Data Sheet Power Bank PB3606PFC AC/DC Power Supply 1phase or 3phase AC input 6 Main Outputs, 3,600W Low-Profile 1.75" (1U) Drawing for reference only. Actual front panel details may be different. All specifications are at nominal input, full load, 25°C, unless otherwise noted. Input Input Configuration 1-phase 85-264VAC L-L/N 47-440Hz <60 A Input Voltage Input Frequency Inrush Current, 264 VAC peak, cold start. Power Factor (minimum); 47-63Hz 0.95 25A Input Connector Maximum Current per Pin 3-phase 85-264VAC L-L 47-440Hz <60 A 0.95 Phases not balanced unless all channels are configured for load sharing. 25A Total Output Power Single Phase at 115VAC Single Phase at 230VAC 3 Phase delta at 200VAC Line-Line 2,300W 3,600W 3,600W Output (Each Output, typical) Output Voltage (Factory configurable) Output Voltage Setpoint (50% load) Load Regulation, No load to full load (max.) Line Regulation, Low Line to High Line (max.) Remote Sense 1.8V to 60 V ±1.2% ±0.25% ±0.2% Yes Output Trim Yes Output Ripple and Noise 1% (See Vicor module datasheet for details.) Maximum Output Power 600W Maximum Output Current 80A Molex: Screw terminal: Maximum Output Current Pin Rating 49A per pin 30A per terminal Safety Agency Approvals (Pending, Single-Phase Operation) Safety Standard Compliance Isolation, Primary-to-Secondary Isolation, Primary-Earth Isolation, Secondary-Earth cTUVus, CE EN60950 3,000 Vrms 1,500 Vrms 250 Vrms EMI and EMC Conducted Noise Input Transient Document No. 8564 Rev B EN55022 Class A (150kHz-30MHz) EN61000-4-5, 2kV Common Mode, 1kV Differential Mode PB3606PFC Page 1 of 3 Print Date: 2014-05-19 Input Connector Positronic PLB3W3M4BN0A1/AA PIN# 3 Phase Configuration 1 Phase Configuration Description Description 1 (Bottom) Line 1 input Line/Neutral 2 (Top) Line 2 input Line/Neutral 3 (Middle) Line 3 input N/C Chassis Screw Earth Connection to Power Supply Chassis Output Connections Layout Channel Output Signal C B 2 - - 1 + + - - A 2 + + - - 1 + + - - 2 + + - - I/O Connector (Each Channel): Molex 43045-1600 Microfit 16 Pin, right angle Pin header Signal Sense 2 Trim 2 Sense 2 Parallel Parallel Pgood 2 (+) Bus 1 Bus 1 (-) RTN 1 + + - - + + Inhibit* Secondary 12V Vcc Pin# 8 7 6 5 4 3 2 1 Pin# 16 15 14 13 12 11 10 9 Sense 1 Trim 1 Sense 1 Parallel Bus 2 RTN Parallel Bus 2 Pgood 1 PFW* Pgood 2 Signal (-) (+) RTN Front Panel Pgood Indicators: One Green LED for each output LED is ON if the corresponding output voltage is: (a) present if output is populated or (b) zero if output is not populated. Document No. 8564 Rev B PB3606PFC Page 2 of 3 Print Date: 2014-05-19 Environmental Minimum Operating Temperature Maximum Operating Temperature Storage Temperature Range Relative Humidity -20°C +50°C -40°C to 85°C 5% -95% non-condensing Mechanical 17"W x 18.55"D x 1.75"H Dimensions (*) Mounting Brackets 19" Front Panel Mounting Options (*) Cooling Internal Fans, two per channel Weight (Typical, depends on configuration) 14 lb. (6.4 kg) (*) Contact factory or visit www.npi-inc.com for details. Information furnished by NORTHWEST POWER is believed to be accurate and reliable. However, no responsibility is assumed by NORTHWEST POWER or Vicor for its use. No license is granted by implication or otherwise under any patent or patent rights of NORTHWEST POWER or Vicor. NORTHWEST POWER products are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to NORTHWEST POWER 's Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice. Northwest Power, Inc. ♦ 4211 SE International Way, Suite F♦ Milwaukie, OR, USA Tel: 503-652-6161 ♦ Fax: 503-652-6868 ♦ www.npi-inc.com Document No. 8564 Rev B PB3606PFC Page 3 of 3 Print Date: 2014-05-19