Operation Manual

AS1337 - Demo Board Manual
Step-Up Converter
Demo Board Manual
AS1337
200mA, DC-DC Step-Up Converter with Buck
Mode
www.austriamicrosystems.com/DC-DC_Step-Up/AS1337
www.austriamicrosystems.com
Revision 1.00
1-4
AS1337 - Demo Board Manual
Step-Up Converter
General Description
Board Description
D
C
A
E
B
B
I
J
F
M
L
G
Figure 1: Board Description - Connectors
K
H
G
Figure 2: Board Description – Measurement Points
Connector Description
Label
Name
Description
Info
A
B
VIN
GND
Supply Voltage
Ground
Supply voltage ranging from 0.65V to 4.5V
C
EN
Enable Input
D
E
VOUT
POK
Output Voltage
POK
Set the digital input “high” for normal operation.
For shutdown, set “low”
Output voltage ranging from 2.5V to 5.0V
high, when VOUT is within regulation
Measurement Point Description
Label
Name
Description
Info
F
G
H
I
J
K
L
VIN
GND
LX
VOUT
EN
FB
POK
Supply Voltage
Ground
External Inductor
Output Voltage
Enable Input
Feedback
POK
Measurement Points
ON: The AS1337 is enabled
M
EN
OFF: The AS1337 is disabled
Enable
No Jumper: Connect a valid enable signal
via external connector “C”.
Getting Started
The AS1337 Demoboard is designed to work with the AS1337A “Battery connected in shutdown” version.
With the resistor divider R1/R2 it is possible to adjust the VOUT.
On this Demoboard the following resistor values are mounted:
R1 = 560k and R2 = 330k VOUT = 3.3V
www.austriamicrosystems.com
Revision 1.00
2-4
AS1337 - Demo Board Manual
Step-Up Converter
Bill of Materials
Ref.
Function
Value
Description
Manufacturer
Mfg. Order Nr.
C1s
Input Capacitor
10µF
0805 / X5R / 6.3V
Murata
GRM219R60J106KE19
C2s
Output Capacitor
22µF
0805 / X5R / 6.3V
Murata
GRM21BR60J226ME39
L1
Coil
4.7µH
50mΩ / 1.82A / 6.8x6.0x2.4mm
Coilcraft
MOS6020-472ML
R1
Resistor (VOUT)
560k
0805/ ±1%
Multicomp
MC 0.1W 0805 1% 560K
R2
Resistor (VOUT)
330k
0805/ ±1%
Multicomp
MC 0.1W 0805 1% 330K
R3
RPOK
100k
0805/ ±1%
Multicomp
MC 0.1W 0805 1% 100K
U1
DC/DC Converter
ASSE
TQFN 3x3mm 8-pin
Austriamicrosystems AG
AS1337A-BTDT
Layout of Demo Board
Board schematics and layout
Figure 3: Schematics
Figure 4: Top + Bottom Layer
www.austriamicrosystems.com
Revision 1.00
3-4
AS1337 - Demo Board Manual
Step-Up Converter
Copyright
Copyright © 1997-2010, austriamicrosystems AG, Tobelbaderstraße 30, 8141 Unterpremstätten - Graz, Austria Europe. Trademarks Registered ®. All rights reserved. The material herein may not be reproduced, adapted,
merged, translated, stored, or used without the prior written consent of the copyright owner.
All products and companies mentioned are trademarks or registered trademarks of their respective companies.
Disclaimer
Devices sold by austriamicrosystems AG are covered by the warranty and patent indemnification provisions
appearing in its Term of Sale. austriamicrosystems AG makes no warranty, express, statutory, implied, or by
description regarding the information set forth herein or regarding the freedom of the described devices from
patent infringement. Austriamicrosystems AG reserves the right to change specifications and prices at any time
and without notice. Therefore, prior to designing this product into a system, it is necessary to check with
austriamicrosystems AG for current information.
This product is intended for use in normal commercial applications. Applications requiring extended temperature
range, unusual environmental requirements, or high reliability applications, such as military, medical life-support
or life-sustaining equipment are specifically not recommended without additional processing by
austriamicrosystems AG for each application. For shipments of less than 100 parts the manufacturing flow might
show deviations from the standard production flow, such as test flow or test location.
The information furnished here by austriamicrosystems AG is believed to be correct and accurate. However,
austriamicrosystems AG shall not be liable to recipient or any third party for any damages, including but not
limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect,
special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing,
performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise
or flow out of austriamicrosystems AG rendering of technical or other services.
Contact Information
Headquarters
austriamicrosystems AG
Tobelbaderstraße 30
A-8141 Unterpremstätten - Graz, Austria
T. +43 (0) 3136 500 0
F. +43 (0) 3136 5692
For Sales Offices, Distributors and Representatives, please visit:
http://www.austriamicrosystems.com/contact
www.austriamicrosystems.com
Revision 1.00
4-4