAC > 0.95 half load @ 230 VAC Ambient temperature range -25 to +55 °C -25 to +55 °C -25 to +55 °C -25 to +55 °C Surge capability L-N: 4 kV L-N: 4 kV L-N: 3 kV L-N: 3 kV, L/N – PE: 6 kV No-load proof Yes Yes Yes Yes Overload/short-circuit protection Automatic, reversible Automatic, reversible Automatic, reversible Automatic, reversible Overheating protection Automatic, reversible Automatic, reversible Automatic, reversible Automatic, reversible Cable length Input side/output side ~ 300 mm/~ 300 mm Input side/output side ~ 300 mm/~ 300 mm Input side/output side ~ 500 mm/~ 500 mm Input side/output side ~ 500 mm/~ 500 mm Dimensions (L x W x H) 237 x 20 x 22 mm 220 x 40 x 22 mm 180 x 50 x 34 mm 250 x 60 x 39 mm Conformity CE, ENEC, CB CE, ENEC, CB CE, ENEC, CB CE, ENEC, CB Product number 4052899905559 4052899905542 4008321790811 4008321790835 OT 15/220-240/12 P OT 60/220-240/12 P 22 12 34 20 14 50 14 228 237 171 180 All figures in mm All figures in mm OT 30/220-240/12 P OT 120/220-240/12 P 22 14 39 40 211 220 All figures in mm 15 60 15 241 250 All figures in mm 6 PRODUCT OVERVIEW OPTOTRONIC POWER SUPPLIES 24 V range for BoxLED Side Plus Power supply OT 80/220-240/24 P OT 80/220-240/24 DIM P OT 120/220-240/24 P OT 120/220-240/24 DIM P OT 240/220-240/24 P OT 240/220-240/24 DIM P AC voltage, nominal 220–240 VAC 220–240 VAC 220–240 VAC Output voltage 24.0 VDC - 0.5/+ 1.0 V 24.0 VDC - 0.5/+ 1.0 V 24.0 VDC - 0.5/+ 1.0 V Protection class and IP rating (type of protection) Class II, IP67 Class I, IP67 Class I, IP67 Maximum load 80 W 120 W 240 W Power factor > 0.95 full load @ 230 VAC > 0.90 half load @ 230 VAC > 0.95 full load @ 230 VAC > 0.90 half load @ 230 VAC > 0.95 full load @ 230 VAC > 0.90 half load @ 230 VAC Ambient temperature range -25 to +55 °C -25 to +55 °C -25 to +55 °C Surge capability L-N: 3 kV L-N: 3 kV, L/N – Ground: 6 kV L-N: 3 kV, L/N – Ground: 6 kV No-load proof Yes Yes Yes Overload/short-circuit protection Automatic, reversible Automatic, reversible Automatic, reversible Overheating protection Automatic, reversible Automatic, reversible Automatic, reversible Cable length Input side/output side ~ 300 mm/~ 300 mm Input side/output side ~ 300 mm/~ 300 mm Input side/output side ~ 300 mm/~ 300 mm Dimensions (L x W x H) 250 x 50 x 34 mm 250 x 60 x 39 mm 250 x 80 x 39 mm Conformity CE, ENEC CE, ENEC CE, ENEC Product number non-dim version 4008321981684 4008321981707 4008321981721 Product number dim version 4008321981677 4008321981691 4008321981714 OT 80/220-240/24 (DIM) P OT 240/220-240/24 (DIM) P 12 34 14 39 14 50 14 16 16 80 16 241 250 241 250 All figures in mm All figures in mm OT 120/220-240/24 (DIM) P 14 39 15 60 15 241 250 All figures in mm 7 SYSTEM COMBINATIONS LED MODULES – OPTOTRONIC POWER SUPPLIES 3. System combinations LED modules – OPTOTRONIC power supplies BoxLED Side Maximum no. of chains per power supply Maximum no. of modules per power supply OT 15/220-240/12 P 1/4 2 OT 30/220-240/12 P 1/2 4 OT 60/220-240/12 P 1 8 OT 120/220-240/12 P 1) 2 16 BoxLED Side Plus Maximum no. of chains per power supply Maximum no. of modules per power supply OT 80/220-240/24 (DIM) P 2/3 21 OT 120/220-240/24 (DIM) P 1 32 OT 240/220-240/24 (DIM) P2) 2 64 Electrical connection is made by the connecting cables of the module. 1) If more than 8 LED modules (= a complete LED chain) are to be connected to a 120 W OPTOTRONIC power supply, there must be a new separate electrical feed. A common star point is also possible. 2) If more than 32 LED modules (= a complete LED chain) are to be connected to a 240 W OPTOTRONIC power supply, there must be a new separate electrical feed. A common star point is also possible. 8 PRODUCT IDENTIFIERS 4. Product identifiers BoxLED Side: BX = BoxLED 03 = 3 LEDs per LED module S = Side A = Version A W4F = White/4th generation/fine binning 765 = CRI + CCT = CRI 70 + 6500 K Binning Color temperature Production code Total wattage of one chain Voltage BoxLED Side Plus: BX = BoxLED 06 = 6 LEDs per LED module S = Side A = Version A W4F = White/4th generation/fine binning 765 = CRI + CCT = CRI 70 + 6500 K Module code Color temperature Date code Total wattage of one chain Voltage 9 PRODUCT IDENTIFIERS OPTOTRONIC power supplies: Output voltage Input voltage Standards and regulations OSRAM ident code Line current, IP rating European norms nominal electrical certification Power factor Primary side Input side Conformity mark of the European Community Casing temperature at the Tc point Max. casing temperature in the case of fault Secondary side Output side 10 ELECTRICAL PROPERTIES 5. Electrical properties 5.1. Electrical connections We recommend the following cable lengths and cable cross-sections (see page 12) for the electrical connections between the LED chains and the connections to the OPTOTRONIC power supplies. Maximum secondary cable length [m] BoxLED Side 20 100 90 80 70 60 50 40 30 20 10 0 AWG16/1.23 mm2 AWG14/2.08 mm2 AWG13/2.62 mm2 1.5 mm2 2.5 mm2 10 0 45 W 6 modules 3/4 chain 15 W 2 modules 1/4 chain 30 W 4 modules 1/2 chain 45 W 6 modules 3/4 chain 60 W 8 modules 1 chain 60 W 8 modules 1 chain LED module power [W] Please see disclaimer and notes on page 12. Maximum secondary cable length [m] BoxLED Side Plus 20 100 90 80 70 60 50 40 30 20 10 0 AWG16/1.23 mm2 AWG14/2.08 mm2 AWG13/2.62 mm2 1.5 mm2 2.5 mm2 10 0 57.6 W 24 modules 3/4 chain 115.2 W 32 modules 1 chain 115.2 W 28.8 W 57.6 W 86.4 W 8 modules 16 modules 24 modules 32 modules 1 chain 1/4 chain 1/2 chain 3/4 chain LED module power [W] Please see disclaimer and notes on page 12. Power supply LED module LED module LED module Max. secondary length = power supply – first LED module + wire extension LED module – LED module + ... 11 ELECTRICAL PROPERTIES 5.2. Electrical connectors Recommended cable cross-section for connecting an LED chain to other LED modules [mm2] Product Type of cable AWG A [mm2] Cable cross-section for cable extension [mm²] BoxLED Side Multi-wire (stranded) 16 1.23 ≥ 1.23 BoxLED Side Plus Multi-wire (stranded) 18 0.785 ≥ 0.785 Disclaimer: In terms of electromagnetic compatibility (EMC), the maximum permitted cable length is 10 meters (please refer to the technical data sheet of the applied OSRAM OPTOTRONIC power supply). Users are responsible to ensure EMC. Notes: We recommend to use the LED modules only in combination with OSRAM OPTOTRONIC power supplies. The maximum secondary length is the maximum cable length between power supply and the first LED module of a chain plus the wire extensions between the LED modules (see illustration on page 11). 5.2.1. General Electrical connectors are manufactured in many different versions, including screw-type terminals, wire nuts, plug connectors and joining terminals (connectors). • Use only appropriate cables and connectors to link the LED modules to the OPTOTRONIC power supplies. • Electrical terminals must not be used where they may be directly exposed to the weather without adequate protection. For outdoor applications, plug connectors (without moisture protection) must therefore be protected by IP junction boxes or light boxes. BoxLED Side (Plus) module Wrong: The terminal is on the floor Light box BoxLED Side (Plus) module Correct: The terminal is raised by bending both cables up Light box If you are using plug connectors that do not have IP protection (moisture protection), make sure that the openings are always pointing downwards. 12 ELECTRICAL PROPERTIES 5.2.2. Overview of connectors Among others, the following standard terminals are suitable for the electrical connections between the LED chains and the connections to the OPTOTRONIC power supplies: Manufacturer Reference Type of cable* Maximum outer diameter AWG cable cross-section Operating temperature Special properties 3M 316IR Single-wire/multi-wire 0.160" (4.064 mm) AWG22–16 (0.34–1.305 mm²) Max. 105 ºC (221 ºF) UL-listed, standard 486C, UL file E23438 3M 314 Single-wire/multi-wire 0.082" (2.08 mm) AWG22–14 (0.34–2.5 mm2) Max. 105 ºC (221 ºF) Sealed against moisture WAGO Series 222 Single-wire/multi-wire AWG28–12 (0.09–4.0 mm2) Max. 85 ºC (185 ºF) PHOENIX JBC 2.5/X Single-wire/multi-wire AWG20–14 (0.75–2.5 mm2) * Not all connectors are suitable for multi-wire and fine-wire conductors. In some cases, therefore, end sleeves must be provided. Please read the manufacturer’s instructions. 13 APPLICATION OVERVIEW 6. Application overview 6.1. Recommended dimensions for light boxes BoxLED Side and BoxLED Side Plus modules provide uniform illumination thanks to a beneficial mix of direct and indirect light. Direct and indirect light output of a single-sided light box Indirect light output at display surface Direct light output at display surface > 25 % Back plane Light-emitting surface Length of edge < 750 mm Depth X < 100 mm X/2 X/2 Length of edge > 750 mm Depth X < 250 mm X Length of edge = light distance Direct and indirect light output of a double-sided light box Indirect light output at display surface Indirect light output at display surface Direct light output at display surface > 12.5 % Direct light output at display surface > 12.5 % Front lightemitting surface Length of edge < 750 mm Depth X < 100 mm Rear lightemitting surface X/2 X/2 Length of edge > 750 mm Depth X < 250 mm X Length of edge = light distance For the illumination of light boxes, we recommend that the BoxLED Side or BoxLED Side Plus modules be arranged in the center of the light box frame to achieve a uniform distribution of light. Placing the LED module closer to the light-emitting surface increases the direct light output at this surface! 14 APPLICATION OVERVIEW 6.2. Dimming matrix Output voltage OPTOTRONIC Maximum Dimming devices output power EAN OT DIM1) OTi DALI DIM1) OTi DALI DIM LI1)2) 4050300943459 4008321061195 4008321624437 12 V/max. 5 A 24 V/max. 5 A Non-dim version Non-dim version All-in-one version (1 … 10 V) max. 60 W, max. 120 W 12 V/max. 4 A max. 48 W, 24 V/max. 4 A max. 96 W 1 … 10 V DALI DALI OT 15/220-240/12 P 4052899905559 12 V 15 W 1 1 1 OT 30/220-240/12 P 4052899905542 12 V 30 W 1 1 1 OT 60/220-240/12 P 4008321790811 12 V 60 W 1 1 1 OT 120/220-240/12 P 4008321790835 12 V 120 W 2 2 2 OT 80/220-240/24 P 4008321981684 24 V 80 W 1 1 1 OT 120/220-240/24 P 4008321981707 24 V 120 W 1 1 1 OT 240/220-240/24 P 4008321981721 24 V 240 W – – – OT 80/220-240/24 DIM P 4008321981677 24 V 80 W – – – OT 120/220-240/24 DIM P 4008321981691 24 V 120 W – – – OT 240/220-240/24 DIM P 4008321981714 24 V 240 W – – – 1) For outdoor applications, the dimming device has to be protected by an appropriate IP box. 2) For the OTi DALI DIM LI, OSRAM recommends the use of a protective housing such as the OSRAM OUTKIT (EAN: 4008321159533). 6.3. Power output rating The Φ-Uc characteristic curve in the diagram below shows a general definition of the power output depending on the control voltage of an OT DIM, OTi DALI DIM, OT 80/220-240/24 DIM P, OT 120/220-240/24 DIM P or OT 240/220-240 24 DIM P power supply. 100 90 Power output rating [%] 80 70 60 50 40 30 20 10 0 0 1 2 3 4 5 6 7 8 9 10 Control voltage Uc [V] Operation without applied control voltage (shorted) 0 % power output Operation without applied control voltage (floating) 100 % power output 15 THERMAL PROPERTIES 7. Thermal properties 7.1. Casing temperature at the Tc point The casing temperature is the temperature at a defined point on the LED casing, the Tc point. The maximum Tc temperature is the highest permitted temperature that may occur at the Tc point under the planned ambient and operating conditions in the thermally steady state. If the maximum permitted Tc temperature is exceeded, the LED module may go into a state in which the load limits on the module (LED, casing, chip, encapsulation materials) are reached. A thermal link between the BoxLED Side or BoxLED Side Plus modules and the mounting surface is not absolutely essential. Thermo-wire NiCr–Ni Mini connector “K” 1000±15 Temperature sensors Description Temperature range Length [mm] Diameter [mm] T90 1m Powerful sensor with a magnetic holding force of 90 N -30 to +550 °C 1000 40 x 25 18 25 mm 40 x 25 mm Tube sensor with flexible hook-and-loop tape Velcro® fastener for ∅ 15–150 mm 2m -10 to +100 °C 2000 For 15 – 150 20 Flexible Teflon® wire Foil sensor, self-adhesive -50 to +250 °C 1000 10 x 20 12 L 1.2 x 0.8 mm 10 x 20 mm Possible suppliers of such temperature sensors include OMEGA: www.omega.de and B+B Thermo-Technik: www.bubthermo.de 16 THERMAL PROPERTIES 7.2. Measuring the Tc temperature The indicated lifetime can only be achieved if the permitted operating temperatures at the Tc point are maintained. After the LED modules have been installed in a light box, the Tc temperature must be measured under the planned ambient and operating conditions in the thermally steady state. To do this, attach a temperature sensor to the Tc point with suitable adhesive (cyanoacrylate-free). The pictures below show the respective Tc reference point, marked by a small circle on the back of the LED modules. Permitted Tc temperatures Operating temperature at the Tc point* [°C] BoxLED Side -25 to 75 BoxLED Side Plus -25 to 95 * If the maximum temperature limits are exceeded, the lifetime of the module will be greatly reduced or the module may be destroyed. The temperature of the LED module at the Tc point should be measured in the thermally steady state by means of a temperature sensor or temperature-sensitive sticker in accordance with EN 60598-1. For the precise position of the Tc point, see the pictures below. Tc Tc point BoxLED Side Tc Tc point BoxLED Side Plus 17 INSTALLATION INSTRUCTIONS 8. Installation instructions The following instructions apply to both BoxLED Side and BoxLED Side Plus modules. In case multiple LED modules are assembled in one mounting profile, it should be ensured that the profile is not deformed or damaged by the total weight of the LED modules. 1. Measure the inside of the frame to determine the length of the mounting profiles. 2. Cut the mounting profiles to the required length. 3. Fix the mounting profiles to the internal frame of the light box and use a rule to align the profiles. 4. Remove the insulation from the cable ends of the LED modules and the power supply using a suitable tool. 5. Clean the mounting profile to ensure optimum adhesion with the LED module. 6. Remove the protective film from the adhesive strips. 7. Snap the individual modules into the profile one after the other. 8. Observe the predefined hole spacing of the mounting LED pitch of 110 mm = 2 x 55 mm hole grid (55 mm) spacing. 9. Form a cable loop between the individual LED modules and fix it to the mounting profile with cable ties to avoid shadows. 1 2 3a 3b 3c 4 5 6 7 8 9a 9b 18 INSTALLATION INSTRUCTIONS 10. View of a mounted LED module. 11. Install the power supply. 12. Connect the secondary side of the power supply to the LED modules, and the primary side to power cables using plug connectors. 13. Make sure that the openings of the plug connectors are always pointing downwards. 14. View of the installed module and OPTOTRONIC power supply. 15. View of the complete application in operation. 16. View of the complete application in operation, with acrylic panel. 10 11 12a 12b 13 14 15 16 The installation of the modules is also possible without mounting profile. Please note: All exposed metal parts (such as the mounting profile) must be grounded in accordance with the latest safety requirements. Please also read the general safety instructions on p. 21. 19 STANDARDS AND REGULATIONS FOR LED MODULES AND POWER SUPPLIES 9. Standards and regulations for LED modules and power supplies The OSRAM LED modules are perfectly matched to the electronically stabilized OSRAM OPTOTRONIC power supplies, which are protected against short-circuit, overload and overtemperature. OSRAM LED modules and OPTOTRONIC power supplies comply with all the relevant standards (see below) and ensure safe and reliable operation. LED modules Radio interference EN 55015 EMC/immunity EN 61547 Electromagnetic fields IEC 62493 Photobiological safety IEC 62471 CE Yes OPTOTRONIC power supplies Safety EN 61347-2-13 Radio interference EN 55015 Immunity EN 61547 Harmonic content EN 6100-3-2 CE Yes 20 NOTES 10. Notes 10.1. General notes • Each LED module is equipped with a pre-mounted double-sided adhesive tape which allows for optional or additional mounting. Due to varying properties of adherends and multiple external influences during the operation of the modules, OSRAM assumes no liability and provides no guarantee for a permanent adherence of the modules to the surface. OSRAM recommends fixation of the modules by means of suitable screws. • Safe operation is ensured only if the LED chains are connected in parallel. Connecting the LED chains in series is NOT recommended. Unbalanced voltage drops may lead to serious overloads and destruction of individual modules. • Make sure to take suitable ESD (electrostatic discharge) precautions when installing the modules. • If drivers other than OSRAM OPTOTRONIC power supplies are used, the output voltage must be 12.5 V ± 0.5 V for 12 VDC and 24 V - 0.5/+ 1.0 V for 24 VDC to ensure safe operation of the modules. • The LED chains must only be shortened by cutting the connecting cables between the LED modules. • The LED chains must not be used where they may be directly exposed to the weather without adequate protection. In outdoor applications, the LED chains must therefore be protected by suitable housings or covers. The LED chains cannot be operated in or under water. 10.2. Safety information Before you start assembly, please read this information carefully. • Caution: There is a risk of an electric shock. Disconnect the power supply before installing or maintaining the product. • To avoid mechanical damage due to vibration, the LED modules must be connected flush with the mounting surface. Avoid exposing the equipment to strong vibrations. • The LED modules, including the power supply, may only be installed by a qualified electrician in accordance with all the valid regulations and standards. • Ensure that the poles are connected correctly. No light will be emitted if the polarity is incorrect. In this case, simply reverse the polarity. Recommended properties of light boxes To ensure uniform illumination, a reflective matt white surface is generally recommended for all internal frame walls and back panels for light boxes. 21 TOOLS AND LINKS 11. Tools and links The following materials and tools relating to signage are available on various web pages: BackLED Plus BackLED MB and LB BoxLED Back Plus BoxLED Side and BoxLED Side Plus • Technical application guides • Product data sheets > www.osram.com/backled > www.osram.com/boxled Note: Please also read the product data sheets for the BoxLED Side and BoxLED Side Plus modules. These data sheets contain important information regarding safety and installation. The latest data sheets are available at www.osram.com/boxled Please also read the OPTOTRONIC technical guide and product data sheets, which are available at www.osram.com/optotronic LED deSIGNer for applications with channel letters • LED deSIGNer • Checklist – signage application > www.osram.com/led-designer OPTOTRONIC • Product data sheets • Technical guide • Operating instructions > www.osram.com/optotronic Others • Technical application guide – ESD protection for LED systems • Technical application guide – IP codes in accordance with IEC 60529 • Signage brochure including pocket guide • New standards for LED control gear 22 OSRAM GmbH Head Office Marcel-Breuer-Strasse 6 80807 Munich Germany Phone +49 (0)89-6213-0 Fax +49 (0)89-6213-20 20 www.osram.com 05/13 Subject to change without notice. Errors and omissions excepted. www.osram.com/boxled www.osram.de