Si4435DDY Datasheet

New Product
Si4435DDY
Vishay Siliconix
P-Channel 30-V (D-S) MOSFET
FEATURES
PRODUCT SUMMARY
RDS(on) (Ω)
ID (A)d
0.024 at VGS = - 10 V
- 11.4
0.035 at VGS = - 4.5 V
- 9.4
VDS (V)
- 30
• Halogen-free According to IEC 61249-2-21
Definition
• TrenchFET® Power MOSFET
• Compliant to RoHS Directive 2002/95/EC
Qg (Typ.)
15 nC
APPLICATIONS
• Load Switches
• Battery Switch
SO-8
S
S
1
8
D
S
2
7
D
S
3
6
D
G
4
5
D
G
Top View
D
Ordering Information: Si4435DDY-T1-E3 (Lead (Pb)-free)
Si4435DDY-T1-GE3 (Lead (Pb)-free and Halogen-free)
P-Channel MOSFET
ABSOLUTE MAXIMUM RATINGS TA = 25 °C, unless otherwise noted
Parameter
Drain-Source Voltage
Gate-Source Voltage
Continuous Drain Current (TJ = 150 °C)
Symbol
VDS
VGS
TC = 25 °C
TC = 70 °C
TA = 25 °C
TA = 70 °C
Limit
- 30
± 20
ID
Continuous Source-Drain Diode Current
TC = 25 °C
TA = 25 °C
IS
Avalanche Current
Single-Pulse Avalanche Energy
L = 0.1 mH
IAS
EAS
Maximum Power Dissipation
TC = 25 °C
TC = 70 °C
TA = 25 °C
TA = 70 °C
PD
- 2.0a, b
- 20
20
5.0
3.2
2.5a, b
1.6a, b
- 55 to 150
TJ, Tstg
Operating Junction and Storage Temperature Range
V
- 11.4
- 9.1
- 8.1a, b
- 6.5a, b
- 50
- 4.1
IDM
Pulsed Drain Current
Unit
A
mJ
W
°C
THERMAL RESISTANCE RATINGS
Parameter
Maximum Junction-to-Ambienta, c
Maximum Junction-to-Foot
t ≤ 10 s
Steady State
Symbol
RthJA
RthJF
Typical
38
20
Maximum
50
25
Unit
°C/W
Notes:
a. Surface mounted on 1" x 1" FR4 board.
b. t = 10 s.
c. Maximum under Steady State conditions is 85 °C/W.
d. Based on TC = 25 °C.
Document Number: 68841
S09-0863-Rev. C, 18-May-09
www.vishay.com
1
New Product
Si4435DDY
Vishay Siliconix
SPECIFICATIONS TJ = 25 °C, unless otherwise noted
Parameter
Symbol
Test Conditions
Min.
VDS
VGS = 0 V, ID = - 250 µA
- 30
Typ.
Max.
Unit
Static
Drain-Source Breakdown Voltage
VDS Temperature Coefficient
ΔVDS/TJ
VGS(th) Temperature Coefficient
ΔVGS(th)/TJ
ID = - 250 µA
Gate-Source Threshold Voltage
VGS(th)
VDS = VGS, ID = - 250 µA
Gate-Source Leakage
IGSS
VDS = 0 V, VGS = ± 20 V
Zero Gate Voltage Drain Current
IDSS
On-State Drain Currenta
ID(on)
Drain-Source On-State Resistancea
Forward Transconductancea
Dynamicb
RDS(on)
gfs
Input Capacitance
Ciss
Output Capacitance
Coss
Reverse Transfer Capacitance
Crss
Total Gate Charge
Qg
Gate-Source Charge
Qgs
Gate-Drain Charge
Qgd
Gate Resistance
Rg
Turn-On Delay Time
Rise Time
Turn-Off DelayTime
Fall Time
Turn-On Delay Time
Rise Time
Turn-Off DelayTime
Fall Time
mV/°C
4.5
- 1.0
- 3.0
V
± 100
nA
VDS = - 30 V, VGS = 0 V
-1
VDS = - 30 V, VGS = 0 V, TJ = 55 °C
-5
VDS ≥ - 10 V, VGS = - 10 V
VGS = - 10 V, ID = - 9.1 A
- 30
0.024
VGS = - 4.5 V, ID = - 6.9 A
0.028
0.035
VDS = - 10 V, ID = - 9.1 A
23
1350
VDS = - 15 V, VGS = 0 V, f = 1 MHz
215
pF
185
VDS = - 15 V, VGS = - 10 V, ID = - 9.1 A
32
50
15
25
VDS = - 15 V, VGS = - 4.5 V, ID = - 9.1 A
4
f = 1 MHz
5.8
10
VDD = - 15 V, RL = 15 Ω
ID ≅ - 1 A, VGEN = - 10 V, Rg = 1 Ω
Ω
15
15
70
tf
12
25
td(on)
42
70
tr
nC
7.5
8
td(off)
Ω
S
45
td(off)
µA
A
0.0195
td(on)
tr
V
- 31
VDD = - 15 V, RL = 15 Ω
ID ≅ - 1 A, VGEN = - 4.5 V, Rg = 1 Ω
tf
35
60
40
70
16
30
ns
Drain-Source Body Diode Characteristics
Continous Source-Drain Diode Current
IS
Pulse Diode Forward Current
ISM
Body Diode Voltage
VSD
Body Diode Reverse Recovery Time
trr
Body Diode Reverse Recovery Charge
Qrr
Reverse Recovery Fall Time
ta
Reverse Recovery Rise Time
tb
TC = 25 °C
- 4.1
- 50
IS = - 2 A, VGS = 0 V
IF = - 2 A, dI/dt = 100 A/µs, TJ = 25 °C
A
- 0.75
- 1.2
V
34
60
ns
22
40
nC
11
23
ns
Notes:
a. Pulse test; pulse width ≤ 300 µs, duty cycle ≤ 2 %.
b. Guaranteed by design, not subject to production testing.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
2
Document Number: 68841
S09-0863-Rev. C, 18-May-09
New Product
Si4435DDY
Vishay Siliconix
TYPICAL CHARACTERISTICS 25 °C, unless otherwise noted
50
1.0
VGS = 10 V thru 5 V
0.8
VGS = 4 V
30
20
10
TC = - 55 °C
ID - Drain Current (A)
I D - Drain Current (A)
40
0.6
0.4
TC = 25 °C
0.2
VGS = 3 V
0
0.0
0.5
1.0
1.5
TC = 125 °C
0.0
0.0
2.0
1.0
1.5
2.0
2.5
VGS - Gate-to-Source Voltage (V)
Output Characteristics
Transfer Characteristics
0.05
3.0
2400
0.04
1800
C - Capacitance (pF)
R DS(on) - On-Resistance (Ω)
0.5
VDS - Drain-to-Source Voltage (V)
VGS = 4.5 V
0.03
VGS = 10 V
0.02
Ciss
1200
600
0.01
Coss
Crss
0
0
0
10
20
30
40
50
0
6
ID - Drain Current (A)
12
24
30
VDS - Drain-to-Source Voltage (V)
On-Resistance vs. Drain Current
Capacitance
10
1.8
ID = 9.1 A
ID = 9.1 A
VGS = 10 V
8
VDS = 15 V
6
VDS = 7.5 V
VDS = 22.5 V
4
1.5
(Normalized)
R DS(on) - On-Resistance
VGS - Gate-to-Source Voltage (V)
18
1.2
0.9
2
VGS = 4.5 V
0
0
9
18
27
36
0.6
- 50
- 25
0
25
50
75
100
125
Qg - Total Gate Charge (nC)
TJ - Junction Temperature (°C)
Gate Charge
On-Resistance vs. Junction Temperature
Document Number: 68841
S09-0863-Rev. C, 18-May-09
150
www.vishay.com
3
New Product
Si4435DDY
Vishay Siliconix
TYPICAL CHARACTERISTICS 25 °C, unless otherwise noted
100
0.06
ID = 9.1 A
0.05
R DS(on) - On-Resistance (Ω)
IS - Source Current (A)
10
TJ = 150 °C
TJ = 25 °C
1
0.1
TJ = - 50 °C
0.01
0.001
0.0
0.04
TJ = 125 °C
0.03
0.02
TJ = 25 °C
0.01
0
0.2
0.4
0.6
0.8
1.0
1.2
0
1
2
3
4
5
6
7
8
9
VSD - Source-to-Drain Voltage (V)
VGS - Gate-to-Source Voltage (V)
Source-Drain Diode Forward Voltage
On-Resistance vs. Gate-to-Source Voltage
10
100
0.6
80
ID = 250 µA
0.2
60
Power (W)
VGS(th) Variance (V)
0.4
ID = 1 mA
40
0.0
20
- 0.2
- 50
- 25
0
25
50
75
100
125
0
0.001
150
0.01
0.1
1
10
Time (s)
TJ - Temperature (°C)
Threshold Voltage
100
Single Pulse Power, Junction-to-Ambient
Limited by RDS(on)*
100 µs
I D - Drain Current (A)
10
1 ms
10 ms
1
100 ms
1s
10 s
100 s, DC
0.1
TA = 25 °C
Single Pulse
BVDSS Limited
0.01
0.1
1
10
100
VDS - Drain-to-Source Voltage (V)
* VGS > minimum VGS at which RDS(on) is specified
Safe Operating Area
www.vishay.com
4
Document Number: 68841
S09-0863-Rev. C, 18-May-09
New Product
Si4435DDY
Vishay Siliconix
TYPICAL CHARACTERISTICS 25 °C, unless otherwise noted
15
ID - Drain Current (A)
12
9
6
3
0
0
25
50
75
100
125
150
TC - Case Temperature (°C)
6.0
2.0
4.8
1.6
3.6
1.2
Power (W)
Power (W)
Current Derating*
2.4
0.8
0.4
1.2
0.0
0.0
0
25
50
75
100
125
150
0
25
50
75
100
125
TC - Case Temperature (°C)
TA - Ambient Temperature (°C)
Power, Junction-to-Foot
Power Derating, Junction-to-Ambient
150
* The power dissipation PD is based on TJ(max) = 150 °C, using junction-to-case thermal resistance, and is more useful in settling the upper
dissipation limit for cases where additional heatsinking is used. It is used to determine the current rating, when this rating falls below the package
limit.
Document Number: 68841
S09-0863-Rev. C, 18-May-09
www.vishay.com
5
New Product
Si4435DDY
Vishay Siliconix
TYPICAL CHARACTERISTICS 25 °C, unless otherwise noted
1
Normalized Effective Transient
Thermal Impedance
Duty Cycle = 0.5
0.2
0.1
Notes:
0.1
PDM
0.05
t1
t2
1. Duty Cycle, D =
0.02
t1
t2
2. Per Unit Base = RthJA = 85 °C/W
3. TJM - TA = PDM Z thJA(t)
Single Pulse
4. Surface Mounted
0.01
10-4
10-3
10 -2
10 -1
1
10
100
1000
Square Wave Pulse Duration (s)
Normalized Thermal Transient Impedance, Junction-to-Ambient
Normalized Effective Transient
Thermal Impedance
1
Duty Cycle = 0.5
0.2
0.1
0.1
0.05
0.02
Single Pulse
0.01
10-4
10-3
10-2
10-1
Square Wave Pulse Duration (s)
1
10
Normalized Thermal Transient Impedance, Junction-to-Foot
Vishay Siliconix maintains worldwide manufacturing capability. Products may be manufactured at one of several qualified locations. Reliability data for Silicon
Technology and Package Reliability represent a composite of all qualified locations. For related documents such as package/tape drawings, part marking, and
reliability data, see www.vishay.com/ppg?68841.
www.vishay.com
6
Document Number: 68841
S09-0863-Rev. C, 18-May-09
Package Information
Vishay Siliconix
SOIC (NARROW): 8-LEAD
JEDEC Part Number: MS-012
8
6
7
5
E
1
3
2
H
4
S
h x 45
D
C
0.25 mm (Gage Plane)
A
e
B
All Leads
q
A1
L
0.004"
MILLIMETERS
INCHES
DIM
Min
Max
Min
Max
A
1.35
1.75
0.053
0.069
A1
0.10
0.20
0.004
0.008
B
0.35
0.51
0.014
0.020
C
0.19
0.25
0.0075
0.010
D
4.80
5.00
0.189
0.196
E
3.80
4.00
0.150
e
0.101 mm
1.27 BSC
0.157
0.050 BSC
H
5.80
6.20
0.228
0.244
h
0.25
0.50
0.010
0.020
L
0.50
0.93
0.020
0.037
q
0°
8°
0°
8°
S
0.44
0.64
0.018
0.026
ECN: C-06527-Rev. I, 11-Sep-06
DWG: 5498
Document Number: 71192
11-Sep-06
www.vishay.com
1
Application Note 826
Vishay Siliconix
RECOMMENDED MINIMUM PADS FOR SO-8
0.172
(4.369)
0.028
0.022
0.050
(0.559)
(1.270)
0.152
(3.861)
0.047
(1.194)
0.246
(6.248)
(0.711)
Recommended Minimum Pads
Dimensions in Inches/(mm)
Return to Index
APPLICATION NOTE
Return to Index
www.vishay.com
22
Document Number: 72606
Revision: 21-Jan-08
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000