Data Sheet Power Bank PB1004PFC AC/DC Power Supply 4 Outputs, 1000W Low-Profile 1.75" (1U) SEMI F47 Compliant All specifications are at nominal input, full load, 25°C, unless otherwise noted. Input Input Voltage (nominal) Input Voltage Range Input Frequency Inrush Current (cold start.) Input Fuse (internal) Power Factor (minimum) Input Harmonics Line dropout 115/230Vac 90-264Vac 47-63 Hz <20 A at 115Vac, <40A at 230Vac 20A 0.95 EN 61000-3-2 Compliant SEMI F47 Compliant when operated at 180-264Vac Output Output Maximum Output Current (Connector Limit) Output Voltage (Factory configurable) Module Size Output Voltage Setpoint (50% load) Load Regulation, No load to full load (max) Line Regulation, Low Line to High Line (max) Remote Sense Output Trim A B C 80A 80A 1.8 to 52 V 1.8 to 52 V Maxi Mini Micro ±1.2% ±1.2% ±1.2% ±0.2% ±0.2% ±0.5% ±0.2% ±0.2% ±0.5% Yes Yes No Yes Yes Output Ripple and Noise Yes D 40A 1.8 to 52 V Micro ±1.2% ±0.5% ±0.5% No Yes See individual Vicor module specifications. Maximum Output Power (Individual output) Maximum Output Power (Total all outputs) 600W 300W 150W 150 W 1000W, See output power derating chart on page 2. Environmental Operating Temperature Range (see output power derating on page 2) Thermal Shutdown Storage Temperature Range Relative Humidity -20°C to 50°C 100°C internal module shutdown, non-latching -40°C to 70°C 5% -95% non-condensing Safety cTUVus, CE EN 60950 3000Vrms 1500Vrms 250Vrms Agency Approvals Safety Standard Compliance Isolation, Primary-to-Secondary Isolation, Primary-Earth Isolation, Secondary-Earth Vicor Custom Power - Northwest (503)-652-6161 www.npi-inc.com Document No. 7663 Rev. E Print Date: 2014-05-19 Page 1 of 3 PB1004PFC Output Power Derating 1100 1000 Output Power ( W ) 900 800 700 600 500 400 300 200 100 0 80 130 180 230 280 AC Input Voltage ( Vac ) At 25°C. Output power may be further limited at higher ambient temperature. Contact factory for details. EMI and EMC EN55022 Class A (150kHz-30MHz) Conducted Noise Mechanical Dimensions (Approximate. See Mechanical Drawing for details.) 10.28" x 8.08" x 1.74" Universal Mounting Brackets Short Front Panel or Full 19" Front Panel Internal Fans 5.5 lb. (2.5 kg) Mounting Options (contact factory for details) Cooling Weight (Typical, depends on configuration) Input Power Connections Connector IEC320 Details Standard pin configuration Optional Cord Retainer Front Panel LEDs Long Wire Bail Short Wire Bail NPI P/N 4340, Qualtek #730B-00/05 NPI P/N 4013, Qualtek #730B-00/00 One Red/Green LED for each main output Color Signal Description Green Output OK Red Output Not OK Vicor Custom Power - Northwest (503)-652-6161 www.npi-inc.com Document No. 7663 Rev. E Print Date: 2014-05-19 Page 2 of 3 Details Corresponding output voltage is correct, i.e. sufficiently high if output is populated or zero if output is not populated. Corresponding output voltage is too low. PB1004PFC Output Power Connections for Channels A and B Details Molex Minifit Sr. Connector (Option -M) (Molex 42820-4212) Pin Signal Description 1 + Positive Terminal, 49A max 2 + Positive Terminal, 49A max 3 - Negative Terminal, 49A max 4 - Negative Terminal, 49A max Straight Bus Bar (Option -B) Right-Angle Bus Bar (Option -R) Positive Terminal, 1/4" hole, 100A max Positive Terminal, Tapped 1/4-20 hole, 100A max Negative Terminal, 1/4" hole, 100A max Negative Terminal, Tapped 1/4-20 hole, 100A max Output Power Connections for Channels C and D (Molex 42820-4212) Pin 1 2 3 4 Signal Description Details Output D, Positive Terminal, 49A max + + - Output D, Negative Terminal, 49A max Output C, Positive Terminal, 49A max Output C, Negative Terminal, 49A max Trim/Remote Sense Connections for Channels A and B (AMP 102617-1) (Remote sense is active only if Maxi or Mini size module is installed.) Pin Signal Description 1 +Sense B Trim B - Sense B 2 3 4 5 6 +Sense A Trim A - Sense A I/O Connections (Molex 70555-0038) Pin 1 2 3 4 Details Positive Sense Connection (Internally connected to positive output through 50 Ω resistor fused by 0.17A Polyfuse) Connect this pin with a resistor to Pin 1 for trim up, or to Pin 3 for trim down. Negative Sense Connection (Internally connected to negative output through 50 Ω resistor) Positive Sense Connection (Internally connected to positive output through 50 Ω resistor fused by 0.17A Polyfuse) Connect this pin with a resistor to Pin 1 for trim up, or to Pin 3 for trim down. Negative Sense Connection (Internally connected to negative output through 50 Ω resistor) Note: All control signals are isolated; Input - 3,000 Vrms; Output - 250 Vrms; Chassis - 250 Vrms Signal Description 12V Aux Pgood Inhibit Control Return Details 12V/100mA Auxiliary Stand-By Output Open Collector, 40V/5mA, Active Low = Power Good Connect to Pin 4 (Control Return) to inhibit all outputs, except 12V Aux. Reference for all signals on I/O connector. Return for 12V Aux. Information furnished by NORTHWEST POWER is believed to be accurate and reliable. However, no responsibility is assumed by NORTHWEST POWER or Vicor for its use. No license is granted by implication or otherwise under any patent or patent rights of NORTHWEST POWER or Vicor. NORTHWEST POWER products are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to NORTHWEST POWER 's Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice. Vicor Custom Power - Northwest ♦ 4211 SE International Way, Suite F♦ Milwaukie, OR, USA Tel: 503-652-6161 ♦ Fax: 503-652-6868 ♦ www.npi-inc.com Vicor Custom Power - Northwest (503)-652-6161 www.npi-inc.com Document No. 7663 Rev. E Print Date: 2014-05-19 Page 3 of 3 PB1004PFC