EN

Strain Link with Amplifier
DSRT 22DD
Features
• Static and dynamic applications
• Integrated reset switch for automatic zero
point setting
• Measuring range ±100 up to ±750 με,
extension and compression • Voltage output
S/G Data
Electrical Data
Foil strain gage
Material
- Housing - Cover
Measuring range
±100 µe...±750 µe
(1 µe = 0,001 mm/m resp.
1 µe equals 0,001 mm strain per meter)
1.7225 chemically nickel-plated
1.4301
Output signal
±10 VDC (max. ±12 VDC)
5 pin (M12 x 1)
Characteristic curve
deviation
< 1,0% FS
Electrical connection
Application position
any
Linearity
< 0,5% FS
1 N/µε @100
0,2 N/µε @250 - 750
Hysteresis
< 0,5% FS
Repeatability
< 0,1% FS
Supply voltage range
18 - 33 VDC
Low < 1 VDC
High 5...33 VDC
Strain gage type
Mechanical Data
Sensor stiffness
Environmental Conditions
Operating temp.range
0...+70 °C
Taring "activ High"
Storage temp. range
-40...+85°C
Accessories (not included in delivery)
EMC
EN 61000-6-2
EN 61000-6-4
Series 713
Vibration IEC 60068-2-6 10 - 2000 Hz 10 g (amplitude ±0,75 mm, 10 - 58 Hz)
Connector female, control side, 5-pin, Part No. 10135462
Random IEC 60068-2-64 20 - 1000 Hz, 0,1 g /Hz
2
Shock IEC 60068-2-27
50 g / 11 ms
Protection class
IP 67
Connector female with cable, control side, 5-pin
Delivery Contents
Mounting screws
4 pcs. M6 x 25
strength class 12.9
Order Code
ESG 34CH0500G 5-pin (shielded) 5 m, PUR,
(Part No. 11046266)
ESG 34CH1000G 5-pin (shielded) 10 m, PUR,
(Part No. 10155587)
DSRT 22DD-S50100
0250
0350
0500
0750
5.6
ESG 34CH0200G 5-pin (shielded) 2 m, PUR,
(Part No. 11046264)
Measuring range 100 µε
Measuring range 250 µε Measuring range 350 µε
Measuring range 500 µε
Measuring range 750 µε
www.baumer.com
DSRT 22DD
Dimensions (mm)
Electrical Connections
PinSignal
0.1
M 12 x1
r
1
2
1+Vs
2-V
OUT
3GND
4+V
5Reset
10,2
17
3.2
1.6
( )
3
15
N8
N7
6
M6x25
4 5
OUT
HousingShield
26
14,5 ±0.1
ε
6
53 ±0.1
69
80
DSRT
5
Reset Function
Control
Controller
V Output signal
e
Input signal
Reset
Reset input (active high)
t
Reset delay (< 0,3 ms)
OUT
1
t
Reset time (< 5 ms)
t
Reset impulse (> 1 ms)
2
3
www.baumer.com
5.7