Operation Manual

austriamicrosystems AG
is now
ams AG
The technical content of this austriamicrosystems application note is still valid.
Contact information:
Headquarters:
ams AG
Tobelbaderstrasse 30
8141 Unterpremstaetten, Austria
Tel: +43 (0) 3136 500 0
e-Mail: [email protected]
Please visit our website at www.ams.com
AS1119 - Demo Board Manual
al
id
Demo Board Manual
AS1119
am
lc s
on A
te G
nt
st
il
lv
144 LED, I²C Interfaced, Cross-Plexing Driver
with a 320mA Charge-Pump
Te
ch
ni
ca
www.austriamicrosystems.com/AS1119
www.austriamicrosystems.com
Revision 1.00
1-5
AS1119 - Demo Board Manual
General Description
lv
al
id
Board Description
Figure 2: Board Description – Jumpers
am
lc s
on A
te G
nt
st
il
Figure 1: Board Description - Connectors
Connector Description
Label
Name
A
B
VDD
GND
C
USB
D
I/O
Description
Info
Supply Voltage
Ground
Supply voltage ranging from 2.7V to 5.5V
Mini USB 5-pin Connector
I²C Interface Connector
Supplies the AS1119 with 5V. Connect to a
standard USB port. This Connector is not
used for data transfer.
Connect austriamicrosystems USB Interface
Box. For a detailed Connector Description
see table below.
Note: Use only the Connectors VDD “A” and GND ”B” or USB Connector “C”. Never use both supply
possibilities at the same time!
I/O - Interface Connector “D” Description
Label
SYNC_IN /
SYNC_OUT
NC
GND
IRQ
SCL
SDA
Pin B6
A2
A3
B1
B2
B3
ni
B1
B2
B3
ch
A1
A2
A3
AS1119
ca
A1
Name
Pin E6
Pin D6
Pin C6
Jumper Description
Name
Description
E
F
J6
J5
G
SYNC
H
S1
I
J1
AD1
AD0
Sync Function. If two or more boards are connected together remove this
jumper on the board which is connected to the USB box.
Reset Button
Connector to LED boards.
For a detailed layout description of the LED boards see Application note:
APN_AS1119_Cross-Plexing_v1_00
Te
Label
www.austriamicrosystems.com
Revision 1.00
2-5
AS1119 - Demo Board Manual
Quickstart Software
am
lc s
on A
te G
nt
st
il
lv
al
id
Before starting the software make sure that the USB Power supply and the USB box are connected to the
demoboard. After start-up the software is configured (per default) to work with the 12x12 Matrix.
On the first tab ‘Demonstration 12x12 Matrix’ there are one-click-demos. Just click the demonstration you want to
display and it will be shown on the 12x12 Matrix right away. To stop the demonstration, click the Stop Playback
button.
ni
ca
For one-click-demos on the 9x16 Matrix, go to the second tab. There some demonstrations for the 9x16 matrix
can be found.
To draw your one movie or frame to display go to the third tab ‘Drawing Tool’.
ch
Operational sequence
This demo board comes with the AS1119.
Drive the IC on the demo board only with the recommended settings and values as described in the
datasheet. If not present get the datasheet for the AS1119 from www.austriamicrtosystem.com.
Te
1.
2.
First connect the power supply via connector “C” to a powered USB port and than power up the I/O Interface “D”. To power down the system disconnect first the I/O Interface and than the power supply of
the demoboard.
3.
Connect the I/O - Interface “D” to a µC or via the austriamicrosystems USB Interface Box to a PC. For
interfacing please see the corresponding datasheet of the AS1119.
If there are questions do not hesitate to contact us. See contact information at the end of this manual.
www.austriamicrosystems.com
Revision 1.00
3-5
AS1119 - Demo Board Manual
Layout of Demo Board
ca
Figure 3: Schematic
am
lc s
on A
te G
nt
st
il
lv
al
id
Board schematics and layout
Te
ch
ni
Figure 4: Top and Bottom Layer
www.austriamicrosystems.com
Revision 1.00
4-5
AS1119 - Demo Board Manual
Copyright
Copyright © 1997-2010, austriamicrosystems AG, Tobelbaderstraße 30, 8141 Unterpremstätten - Graz, Austria Europe. Trademarks Registered ®. All rights reserved. The material herein may not be reproduced, adapted,
merged, translated, stored, or used without the prior written consent of the copyright owner.
All products and companies mentioned are trademarks or registered trademarks of their respective companies.
Disclaimer
ca
am
lc s
on A
te G
nt
st
il
lv
al
id
Devices sold by austriamicrosystems AG are covered by the warranty and patent indemnification provisions
appearing in its Term of Sale. austriamicrosystems AG makes no warranty, express, statutory, implied, or by
description regarding the information set forth herein or regarding the freedom of the described devices from
patent infringement. Austriamicrosystems AG reserves the right to change specifications and prices at any time
and without notice. Therefore, prior to designing this product into a system, it is necessary to check with
austriamicrosystems AG for current information.
This product is intended for use in normal commercial applications. Applications requiring extended temperature
range, unusual environmental requirements, or high reliability applications, such as military, medical life-support
or life-sustaining equipment are specifically not recommended without additional processing by
austriamicrosystems AG for each application. For shipments of less than 100 parts the manufacturing flow might
show deviations from the standard production flow, such as test flow or test location.
The information furnished here by austriamicrosystems AG is believed to be correct and accurate. However,
austriamicrosystems AG shall not be liable to recipient or any third party for any damages, including but not
limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect,
special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing,
performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise
or flow out of austriamicrosystems AG rendering of technical or other services.
ni
Contact Information
Te
ch
Headquarters
austriamicrosystems AG
Tobelbaderstraße 30
A-8141 Unterpremstätten - Graz, Austria
T. +43 (0) 3136 500 0
F. +43 (0) 3136 5692
For Sales Offices, Distributors and Representatives, please visit:
http://www.austriamicrosystems.com/contact
www.austriamicrosystems.com
Revision 1.00
5-5