Package Compliance Report

 Super 220
RoHS Compliance Document
Contents:
1. Composition
2. Tin Whisker Report
The information contained in this document is provided without any warranty, either expressed or implied, and
IR specifically disclaims any and all liability, including but not limited to consequential or indirect damages. July 2015
SUPER-220
Component
Material
Name
Material
Mass
(g)
Element
Name
Composition
CAS #
Substance
Mass (g)
Si
SiO2
Epoxy
Other
Cu
Fe
Sn
Ag
Sb
Al
Ni
7440-21-3
7631-86-9
90598-46-2
7440-50-8
7439-89-6
7440-31-5
7440-22-4
7440-36-0
7429-90-5
7440-02-0
0.01777
0.69713
0.13943
0.09296
1.11151
0.00559
0.01047
0.00403
0.00161
0.00770
0.01518
Material
Analysis
Weight
(%)
100%
75%
15%
10%
99%
1%
65%
25%
10%
100%
14%
Sn
7440-31-5
0.09322
86%
Chip
Silicon
0.01777
Encapsulant
Epoxy
Resin
0.92952
Lead Frame
Copper
1.11710
Die Attach
J-Alloy
0.01611
Wire Bond
Copper
Matte Tin
over
Nickel*
0.00770
Lead Finish
0.10840
Total Weight
(g)
% of Total
Weight
0.8%
31.7%
6.3%
4.2%
50.6%
0.3%
0.5%
0.2%
0.1%
0.4%
0.7%
4.2%
2.19660
*Tin whisker mitigation strategy is nickel under-plate.
This part is compliant with EU Directive 2011/65/EU (RoHS Directive) and does not contain lead, mercury,
cadmium (0.01%), hexavalent chromium, PBB or PBDE in concentrations greater than 0.1%, except as
permitted by Annex (7).
July 2015
The information contained in this document is provided without any warranty, either expressed or implied, and IR
specifically disclaims any and all liability, including but not limited to consequential or indirect damages. SUPER-220
Test Definition
Room
Temperature
Humidity
Temperature
Humidity
Unbiased
Temperature
Cycling
Test Conditions
Inspection
Total
Interval Class
Duration
1 and 2
Class 1 and 2
Products
Products
Maximum
Whisker
Length
(µm)
30± 2°C/60± 3% RH
1000 hours
4000 hours
20
55± 3°C/85± 3% RH
1000 hours
4000 hours
20
500 cycles
1500 cycles
45
-40 to 55°C to 80 to 95°C,
air to air, 10 min soak,
approx 3
Tin Whisker testing per JESD201, Environmental Acceptance Requirements for
Tin Whisker Susceptibility of Tin and Tin Alloy Surface Finish
Tin Whisker Results (number of failing whiskers)
Test
Room Temperature
Humidity Storage
Temperature
Humidity
Test
Temperature Cycling
1000 Hours
2000 Hours
3000 Hours
4000 Hours
0/24
0/24
0/24
0/24
0/24
0/24
0/24
0/24
500 Cycles
1000 Cycles
0/24
0/24
1500 Cycles
0/24
July 2015
The information contained in this document is provided without any warranty, either expressed or implied, and IR
specifically disclaims any and all liability, including but not limited to consequential or indirect damages.