Rohs/PbF Compliance

Micro-8
RoHS Compliance Document
Contents:
1. Composition
2. Solder Reflow
3. Tin Whisker Report
The information contained in this document is provided without any warranty, either expressed or implied, and IR specifically
disclaims any and all liability, including but not limited to consequential or indirect damages.
July 2014
Micro-8
Component
Material
Name
Material
Mass (g)
Chip
Silicon
0.00069
Encapsulant
Epoxy
Resin
0.01465
Lead Frame
Copper
0.00899
Die Attach
Silver
Epoxy
0.00018
Wire Bond
Lead Finish
Gold
Matte Tin*
0.00021
0.00082
Element
Name
Composition
Si
SiO2
Epoxy
Other
Cu
Fe
Ag
Epoxy
Au
Sn
Total Weight
(g)
CAS #
Substance
Mass (g)
7440-21-3
7631-86-9
90598-46-2
7440-50-8
7439-89-6
7440-22-4
90598-46-2
7440-57-7
7440-31-5
0.00069
0.01055
0.00366
0.00044
0.00877
0.00022
0.00015
0.00003
0.00021
0.00082
Material
Analysis
Weight
(%)
100%
72%
25%
3%
98%
2%
84%
16%
100%
100%
% of Total
Weight
2.7%
41.3%
14.3%
1.7%
34.3%
0.9%
0.6%
0.1%
0.8%
3.2%
0.02554
*Tin whisker mitigation strategy is 150 °C, 1 hour anneal within 24 hours of tin plating.
260 DEGREE REFLOW PROFILE
300
60 to 150 s e c
> 217 C
250
DEGREE
200
150
10 to 30
se c
> 255 C
60 to 180 s e c
150 C to 200 C
100
50
0
TIME
This part is compliant with EU Directive 2011/65/EU (RoHS Directive) and does not contain lead, mercury,
cadmium (0.01%), hexavalent chromium, PBB or PBDE in concentrations greater than 0.1%, except as
permitted by Annex (7).
The information contained in this document is provided without any warranty, either expressed or implied, and IR specifically
disclaims any and all liability, including but not limited to consequential or indirect damages.
1
July 2014
Micro-8
Test Definition
Room
Temperature
Humidity
Storage
Temperature
Humidity
Unbiased
Test Conditions
Inspection
Total
Interval Class
Duration
1 and 2
Class 1 and 2
Products
Products
Maximum
Whisker
Length
(µm)
30± 2°C/60± 3% RH
1000 hours
4000 hours
20
55± 3°C/85± 3% RH
1000 hours
4000 hours
20
-40 to 55°C to 80 to 95°C,
500 cycles
1500 cycles
air to air, 10 min soak,
approx 3
cycles
Tin Whisker testing per JESD201,
/hours
Environmental Acceptance Requirements for
Tin Whisker Susceptibility of Tin and Tin Alloy Surface Finish
Temperature
Cycling
45
Tin Whisker Results (number of failing whiskers)
Test
Room Temperature
Humidity Storage
Temperature
Humidity
Unbiase
Test
d
Temperature Cycling
1000 Hours
2000 Hours
3000 Hours
4000 Hours
0/24
0/24
0/24
0/24
0/24
0/24
0/24
0/24
500 Cycles
0/24
1000 Cycles
0/24
1500 Cycles
0/24
The information contained in this document is provided without any warranty, either expressed or implied, and IR specifically
disclaims any and all liability, including but not limited to consequential or indirect damages.
2
July 2014