PDF PBC1004PFC Data Sheet

Data Sheet
Power Bank PB1004PFC
AC/DC Power Supply
4 Outputs, 1000W
Low-Profile 1.75" (1U)
SEMI F47 Compliant
All specifications are at nominal input, full load, 25°C, unless otherwise noted.
Input
Input Voltage (nominal)
Input Voltage Range
Input Frequency
Inrush Current (cold start.)
Input Fuse (internal)
Power Factor (minimum)
Input Harmonics
Line dropout
115/230Vac
90-264Vac
47-63 Hz
<20 A at 115Vac, <40A at 230Vac
20A
0.95
EN 61000-3-2 Compliant
SEMI F47 Compliant when operated at 180-264Vac
Output
Output
Maximum Output Current (Connector Limit)
Output Voltage (Factory configurable)
Module Size
Output Voltage Setpoint (50% load)
Load Regulation, No load to full load (max)
Line Regulation, Low Line to High Line (max)
Remote Sense
Output Trim
A
B
C
80A
80A
1.8 to 52 V
1.8 to 52 V
Maxi
Mini
Micro
±1.2%
±1.2%
±1.2%
±0.2%
±0.2%
±0.5%
±0.2%
±0.2%
±0.5%
Yes
Yes
No
Yes
Yes
Output Ripple and Noise
Yes
D
40A
1.8 to 52 V
Micro
±1.2%
±0.5%
±0.5%
No
Yes
See individual Vicor module specifications.
Maximum Output Power (Individual output)
Maximum Output Power (Total all outputs)
600W
300W
150W
150 W
1000W, See output power derating chart on page 2.
Environmental
Operating Temperature Range
(see output power derating on page 2)
Thermal Shutdown
Storage Temperature Range
Relative Humidity
-20°C to 50°C
100°C internal module shutdown, non-latching
-40°C to 70°C
5% -95% non-condensing
Safety
cTUVus, CE
EN 60950
3000Vrms
1500Vrms
250Vrms
Agency Approvals
Safety Standard Compliance
Isolation, Primary-to-Secondary
Isolation, Primary-Earth
Isolation, Secondary-Earth
Vicor Custom Power - Northwest
(503)-652-6161
www.npi-inc.com
Document No. 7663 Rev. E
Print Date: 2014-05-19
Page 1 of 3
PB1004PFC
Output Power Derating
1100
1000
Output Power ( W )
900
800
700
600
500
400
300
200
100
0
80
130
180
230
280
AC Input Voltage ( Vac )
At 25°C. Output power may be further limited at higher ambient temperature. Contact factory for details.
EMI and EMC
EN55022 Class A (150kHz-30MHz)
Conducted Noise
Mechanical
Dimensions
(Approximate. See Mechanical Drawing for details.)
10.28" x 8.08" x 1.74"
Universal Mounting Brackets
Short Front Panel or Full 19" Front Panel
Internal Fans
5.5 lb. (2.5 kg)
Mounting Options (contact factory for details)
Cooling
Weight (Typical, depends on configuration)
Input Power Connections
Connector
IEC320
Details
Standard pin configuration
Optional Cord Retainer
Front Panel LEDs
Long Wire Bail
Short Wire Bail
NPI P/N 4340, Qualtek #730B-00/05
NPI P/N 4013, Qualtek #730B-00/00
One Red/Green LED for each main output
Color
Signal Description
Green
Output OK
Red
Output Not OK
Vicor Custom Power - Northwest
(503)-652-6161
www.npi-inc.com
Document No. 7663 Rev. E
Print Date: 2014-05-19
Page 2 of 3
Details
Corresponding output voltage is correct, i.e. sufficiently high if
output is populated or zero if output is not populated.
Corresponding output voltage is too low.
PB1004PFC
Output Power Connections for Channels A and B
Details
Molex Minifit Sr. Connector
(Option -M)
(Molex 42820-4212)
Pin
Signal Description
1
+
Positive Terminal, 49A max
2
+
Positive Terminal, 49A max
3
-
Negative Terminal, 49A max
4
-
Negative Terminal, 49A max
Straight Bus Bar
(Option -B)
Right-Angle Bus Bar
(Option -R)
Positive Terminal, 1/4"
hole, 100A max
Positive Terminal,
Tapped 1/4-20 hole,
100A max
Negative Terminal,
1/4" hole, 100A max
Negative Terminal,
Tapped 1/4-20 hole,
100A max
Output Power Connections for Channels C and D (Molex 42820-4212)
Pin
1
2
3
4
Signal Description
Details
Output D, Positive Terminal, 49A max
+
+
-
Output D, Negative Terminal, 49A max
Output C, Positive Terminal, 49A max
Output C, Negative Terminal, 49A max
Trim/Remote Sense Connections for Channels A and B (AMP 102617-1)
(Remote sense is active only if Maxi or Mini size module is installed.)
Pin
Signal Description
1
+Sense B
Trim B
- Sense B
2
3
4
5
6
+Sense A
Trim A
- Sense A
I/O Connections
(Molex 70555-0038)
Pin
1
2
3
4
Details
Positive Sense Connection
(Internally connected to positive output through 50 Ω resistor fused by 0.17A Polyfuse)
Connect this pin with a resistor to Pin 1 for trim up, or to Pin 3 for trim down.
Negative Sense Connection
(Internally connected to negative output through 50 Ω resistor)
Positive Sense Connection
(Internally connected to positive output through 50 Ω resistor fused by 0.17A Polyfuse)
Connect this pin with a resistor to Pin 1 for trim up, or to Pin 3 for trim down.
Negative Sense Connection
(Internally connected to negative output through 50 Ω resistor)
Note: All control signals are isolated; Input - 3,000 Vrms; Output - 250 Vrms; Chassis - 250 Vrms
Signal Description
12V Aux
Pgood
Inhibit
Control Return
Details
12V/100mA Auxiliary Stand-By Output
Open Collector, 40V/5mA, Active Low = Power Good
Connect to Pin 4 (Control Return) to inhibit all outputs, except 12V Aux.
Reference for all signals on I/O connector. Return for 12V Aux.
Information furnished by NORTHWEST POWER is believed to be accurate and reliable. However, no responsibility is assumed by NORTHWEST
POWER or Vicor for its use. No license is granted by implication or otherwise under any patent or patent rights of NORTHWEST POWER or Vicor.
NORTHWEST POWER products are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result
in injury or death. All sales are subject to NORTHWEST POWER 's Terms and Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.
Vicor Custom Power - Northwest
♦ 4211 SE International Way, Suite F♦ Milwaukie, OR, USA
Tel: 503-652-6161 ♦ Fax: 503-652-6868 ♦ www.npi-inc.com
Vicor Custom Power - Northwest
(503)-652-6161
www.npi-inc.com
Document No. 7663 Rev. E
Print Date: 2014-05-19
Page 3 of 3
PB1004PFC