mil38510ss190

INCH-POUND
MIL-M-38510/190D
12 October 2005
SUPERSEDING
MIL-M-38510/190C
22 October 1986
MILITARY SPECIFICATION
MICROCIRCUITS, LINEAR, CMOS/ANALOG MULTIPLEXERS/DEMULTIPLEXERS WITH OVERVOLTAGE
PROTECTION, MONOLITHIC SILICON, POSITIVE LOGIC
This specification is approved for use by all Departments and Agencies of the Department of Defense.
Inactive for new design as of 10 July 1995
The requirements for acquiring the product herein shall consist of this specification sheet and MIL-PRF-38535
1. SCOPE
1.1 Scope. This specification covers the detail requirements for monolithic silicon, CMOS/Analog logic
microcircuits. Two product assurance classes and a choice of case outlines and lead finishes are provided and are
reflected in the complete part number. For this product, the requirements of MIL-M-38510 have been superseded by
MIL-PRF-38535, (see 6.4)
1.2 Part or Identifying Number (PIN). The PIN is in accordance with MIL-PRF-38535, and as specified herein.
1.2.1 Device types. The device types are as follows:
Device type
Circuit
01
02
03
04
05
06
07
08
Single 16-channel MUX/DEMUX
Single 16-channel MUX/DEMUX with overvoltage protection
Differential 8-channel MUX/DEMUX
Differential 8-channel MUX/DEMUX with overvoltage protection
Single 8-channel MUX/DEMUX with overvoltage protection
Differential 4-channel MUX/DEMUX with overvoltage protection
Single 8-channel MUX/DEMUX
Differential 4-channel MUX/DEMUX
1.2.2 Device class. The device class is the product assurance level as defined in MIL-PRF-38535.
1.2.3 Case outline. The case outlines are as designated in MIL-STD-1835 and as follows:
Outline letter
E
X
Descriptive designator
GDIP1-T16 or CDIP2-T16
See figure 4
Terminals
16
28
Package style
Dual-in-line
Dual-in-line
Comments, suggestions, or questions on this document should be addressed to: Commander, Defense
Supply Center Columbus, ATTN: DSCC-VAS, 3990 East Broad St., Columbus, OH 43218-3990, or email
mailto:[email protected] . Since contact information can change, you may want to verify the currency of
this address information using the ASSIST Online database at http://assist.daps.dla.mil .
AMSC N/A
FSC 5962
MIL-M-38510/190D
1.3 Absolute maximum ratings.
Supply voltage between V+ and V-:
Device types 02, 04, 05, and 06 ...........................................................
Device types 01, 03, 07, and 08 ...........................................................
V+ to ground:
Device types 02, 04, 05, and 06 ..........................................................
Device types 01, 03, 07, and 08 ..........................................................
Digital input voltage:
Device types 02, 04, 05, and 06 ..........................................................
Device types 01, 03, 07, and 08 ..........................................................
Analog input:
Device types 02, 04, 05, and 06 ..........................................................
Device types 01, 03, 07, and 08 ..........................................................
Storage temperature .................................................................................
Lead temperature (soldering, 10 seconds) ................................................
Junction temperature (TJ)...........................................................................
+40 V
+32 V
+20 V
+16 V
((V-) – 4 V) ≤ VD ≤ ((V+) + 4 V)
-0.3 V ≤ VD ≤ (V+)
((V-) – 20 V ≤VA ≤ ((V+) + 20 V)
(V-) ≤ VA ≤ (V+)
-65°C to +150°C
300°C
+175°C
1.4 Recommended operating conditions.
V+ ............................................................................................................................
V- ............................................................................................................................
VREF .........................................................................................................................
VIL (max) ..................................................................................................................
VIH (min):
Device types 01, 03, 07, and 08 ........................................................................
Device types 02, 04, 05, and 06 ........................................................................
VEN:
Device types 02, 04, 05, and 06 ........................................................................
Device types 01, 03, 07, and 08 ........................................................................
Ambient operating temeperature range (TA) .............................................................
+15 V
-15 V
Open
0.8 V
2.4 V
4.0 V
4.0 V
4.5 V
-55°C to +125°C
1.5 Power and thermal characteristics.
Case outline
Maximum allowable power dissipation 1/
E
X
400 mW @ TA = 125°C
400 mW @ TA = 125°C
Maximum θJC 2/
50°C/W
51°C/W
Maximum θJA
125°C/W
125°C/W
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This
section does not include documents cited in other sections of this specification or recommended for additional
information or as examples. While every effort has been made to ensure the completeness of this list, document
users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this
specification, whether or not they are listed.
1/ All leads welded or soldered to PC board.
2/ Applies only when TA ≥ 75°C.
2
MIL-M-38510/190D
2.2 Government documents.
2.2.1 Specifications and Standards. The following specifications and standards form a part of this specification to
the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATIONS
MIL-PRF-38535
- Integrated Circuits (Microcircuits) Manufacturing, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883
MIL-STD-1835
- Test Method Standard for Microelectronics.
- Interface Standard Electronic Component Case Outlines.
(Copies of these documents are available online at http://assist.daps.dla.mil/quicksearch/ or
http://assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D,
Philadelphia, PA 19111-5094.
2.3 Order of precedence. In the event of a conflict between the text of this document and the references cited
herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws
and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Qualification. Microcircuits furnished under this specification shall be products that are manufactured by a
manufacturer authorized by the qualifying activity for listing on the applicable qualified manufacturers list before
contract award (see 4.3 and 6.3).
3.2 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535 and as
specified herein or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the
QM plan shall not affect the form, fit, or function as described herein.
3.3 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as
specified in MIL-PRF-38535 and herein. Although eutectic die bonding is preferred, epoxy die bonding may be
performed. However, the resin used shall be Dupont 5504A conductive silver paste, or equivalent, which is cured at
200°C ±10°C for a minimum of 2 hours. The use of equivalent epoxies or cure cycles shall be approved by the
qualifying activity. Equivalency shall be demonstrated in data submitted to the qualifying acivity for verification.
3.3.1 Terminal connections. The terminal connections shall be as specified on figure 1.
3.3.2 Functional diagrams. The functional diagrams shall be as specified on figure 2.
3.3.3 Truth tables. The truth tables shall be as specified on figure 3.
3.3.4 Case outline. The case outline shall be as specified in 1.2.3 and figure 4.
3.3.5 Schematic circuits. The schematic circuits shall be maintained by the manufacturer and made available to
the qualifying activity and the preparing activity (DSCC-VA) upon request.
3.4 Lead material and finish. The lead material and finish shall be in accordance with MIL-PRF-38535 (see 6.6).
3.5 Electrical performance characteristics. The electrical performance characteristics are as specified in table I,
and apply over the full recommended ambient operating temperature range, unless otherwise specified.
3.6 Electrical test requirements. Electrical test requirements for each device class shall be the subgroups
specified in table II. The electrical tests for each subgroup are described in table III.
3.7 Marking. Marking shall be in accordance with MIL-PRF-38535.
3.8 Microcircuit group assignment. The devices covered by this specification shall be in microcircuit group number
82 (see MIL-PRF-38535, appendix A).
3
MIL-M-38510/190D
TABLE I. Electrical performance characteristics.
Test
Symbol
Conditions 1/ 2/
V- = -15 V, V+ = +15 V,
VEN = 4.5 V, GND = 0 V,
-55°C ≤ TA ≤ +125°C
unless otherwise specified
Limits
Device
type
Min
Unit
Max
Positive input clamping
voltage
VIC(POS)
TA = 25°C, V+ = V- = 0 V,
IIN = 1 mA
02, 04,
05, 06
1.5
V dc
Negative input clamping
voltage
VIC(NEG)
TA = 25°C, V+ = V- = 0 V,
IIN = -1 mA
02, 04,
05, 06
-1.5
Input leakage current 3/
IIH
Measure address inputs
sequentially, connect all
unused address inputs to
GND
All
-0.1
+1.0
µA
Input leakage current 3/
IIL
Measure address inputs
sequentially, connect all
unused address inputs to
5V
All
-1.0
+0.1
µA
Leakage current into the
source terminal of an “OFF”
switch
IS(OFF)
VS = 10 V, VEN = 0.8 V,
All unused sources = -10 V,
All
-1
1
nA
-50
50
-1
1
-50
50
01, 02
-20
20
03, 04,
05, 06,
07, 08
-10
10
01, 02
-500
500
03, 04,
05, 07
-250
250
06, 08
-125
125
V dc
TA = 25°C
VS = 10 V, VEN = 0.8 V,
All unused sources = -10 V,
-55°C ≤ TA ≤ 125°C
VS = -10 V, VEN = 0.8 V,
All unused sources= +10 V,
TA = 25°C
VS = -10 V, VEN = 0.8 V,
All unused sources= +10 V,
-55°C ≤ TA ≤ 125°C
Leakage current into the
drain terminal of an “OFF”
switch
ID+(OFF)
VD = 10 V, VEN = 0.8 V,
All unused sources = -10 V,
TA = 25°C
VD = 10 V, VEN = 0.8 V,
All unused sources = -10 V,
-55°C ≤ TA ≤ 125°C
See footnotes at end of table.
4
nA
MIL-M-38510/190D
TABLE I. Electrical performance characteristics – Continued.
Test
Symbol
Conditions 1/ 2/
V- = -15 V, V+ = +15 V,
VEN = 4.5 V, GND = 0 V,
-55°C ≤ TA ≤ +125°C
unless otherwise specified
Limits
Device
type
Min
Leakage current into the
drain terminal of an “OFF”
switch
ID-(OFF)
VD = 10 V, VEN = 0.8 V,
All unused sources = -10 V,
Unit
Max
01, 02
-20
20
03, 04,
05, 06,
07, 08
-10
10
01, 02
-500
500
03, 04,
05, 07
06, 08
-250
250
-125
125
01, 02
-20
20
03, 04,
05, 06,
07, 08
-10
10
01, 02
-500
500
03, 04,
05, 07
-250
250
06, 08
-125
125
01, 02
-20
20
03, 04,
05, 06,
07, 08
-10
10
01, 02
-500
500
03, 04,
05, 07
-250
250
06, 08
-125
125
nA
TA = 25°C
VD = 10 V, VEN = 0.8 V,
All unused sources = -10 V,
-55°C ≤ TA ≤ 125°C
Leakage current from an
“ON” driver into the switch
(drain)
ID(ON)
VS = 10 V, VD = 10 V,
Connect all unused sources
to -10 V, TA = 25°C
VS = 10 V, VD = 10 V,
Connect all unused sources
to -10 V,
-55°C ≤ TA ≤ 125°C
VS = 10 V, VD = -10 V,
Connect all unused sources
to -10 V, TA = 25°C
VS = 10 V, VD = -10 V,
Connect all unused sources
to -10 V,
-55°C ≤ TA ≤ 125°C
See footnotes at end of table.
5
nA
MIL-M-38510/190D
TABLE I. Electrical performance characteristics – Continued.
Test
Symbol
Conditions 1/ 2/
V- = -15 V, V+ = +15 V,
VEN = 4.5 V, GND = 0 V,
-55°C ≤ TA ≤ +125°C
unless otherwise specified
Limits
Device
type
Min
Overvoltage protected,
leakage current into the
drain terminal of an
“OFF” switch
ID(OFF)
overvoltage
VS = 33 V, VD = 0 V,
VEN = 0.8 V
02, 04,
05, 06
VS = -33 V, VD = 0 V,
VEN = 0.8 V
Positive supply current
I(+)
VA = 0 V, VEN = 5 V
Standby positive supply
current
Standby negative
supply current
I(-)
I+SBY
I-SBY
VA = 0 V, VEN = 5 V
VA = 0 V, VEN = 0 V
VA = 0 V, VEN = 0 V
Max
-2.0
2.0
-2.0
2.0
01, 03
14
02, 04,
05, 06
2.0
07, 08
Negative supply current
Unit
µA
mA
12
01, 03
-14
02, 04,
05, 06
-1
07, 08
-12
mA
01, 03
3.0
02, 04,
05, 06
2.0
07, 08
3.5
01, 03
-4.0
02, 04,
05, 06
-1.0
07, 08
-3.5
mA
mA
Capacitance: Address
CA
V+ = V- = 0 V, TA = 25°C,
f = 1 MHz
All
10
pF
Capacitance: Enable
CEN
V+ = V- = 0 V, TA = 25°C,
f = 1 MHz
All
10
pF
Capacitance: Output
switch
COS
V+ = V- = 0 V,
See table III
01
90
pF
02
85
03, 04
05, 07
50
45
Capacitance: Input
switch
CIS
V+ = V- = 0 V,
See table III
See footnotes at end of table.
6
06, 08
25
All
10
pF
MIL-M-38510/190D
TABLE I. Electrical performance characteristics – Continued.
Test
Symbol
Conditions 1/ 2/
V- = -15 V, V+ = +15 V,
VEN = 4.5 V, GND = 0 V,
-55°C ≤ TA ≤ +125°C
unless otherwise specified
Device
type
Limits
Min
Switch “ON” resistance
RDS1
VS = 10 V, ID = 1 mA,
01, 03
TA = 25°C, TA = -55°C
VS = 10 V, ID = 1 mA,
Unit
Max
600
Ω
700
TA = 125°C
VS = 10 V, ID = 100 µA,
02, 04
1,500
TA = 25°C, TA = -55°C
2,000
VS = 10 V, ID = 100 µA,
TA = 125°C
VS = 10 V, ID = 100 µA,
05, 06
1,500
TA = 25°C, TA = -55°C
1,800
VS = 10 V, ID = 100 µA,
TA = 125°C
VS = 10 V, ID = 1 mA,
07, 08
400
TA = 25°C, TA = -55°C
VS = 10 V, ID = 1 mA,
500
TA = 125°C
Switch “ON” resistance
RDS1
VS = -10 V, ID = -1 mA,
01, 03
600
TA = 25°C, TA = -55°C
700
VS = -10 V, ID = -1 mA,
TA = 125°C
VS = -10 V, ID = -100 µA,
02, 04
1,500
TA = 25°C, TA = -55°C
2,000
VS = -10 V, ID = -100 µA,
TA = 125°C
VS = -10 V, ID = -100 µA,
05, 06
1,500
TA = 25°C, TA = -55°C
1,800
VS = -10 V, ID = -100 µA,
TA = 125°C
VS = -10 V, ID = -1 mA,
07, 08
400
TA = 25°C, TA = -55°C
VS = -10 V, ID = -1 mA,
TA = 125°C
See footnotes at end of table.
7
500
Ω
MIL-M-38510/190D
TABLE I. Electrical performance characteristics – Continued.
Test
Symbol
Conditions 1/ 2/
V- = -15 V, V+ = +15 V,
VEN = 4.5 V, GND = 0 V,
-55°C ≤ TA ≤ +125°C
unless otherwise specified
Limits
Device
type
Min
Switch “ON” resistance
RDS2
Unit
Max
V+ = 10 V, V- = -10 V,
VS = 7.5 V, ID = 1 mA
01, 03,
07, 08
1,000
V+ = 10 V, V- = -10 V,
02, 04
2,400
05, 06
2,200
V+ = 10 V, V- = -10 V,
VS = -7.5 V, ID = -1 mA
01, 03,
07, 08
1,000
V+ = 10 V, V- = -10 V,
02, 04
2,400
05, 06
2,200
Ω
VS = 7.5 V, ID = 100 µA
VS = -7.5 V, ID = -100 µA
Single channel isolation
VISO
f = 200 kHz, VGEN = 1 VP-P,
see figure 15
All
50
dB
Crosstalk between
channels
VCT
F = 200 kHz, VGEN = 1 VP-P,
see figure 16
All
50
dB
Charge transfer error
VCTE
VS = GND, see figure 17
All
Break-before-make time
delay
tD
See figure 14, TA = 25°C
All
Propagation delay
times: Address inputs
to I/O channels
tON(A)
tOFF(A)
RL = 1 kΩ, CL = 100 pF,
see figures 6, 8, 10, and
12, TA = 25°C, TA = -55°C
All
tON(EN)
tOFF(EN)
RL = 1 kΩ, CL = 100 pF,
see figures 7, 9, 11, and
13, TA = 25°C, TA = -55°C
RL = 1 kΩ, CL = 100 pF,
see figures 7, 9, 11, and
13, TA = 125°C
5
mV
ns
1,000
ns
1,500
RL = 1 kΩ, CL = 100 pF,
see figures 6, 8, 10, and
12, TA = 125°C
Enable to I/O
10
All
1,000
ns
1,500
1/ Current flowing in either direction between any associated input and output terminals of the switch shall be 30 mA
maximum.
2/ Input = source; Output = drain.
3/ Input current of one input node.
8
MIL-M-38510/190D
4. VERIFICATION.
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535 or
as modified in the device manufacturer’s Quality Management (QM) plan. The modification in the QM plan shall not
affect the form, fit, or function as function as described herein.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38535, and shall be conducted on all devices prior
to qualification and quality conformance inspection. The following additional criteria shall apply:
a.
The burn-in test duration, test condition, and test temperature, or approved alternatives shall be as specified
in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be
maintained under document control by the device manufacturer's Technology Review Board (TRB) in
accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon
request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in
accordance with the intent specified in test method 1015 of MIL-STD-883.
b.
Interim and final electrical test parameters shall be as specified in table II, except interim electrical
parameters test prior to burn-in is optional at the discretion of the manufacturer.
c.
Additional screening for space level product shall be as specified in MIL-PRF-38535.
4.3 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-38535.
4.4 Technology Conformance inspection (TCI). Technology conformance inspection shall be in accordance with
MIL-PRF-38535 and herein for groups A, B, C, and D inspections (see 4.4.1 through 4.4.4).
TABLE II. Electrical test requirements.
Subgroups (see table III)
1/ 2/ 3/
Class S
Class B
devices 4/
devices
MIL-PRF-38535
test requirements
Interim electrical parameters
1
Final electrical test parameters
1
1, 2, 3, 9
Group A test requirements
Group B electrical test parameters when
using the method 5005 QCI option
Group C end-point electrical
parameters
Additional electrical subgroups for group C
periodic inspections
Group D end-point electrical
parameters
Additional electrical subgroups for group D
periodic inspection
1/ PDA applies to subgroup 1.
2/ See 4.4.1c
3/ See 4.4.1e
4/ See 4.4.4b
9
1, 2, 3,9
1,2,3,4,9,10,
11,12,13
1,2,3 and
table IV delta
limits
1,2,3 and
table IV delta
limits
N/A
1,2,3,4,9,12,13
10, 11, 12
1,2,3
1
12
None
N/A
1 and table IV delta
limits
MIL-M-38510/190D
Device type 01
Case X
Device type 02
Case X
Dev
Figure 1. Terminal connections.
10
MIL-M-38510/190D
Device type 03
Case X
Device type 04
Case X
Figure 1. Terminal connections – Continued.
11
MIL-M-38510/190D
Device types 05 and 07
Case E
Device types 06 and 08
Case E
Figure 1. Terminal connections – Continued.
12
MIL-M-38510/190D
Device types 01 and 02
NOTE: Optional (normally left open)
FIGURE 2. Functional diagrams.
13
MIL-M-38510/190D
Device types 03 and 04
NOTE: Optional (normally left open)
FIGURE 2. Functional diagrams – Continued.
14
MIL-M-38510/190D
Device types 05 and 07
Device types 06 and 08
FIGURE 2. Functional diagrams – Continued.
15
MIL-M-38510/190D
Device types 01 and 02
A3
A2
A1
A0
EN
X
L
L
L
L
L
L
L
L
H
H
H
H
H
H
H
H
X
L
L
L
L
H
H
H
H
L
L
L
L
H
H
H
H
X
L
L
H
H
L
L
H
H
L
L
H
H
L
L
H
H
X
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
CHANNEL
SELECTED
NONE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Device types 03 and 04
A2
A1
A0
EN
X
L
L
L
L
H
H
H
H
X
L
L
H
H
L
L
H
H
X
L
H
L
H
L
H
L
H
L
H
H
H
H
H
H
H
H
FIGURE 3. Truth tables.
16
CHANNEL
SELECTED
NONE
1A, 1B
2A, 2B
3A, 3B
4A, 4B
5A, 5B
6A, 6B
7A, 7B
8A, 8B
MIL-M-38510/190D
Device types 05 and 07
A2
A1
A0
EN
X
L
L
L
L
H
H
H
H
X
L
L
H
H
L
L
H
H
X
L
H
L
H
L
H
L
H
L
H
H
H
H
H
H
H
H
CHANNEL
SELECTED
NONE
1
2
3
4
5
6
7
8
Device types 06 and 08
A1
A0
EN
X
L
L
H
H
X
L
H
L
H
L
H
H
H
H
CHANNEL
SELECTED
NONE
1A, 1B
2A, 2B
3A, 3B
4A, 4B
FIGURE 3. Truth tables – Continued.
17
MIL-M-38510/190D
FIGURE 4. Case outline X.
18
MIL-M-38510/190D
Symbol
A
b
b1
C
D
E
E1
E2
E3
e
L
L1
Q
Q1
S
S1
S2
α
Inches
Min
Max
---.200
.014
.023
.040
.070
.008
.014
---1.48
.520
.610
.585
.620
N/A
N/A
N/A
N/A
.100 BSC
.125
.200
.150
.015
.060
N/A
N/A
---.098
.005
---.005
---0°
15°
Millimeters
Min
Max
---5.08
0.36
0.58
1.02
1.78
.20
0.36
---37.6
13.21
13.97
14.86
15.75
N/A
N/A
N/A
N/A
2.54 BSC
3.18
5.08
3.81
5.08
0.51
1.52
N/A
N/A
---2.49
0.13
---0.13
N/A
0°
15°
Notes
8
2, 8
8
4
4
7
5, 9
3
6
6
NOTES:
1.
Index area; a notch or a pin one identification mark shall be located adjacent to pin one and shall be located
Within the shaded area shown. The manufacturer’s identification shall not be used as a pin one identification
mark.
2.
The minimum limit for dimension b1 may be .023 (.58 mm) for leads number 1, 14, 15, and 28 only.
3.
Dimension Q shall be measured from the seating plane to the base plane.
4.
This dimension allows for off-center lid, meniscus and glass overrun.
5.
The basic pin spacing is .100 (2.54 mm) between centerlines. Each pin centerline shall be located within
±.010 (.25 mm) of its exact longitudinal position relative to pins 1 and 28.
6.
Applies to all four corners (leads number 1, 14, 15, and 28).
7.
Lead center when α = 0°. E1 shall be measured at the centerline of the leads.
8.
All leads – Increase maximum limit by .003 (.08 mm) measured at the center of the flat, when lead finish A or
B is applied.
9.
Twenty six spaces.
10.
If this configuration is used, no organic or polymeric materials shall be molded to the bottom of the package
to cover the leads.
FIGURE 4. Case outline X – Continued.
19
MIL-M-38510/190D
Device types 02, 04, 05, and 06
NOTES:
1.
All device inputs shall be protected from transients such a electrostatic discharge. This circuit is
Intrinsic to the device.
2.
This resistance is 200 to 2,000 Ω depending on device type.
FIGURE 5. Address and Enable input protection circuit.
20
MIL-M-38510/190D
Device types 01 and 02
Address inputs to I/O
Input pulse requirements:
VGEN = 4 V
tTHL(1) = tTLH(1) ≤ 20 ns
DYNAMIC TEST WAVEFORMS
FIGURE 6. Switching time test circuit and waveforms.
21
MIL-M-38510/190D
Device types 01 and 02
Enable to I/O
Input pulse requirements:
VGEN = 4 V
tTHL(1) = tTLH(1) ≤ 20 ns
DYNAMIC TEST WAVEFORMS
FIGURE 7. Switching time test circuit and waveforms.
22
MIL-M-38510/190D
Device types 03 and 04
Address inputs to I/O
Input pulse requirements:
VGEN = 4 V
tTHL(1) = tTLH(1) ≤ 20 ns
DYNAMIC TEST WAVEFORMS
FIGURE 8. Switching time test circuit and waveforms.
23
MIL-M-38510/190D
Device types 03 and 04
Enable to I/O
Input pulse requirements:
VGEN = 4 V
tTHL(1) = tTLH(1) ≤ 20 ns
DYNAMIC TEST WAVEFORMS
FIGURE 9. Switching time test circuit and waveforms.
24
MIL-M-38510/190D
Device types 05 and 07
Address inputs to I/O
Input pulse requirements:
VGEN = 4 V
tTHL(1) = tTLH(1) ≤ 20 ns
DYNAMIC TEST WAVEFORMS
FIGURE 10. Switching time test circuit and waveforms.
25
MIL-M-38510/190D
Device types 05 and 07
Enable to I/O
DYNAMIC TEST WAVEFORMS
Input pulse requirements:
VGEN = 4 V
tTHL(1) = tTLH(1) ≤ 20 ns
FIGURE 11. Switching time test circuit and waveforms.
26
MIL-M-38510/190D
Device types 06 and 08
Address inputs to I/O
Input pulse requirements:
VGEN = 4 V
tTHL(1) = tTLH(1) ≤ 20 ns
DYNAMIC TEST WAVEFORMS
FIGURE 12. Switching time test circuit and waveforms.
27
MIL-M-38510/190D
Device types 06 and 08
Enable to I/O
Input pulse requirements:
VGEN = 4 V
tTHL(1) = tTLH(1) ≤ 20 ns
DYNAMIC TEST WAVEFORMS
FIGURE 13. Switching time test circuit and waveforms.
28
MIL-M-38510/190D
Input pulse requirements:
VGEN = 4 V
tTHL(1) = tTLH(1) ≤ 20 ns
FIGURE 14. Break before make test circuit and waveforms.
29
MIL-M-38510/190D
NOTE: The pulse generator has the following characteristics: VGEN = 1 VP-P, PRR = 200 kHz.
FIGURE 15. Single channel isolation test circuit.
NOTE: The pulse generator has the following characteristics: VGEN = 1 VP-P, PRR = 200 kHz.
FIGURE 16. Crosstalk test circuit.
30
MIL-M-38510/190D
NOTE: The pulse generator has the following characteristics: VGEN = 0 – 5 V.
FIGURE 17. Charge transfer error test circuit.
31
TABLE III. Group A inspection for device type 01.
Symbol
IIH 2/
IIL 2/
IS(OFF)
3/
3010
“
“
“
“
3009
“
“
“
“
Test
no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
Terminal conditions 1/
Measured
Terminal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
V+
NC
NC
IN16
IN15
IN14
IN13
IN12
IN11
IN10
IN9
GND
NC
A3
-10 V
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
‘
-10 V
10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
‘
“
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
“
‘
“
“
“
“
“
“
-10 V
10 V
10 V
-10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
“
“
‘
“
“
“
“
“
-10 V
10 V
10 V
10 V
-10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
-10 V
-10 V
10 V
“
“
“
“
“
“
‘
“
“
“
“
-10 V
10 V
“
“
“
-10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
10 V
“
“
“
“
“
“
‘
“
“
“
-10 V
10 V
“
“
“
“
-10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
10 V
“
“
“
“
“
“
‘
“
“
-10 V
10 V
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
10 V
“
“
“
“
“
“
‘
“
-10 V
10 V
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
2.4 V
GND
“
“
“
0.8 V
5V
“
“
“
0.8 V
“
“
“
“
“
“
“
2.4 V
“
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
“
2.4 V
“
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
“
“
A3
A2
A1
A0
EN
A3
A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
OUT
OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
Test limits
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-0.1
“
“
“
“
-1.0
“
“
“
“
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-20
“
“
“
“
“
“
“
“
-0.1
“
“
“
“
-1.0
“
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-500
“
“
“
“
“
“
“
“
-0.1
“
“
“
“
-1.0
“
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-500
“
“
“
“
“
“
“
“
µA
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
20
“
“
“
“
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
500
“
“
“
“
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
500
“
“
“
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
32
ID-(OFF)
ID+(OFF)
ID+(ON)
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 01 – Continued.
Symbol
IIH 2/
IIL 2/
IS(OFF)
3/
Test
no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
Terminal conditions 1/
15
16
17
18
19
20
21
22
23
24
25
26
27
28
A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
V-
OUT
GND
2.4 V
GND
GND
GND
5V
0.8 V
5V
5V
5V
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
“
“
2.4 V
2.4 V
2.4 V
GND
GND
2.4 V
GND
GND
5V
5V
0.8 V
5V
5V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
“
“
“
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
GND
GND
GND
2.4 V
GND
5V
“
“
0.8 V
5V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
0.8 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
GND
“
“
“
2.4 V
5V
“
“
“
0.8 V
0.8 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
‘
“
“
“
“
“
“
“
“
“
“
4.5 V
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
-15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
‘
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
‘
“
“
“
“
“
“
“
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
10 V
10 V
-10 V
10 V
“
“
“
‘
“
“
“
“
“
“
“
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
-10 V -10 V
-10 V
“
-10 V
“
10 V
“
-10 V 10 V
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
10 V
“
10 V
“
-10 V
“
10 V -10 V
“
10 V
“
“
‘
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V -10 V
“
“
“
“
“
“
10 V
“
-10 V 10 V
-10 V -10 V
-10 V -10 V
Test limits
Measured
Terminal
-10 V
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
10 V
-10 V
-10 V
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
A3
A2
A1
A0
EN
A3
A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
OUT
OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-0.1
“
“
“
“
-1.0
“
“
“
“
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-20
“
“
“
“
“
“
“
“
-0.1
“
“
“
“
-1.0
“
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-500
“
“
“
“
“
“
“
“
-0.1
“
“
“
“
-1.0
“
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-500
“
“
“
“
“
“
“
“
µA
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
20
“
“
“
“
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
500
“
“
“
“
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
500
“
“
“
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
33
ID-(OFF)
ID+(OFF)
ID+(ON)
Case
X
TABLE III. Group A inspection for device types 01 – Continued.
Symbol
ID+(ON)
ID-(ON)
Test
no.
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
Terminal conditions 1/
1
2
3
4
5
6
7
8
9
10
11
12
13
14
V+
NC
NC
IN16
IN15
IN14
IN13
IN12
IN11
IN10
IN9
GND
NC
A3
-10 V
“
“
“
“
“
“
“
10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
-10 V
“
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
10 V
-10 V -10 V -10 V
“
“
-10 V
“
“
-10 V
“
“
10 V
“
10 V -10 V
10 V -10 V
“
-10 V
“
“
-10 V
“
“
-10 V
“
“
10 V 10 V 10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
-10 V 10 V
-10 V 10 V
“
10 V
“
“
10 V
“
“
10 V
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
10 V
10 V
10 V
10 V
10 V
10 V
10 V
10 V
Test limits
Measured
Terminal
0.8 V
2.4 V
“
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
“
2.4 V
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
“
“
“
“
2.4 V
“
“
“
“
“
“
“
0.8 V
“
“
“
“
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
V+
VV+
VIN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-20
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-14
“
-4.0
-500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
mA
“
“
“
Ω
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
20
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
-14
3.0
-14
3.0
-4.0
600
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
3.0
-4.0
700
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
600
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
34
I+
II+SBY
I-SBY
RDS1
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 01 – Continued.
Symbol
ID+(ON)
ID-(ON)
Test
no.
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
Terminal conditions 1/
15
16
17
18
19
20
21
22
23
24
25
26
27
28
A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
V-
OUT
2.4 V
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0V
“
“
“
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
-10 V
“
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
10 V
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
10 V
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
2.4 V 4.5 V
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
‘
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
‘
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
‘
0.8 V
“
2.4 V
“
0V
5V
“
5V
“
0V
“
0V
0.8 V 4.5 V
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
2.4 V
“
0.8 V
“
See footnotes at end of table.
-10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
10 V 10 V
-10 V 10 V
10 V -10 V
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
10 V
10 V
10 V
10 V
10 V
10 V
10 V
-10 V
-10 V
-10 V
-10 V
-10 V
Test limits
Measured
Terminal
-15 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
100 µA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-100 µA
“
“
“
“
“
“
“
“
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
V+
VV+
VIN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-20
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
mA
“
“
“
Ω
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
20
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
-14
500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
-14
3.0
-4.0
-14
3.0
-4.0
600
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
3.0
-4.0
700
“
“
“
“
“
“
“
“
“
“
“
“
600
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
35
I+
II+SBY
I-SBY
RDS1
Case
X
TABLE III. Group A inspection for device type 01 – Continued.
Symbol
MIL- Case
STD-883 X
method
RDS2
RDS2
36
CEN
2
3
4
5
6
7
8
9
10
11
12
13
14
3012
“
“
“
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
4/
4/
4/
4/
4/
4/
4/
4/
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4/
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
A3
A2
A1
A0
OUT
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
EN
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
600
“
“
“
“
“
“
“
“
“
“
1
1
Subgroup 4
TA = 25°C
Min
Max
10
“
“
“
90
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
700
“
“
“
“
“
“
“
“
“
“
1
1
600
“
“
“
“
“
“
“
“
“
“
1
1
Ω
“
“
“
“
“
“
“
“
“
“
kΩ
kΩ
pF
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
COS
CIS
1
Test limits
Measured
Terminal
Test V+
NC
NC IN16 IN15 IN14 IN13 IN12 IN11
IN10
IN9
GND
NC
A3
no.
102 15 V
GND
0.8 V IN6 & OUT
103
“
“
“
IN7 & OUT
104
“
“
“
IN8 & OUT
105
“
-10 V
“
2.4 V IN9 & OUT
106
“
-10 V
“
“
IN10 & OUT
107
“
-10 V
“
“
IN11 & OUT
108
“
-10 V
“
“
IN12 & OUT
109
“
-10 V
“
“
IN13 & OUT
110
“
-10 V
“
“
IN14 & OUT
111
“
-10 V
“
“
IN15 & OUT
112
“
-10 V
“
“
IN16 & OUT
113-128 - Same terminal conditions as for tests 81 thru 96, except V± = ± 10 V, VS = +7.5 V and limits as shown.
129-144 - Same terminal conditions as for tests 97 thru 112, except V± = ± 10 V, VS = -7.5 V and limits as shown.
RDS1
CA
Terminal conditions 1/
TABLE III. Group A inspection for device type 01 – Continued.
Symbol
RDS1
RDS2
RDS2
CA
37
CEN
Terminal conditions 1/
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Test A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
VOUT
no.
102 2.4 V 0.8 V 2.4 V 4.5 V
-10 V
-15 V -100 µA IN6 & OUT
103 2.4 V 2.4 V 0.8 V
“
-10 V
“
“
IN7 & OUT
104 2.4 V 2.4 V 2.4 V
“
-10 V
“
“
IN8 & OUT
105 0.8 V 0.8 V 0.8 V
“
“
“
IN9 & OUT
106
“
0.8 V 2.4 V
“
“
“
IN10 & OUT
107
“
2.4 V 0.8 V
“
“
“
IN11 & OUT
108
“
2.4 V 2.4 V
“
“
“
IN12 & OUT
109 2.4 V 0.8 V 0.8 V
“
“
“
IN13 & OUT
110
“
0.8 V 2.4 V
“
“
“
IN14 & OUT
111
“
2.4 V 0.8 V
“
“
“
IN15 & OUT
112
“
2.4 V 2.4 V
“
“
“
IN16 & OUT
113-128 - Same terminal conditions as for tests 81 thru 96, except V± = ± 10 V, VS = +7.5 V and limits as shown.
129-144 - Same terminal conditions as for tests 97 thru 112, except V± = ± 10 V, VS = -7.5 V and limits as shown.
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
4/
4/
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
4/
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4/
Test limits
Measured
Terminal
4/
4/
4/
4/
4/
4/
4/
4/
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
5/
A3
A2
A1
A0
OUT
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
EN
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
600
“
“
“
“
“
“
“
“
“
“
1
1
Subgroup 4
TA = 25°C
Min
Max
10
“
“
“
90
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
700
“
“
“
“
“
“
“
“
“
“
1
1
600
“
“
“
“
“
“
“
“
“
“
1
1
Ω
“
“
“
“
“
“
“
“
“
“
kΩ
kΩ
pF
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
COS
CIS
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 01 – Continued.
Symbol
MIL- Case
STD-883 X
method
Terminal conditions 1/
1
2
3
4
5
6
7
8
9
10
11
12
13
14
V+
NC
NC
IN16
IN15
IN14
IN13
IN12
IN11
IN10
IN9
GND
NC
A3
15 V
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
VISO
VCT
VCTE
fig. 15
fig. 16
fig. 17
179
180
181
15 V
15 V
15 V
IN
IN
IN
IN
IN
IN
IN
IN
tD
fig. 14
“
“
“
182
183
184
185
15 V
“
“
“
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
tON(A)
and
tOFF(A)
tON(EN)
and
tOFF(EN)
38
See footnotes at end of table.
GND GND GND
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V -10 V -10 V -10 V
10 V 10 V
10 V
10 V
-10 V -10 V -10 V -10 V
10 V 10 V
10 V
10 V
IN
IN
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
Subgroup 9
TA = 25°C
Min
Max
GND
“
“
“
“
“
“
“
GND
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
GND
“
“
“
ADDRESS
IN TO OUT
“
“
“
“
“
“
ENABLE
TO OUT
IN
IN
IN
IN
IN
IN
GND
GND
GND
GND
GND
IN
OUT
OUT
OUT
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
GND
“
“
“
_/¯
_/¯
¯\_
¯\_
OUT
“
“
“
1,000
“
“
“
“
“
“
“
“
“
“
“
Subgroup 12
TA = 25°C
Min
Max
50
50
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
Unit
ns
“
“
“
“
“
“
“
“
“
“
“
dB
dB
mV
ns
“
“
“
MIL-M-38510/190D
3003
fig. 6
“
“
“
“
“
“
fig. 7
“
“
“
Test
no.
167
168
169
170
171
172
173
174
175
176
177
178
Test limits
Measured
Terminal
TABLE III. Group A inspection for device type 01 – Continued.
Symbol
MIL- Case
STD-883 X
method
Terminal conditions 1/
15
16
17
18
19
20
21
22
23
24
25
26
27
28
IN4
IN5
IN6
IN7
IN8
V-
OUT
-15 V
“
“
“
“
“
“
“
“
“
“
“
OUT
“
“
“
“
“
“
“
“
“
“
“
ADDRESS
IN TO OUT
“
“
“
“
“
“
ENABLE
TO OUT
EN
IN1
IN2
IN3
5V
“
“
“
“
“
“
“
_/¯
¯\_
_/¯
¯\_
GND
“
“
“
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
VISO
VCT
VCTE
179
180
181
0V
5V
5V
IN
6/
GND
IN
IN
IN
IN
tD
182
183
184
185
5V
“
“
“
10 V
-10 V
10 V
-10 V
tON(A)
and
tOFF(A)
tON(EN)
and
tOFF(EN)
GND GND GND
GND GND GND
IN
IN
IN
39
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
See footnotes at end of table.
_/¯
_/¯
¯\_
¯\_
GND GND GND
GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V -10 V -10 V -10 V -10 V
10 V 10 V
10 V
10 V
10 V
-10 V -10 V -10 V -10 V -10 V
10 V 10 V
10 V
10 V 10 V
IN
IN
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
Subgroup 9
TA = 25°C
Min
Max
IN
IN
IN
IN
IN
IN
IN
IN
-15 V
-15 V
-15 V
OUT
OUT
OUT
OUT
OUT
OUT
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
-15 V
“
“
“
OUT
“
“
“
OUT
“
“
“
1,000
“
“
“
“
“
“
“
“
“
“
“
Subgroup 12
TA = 25°C
Min
Max
50
50
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
Unit
ns
“
“
“
“
“
“
“
“
“
“
“
dB
dB
mV
ns
“
“
“
MIL-M-38510/190D
Test A2
A1
A0
no.
167
_/¯
_/¯
_/¯
168
_/¯
_/¯
_/¯
169
¯\_
¯\_
¯\_
170
¯\_
¯\_
¯\_
171
_/¯
_/¯
_/¯
172
_/¯
_/¯
_/¯
173
¯\_
¯\_
¯\_
174
¯\_
¯\_
¯\_
175 GND GND GND
176
“
“
“
177
“
“
“
178
“
“
“
Test limits
Measured
Terminal
TABLE III. Group A inspection for device type 02 .
Symbol
MIL- Case
STD-883 X
method
VIC(POS)
VIC(NEG)
IIH 2/
IIL 2/
1
40
Test V+
no.
1
GND
2
“
3
“
4
“
5
“
6
7
8
9
10
11 15 V
12
“
13
“
14
“
15
“
16
“
17
“
18
“
19
“
20
“
21
“
22
“
23
“
24
“
25
“
26
“
27
“
28
“
29
“
30
“
31
“
32
“
33
“
34
“
35
“
36
“
37
“
38
“
39
“
40
“
41
“
42
“
43
“
44
“
45
“
46
“
47
“
48
“
49
“
50
“
2
3
4
5
6
7
8
9
10
11
12
13
14
NC
NC
IN16
IN15
IN14
IN13
IN12
IN11
IN10
IN9
GND
VREF
A3
-10 V
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
-10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
10 V -10 V
10 V 10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
-10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
10 V -10 V
-10 V
“
-10 V
“
-10 V
“
10 V 10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
-10 V 10 V
10 V 10 V
-10 V
“
“
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
-10 V
10 V
10 V
10 V
Test limits
Measured
Terminal
-10 V
“
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
1 mA
-1 mA
4.0 V
GND
“
“
“
0.8 V
5V
“
“
“
0.8 V
“
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
“
4.0 V
“
“
“
“
“
Subgroup 1
TA = 25°C
Min
Max
A3
A2
A1
A0
EN
A3
A2
A1
A0
EN
A3
A2
A1
A0
EN
A3
A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
1.5
“
“
“
“
-1.5
“
“
“
“
-0.1
“
“
“
“
-1.0
“
“
“
“
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
“
-1.0
“
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
“
-1.0
“
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Unit
V
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
IS(OFF)
3/
3010
“
“
“
“
3009
“
“
“
“
Terminal conditions 1/
TABLE III. Group A inspection for device type 02 – Continued.
Symbol
VIC(POS)
VIC(NEG)
IIH 2/
IIL 2/
41
Test
no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Terminal conditions 1/
15
16
17
18
19
20
21
22
23
24
25
26
27
28
A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
V-
OUT
1 mA
1 mA
1 mA
1 mA
-1 mA
-1 mA
-1 mA
-1 mA
GND
4.0 V
GND
GND
GND
5V
0.8 V
5V
5V
5V
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
4.0 V
GND
GND
4.0 V
GND
GND
5V
5V
0.8 V
5V
5V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
GND 15 V
GND
“
GND
“
4.0 V
“
GND 4.0 V
5V
5V
5V
“
5V
“
0.8 V
“
5 V 0.8 V
0.8 V
“
10 V -10 V -10 V
4.0 V
“
-10 V 10 V -10 V
0.8 V
“
“
-10 V 10 V
4.0 V
“
“
“
-10 V
0.8 V
“
“
“
“
4.0 V
“
“
“
“
0.8 V
“
“
“
“
4.0 V
“
“
“
“
0.8 V
“
“
“
“
4.0 V
“
“
“
“
0.8 V
“
“
“
“
4.0 V
“
“
“
“
0.8 V
“
“
“
“
4.0 V
“
“
“
“
0.8 V
“
“
“
“
4.0 V
“
“
“
“
0.8 V
“
“
10 V 10 V
4.0 V
“
10 V -10 V 10 V
0.8 V
“
“
10 V -10 V
4.0 V
“
“
“
10 V
0.8 V
“
“
“
“
4.0 V
“
“
“
“
0.8 V
“
“
“
“
4.0 V
“
“
“
“
0.8 V
“
“
“
“
4.0 V
“
“
“
“
0.8 V
“
“
“
“
4.0 V
“
“
“
“
0.8 V
“
“
“
“
4.0 V
“
“
“
“
See footnotes at end of table.
-10 V -10 V
-10 V
“
-10 V
“
10 V
“
-10 V 10 V
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
10 V
“
10 V
“
-10 V
“
10 V -10 V
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Test limits
Measured
Terminal
-10 V
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
GND
“
“
“
“
-15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 1
TA = 25°C
Min
Max
A3
A2
A1
A0
EN
A3
A2
A1
A0
EN
A3
A2
A1
A0
EN
A3
A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
1.5
“
“
“
“
-1.5
“
“
“
“
-0.1
“
“
“
“
-1.0
“
“
“
“
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
“
-1.0
“
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
“
-1.0
“
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
“
0.1
“
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Unit
V
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
IS(OFF)
3/
Case
X
TABLE III. Group A inspection for device type 02 – Continued.
Symbol
IS(OFF)
3/
ID(OFF)
ID(ON)
Test
no.
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
Terminal conditions 1/
1
2
3
4
5
6
7
8
9
10
11
12
13
14
V+
NC
NC
IN16
IN15
IN14
IN13
IN12
IN11
IN10
IN9
GND
VREF
A3
15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
10 V
-10 V
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
-10 V
-10 V 10 V
10 V
10 V
10 V
10 V
10 V 10 V
10 V
-10 V -10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
10 V -10 V
10 V -10 V
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
-10 V 10 V
-10 V 10 V
10 V
10 V 10 V
10 V
Test limits
Measured
Terminal
10 V 10 V 10 V
10 V
10 V 10 V
10 V
10 V
10 V 10 V
10 V
10 V
-10 V -10 V -10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
10 V -10 V
“
10 V -10 V
“
10 V -10 V
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
10 V
10 V
“
“
“
10 V
“
“
“
10 V
“
“
“
-10 V
“
“
-10 V 10 V
“
-10 V 10 V
“
-10 V 10 V
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
33 V
33 V
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4.0 V
4.0 V
0.8 V
“
4.0 V
0.8 V
4.0 V
“
“
“
“
“
“
“
0V
“
“
“
0.8 V
“
“
“
“
“
“
“
4.0 V
4.0 V
IN15
IN16
OUT
OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
V+
VV+
VOUT
“
“
“
“
“
“
“
“
“
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-1
“
-20
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-50
-50
-500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-50
“
-500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
mA
“
“
“
µA
“
“
“
“
“
“
“
“
“
1
“
20
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
-1
-1
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
50
50
500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
2.0
“
“
“
“
“
“
“
“
“
-1
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
50
“
500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
2.0
“
“
“
“
“
“
“
“
“
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
42
I+
II+SBY
I-SBY
ID+(OFF)
open
voltage
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 02 – Continued.
Symbol
IS(OFF)
3/
ID(OFF)
ID(ON)
Test
no.
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
Terminal conditions 1/
15
16
17
18
19
20
21
22
23
24
25
26
27
28
A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
V-
OUT
4.0 V
4.0 V
0.8 V
“
“
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
“
“
“
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0V
“
“
“
0.8 V
“
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
0.8 V
4.0 V
0.8 V
0.8 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0V
“
“
“
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
4.0 V
0.8 V
“
“
“
4.0 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
5.0 V
“
0V
“
0.8 V
“
“
“
“
“
“
“
“
“
-15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
10 V 10 V
10 V
10 V
10 V
10 V
10 V 10 V
10 V
-10 V -10 V -10 V
10 V -10 V -10 V
-10 V 10 V -10 V
“
-10 V 10 V
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
10 V
10 V -10 V 10 V
“
10 V -10 V
“
10 V
10 V
“
10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Test limits
Measured
Terminal
10 V 10 V 10 V
10 V 10 V
10 V 10 V
10 V
10 V
10 V
10 V 10 V
10 V
10 V
10 V
-10 V -10 V -10 V -10 V -10 V
-10 V
“
“
“
“
-10 V
“
“
“
“
-10 V
“
“
“
“
10 V
“
“
“
“
-10 V 10 V
“
“
“
“
-10 V 10 V
“
“
“
“
-10 V 10 V
“
“
“
“
-10 V 10 V
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
10 V
10 V
10 V
10 V
“
“
“
“
10 V
“
“
“
“
-10 V
“
“
“
“
10 V -10 V
“
“
“
“
“
-10 V
“
“
“
“
“
-10 V
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
33 V
33 V
33 V
33 V
33 V
33 V
33 V
33 V
0V
“
“
“
“
“
“
“
“
“
IN15
IN16
OUT
OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
V+
VV+
VOUT
“
“
“
“
“
“
“
“
“
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-1
“
-20
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-50
-50
-500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-50
“
-500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
mA
“
“
“
µA
“
“
“
“
“
“
“
“
“
1
“
20
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
-1
-1
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
50
50
500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
2.0
“
“
“
“
“
“
“
“
“
-1
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
50
“
500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
2.0
“
“
“
“
“
“
“
“
“
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
43
I+
II+SBY
I-SBY
ID+(OFF)
over
voltage
Case
X
TABLE III. Group A inspection for device type 02 – Continued.
Symbol
MIL- Case
STD-883 X
method
Terminal conditions 1/
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A3
4.0 V
“
“
“
“
“
0.8 V
“
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
“
OUT
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN9 & OUT
IN10 & OUT
IN11 & OUT
IN12 & OUT
IN13 & OUT
IN14 & OUT
IN15 & OUT
IN16 & OUT
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
kΩ
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.4
2.4
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.4
2.4
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.4
2.4
MIL-M-38510/190D
44
Test V+
NC NC IN16 IN15 IN14
IN13 IN12 IN11
IN10
IN9
GND
VREF
no.
ID+(OFF)
101 15 V
33 V
GND
over102
“
33 V
“
voltage
103
“
33 V
“
104
“
33 V
“
105
“
33 V
“
106
“
33 V
“
ID-(OFF)
107
“
“
over108
“
“
voltage
109
“
“
110
“
“
111
“
“
112
“
“
113
“
“
114
“
“
115
“
-33 V
“
116
“
-33 V
“
117
“
-33 V
“
118
“
-33 V
“
119
“
-33 V
“
120
“
-33 V
“
121
“
-33 V
“
122
“
-33 V
“
RDS1
123
“
“
124
“
“
125
“
“
126
“
“
127
“
“
128
“
“
129
“
“
130
“
“
131
“
10 V
“
132
“
10 V
“
133
“
10 V
“
134
“
10 V
“
135
“
10 V
“
136
“
10 V
“
137
“
10 V
“
138
“
10 V
“
139
“
“
140
“
“
141
“
“
142
“
“
143
“
“
144
“
“
145
“
“
146
“
“
147
“
-10 V
“
148
“
-10 V
“
149
“
-10 V
“
150
“
-10 V
“
151
“
-10 V
“
152
“
-10 V
“
153
“
-10 V
“
154
“
-10 V
“
RDS2
155 thru 170 – Same terminal conditions as tests 123 thru 138, except V± = ±10 V, VS = +7.5 V, and limits as shown.
RDS2
171 thru 186 – Same terminal conditions as tests 139 thru 154, except V± = ±10 V, VS = -7.5 V, and limits as shown.
See footnotes at end of table.
Test limits
Measured
Terminal
TABLE III. Group A inspection for device type 02 – Continued.
Symbol
Case
X
Terminal conditions 1/
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
kΩ
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.4
2.4
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.4
2.4
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.4
2.4
MIL-M-38510/190D
45
Test A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
VOUT
no.
ID+(OFF)
101 0.8 V 4.0 V 0.8 V 0.8 V
-15 V
OUT
over102 0.8 V 4.0 V 4.0 V
“
“
“
voltage 103 4.0 V 0.8 V 0.8 V
“
“
“
104
“
0.8 V 4.0 V
“
“
“
105
“
4.0 V 0.8 V
“
“
“
106
“
4.0 V 4.0 V
“
“
“
ID-(OFF)
107 0.8 V 0.8 V 0.8 V
“
-33 V
“
“
over108
“
0.8 V 4.0 V
“
-33 V
“
“
voltage 109
“
4.0 V 0.8 V
“
-33 V
“
“
110
“
4.0 V 4.0 V
“
-33 V
“
“
111 4.0 V 0.8 V 0.8 V
“
-33 V
“
“
112
“
0.8 V 4.0 V
“
-33 V
“
“
113
“
4.0 V 0.8 V
“
-33 V
“
“
114
“
4.0 V 4.0 V
“
-33 V
“
“
115 0.8 V 0.8 V 0.8 V
“
“
“
116
“
0.8 V 4.0 V
“
“
“
117
“
4.0 V 0.8 V
“
“
“
118
“
4.0 V 4.0 V
“
“
“
119 4.0 V 0.8 V 0.8 V
“
“
“
120
“
0.8 V 4.0 V
“
“
“
121
“
4.0 V 0.8 V
“
“
“
122
“
4.0 V 4.0 V
“
“
“
RDS1
123 0.8 V 0.8 V 0.8 V 4.0 V 10 V
“
100 µA IN1 & OUT
124
“
0.8 V 4.0 V
“
10 V
“
“
IN2 & OUT
125
“
4.0 V 0.8 V
“
10 V
“
“
IN3 & OUT
126
“
4.0 V 4.0 V
“
10 V
“
“
IN4 & OUT
127 4.0 V 0.8 V 0.8 V
“
10 V
“
“
IN5 & OUT
128
“
0.8 V 4.0 V
“
10 V
“
“
IN6 & OUT
129
“
4.0 V 0.8 V
“
10 V
“
“
IN7 & OUT
130
“
4.0 V 4.0 V
“
10 V
“
“
IN8 & OUT
131 0.8 V 0.8 V 0.8 V
“
“
“
IN9 & OUT
132
“
0.8 V 4.0 V
“
“
“
IN10 & OUT
133
“
4.0 V 0.8 V
“
“
“
IN11 & OUT
134
“
4.0 V 4.0 V
“
“
“
IN12 & OUT
135 4.0 V 0.8 V 0.8 V
“
“
“
IN13 & OUT
136
“
0.8 V 4.0 V
“
“
“
IN14 & OUT
137
“
4.0 V 0.8 V
“
“
“
IN15 & OUT
138
“
4.0 V 4.0 V
“
“
“
IN16 & OUT
139 0.8 V 0.8 V 0.8 V
“
-10 V
“
-100 µA IN1 & OUT
140
“
0.8 V 4.0 V
“
-10 V
“
“
IN2 & OUT
141
“
4.0 V 0.8 V
“
-10 V
“
“
IN3 & OUT
142
“
4.0 V 4.0 V
“
-10 V
“
“
IN4 & OUT
143 4.0 V 0.8 V 0.8 V
“
-10 V
“
“
IN5 & OUT
144
“
0.8 V 4.0 V
“
-10 V
“
“
IN6 & OUT
145
“
4.0 V 0.8 V
“
-10 V
“
“
IN7 & OUT
146
“
4.0 V 4.0 V
“
-10 V
“
“
IN8 & OUT
147 0.8 V 0.8 V 0.8 V
“
“
“
IN9 & OUT
148
“
0.8 V 4.0 V
“
“
“
IN10 & OUT
149
“
4.0 V 0.8 V
“
“
“
IN11 & OUT
150
“
4.0 V 4.0 V
“
“
“
IN12 & OUT
151 4.0 V 0.8 V 0.8 V
“
“
“
IN13 & OUT
152
“
0.8 V 4.0 V
“
“
“
IN14 & OUT
153
“
4.0 V 0.8 V
“
“
“
IN15 & OUT
154
“
4.0 V 4.0 V
“
“
“
IN16 & OUT
RDS2
155 thru 170 – Same terminal conditions as tests 123 thru 138, except V± = ±10 V, VS = +7.5 V, and limits as shown.
RDS2
171 thru 186 – Same terminal conditions as tests 139 thru 154, except V± = ±10 V, VS = -7.5 V, and limits as shown.
See footnotes at end of table.
Test limits
Measured
Terminal
TABLE III. Group A inspection for device type 02 – Continued.
Symbol
CA
COS
CIS
46
tON(A)
and
tOFF(A)
tON(EN)
and
tOFF(EN)
3012
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
3003
fig. 6
“
“
“
“
“
“
fig. 7
“
“
Terminal conditions 1/
1
Test V+
no.
187 GND
188
“
189
“
190
“
191
“
192
“
193
“
194
“
195
“
196
“
197
“
198
“
199
“
200
“
201
“
202
“
203
“
204
“
205
“
206
“
207
“
208
“
209
210
211
212
213
214
215
216
217
218
219
220
2
3
4
5
6
7
8
9
10
11
12
13
14
NC
NC
IN16
IN15
IN14
IN13
IN12
IN11
IN10
IN9
GND
VREF
A3
15 V
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
4/
4/
4/
4/
4/
4/
4/
4/
-10 V GND
10 V
“
-10 V
“
10 V
“
GND
“
“
“
“
“
“
“
-10 V -10 V
10 V 10 V
-10 V -10 V
10 V 10 V
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V -10 V
10 V 10 V
-10 V -10 V
10 V 10 V
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
Test limits
Measured
Terminal
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
A3
A2
A1
A0
OUT
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
GND
“
“
“
ADDRESS
IN TO OUT
“
“
“
“
“
“
“
“
“
“
Subgroup 4
TA = 25°C
Min
Max
Unit
10
“
“
“
85
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 9
TA = 25°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
pF
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
ns
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
CEN
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 02 – Continued.
Symbol
CA
COS
CIS
47
tON(A)
and
tOFF(A)
tON(EN)
and
tOFF(EN)
Test
no.
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
Terminal conditions 1/
15
16
17
18
19
20
21
22
23
24
25
26
27
28
A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
V-
OUT
4/
4/
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4/
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4/
_/¯
_/¯ _/¯ 5 V
_/¯
_/¯ _/¯
“
¯\_
¯\_ ¯\_
“
¯\_
¯\_ ¯\_
“
_/¯
_/¯ _/¯
“
_/¯
_/¯ _/¯
“
¯\_
¯\_ ¯\_
“
¯\_
¯\_ ¯\_
“
GND GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
4/
4/
4/
4/
4/
4/
4/
4/
GND
“
“
“
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
Test limits
Measured
Terminal
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
-15 V
“
“
“
“
“
“
“
“
“
“
“
5/
0V
“
“
“
“
“
“
OUT
“
“
“
“
“
“
“
“
“
“
“
A3
A2
A1
A0
OUT
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
EN
ADDRESS
IN TO OUT
“
“
“
“
“
“
“
“
“
“
Subgroup 4
TA = 25°C
Min
Max
Unit
10
“
“
“
85
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 9
TA = 25°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
pF
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
ns
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
CEN
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 02 – Continued.
Symbol
MIL- Case
STD-883 X
method
VISO
VCT
VCTE
fig. 15
fig. 16
fig. 17
Test
no.
221
222
223
tD
fig. 14
“
“
“
224
225
226
227
Terminal conditions 1/
1
2
3
4
5
6
7
8
9
10
11
12
13
14
V+
NC
NC
IN16
IN15
IN14
IN13
IN12
IN11
IN10
IN9
GND
VREF
A3
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
GND
GND
GND
GND
GND
IN
OUT
OUT
OUT
GND
“
“
“
_/¯
_/¯
¯\_
¯\_
OUT
“
“
“
15 V
15 V
15 V
IN
IN
15 V
“
“
“
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V 10 V
-10 V -10 V
10 V 10 V
-10 V -10 V
10 V
-10 V
10 V
-10 V
Test limits
Measured
Terminal
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
Subgroup 4
TA = 25°C
Min
Max
Unit
50
50
dB
dB
mV
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
ns
“
“
“
See footnotes at end of table.
MIL-M-38510/190D
48
TABLE III. Group A inspection for device type 02 – Continued.
Symbol
VISO
VCT
VCTE
tD
MIL- Case
STD-883 X
method
Terminal conditions 1/
15
18
19
20
21
22
23
24
25
26
27
28
Test A2
A1
A0
EN
no.
221 GND GND GND 0 V
222 GND GND GND 5 V
223
IN
IN
IN
5V
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
V-
OUT
IN
6/
GND
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
-15 V
-15 V
OUT
OUT
OUT
OUT
OUT
OUT
224
225
226
227
10 V 10 V
-10 V -10 V
10 V 10 V
-10 V -10 V
OUT
“
“
“
OUT
“
“
“
_/¯
_/¯
¯\_
¯\_
16
_/¯
_/¯
¯\_
¯\_
17
_/¯
_/¯
¯\_
¯\_
5V
“
“
“
10 V 10 V
-10 V -10 V
10 V 10 V
-10 V -10 V
10 V
-10 V
10 V
-10 V
Test limits
Measured
Terminal
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
-15 V
“
“
“
Subgroup 4
TA = 25°C
Min
Max
Unit
50
50
dB
dB
mV
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
ns
“
“
“
See footnotes at end of table.
MIL-M-38510/190D
MIL-M-38510/139C
49
42
TABLE III. Group A inspection for device type 03.
Symbol
IIH 2/
IIL 2/
IS(OFF)
3/
ID(ON)
3010
“
“
“
3009
“
“
“
Terminal conditions 1/
1
Test V+
no.
1
15 V
2
“
3
“
4
“
5
“
6
“
7
“
8
“
9
“
10
“
11
“
12
“
13
“
14
“
15
“
16
“
17
“
18
“
19
“
20
“
21
“
22
“
23
“
24
“
25
“
26
“
27
“
28
“
29
“
30
“
31
“
32
“
33
“
34
“
35
“
36
“
37
“
38
“
39
“
40
“
41
“
42
“
43
“
44
“
45
“
46
“
47
“
48
“
49
“
50
“
2
3
OUTB NC
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
‘
“
“
“
“
“
“
“
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
“
See footnotes at end of table.
4
5
6
7
8
9
10
11
12
13
14
IN8B
IN7B
IN6B
IN5B
IN4B
IN3B
IN2B
IN1B
GND
NC
NC
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
“
-10 V
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
“
-10 V
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
“
-10 V
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
“
-10 V
-10 V
-10 V
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
“
10 V
10 V
10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
10 V
10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
“
Test limits
Measured
Terminal
-10 V
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
“
A2
A1
A0
EN
A2
A1
A0
EN
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
OUTA
OUTA
OUTB
OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN5A & OUTA
IN6A & OUTA
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-0.1
“
“
“
-1.0
“
“
“
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
MIL-M-38510/139C
50
ID(OFF)
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 03 – Continued.
Symbol Case
X
IIH 2/
IIL 2/
IS(OFF)
3/
ID(ON)
15
16
17
18
19
20
21
22
23
24
25
26
27
28
A2
A1
A0
EN
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
V-
OUTA
2.4 V
GND
GND
GND
0.8 V
5.0 V
5.0 V
5.0 V
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
“
“
“
“
2.4 V
2.4 V
GND
2.4 V
GND
GND
5.0 V
0.8 V
5.0 V
5.0 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
“
“
“
“
“
2.4 V
2.4 V
0.8 V
0.8 V
GND
GND
2.4 V
GND
5.0 V
5.0 V
0.8 V
5.0 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
“
“
“
“
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
5.0 V
5.0 V
5.0 V
4.5 V
5.0 V
5.0 V
5.0 V
0.8 V
0.8 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4.5 V
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
“
“
-15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
-10 V
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
-10 V
10 V
-10 V
-10 V
10 V
-10 V
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
-10 V
10 V
-10 V
-10 V
-10 V
10 V
-10 V
-10 V
-10 V
-10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
-10 V 10 V
“
-10 V
“
-10 V
“
-10 V
10 V 10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
10 V -10 V
“
10 V
“
“
“
“
“
“
-10 V -10 V
10 V 10 V
-10 V -10 V
-10 V
“
-10 V
“
-10 V
“
10 V
“
-10 V 10 V
-10 V -10 V
Test limits
Measured
Terminal
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
10 V
-10 V
10 V
“
“
“
“
“
A2
A1
A0
EN
A2
A1
A0
EN
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
OUTA
OUTA
OUTB
OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN5A & OUTA
IN6A & OUTA
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-0.1
“
“
“
-1.0
“
“
“
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
51
ID(OFF)
Test
no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Terminal conditions 1/
TABLE III. Group A inspection for device type 03 – Continued.
Symbol
ID(ON)
Terminal conditions 1/
1
Test V+
no.
51 15 V
52
“
53
“
54
“
55
“
56
“
57
“
58
“
59
“
60
“
61
“
62
“
63
“
64
“
65
“
66
“
67
“
68
“
69
“
70
“
71
“
72
“
73
“
74
“
75
“
76
“
77
“
78
“
79
“
80
“
81
“
82
“
83
“
84
“
85
“
86
“
87
“
88
“
89
“
90
“
91
“
92
“
93
“
94
“
95
“
96
“
97
“
98
“
99
“
100
“
2
3
OUTB NC
-10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
4
5
6
7
8
9
10
11
12
13
14
IN8B
IN7B
IN6B
IN5B
IN4B
IN3B
IN2B
IN1B
GND
NC
NC
-10 V -10 V -10 V -10 V
“
“
“
-10 V
“
“
“
-10 V
“
“
“
10 V
“
“
10 V -10 V
“
10 V -10 V
“
10 V -10 V
“
“
-10 V
“
“
“
-10 V
“
“
“
-10 V
“
“
“
10 V 10 V 10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
-10 V 10 V
“
-10 V 10 V
“
-10 V 10 V
“
“
10 V
“
“
“
10 V
“
“
“
10 V
“
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V -10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
10 V -10 V
10 V -10 V -10 V
“
10 V 10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
-10 V 10 V
-10 V 10 V 10 V
10 V
10 V
10 V
10 V
10 V
10 V
10 V
1 mA
“
“
“
“
“
“
“
See footnotes at end of table.
10 V
Test limits
Measured
Terminal
IN7A & OUTA
IN8A & OUTB
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN5A & OUTA
IN6A & OUTA
IN7A & OUTA
IN8A & OUTB
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
V+
VV+
VIN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN5A & OUTA
IN6A & OUTA
IN7A & OUTA
IN8A & OUTB
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
mA
“
“
“
Ω
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
-14
250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
-14
3.0
-4.0
-14
3.0
-4.0
600
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
3.0
-4.0
700
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
600
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
52
I+
II+SBY
I-SBY
RDS1
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 03 – Continued.
Symbol
ID(ON)
Test
no.
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
Terminal conditions 1/
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
OUTA
Subgroup 1
TA = 25°C
Min
Max
10 V
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
mA
“
“
“
Ω
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
15
16
17
18
19
20
21
22
23
24
25
26
27
28
A2
A1
A0
EN
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
V-
2.4 V
2.4 V
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0V
“
“
“
0.8 V
“
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0V
“
“
“
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
4.5 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
5.0 V
5.0 V
0V
0V
4.5 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V -10 V -10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V 10 V
10 V
10 V 10 V
“
“
-10 V 10 V
“
“
10 V -10 V
“
“
“
10 V -10 V
“
“
“
10 V -10 V
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
-10 V -15 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
-10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V 10 V
10 V -10 V
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
10 V
10 V
10 V
10 V
10 V
10 V
-10 V
-10 V
-10 V
-10 V
Test limits
Measured
Terminal
IN7A & OUTA
IN8A & OUTB
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN5A & OUTA
IN6A & OUTA
IN7A & OUTA
IN8A & OUTB
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
V+
VV+
V1 mA IN1A & OUTA
“
IN2A & OUTA
“
IN3A & OUTA
“
IN4A & OUTA
“
IN5A & OUTA
“
IN6A & OUTA
“
IN7A & OUTA
“
IN8A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
-1 mA IN1A & OUTA
“
IN2A & OUTA
“
IN3A & OUTA
“
IN4A & OUTA
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
-14
250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
-14
3.0
-4.0
-14
3.0
-4.0
600
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
14
3.0
-4.0
700
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
600
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
53
I+
II+SBY
I-SBY
RDS1
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 03 – Continued.
Symbol
RDS1
RDS2
RDS2
CA
CIS
54
CEN
Terminal conditions 1/
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test V+ OUTB NC IN8B IN7B IN6B IN5B IN4B IN3B IN2B IN1B GND
NC
NC
no.
101 15 V
“
102
“
“
103
“
“
104
“
“
105
“
-1 mA
-10 V
“
106
“
“
-10 V
“
107
“
“
-10 V
“
108
“
“
-10 V
“
109
“
“
-10 V
“
110
“
“
-10 V
“
111
“
“
-10 V
“
112
“
“
-10 V
“
113 thru 128 – Same terminal conditions as for tests 81 thru 96, except V± = ±10 V, VS = +7.5 V, and limits as shown.
129 thru 144 – Same terminal conditions as for tests 97 thru 112, except V± = ±10 V, VS = -7.5 V, and limits as shown.
3012
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
145 GND
146
“
147
“
148
“
149
“
150
“
151
“
152
“
153
“
154
“
155
“
156
“
157
“
158
“
159
“
160
“
161
“
162
“
163
“
164
“
165
“
166
“
5/
See footnotes at end of table.
4/
4/
4/
4/
4/
4/
4/
4/
Test limits
Measured
Terminal
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
IN5A & OUTA
IN6A & OUTA
IN7A & OUTA
IN8A & OUTB
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
A2
A1
A0
OUTA
OUTB
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
EN
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
600
“
“
“
“
“
“
“
“
“
“
“
1.0
1.0
Subgroup 4
TA = 25°C
Min
Max
10
10
10
50
50
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
700
“
“
“
“
“
“
“
“
“
“
“
1.0
1.0
600
“
“
“
“
“
“
“
“
“
“
“
1.0
1.0
Ω
“
“
“
“
“
“
“
“
“
“
“
kΩ
kΩ
pF
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
COS
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 03 – Continued.
Symbol
RDS1
RDS2
RDS2
CA
CIS
55
CEN
Terminal conditions 1/
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Test A2
A1
A0
EN IN1A IN2A IN3A IN4A IN5A IN6A IN7A IN8A
VOUTA
no.
101 2.4 V 0.8 V 0.8 V 2.4 V
-10 V
-15 V -1 mA
102
“
0.8 V 2.4 V “
-10 V
“
“
103
“
2.4 V 0.8 V “
-10 V
“
“
104
“
2.4 V 2.4 V “
-10 V
“
“
105 0.8 V 0.8 V 0.8 V “
“
106
“
0.8 V 2.4 V “
“
107
“
2.4 V 0.8 V “
“
108
“
2.4 V 2.4 V “
“
109 2.4 V 0.8 V 0.8 V “
“
110
“
0.8 V 2.4 V “
“
111
“
2.4 V 0.8 V “
“
112
“
2.4 V 2.4 V “
“
113 thru 128 – Same terminal conditions as for tests 81 thru 96, except V± = ±10 V, VS = +7.5 V, and limits as shown.
129 thru 144 – Same terminal conditions as for tests 97 thru 112, except V± = ±10 V, VS = -7.5 V, and limits as shown.
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
4/
4/
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
4/
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4/
Test limits
Measured
Terminal
4/
4/
4/
4/
4/
4/
4/
4/
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
5/
IN5A & OUTA
IN6A & OUTA
IN7A & OUTA
IN8A & OUTB
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
A2
A1
A0
OUTA
OUTB
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
EN
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
600
“
“
“
“
“
“
“
“
“
“
“
1.0
1.0
Subgroup 4
TA = 25°C
Min
Max
10
10
10
50
50
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
700
“
“
“
“
“
“
“
“
“
“
“
1.0
1.0
600
“
“
“
“
“
“
“
“
“
“
“
1.0
1.0
Ω
“
“
“
“
“
“
“
“
“
“
“
kΩ
kΩ
pF
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
COS
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 03 – Continued.
Symbol
tON(A)
and
tOFF(A)
tON(EN)
and
tOFF(EN)
MIL- Case
STD-883 X
method
Terminal conditions 1/
1
2
3
191
192
193
194
195
196
15 V
“
“
“
“
“
fig. 14
“
“
“
“
“
“
“
197
198
199
200
201
202
203
204
15 V
“
“
“
“
“
“
“
6
8
9
10
11
12
13
14
IN5B
IN4B
IN3B
IN2B
IN1B
GND
NC
NC
GND GND GND GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
-10 V
“
“
“
“
10 V
“
“
“
“
-10 V
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V -10 V -10 V -10 V -10 V
10 V 10 V 10 V 10 V 10 V
-10 V -10 V -10 V -10 V -10 V
10 V 10 V 10 V 10 V 10 V
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
ADDRESS IN
TO OUTA
“
“
“
“
“
“
ADDRESS IN
TO OUTB
“
“
“
“
“
“
ENABLE
TO OUTA
“
“
ENABLE TO
OUTB
“
“
IN
“
“
“
IN
“
“
“
IN
“
6/
6/
GND
GND
GND
“
“
“
“
“
OUTA
OUTB
OUTA
OUTB
OUTA
OUTB
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
OUTA
“
“
“
OUTB
“
“
“
IN7B IN6B
Subgroup 9
TA = 25°C
Min
Max
VISO
VCT
VCTE
tD
OUT
OUT
OUT
OUT
“
“
“
See footnotes at end of table.
IN
“
“
“
IN
“
“
“
IN
“
“
“
IN
“
“
“
“
“
IN
“
“
“
GND GND GND GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V 10 V 10 V 10 V
-10 V -10 V -10 V -10 V -10 V
10 V 10 V 10 V 10 V 10 V
-10 V -10 V -10 V -10 V -10 V
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 12
TA = 25°C
Min
Max
50
“
“
“
10
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
“
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Unit
ns
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
dB
“
“
“
mV
mV
ns
“
“
“
“
“
“
“
MIL-M-38510/190D
fig. 15
fig. 15
fig. 16
fig. 16
fig. 17
fig. 17
7
IN8B
5
56
3003
fig. 8
“
“
“
“
“
“
“
“
“
“
“
“
“
“
3003
fig. 9
“
“
“
“
“
“
Test V+ OUTB NC
no.
167 15 V
168
“
169
“
170
“
171
“
172
“
173
“
174
“
175
“
OUT
176
“
“
177
“
“
178
“
“
179
“
“
180
“
“
181
“
“
182
“
“
183
“
184
“
185
“
186
“
187
“
OUT
188
“
“
189
“
“
190
“
“
4
Test limits
Measured
Terminal
TABLE III. Group A inspection for device type 03 – Continued.
Symbol
tON(A)
and
tOFF(A)
tON(EN)
and
tOFF(EN)
MIL- Case
STD-883 X
method
Terminal conditions 1/
15
16
17
18
19
20
22
23
24
25
26
27
28
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
V-
OUTA
GND GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
GND GND GND
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
-15
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
IN
“
“
“
IN
“
“
“
IN
“
“
“
IN
“
“
“
-15 V
“
“
“
“
“
IN1A IN2A
5V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
-10 V
10 V
-10 V
10 V
GND
“
“
“
191 GND GND GND
192
“
“
“
193
“
“
“
194
“
“
“
195
IN
IN
IN
196
IN
IN
IN
0V
0V
5V
“
“
“
IN
“
6/
6/
GND
GND
197
198
199
200
201
202
203
204
5V
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
OUT ADDRESS IN
“
TO OUTA
“
“
“
“
“
“
“
“
“
“
“
“
ADDRESS IN
TO OUTB
“
“
“
“
“
“
OUT ENABLE
“
TO OUTA
“
“
“
“
ENABLE TO
OUTB
“
“
57
EN
Subgroup 9
TA = 25°C
Min
Max
VISO
VCT
VCTE
tD
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
See footnotes at end of table.
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
IN
“
“
“
IN
“
“
“
IN
“
“
“
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
GND GND GND
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
-15 V
“
“
“
“
“
“
“
OUT
OUT
OUT
OUT
“
“
“
“
“
“
“
OUTA
OUTB
OUTA
OUTB
OUTA
OUTB
OUTA
“
“
“
OUTB
“
“
“
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 12
TA = 25°C
Min
Max
50
“
“
“
10
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
“
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Unit
ns
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
dB
“
“
“
mV
mV
ns
“
“
“
“
“
“
“
MIL-M-38510/190D
21
Test A2
A1
A0
no.
167 _/¯
_/¯
_/¯
168 _/¯
_/¯
_/¯
169 ¯\_
¯\_
¯\_
170 ¯\_
¯\_
¯\_
171 _/¯
_/¯
_/¯
172 _/¯
_/¯
_/¯
173 ¯\_
¯\_
¯\_
174 ¯\_
¯\_
¯\_
175 _/¯
_/¯
_/¯
176 _/¯
_/¯
_/¯
177 ¯\_
¯\_
¯\_
178 ¯\_
¯\_
¯\_
179 _/¯
_/¯
_/¯
180 _/¯
_/¯
_/¯
181 ¯\_
¯\_
¯\_
182 ¯\_
¯\_
¯\_
183 GND GND GND
184
“
“
“
185
“
“
“
186
“
“
“
187
“
“
“
188
“
“
“
189
“
“
“
190
“
“
“
Test limits
Measured
Terminal
TABLE III. Group A inspection for device type 04.
Symbol
MIL- Case
STD-883 X
method
VIC(POS)
VIC(NEG)
IIH 2/
IIL 2/
IS(OFF)
3/
3010
“
“
“
3009
“
“
“
Terminal conditions 1/
1
2
3
4
5
See footnotes at end of table.
6
7
8
9
10
11
12
13
14
IN6B
IN5B
IN4B
IN3B
IN2B
IN1B
GND
VREF
NC
-10 V
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
10 V
10 V
-10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
10 V -10 V
-10 V
“
-10 V
“
-10 V
“
10 V 10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
-10 V 10 V
10 V
“
10 V
“
10 V
“
-10 V
“
“
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
Subgroup 1
TA = 25°C
Min
Max
A2
A1
A0
EN
A2
A1
A0
EN
A2
A1
A0
EN
A2
A1
A0
EN
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
1.5
“
“
“
-1.5
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Unit
V
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
58
Test V+ OUTB NC IN8B IN7B
no.
1
GND
2
“
3
“
4
“
5
“
6
7
8
9
15 V
10
“
11
“
12
“
13
“
14
“
15
“
16
“
17
“
-10 V -10 V
18
“
“
“
19
“
“
“
20
“
“
“
21
“
“
“
22
“
“
“
23
“
“
“
24
“
“
“
25
“
“
“
26
“
-10 V
“
“
27
“
“
“
“
28
“
“
“
“
29
“
“
“
“
30
“
“
“
“
31
“
“
“
10 V
32
“
“
10 V -10 V
33
“
10 V
“
10 V
34
“
“
“
“
35
“
“
“
“
36
“
“
“
“
37
“
“
“
“
38
“
“
“
“
39
“
“
“
“
40
“
“
“
“
41
“
“
“
“
42
“
“
“
“
43
“
“
“
“
44
“
“
“
“
45
“
“
“
“
46
“
“
“
“
47
“
“
“
-10 V
48
“
“
-10 V 10 V
Test limits
Measured
Terminal
TABLE III. Group A inspection for device type 04 – Continued.
Symbol Case
X
Terminal conditions 1/
15
VIC(POS)
VIC(NEG)
IIH 2/
IIL 2/
IS(OFF)
3/
17
18
A1
A0
EN
19
20
IN1A IN2A
21
22
23
24
25
26
27
28
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
V-
OUTA
1 mA
1 mA
1 mA
-1 mA
-1 mA
GND
4.0 V
GND
GND
5V
0.8 V
5V
5V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
-1 mA
GND 5 V
GND 5 V
4.0 V 5 V
GND 4.0 V
5V
5V
5V
5V
0.8 V 5 V
5 V 0.8 V
0.8 V 0.8 V 10 V -10 V -10 V -10 V -10 V
4.0 V
“
-10 V 10 V -10 V -10 V
“
0.8 V
“
“
-10 V 10 V -10 V
“
4.0 V
“
“
“
-10 V 10 V
“
0.8 V
“
“
“
“
-10 V 10 V
4.0 V
“
“
“
“
“
-10 V
0.8 V
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
0.8 V
“
“
10 V 10 V 10 V 10 V
4.0 V
“
10 V -10 V 10 V 10 V
“
0.8 V
“
“
10 V -10 V 10 V
“
4.0 V
“
“
“
10 V -10 V
“
0.8 V
“
“
“
“
10 V -10 V
4.0 V
“
“
“
“
“
10 V
0.8 V
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
0.8 V
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
-10 V
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
10 V
“
“
“
“
“
“
“
GND
“
“
“
-15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 1
TA = 25°C
Min
Max
A2
A1
A0
EN
A2
A1
A0
EN
A2
A1
A0
EN
A2
A1
A0
EN
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
1.5
“
“
“
-1.5
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Unit
V
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
59
Test
A2
no.
1
1 mA
2
3
4
5
-1 mA
6
7
8
9
4.0 V
10
GND
11
GND
12
GND
13
0.8 V
14
5V
15
5V
16
5V
17
0.8 V
18
“
19
“
20
“
21
4.0 V
22
“
23
“
24
“
25
0.8 V
26
“
27
“
28
“
29
4.0 V
30
“
31
“
32
“
33
0.8 V
34
“
35
“
36
“
37
4.0 V
38
“
39
“
40
“
41
0.8 V
42
“
43
“
44
“
45
4.0 V
46
“
47
“
48
“
16
Test limits
Measured
Terminal
TABLE III. Group A inspection for device type 04 – Continued.
Symbol
ID(OFF)
ID(ON)
Terminal conditions 1/
1
Test V+
no.
49 15 V
50
“
51
“
52
“
53
“
54
“
55
“
56
“
57
“
58
“
59
“
60
“
61
“
62
“
63
“
64
“
65
“
66
“
67
“
68
“
69
“
70
“
71
“
72
“
73
“
74
“
75
“
76
“
77
“
78
“
79
“
80
“
81
“
82
“
83
“
84
“
85
“
86
“
87
“
88
“
89
“
90
“
91
“
92
“
93
“
94
“
95
“
96
“
97
“
98
“
99
“
100
“
2
5
6
7
8
9
10
11
12
13
14
OUTB NC IN8B
IN7B
IN6B
IN5B
IN4B
IN3B
IN2B
IN1B
GND
VREF
NC
-10 V
10 V
10 V
-10 V
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
“
-10 V -10 V -10 V
10 V 10 V
10 V
-10 V -10 V -10 V
10 V 10 V
10 V
-10 V -10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
10 V -10 V
10 V -10 V -10 V
-10 V -10 V -10 V
10 V 10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
-10 V 10 V
-10 V 10 V
10 V
10 V 10 V
10 V
-10 V -10 V -10 V -10 V
10 V 10 V
10 V
10 V
-10 V -10 V -10 V -10 V
10 V 10 V
10 V
10 V
-10 V -10 V -10 V -10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
10 V -10 V
“
10 V -10 V
“
10 V -10 V
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
10 V
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
“
“
-10 V 10 V
“
-10 V 10 V
“
-10 V 10 V
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
See footnotes at end of table.
3
4
-10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10 V
33 V
33 V
33 V
33 V
33 V
33 V
33 V
33 V
Test limits
Measured
Terminal
OUTA
OUTA
OUTB
OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN5A & OUTA
IN6A & OUTA
IN7A & OUTA
IN8A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN5A & OUTA
IN6A & OUTA
IN7A & OUTA
IN8A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
OUTA
“
“
“
“
“
“
“
OUTB
“
“
“
“
“
“
“
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
60
ID+(OFF)
overvoltage
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 04 – Continued.
Symbol
ID(OFF)
ID(ON)
Test
no.
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
Terminal conditions 1/
15
16
17
18
19
20
21
22
23
24
25
26
27
28
A2
A1
A0
EN
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
V-
OUTA
0.8 V
“
“
“
“
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
“
“
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V 0.8 V -10 V
“
“
10 V
“
“
-10 V
“
“
10 V
“
4.0 V 10 V
4.0 V
“
-10 V
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
10 V
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V 0.8 V 33 V
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
-10 V -10 V
10 V 10 V
-10 V -10 V
10 V 10 V
-10 V -10 V
10 V -10 V
-10 V 10 V
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
-10 V 10 V
10 V -10 V
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Test limits
Measured
Terminal
-10 V -10 V -10 V -10 V -10 V
10 V 10 V
10 V
10 V
10 V
-10 V -10 V -10 V -10 V -10 V
10 V 10 V
10 V
10 V
10 V
-10 V -10 V -10 V -10 V -10 V
-10 V
“
“
“
“
-10 V
“
“
“
“
10 V
“
“
“
“
-10 V 10 V
“
“
“
“
-10 V 10 V
“
“
“
“
-10 V 10 V
“
“
“
“
-10 V 10 V
“
“
“
“
-10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
10 V
10 V
10 V
10 V
“
“
“
“
10 V
“
“
“
“
-10 V
“
“
“
“
10 V -10 V
“
“
“
“
10 V -10 V
“
“
“
“
10 V -10 V
“
“
“
“
10 V -10 V
“
“
“
“
10 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
33 V
33 V
33 V
33 V
33 V
33 V
33 V
-15 V 10 V
OUTA
“
-10 V
OUTA
“
-10 V
OUTB
“
10 V
OUTB
“
“
IN1A & OUTA
“
“
IN2A & OUTA
“
“
IN3A & OUTA
“
“
IN4A & OUTA
“
“
IN5A & OUTA
“
“
IN6A & OUTA
“
“
IN7A & OUTA
“
“
IN8A & OUTA
“
-10 V IN1B & OUTB
“
“
IN2B & OUTB
“
“
IN3B & OUTB
“
“
IN4B & OUTB
“
“
IN5B & OUTB
“
“
IN6B & OUTB
“
“
IN7B & OUTB
“
“
IN8B & OUTB
“
“
IN1A & OUTA
“
“
IN2A & OUTA
“
“
IN3A & OUTA
“
“
IN4A & OUTA
“
“
IN5A & OUTA
“
“
IN6A & OUTA
“
“
IN7A & OUTA
“
“
IN8A & OUTA
“
10 V IN1B & OUTB
“
“
IN2B & OUTB
“
“
IN3B & OUTB
“
“
IN4B & OUTB
“
“
IN5B & OUTB
“
“
IN6B & OUTB
“
“
IN7B & OUTB
“
“
IN8B & OUTB
“
0V
OUTA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
OUTB
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
61
ID+(OFF)
overvoltage
Case
X
TABLE III. Group A inspection for device type 04 – Continued.
Symbol
ID-(OFF)
overvoltage
62
Test
no.
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
Terminal conditions 1/
1
2
V+
OUTB
15 V
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
100 µA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-100 µA
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
3
4
5
NC IN8B IN7B
6
7
8
9
10
11
12
13
14
IN6B
IN5B
IN4B
IN3B
IN2B
IN1B
GND
VREF
NC
-33 V
-33 V
-33 V
-33 V
-33 V
-33 V
-33 V
-33 V
10 V
10 V
10 V
10 V
10 V
10 V
10 V
10 V
-10 V
-10 V
-10 V
-10 V
-10 V
-10 V
Test limits
Measured
Terminal
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
OUTA
“
“
“
“
“
“
“
OUTB
“
“
“
“
“
“
“
V+
VV+
VIN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN5A & OUTA
IN6A & OUTA
IN7A & OUTA
IN8A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN5A & OUTA
IN6A & OUTA
IN7A & OUTA
IN8A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
mA
“
“
“
kΩ
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-1
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-1
2.0
-1.0
-1
2.0
-1.0
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
-1.0
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
I+
II+SBY
I-SBY
RDS1
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 04 – Continued.
Symbol
ID-(OFF)
overvoltage
63
Test
no.
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
Terminal conditions 1/
Test limits
Measured
Terminal
15
16
17
18
19
20
21
22
23
24
A2
A1
A0
EN
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0V
“
“
“
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
25
26
IN7A IN8A
27
28
V-
OUTA
0.8 V 0.8 V -33 V
-15 V
4.0 V
“
-33 V
“
0.8 V
“
-33 V
“
4.0 V
“
-33 V
“
0.8 V
“
-33 V
“
4.0 V
“
-33 V
“
0.8 V
“
-33 V
“
4.0 V
“
-33 V
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0V
5V
“
“
5V
“
“
0V
“
“
0V
“
0.8 V 4.0 V 10 V
“
100 µA
4.0 V
“
10 V
“
“
0.8 V
“
10 V
“
“
4.0 V
“
10 V
“
“
0.8 V
“
10 V
“
“
4.0 V
“
10 V
“
“
0.8 V
“
10 V
“
“
4.0 V
“
10 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
-10 V
“
-100 µA
4.0 V
“
-10 V
“
“
0.8 V
“
-10 V
“
“
4.0 V
“
-10 V
“
“
0.8 V
“
-10 V
“
“
4.0 V
“
-10 V
“
“
0.8 V
“
-10 V
“
“
4.0 V
“
-10 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
0.8 V
“
“
4.0 V
“
“
OUTA
“
“
“
“
“
“
“
OUTB
“
“
“
“
“
“
“
V+
VV+
VIN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN5A & OUTA
IN6A & OUTA
IN7A & OUTA
IN8A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
IN7B & OUTB
IN8B & OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN5A & OUTA
IN6A & OUTA
IN7A & OUTA
IN8A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN5B & OUTB
IN6B & OUTB
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
mA
“
“
“
kΩ
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-1
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-1
2.0
-1.0
-1
2.0
-1.0
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
-1.0
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
I+
II+SBY
I-SBY
RDS1
Case
X
TABLE III. Group A inspection for device type 04 – Continued.
Symbol
RDS1
RDS2
RDS2
CA
COS
CIS
tON(A)
and
tOFF(A)
Terminal conditions 1/
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test V+
OUTB NC IN8B IN7B IN6B IN5B IN4B IN3B IN2B IN1B GND VREF NC
no.
151 15 V -100 µA
-10 V
GND
152 15 V -100 µA
-10 V
GND
153 thru 168 – Same terminal conditions as for tests 121 thru 136, except V± = ±10 V, VS = +7.5 V, and limits as shown.
169 thru 184 – Same terminal conditions as for tests 137 thru 152, except V± = ±10 V, VS = -7.5 V, and limits as shown.
3012
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
3003
fig. 8
“
“
“
“
“
“
“
“
“
“
“
“
“
“
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
5/
4/
4/
4/
4/
4/
4/
4/
4/
OUT
“
“
“
“
“
“
“
See footnotes at end of table.
GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
-10 V
“
10 V
“
-10 V
“
GND
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Test limits
Measured
Terminal
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 1
TA = 25°C
Min
Max
IN7B
IN8B
A2
A1
A0
OUTA
OUTB
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
EN
ADDRESS IN
TO OUTA
“
“
“
“
“
“
ADDRESS IN
TO OUTB
“
“
“
“
“
“
1.5
1.5
2.4
2.4
Subgroup 4
TA = 25°C
Min
Max
10
10
10
50
50
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 9
TA = 25°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
2.0
2.0
2.4
2.4
1.5
1.5
2.4
2.4
kΩ
kΩ
“
“
pF
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
ns
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
64
CEN
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 04 – Continued.
Symbol
RDS1
RDS2
RDS2
CA
COS
CIS
tON(A)
and
tOFF(A)
Terminal conditions 1/
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Test
A2
A1
A0
EN IN1A IN2A IN3A IN4A IN5A IN6A IN7A IN8A
V- OUTA
no.
151
152
153 thru 168 – Same terminal conditions as for tests 121 thru 136, except V± = ±10 V, VS = +7.5 V, and limits as shown.
169 thru 184 – Same terminal conditions as for tests 137 thru 152, except V± = ±10 V, VS = -7.5 V, and limits as shown.
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
4/
4/
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
See footnotes at end of table.
4/
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
0V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4/
5/
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4/
4/
4/
4/
4/
4/
4/
4/
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Test limits
Measured
Terminal
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V -15 V
-10 V
“
10 V
“
-10 V
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
5/
Subgroup 1
TA = 25°C
Min
Max
IN7B
IN8B
A2
A1
A0
OUTA
OUTB
IN1A
IN2A
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
IN1B
IN2B
IN3B
IN4B
IN5B
IN6B
IN7B
IN8B
EN
ADDRESS IN
TO OUTA
“
“
“
“
“
“
ADDRESS IN
TO OUTB
“
“
“
“
“
“
1.5
1.5
2.4
2.4
Subgroup 4
TA = 25°C
Min
Max
10
10
10
50
50
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 9
TA = 25°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
2.0
2.0
2.4
2.4
1.5
1.5
2.4
2.4
kΩ
kΩ
“
“
pF
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
ns
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
65
CEN
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 04 – Continued.
Symbol
MIL- Case
STD-883 X
method
Terminal conditions 1/
1
2
3
3003
fig. 9
“
“
“
“
“
“
VISO
fig. 15
fig. 15
fig. 16
fig. 16
fig. 17
fig. 17
231
232
233
234
235
236
15 V
“
“
“
“
“
fig. 14
“
“
“
“
“
“
“
237
238
239
240
241
242
243
244
15 V
“
“
“
“
“
“
“
VCT
VCTE
tD
OUT
OUT
66
7
8
9
10
11
12
13
14
IN5B
IN4B
IN3B
IN2B
IN1B
GND
VREF
NC
GND GND GND GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V 10 V 10 V 10 V
-10 V -10 V -10 V -10 V -10 V
10 V 10 V 10 V 10 V 10 V
-10 V -10 V -10 V -10 V -10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
ENABLE
TO OUTA
“
“
ENABLE
TO OUTB
“
“
IN
“
“
“
IN
“
“
“
IN
“
6/
6/
GND
GND
GND
“
“
“
“
“
OUTA
OUTB
OUTA
OUTB
OUTA
OUTB
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
OUTA
“
“
“
OUTB
“
“
“
IN8B
IN
“
“
“
5
6
IN7B IN6B
IN
“
“
“
IN
“
“
“
IN
“
“
“
IN
“
“
“
OUT
OUT
“
“
“
See footnotes at end of table.
GND GND GND GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V 10 V 10 V 10 V
-10 V -10 V -10 V -10 V -10 V
10 V 10 V 10 V 10 V 10 V
-10 V -10 V -10 V -10 V -10 V
Subgroup 9
TA = 25°C
Min
Max
1,000
“
“
“
“
“
“
“
Subgroup 12
TA = 25°C
Min
Max
50
“
“
“
10
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
“
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
Unit
ns
“
“
“
“
“
“
“
dB
“
“
“
mV
mV
ns
“
“
“
“
“
“
“
MIL-M-38510/190D
tON(EN)
and
tOFF(EN)
Test V+ OUTB NC
no.
223 15 V
224
“
225
“
226
“
227
“
OUT
228
“
“
229
“
“
230
“
“
4
Test limits
Measured
Terminal
TABLE III. Group A inspection for device type 04 – Continued.
Symbol
tON(EN)
and
tOFF(EN)
VISO
VCT
VCTE
Terminal conditions 1/
15
16
17
18
19
A1
A0
EN
IN1A IN2A
67
Test A2
no.
223 GND
224
“
225
“
226
“
227
“
228
“
229
“
230
“
GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
10 V
-10 V
10 V
-10 V
GND
“
“
“
231 GND
232
“
233
“
234
“
235
IN
236
IN
GND GND
“
“
“
“
“
“
IN
IN
IN
IN
0V
0V
5V
“
“
“
IN
“
6/
6/
GND
GND
5V
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
237
238
239
240
241
242
243
244
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
See footnotes at end of table.
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
20
21
22
23
24
25
26
27
28
IN3A
IN4A
IN5A
IN6A
IN7A
IN8A
V-
OUTA
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
GND GND GND
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
-15 V
“
“
“
“
“
“
“
OUT
“
“
“
“
“
“
“
ENABLE
TO OUTA
“
“
ENABLE
TO OUTB
“
“
IN
“
“
“
IN
“
“
“
IN
“
“
“
IN
“
“
“
-15 V
“
“
“
“
“
OUT
OUTA
OUTB
OUTA
OUTB
OUTA
OUTB
IN
“
“
“
IN
“
“
“
IN
“
“
“
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
GND GND GND
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
Test limits
Measured
Terminal
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
-15 V
“
“
“
“
“
“
“
OUT
OUT
OUT
“
“
“
Subgroup 9
TA = 25°C
Min
Max
OUTA
“
“
“
OUTB
“
“
“
1,000
“
“
“
“
“
“
“
Subgroup 12
TA = 25°C
Min
Max
50
“
“
“
10
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
“
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
Unit
ns
“
“
“
“
“
“
“
dB
“
“
“
mV
mV
ns
“
“
“
“
“
“
“
MIL-M-38510/190D
tD
MIL- Case
STD-883 X
method
TABLE III. Group A inspection for device type 05.
Symbol
VIC(POS)
VIC(NEG)
IIH 2/
IIL 2/
IS(OFF)
3/
Terminal conditions 1/
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A0
EN
V-
IN1
IN2
IN3
IN4
OUT
IN8
IN7
IN6
IN5
V+
GND
A2
A1
GND
“
“
“
1 mA
1mA
-1 mA
-1 mA
GND 5 V
GND
“
4.0 V
“
GND 4.0 V
5V
5V
5V
5V
0.8 V 5 V
5 V 0.8 V
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
0.8 V
“
0.8 V 4.0 V
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
GND
“
“
“
-15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
10 V
10 V
-10 V
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
10 V
10 V
-10 V
10 V
“
“
“
“
-10 V
10 V
-10 V
-10 V
10 V
-10 V
“
“
“
“
-10 V
-10 V
-10 V
10 V
-10 V
“
“
“
10 V
10 V
10 V
-10 V
10 V
“
“
“
-10 V 10 V
10 V -10 V
-10 V 10 V
-10 V
“
-10 V
“
10 V
“
-10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
Test limits
Measured
Terminal
-10 V
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
-10 V
10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
10 V
-10 V
-10 V
-10 V
“
“
“
10 V
-10 V
-10 V
-10 V
10 V
“
“
“
-10 V
10 V
10 V
10 V
-10 V
10 V
-10 V
“
“
“
10 V
-10 V
-10 V
-10 V
15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
A2
A1
A0
EN
GND -1 mA
A2
“
-1 mA
A1
“
A0
“
EN
“
4.0 V GND
A2
“
GND 4.0 V
A1
“
“
GND
A0
“
“
GND
EN
“
0.8 V
5V
A2
“
5V
0.8 V
A1
“
5V
5V
A0
“
5V
5V
EN
“
0.8 V 0.8 V
IN1
“
“
0.8 V
IN2
“
“
4.0 V
IN3
“
“
4.0 V
IN4
“
4.0 V 0.8 V
IN5
“
“
0.8 V
IN6
“
“
4.0 V
IN7
“
“
4.0 V
IN8
“
0.8 V 0.8 V
IN1
“
“
0.8 V
IN2
“
“
4.0 V
IN3
“
“
4.0 V
IN4
“
4.0 V 0.8 V
IN5
“
“
0.8 V
IN6
“
“
4.0 V
IN7
“
“
4.0 V
IN8
“
0.8 V 0.8 V
OUT
“
“
“
OUT
“
“
“
IN1 & OUT
“
“
“
IN2 & OUT
“
“
4.0 V IN3 & OUT
“
“
4.0 V IN4 & OUT
“
4.0 V 0.8 V IN5 & OUT
“
“
0.8 V IN6 & OUT
“
“
4.0 V IN7 & OUT
“
“
4.0 V IN8 & OUT
Subgroup 1
TA = 25°C
Min
Max
1 mA
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
1.5
“
“
“
1 mA
-1.5
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
Unit
V
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
68
ID(OFF)
ID(OFF)
ID(ON)
MIL- Case
STD-883 E
test
method
Test
no.
1
2
3
4
5
6
7
8
3010
9
“
10
“
11
“
12
3009
13
“
14
“
15
“
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
TABLE III. Group A inspection for device type 05 - Continued.
Symbol
See footnotes at end of table.
Test limits
Measured
Terminal
15
16
A2
A1
0.8 V
“
“
“
4.0 V
“
“
“
0V
“
“
“
GND
“
“
“
15 V
“
“
“
GND
“
“
“
15 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
“
“
“
4.0 V
“
“
“
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0V
“
“
“
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
V+
VV+
VOUT
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-10
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
mA
“
“
“
µA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
kΩ
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10
“
“
“
“
“
“
“
2.0
-1
-1
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
2.0
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.2
-1
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
2.0
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.8
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.2
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.2
MIL-M-38510/190D
69
MIL- Case
Terminal conditions 1/
STD-883 E
test
1
2
3
4
5
6
7
8
9
10
11
12
13
14
method
Test
A0
EN
VIN1
IN2
IN3
IN4
OUT
IN8
IN7
IN6
IN5
V+
GND
no.
ID(ON)
43 0.8 V 4.0 V -15 V -10 V 10 V 10 V 10 V -10 V 10 V 10 V 10 V
10 V
15 V GND
44 4.0 V
“
“
10 V -10 V 10 V 10 V
“
“
“
“
“
“
“
45 0.8 V
“
“
“
10 V -10 V 10 V
“
“
“
“
“
“
“
46 4.0 V
“
“
“
“
10 V -10 V
“
“
“
“
“
“
“
47 0.8 V
“
“
“
“
“
10 V
“
“
“
“
-10 V
“
“
48 4.0 V
“
“
“
“
“
“
“
“
“
-10 V 10 V
“
“
49 0.8 V
“
“
“
“
“
“
“
“
-10 V 10 V
10 V
“
“
50 4.0 V
“
“
“
“
“
“
“
-10 V 10 V 10 V
10 V
“
“
I+
51
0 V 5.0 V
“
“
“
I52
“
5.0 V
“
“
“
I+SBY
53
“
0V
“
“
“
I-SBY
54
“
0V
“
“
“
ID+(OFF)
55 0.8 V 0.8 V
“
33 V
0V
“
“
over56 4.0 V
“
“
33 V
“
“
“
voltage
57 0.8 V
“
“
33 V
“
“
“
58 4.0 V
“
“
33 V
“
“
“
59 0.8 V
“
“
“
33 V
“
“
60 4.0 V
“
“
“
33 V
“
“
61 0.8 V
“
“
“
33 V
“
“
62 4.0 V
“
“
“
33 V
“
“
ID-(OFF)
63 0.8 V
“
“
-33 V
“
“
“
over64 4.0 V
“
“
-33 V
“
“
“
voltage
65 0.8 V
“
“
-33 V
“
“
“
66 4.0 V
“
“
-33 V
“
“
“
67 0.8 V
“
“
“
-33 V
“
“
68 4.0 V
“
“
“
-33 V
“
“
69 0.8 V
“
“
“
-33 V
“
“
70 4.0 V
“
“
“
-33 V
“
“
RDS1
71 0.8 V 4.0 V
“
10 V
“
“
100 µA
72 4.0 V
“
“
10 V
“
“
“
73 0.8 V
“
“
10 V
“
“
“
74 4.0 V
“
“
10 V
“
“
“
75 0.8 V
“
“
“
10 V
“
“
76 4.0 V
“
“
“
10 V
“
“
77 0.8 V
“
“
“
10 V
“
“
78 4.0 V
“
“
“
10 V
“
“
79 0.8 V
“
“
-10 V
“
“
-100 µA
80 4.0 V
“
“
-10 V
“
“
“
81 0.8 V
“
“
-10 V
“
“
“
82 4.0 V
“
“
-10 V
“
“
“
83 0.8 V
“
“
“
-10 V
“
“
84 4.0 V
“
“
“
-10 V
“
“
85 0.8 V
“
“
“
-10 V
“
“
86 4.0 V
“
“
“
-10 V
“
“
RDS2 87 thru 102 – Same terminal conditions as for tests 71 thru 86, except V± = ±10 V, VS = ±7.5, and limits as shown.
TABLE III. Group A inspection for device type 05 - Continued.
Symbol
CA
COS
CIS
CEN
MIL- Case
STD-883 E
test
method
Test
no.
3012
103
“
104
“
105
“
106
“
107
“
108
“
109
“
110
“
111
“
112
“
113
“
114
“
115
3003
fig. 10
“
“
“
“
tON(EN)
and
tOFF(EN)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A0
EN
V-
IN1
IN2
IN3
IN4
OUT
IN8
IN7
IN6
IN5
V+
GND
A2
A1
GND
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
4/
0V
“
“
“
“
“
“
“
4/
GND
“
“
“
“
“
“
“
“
“
“
“
“
4/
0V
“
“
“
“
“
“
“
“
5/
4/
4/
4/
4/
4/
4/
4/
4/
3003
fig. 11
“
“
116
117
118
119
120
121
122
123
124
125
126
127
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
GND
“
“
“
5V
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
-15 V
“
“
“
“
“
“
“
“
“
“
“
VISO
VCT
VCTE
fig. 15
fig. 16
fig. 17
128
129
130
GND
GND
IN
0V
5V
5V
-15 V IN
-15 V 6/
-15 V GND
tD
fig. 14
“
“
“
131
132
133
134
_/¯
_/¯
¯\_
¯\_
5V
“
“
“
-15 V
“
“
“
See footnotes at end of table.
GND
“
“
“
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
GND GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
IN
IN
IN
IN
IN
IN
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
Test limits
Measured
Terminal
4/
0V
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
“
Unit
Subgroup 1
TA = 25°C
Min
Max
A2
A1
A0
OUT
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
EN
OUT
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
15 V
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
GND
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
GND
“
“
“
OUT
“
“
“
“
“
“
“
“
“
“
“
OUT
OUT
IN
IN
IN
IN
IN
IN
IN
IN
15 V
15 V
15 V
GND
GND
GND
GND
GND
IN
GND
GND
IN
OUT
OUT
OUT
OUT
“
“
“
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
15 V
“
“
“
GND
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
OUT
“
“
“
10
10
10
45
10
“
“
“
“
“
“
“
Subgroup 9
TA = 25°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
Subgroup 12
TA = 25°C
Min
Max
50
50
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
pF
“
“
“
“
“
“
“
“
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
ns
“
“
“
“
“
“
“
“
“
“
“
dB
dB
mV
ns
“
“
“
MIL-M-38510/190D
70
tON(A)
and
tOFF(A)
Terminal conditions 1/
TABLE III. Group A inspection for device type 06.
Symbol
VIC(POS)
VIC(NEG)
IIH 2/
IIL 2/
IS(OFF)
3/
ID(ON)
Terminal conditions 1/
1
2
3
A0
EN
V-
4
5
IN1A IN2A
6
7
8
9
10
IN3A IN4A OUTA OUTB IN4B
11
12
13
14
15
16
IN3B
IN2B
IN1B
V+
GND
A1
GND
GND
GND
1 mA
1 mA
-1 mA
-1 mA
GND 5 V
4.0 V 5 V
GND 4.0 V
5.0 V 5 V
0.8 V 5 V
5.0 V 0.8 V
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
“
“
“
“
“
“
“
4.0 V
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
0.8 V
“
4.0 V
“
GND
GND
GND
-15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
-10 V
10 V
10 V
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
-10 V
10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
10 V
10 V
-10 V
10 V
“
“
“
“
-10 V
-10 V
10 V
10 V
-10 V
-10 V
10 V
-10 V
“
“
“
“
10 V
10 V
-10 V
10 V
“
“
“
“
-10 V
-10 V
-10 V
10 V
-10 V
“
“
“
10 V
10 V
10 V
-10 V
10 V
“
“
“
-10 V
-10 V
10 V
10 V
-10 V
-10 V
-10 V
10 V
-10 V
“
“
“
10 V
10 V
10 V
-10 V
10 V
“
“
“
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
10 V
10 V
-10 V
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
“
“
“
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
-10 V
-10 V
10 V
10 V
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
Test limits
Measured
Terminal
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
10 V
-10 V
-10 V
10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
-10 V
10 V
10 V
-10 V
-10 V
10 V
10 V
-10 V
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
-10 V
10 V
10 V
-10 V
“
“
“
10 V
-10 V
-10 V
-10 V
10 V
“
“
“
-10 V
10 V
10 V
10 V
-10 V
-10 V
10 V
10 V
-10 V
“
“
“
10 V
-10 V
-10 V
-10 V
10 V
“
“
“
-10 V
10 V
10 V
10 V
15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1 mA
-1 mA
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4.0 V
GND
GND
0.8 V
5.0 V
5.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
“
“
“
“
“
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
Subgroup 1
TA = 25°C
Min
Max
A1
A0
EN
A1
A0
EN
A1
A0
EN
A1
A0
EN
IN1A
IN2A
IN3A
IN4A
IN1B
IN2B
IN3B
IN4B
IN1A
IN2A
IN3A
IN4A
IN1B
IN2B
IN3B
IN4B
OUTA
OUTB
OUTA
OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
1.5
1.5
1.5
-1.5
-1.5
-1.5
-0.1
-0.1
-0.1
-1.0
-1.0
-1.0
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
1.0
1.0
0.1
0.1
0.1
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
-0.1
-0.1
-1.0
-1.0
-1.0
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-125
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
1.0
1.0
0.1
0.1
0.1
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
125
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
-0.1
-0.1
-1.0
-1.0
-1.0
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-125
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
1.0
1.0
0.1
0.1
0.1
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
125
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Unit
V
“
“
“
“
“
µA
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
71
ID(OFF)
MIL- Case
STD-883 E
test
method
Test
no.
1
2
3
4
5
6
7
8
3010
9
“
10
“
11
“
12
3009
13
“
14
“
15
“
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
TABLE III. Group A inspection for device type 06 – Continued.
Symbol
See footnotes at end of table.
Test limits
Measured
Terminal
15
16
GND
A1
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
0V
“
“
“
0.8 V
“
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
0.8 V
0.8 V
4.0 V
4.0 V
Subgroup 1
TA = 25°C
Min
Max
V+
VV+
VOUTA
“
“
“
OUTB
“
“
“
OUTA
“
“
“
OUTB
“
“
“
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
Subgroup 2
TA = 125°C
Min
Max
2.0
-1
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.2
Unit
2.0
mA
“
“
“
µA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
kΩ
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
-1
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 3
TA = -55°C
Min
Max
-1
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.8
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.2
2.0
-1.0
-2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.0
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.5
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.2
MIL-M-38510/190D
72
MIL- Case
Terminal conditions 1/
STD-883 E
test
1
2
3
4
5
6
7
8
9
10
11
12
13
14
method
Test
A0
EN
V- IN1A IN2A IN3A IN4A OUTA OUTB IN4B IN3B IN2B IN1B V+
no.
I+
49
0 V 5.0 V -15 V
15 V
I50
“
5.0 V
“
“
I+SBY
51
“
0V
“
“
I-SBY
52
“
“
“
“
ID+(OFF)
53 0.8 V 0.8 V
“
33 V
0V
“
over54 4.0 V
“
“
33 V
“
“
voltage
55 0.8 V
“
“
33 V
“
“
56 4.0 V
“
“
33 V
“
“
57 0.8 V
“
“
0V
33 V
“
58 4.0 V
“
“
“
33 V
“
59 0.8 V
“
“
“
33 V
“
60 4.0 V
“
“
“
33 V
“
ID-(OFF)
61 0.8 V
“
“
-33 V
0V
“
over62 4.0 V
“
“
-33 V
“
“
voltage
63 0.8 V
“
“
-33 V
“
“
64 4.0 V
“
“
-33 V
“
“
65 0.8 V
“
“
0V
-33 V
“
66 4.0 V
“
“
“
-33 V
“
67 0.8 V
“
“
“
-33 V
“
68 4.0 V
“
“
“
-33 V
“
RDS1
69 0.8 V 4.0 V
“
10 V
“
100 µA
70 4.0 V
“
“
10 V
“
“
71 0.8 V
“
“
10 V
“
“
72 4.0 V
“
“
10 V
“
“
73 0.8 V
“
“
10 V
“
100 µA
74 4.0 V
“
“
“
10 V
“
75 0.8 V
“
“
“
10 V
“
76 4.0 V
“
“
“
10 V
“
77 0.8 V
“
“
-10 V
“
-100 µA
78 4.0 V
“
“
-10 V
“
“
79 0.8 V
“
“
-10 V
“
“
80 4.0 V
“
“
-10 V
“
“
81 0.8 V
“
“
-10 V
“
-100 µA
82 4.0 V
“
“
“
-10 V
“
83 0.8 V
“
“
“
-10 V
“
84 4.0 V
“
“
“
-10 V
“
RDS2 85 thru 100 – Same terminal conditions as for tests 69 thru 84, except V± = ±10 V, VS = ±7.5 V and limits as shown.
TABLE III. Group A inspection for device type 06 – Continued.
Symbol
CA
COS
CIS
CEN
tON(A)
and
tOFF(A)
3003
fig. 12
“
“
“
“
“
“
“
“
“
“
“
“
“
“
3003
fig. 13
“
“
“
“
“
“
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
Terminal conditions 1/
1
2
3
A0
EN
V-
0V
“
“
“
“
“
“
“
“
“
4/
GND
“
“
“
“
“
“
“
“
“
“
“
“
4/
0V
“
“
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
GND
“
“
“
“
“
“
“
5V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
4
5
IN1A IN2A
6
7
IN3A IN4A
8
9
OUTA
OUTB
10
11
IN4B IN3B
12
13
14
15
16
IN2B
IN1B
V+
GND
A1
GND
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
GND
4/
0V
“
“
“
“
“
“
“
“
“
“
5/
5/
4/
4/
4/
4/
4/
4/
4/
4/
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
OUT
“
“
“
“
“
“
“
OUT
“
“
“
“
“
“
“
OUT
“
“
“
OUT
“
“
“
GND
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
GND
“
“
“
10 V
-10 V
10 V
-10 V
Test limits
Measured
Terminal
GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
-10 V -10 V
10 V 10 V
-10 V -10 V
GND 15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
-10 V
“
10 V
“
-10 V
“
GND
“
“
“
“
“
“
“
10 V
“
-10 V
“
10 V
“
-10 V
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
GND
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
A0
A1
OUTA
OUTB
IN1A
IN2A
IN3A
IN4A
IN1B
IN2B
IN3B
IN4B
EN
ADDRESS IN
TO OUTA
“
“
“
“
“
“
ADDRESS IN
TO OUTB
“
“
“
“
“
“
ENABLE
TO OUTA
“
“
ENABLE
TO OUTB
“
“
Subgroup 4
TA = 25°C
Min
Max
Unit
10
10
25
25
10
“
“
“
“
“
“
“
“
Subgroup 9
TA = 25°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
pF
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
ns
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
73
tON(EN)
and
tOFF(EN)
MIL- Case
STD-883 E
test
method
Test
no.
3012
101
“
102
“
103
“
104
“
105
“
106
“
107
“
108
“
109
“
110
“
111
“
112
“
113
TABLE III. Group A inspection for device type 06 – Continued.
Symbol
VISO
VCT
VCTE
tD
MIL- Case
STD-883 E
test
1
method
Test
A0
no.
fig. 15
138 GND
fig. 15
139
“
fig. 16
140
“
fig. 16
141
“
fig. 17
142
IN
fig. 17
143
IN
fig. 14
“
“
“
“
“
“
“
144
145
146
147
148
149
150
151
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
Terminal conditions 1/
2
3
EN
V-
4
5
IN1A IN2A
0V
0V
5V
“
“
“
-15 V IN
“
“
“
6/
“
6/
“
GND
“
GND
5V
“
“
“
“
“
“
“
-15 V
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
IN
“
“
“
6
7
IN3A IN4A
IN
“
“
“
IN
“
“
“
8
9
OUTA
OUTB
OUT
OUT
OUT
OUT
10
11
IN4B IN3B
IN
“
“
“
IN
“
“
“
12
13
14
15
16
IN2B
IN1B
V+
GND
A1
IN
“
“
“
IN
“
“
“
15 V
“
“
“
GND
“
“
“
“
“
GND
“
“
“
IN
IN
OUTA
OUTB
OUTA
OUTB
OUTA
OUTB
GND 15 V
“
“
“
“
“
“
10 V
“
-10 V
“
10 V
“
-10 V
“
GND
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
OUTA
“
“
“
OUTB
“
“
“
OUT
OUT
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
GND GND GND
“
“
“
“
“
“
“
“
“
OUT
“
“
“
OUT
“
“
“
GND
“
“
“
10 V
-10 V
10 V
-10 V
Test limits
Measured
Terminal
GND GND
“
“
“
“
“
“
10 V 10 V
-10 V -10 V
10 V 10 V
-10 V -10 V
Subgroup 12
TA = 25°C
Min
Max
Unit
50
“
“
“
“
10
“
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
“
“
“
“
dB
“
“
“
mV
mV
ns
“
“
“
“
“
“
“
See footnotes at end of table.
MIL-M-38510/190D
74
TABLE III. Group A inspection for device type 07.
Symbol
IIH 2/
IIL 2/
IS(OFF)
3/
Terminal conditions 1/
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A0
EN
V-
IN1
IN2
IN3
IN4
OUT
IN8
IN7
IN6
IN5
V+
GND
A2
A1
-10 V
“
“
“
10 V
-10 V
-10 V
-10 V
10 V
“
“
“
-10 V
10 V
10 V
10 V
-10 V
10 V
-10 V
“
“
“
10 V
-10 V
-10 V
-10 V
10 V
“
“
“
-10 V
10 V
10 V
10 V
15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.4 V
GND
GND
GND
0.8 V
5V
5V
5V
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
GND
2.4 V
GND
GND
5V
0.8 V
5V
5V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
“
“
“
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
GND
GND
2.4 V
GND
5.0 V
5.0 V
0.8 V
5.0 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
0.8 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
0.8 V
2.4 V
5.0 V -15 V
5.0 V
“
5.0 V
“
4.5 V
“
5.0 V
“
“
“
“
“
0.8 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4.0 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
10 V
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
10 V
10 V
-10 V
10 V
“
“
“
“
-10 V
10 V
-10 V
-10 V
10 V
-10 V
“
“
“
“
10 V
10 V
-10 V
10 V
“
“
“
“
-10 V -10 V
-10 V
“
-10 V
“
10 V
“
-10 V
“
“
“
“
“
“
“
10 V 10 V
10 V
“
10 V
“
-10 V
“
10 V
“
“
“
“
“
“
“
-10 V 10 V
10 V -10 V
-10 V 10 V
-10 V
“
-10 V
“
10 V
“
-10 V
“
“
“
“
“
“
“
10 V -10 V
10 V
“
10 V
“
-10 V
“
10 V
“
“
“
“
“
“
“
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
-10 V
10 V
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
10 V
Test limits
Measured
Terminal
-10 V
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
-10 V
10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
-10 V
10 V
10 V
A2
A1
A0
EN
A2
A1
A0
EN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
OUT
OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-0.1
“
“
“
-1.0
“
“
“
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
“
-1.0
“
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
“
0.1
“
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
250
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
75
ID(OFF)
ID(OFF)
ID(ON)
MIL- Case
STD-883 E
test
method
Test
no.
3010
1
“
2
“
3
“
4
3009
5
“
6
“
7
“
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
TABLE III. Group A inspection for device type 07 – Continued.
Symbol
14
15
16
GND
A2
A1
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
0V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0.8 V
“
“
“
2.4 V
“
“
“
0V
“
“
“
0.8 V
“
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
Subgroup 1
TA = 25°C
Min
Max
V+
VV+
VIN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
IN1 & OUT
IN2 & OUT
IN3 & OUT
IN4 & OUT
IN5 & OUT
IN6 & OUT
IN7 & OUT
IN8 & OUT
76
CA
COS
CIS
CEN
3012
“
“
“
“
“
“
“
“
“
“
“
“
95
96
97
98
99
100
101
102
103
104
105
106
107
4/
0V
“
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
4/
GND
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
5/
4/
4/
4/
4/
4/
4/
4/
4/
Test limits
Measured
Terminal
GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4/
4/
0V
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
“
A2
A1
A0
OUT
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
EN
Subgroup 2
TA = 125°C
12
-12
3.5
400
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1,000
1,000
Subgroup 4
TA = 25°C
Min
Max
10
10
10
45
10
“
“
“
“
“
“
“
“
Unit
12
mA
“
“
“
Ω
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
12
-12
-3.5
Subgroup 3
TA = -55°C
-12
3.5
-3.5
3.5
-3.5
500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1,000
1,000
400
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1,000
1,000
pF
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
MIL- Case
Terminal conditions 1/
STD-883 E
test
1
2
3
4
5
6
7
8
9
10
11
12
13
method
Test
A0
EN
VIN1
IN2
IN3
IN4
OUT
IN8
IN7 IN6
IN5
V+
no.
I+
43
0 V 5.0 V -15 V
15 V
I44
“
5.0 V
“
“
I+SBY
45
“
0V
“
“
I-SBY
46
“
0V
“
“
RDS1
47 0.8 V 4.5 V
“
10 V
1 mA
“
48 2.4 V
“
“
10 V
“
“
49 0.8 V
“
“
10 V
“
“
50 2.4 V
“
“
10 V
“
“
51 0.8 V
“
“
“
10 V
“
52 2.4 V
“
“
“
10 V
“
53 0.8 V
“
“
“
10 V
“
54 2.4 V
“
“
“
10 V
“
55 0.8 V
“
“
-10 V
-1 mA
“
56 2.4 V
“
“
-10 V
“
“
57 0.8 V
“
“
-10 V
“
“
58 2.4 V
“
“
-10 V
“
“
59 0.8 V
“
“
“
-10 V
“
60 2.4 V
“
“
“
-10 V
“
61 0.8 V
“
“
“
-10 V
“
62 2.4 V
“
“
“
-10 V
“
RDS2 63 thru 78 – Same terminal conditions as tests 47 thru 62, except V± = ±10 V, VS = +7.5 V and limits as shown.
RDS2 79 thru 94 – Same terminal conditions as tests 47 thru 62, except V± = ±10 V, VS = -7.5 V and limits as shown.
TABLE III. Group A inspection for device type 07 – Continued.
Symbol
tON(A)
and
tOFF(A)
tON(EN)
and
tOFF(EN)
MIL- Case
STD-883 E
test
1
method
Test
A0
no.
3003
108
_/¯
fig. 10
109
_/¯
“
110
¯\_
“
111
¯\_
“
112
_/¯
“
113
_/¯
“
114
¯\_
“
115
¯\_
3003
116 GND
fig. 11
117
“
“
118
“
“
119
“
Terminal conditions 1/
3
4
5
6
7
8
9
10
11
12
13
14
15
16
EN
V-
IN1
IN2
IN3
IN4
OUT
IN8
IN7
IN6
IN5
V+
GND
A2
A1
5V
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
-15 V
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
OUT
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
15 V
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
GND
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
GND
“
“
“
OUT
“
“
“
“
“
“
“
“
“
“
“
OUT
OUT
OUT
IN
IN
IN
IN
15 V
15 V
15 V
GND
GND
GND
GND
GND
IN
GND
GND
IN
OUT
OUT
OUT
OUT
“
“
“
10 V
-10 V
10 V
-10 V
10 V
-10 V
10 V
-10 V
15 V
“
“
“
GND
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
OUT
“
“
“
VISO
VCT
VCTE
fig. 15
fig. 16
fig. 17
120
121
122
GND
GND
IN
0V
5V
5V
-15 V IN
-15 V 6/
-15 V GND
tD
fig. 14
“
“
“
123
124
125
126
_/¯
_/¯
¯\_
¯\_
5V
“
“
“
-15 V
“
“
“
See footnotes at end of table.
10 V
-10 V
10 V
-10 V
IN
IN
IN
IN
IN
IN
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
-10 V -10 V
10 V 10 V
-10 V -10 V
IN
IN
IN
IN
10 V 10 V
-10 V -10 V
10 V 10 V
-10 V -10 V
Subgroup 9
TA = 25°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
Subgroup 12
TA = 25°C
Min
Max
50
50
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
Subgroup 10
TA = 125°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
Subgroup 11
TA = -55°C
Min
Max
1,000
“
“
“
“
“
“
“
“
“
“
“
Unit
ns
“
“
“
“
“
“
“
“
“
“
“
dB
dB
mV
ns
“
“
“
MIL-M-38510/190D
77
2
GND GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
Test limits
Measured
Terminal
TABLE III. Group A inspection for device type 08.
Symbol
IIH 2/
IIL 2/
IS(OFF)
3/
78
ID(ON)
Terminal conditions 1/
1
2
3
A0
EN
V-
GND GND -15 V
2.4 V GND
“
GND 4.5 V
“
5V
5V
“
0.8 V 5 V
“
5.0 V 0.8 V
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
“
“
“
“
“
“
“
“
“
“
4.0 V
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
0.8 V
“
“
2.4 V
“
“
See footnotes at end of table.
4
5
IN1A IN2A
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
-10 V
10 V
10 V
10 V
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
-10 V
10 V
10 V
-10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
6
7
8
9
10
IN3A IN4A OUTA OUTB IN4B
-10 V
-10 V
10 V
-10 V
“
“
“
“
10 V
10 V
-10 V
10 V
“
“
“
“
-10 V
-10 V
10 V
10 V
-10 V
-10 V
10 V
-10 V
“
“
“
“
10 V
10 V
-10 V
10 V
“
“
“
“
-10 V
-10 V
-10 V
10 V
-10 V
“
“
“
10 V
10 V
10 V
-10 V
10 V
“
“
“
-10 V
-10 V
10 V
10 V
-10 V
-10 V
-10 V
10 V
-10 V
“
“
“
10 V
10 V
10 V
-10 V
10 V
“
“
“
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
-10 V
“
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
10 V
10 V
-10 V
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
“
“
“
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
-10 V
-10 V
-10 V
10 V
10 V
-10 V
“
“
“
“
“
“
10 V
“
“
“
“
“
“
“
10 V
Test limits
Measured
Terminal
11
12
13
14
15
16
IN3B
IN2B
IN1B
V+
GND
A1
-10 V
“
“
“
10 V
-10 V
-10 V
-10 V
10 V
“
“
“
-10 V
10 V
10 V
10 V
-10 V
-10 V
10 V
10 V
-10 V
“
“
“
10 V
-10 V
-10 V
-10 V
10 V
“
“
“
-10 V
10 V
10 V
10 V
15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
2.4 V
GND
GND
0.8 V
5V
5V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
“
“
“
“
“
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
10 V
-10 V
-10 V
10 V
10 V
-10 V
“
“
“
“
“
10 V
-10 V
10 V
“
“
“
“
“
-10 V
10 V
-10 V
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
-10 V
10 V
10 V
-10 V
-10 V
10 V
10 V
-10 V
“
“
“
“
10 V
-10 V
-10 V
10 V
“
“
“
“
-10 V
10 V
10 V
A1
A0
EN
A1
A0
EN
IN1A
IN2A
IN3A
IN4A
IN1B
IN2B
IN3B
IN4B
IN1A
IN2A
IN3A
IN4A
IN1B
IN2B
IN3B
IN4B
OUTA
OUTB
OUTA
OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
Subgroup 1
TA = 25°C
Min
Max
Subgroup 2
TA = 125°C
Min
Max
Subgroup 3
TA = -55°C
Min
Max
Unit
-0.1
“
“
-1.0
“
“
-1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
-1.0
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-125
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-0.1
“
“
-1.0
“
“
-50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
-125
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
µA
“
“
“
“
“
nA
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
0.1
“
“
1
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
0.1
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
125
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1.0
“
“
0.1
“
“
50
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
125
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
ID(OFF)
MIL- Case
STD-883 E
test
method
Test
no.
3010
1
“
2
“
3
“
4
3009
5
“
6
“
7
“
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
TABLE III. Group A inspection for device type 08 – Continued.
Symbol
79
CA
COS
CIS
CEN
3012
“
“
“
“
“
“
“
“
“
“
“
“
79
80
81
82
83
84
85
86
87
88
89
90
91
4/
0V
“
“
“
“
“
“
“
“
“
0V
“
“
“
“
“
“
“
“
“
4/
GND
“
“
“
“
“
“
“
“
“
“
“
“
See footnotes at end of table.
5/
5/
4/
4/
4/
4/
4/
4/
4/
4/
GND
“
“
“
“
“
“
“
“
“
“
“
“
Test limits
Measured
Terminal
15
16
GND
A1
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
0V
“
“
“
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
0.8 V
0.8 V
2.4 V
2.4 V
GND
“
“
“
“
“
“
“
“
“
“
“
“
4/
0V
“
“
“
“
“
“
“
Subgroup 1
TA = 25°C
Min
Max
V+
VV+
VIN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
IN1A & OUTA
IN2A & OUTA
IN3A & OUTA
IN4A & OUTA
IN1B & OUTB
IN2B & OUTB
IN3B & OUTB
IN4B & OUTB
A0
A1
OUTA
OUTB
IN1A
IN2A
IN3A
IN4A
IN1B
IN2B
IN3B
IN4B
EN
Subgroup 2
TA = 125°C
12
-12
3.5
400
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1,000
Subgroup 4
TA = 25°C
Min
Max
10
10
25
25
10
“
“
“
“
“
“
“
“
Unit
12
mA
“
“
“
Ω
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
12
-12
-3.5
Subgroup 3
TA = -55°C
-12
3.5
-3.5
3.5
-3.5
500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1,000
400
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1,000
pF
“
“
“
“
“
“
“
“
“
“
“
“
MIL-M-38510/190D
MIL- Case
Terminal conditions 1/
STD-883 E
test
1
2
3
4
5
6
7
8
9
10
11
12
13
14
method
Test
A0
EN
V- IN1A IN2A IN3A IN4A OUTA OUTB IN4B IN3B IN2B IN1B V+
no.
I+
43
0 V 5.0 V -15 V
15 V
I44
“
5.0 V
“
“
I+SBY
45
“
0V
“
“
I-SBY
46
“
0V
“
“
RDS1
47 0.8 V 4.5 V
“
10 V
1 mA
“
48 2.4 V
“
“
10 V
“
“
49 0.8 V
“
“
10 V
“
“
50 2.4 V
“
“
10 V
“
“
51 0.8 V
“
“
1 mA
10 V
“
52 2.4 V
“
“
“
10 V
“
53 0.8 V
“
“
“
10 V
“
54 2.4 V
“
“
“
10 V
“
55 0.8 V
“
“
-10 V
-1 mA
“
56 2.4 V
“
“
-10 V
“
“
57 0.8 V
“
“
-10 V
“
“
58 2.4 V
“
“
-10 V
“
“
59 0.8 V
“
“
-1 mA
-10 V
“
60 2.4 V
“
“
“
-10 V
“
61 0.8 V
“
“
“
-10 V
“
62 2.4 V
“
“
“
-10 V
“
RDS2 63 thru 78 – Same terminal conditions as tests 47 thru 62, except V± = ±10 V, VS = ±7.5 V and limits as shown.
TABLE III. Group A inspection for device type 08 – Continued.
Symbol
tON(A)
and
tOFF(A)
tON(EN)
and
tOFF(EN)
Terminal conditions 1/
2
3
EN
V-
5V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
-15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
4
5
6
7
8
9
OUTA
OUTB
IN1A IN2A
IN3A IN4A
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
OUT
“
“
“
“
“
“
“
IN
“
“
“
IN
“
“
“
IN
“
“
“
OUT
OUT
“
“
“
“
“
“
“
OUT
“
“
“
OUT
“
“
“
10
11
IN4B IN3B
GND
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
12
13
14
15
16
IN2B
IN1B
V+
GND
A1
GND 15 V
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V
“
-10 V
“
10 V
“
-10 V
“
GND
“
“
“
“
“
“
“
10 V
“
-10 V
“
10 V
“
-10 V
“
GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
GND
“
“
“
“
“
“
“
ADDRESS IN
TO OUTA
“
“
“
“
“
“
ADDRESS IN
TO OUTB
“
“
“
“
“
“
ENABLE
TO OUTA
“
“
ENABLE
TO OUTB
“
“
IN
“
6/
6/
GND
GND
15 V
“
“
“
“
“
GND
“
“
“
“
“
GND
“
“
“
IN
IN
OUTA
OUTB
OUTA
OUTB
OUTA
OUTB
GND 15 V
“
“
“
“
“
“
10 V
“
-10 V
“
10 V
“
-10 V
“
GND
“
“
“
“
“
“
“
IN
“
“
“
“
“
“
“
OUTA
“
“
“
OUTB
“
“
“
GND GND
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
10 V 10 V
-10 V -10 V
10 V 10 V
-10 V -10 V
Subgroup 9
TA = 25°C
Min
Max
80
VISO
VCT
VCTE
tD
fig. 15
fig. 15
fig. 16
fig. 16
fig. 17
fig. 17
116
117
118
119
120
121
GND
“
“
“
IN
IN
0V
0V
5V
“
“
“
-15 V IN
“
“
“
6/
“
6/
“
GND
“
GND
fig. 14
“
“
“
“
“
“
“
122
123
124
125
126
127
128
129
_/¯
_/¯
¯\_
¯\_
_/¯
_/¯
¯\_
¯\_
5V
“
“
“
“
“
“
“
-15 V
“
“
“
“
“
“
“
10 V
-10 V
10 V
-10 V
GND
“
“
“
OUT
OUT
OUT
IN
“
“
“
IN
“
“
“
IN
“
“
“
OUT
OUT
10 V 10 V 10 V
-10 V -10 V -10 V
10 V 10 V 10 V
-10 V -10 V -10 V
GND GND GND
“
“
“
“
“
“
“
“
“
OUT
“
“
“
OUT
“
“
“
GND
“
“
“
10 V
-10 V
10 V
-10 V
Test limits
Measured
Terminal
GND GND
“
“
“
“
“
“
10 V 10 V
-10 V -10 V
10 V 10 V
-10 V -10 V
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Subgroup 12
TA = 25°C
Min
Max
50
“
“
“
10
10
Subgroup 13
TA = 25°C
Min
Max
5
“
“
“
“
“
“
“
Subgroup 10
TA = 125°C
Min
Max
Subgroup 11
TA = -55°C
Min
Max
1,500
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
1/ Pins not designated may be high-level logic or open. Exceptions are as follows: VIC(POS) tests, the V-, GND terminal shall be open; VIC(NEG) tests, the V+
terminal shall be open.
2/ The device manufacturer may, at his option, measure IIL and IIH at 25°C for each individual input or measure all inputs together.
3/ The IS and ID measurements shall be performed in sequence.
4/ CA, CEN, and CIS – Connect capacitance bridge between measured terminal and VSS, frequency = 1 MHz, see 4.4.1c.
5/ COS – Connect capacitance bridge between measured output and VSS, frequency = 1 MHz, see 4.4.1c.
6/ Connect input to ground through a 1 kΩ ±5% resistor.
1,000
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
Unit
ns
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
dB
“
“
“
mV
ns
“
“
“
“
“
“
“
MIL-M-38510/190D
MIL- Case
STD-883 E
test
1
method
Test
A0
no.
3003
92
_/¯
fig. 12
93
_/¯
“
94
¯\_
“
95
¯\_
“
96
_/¯
“
97
_/¯
“
98
¯\_
“
99
¯\_
“
100
_/¯
“
101
_/¯
“
102
¯\_
“
103
¯\_
“
104
_/¯
“
105
_/¯
“
106
¯\_
“
107
¯\_
fig. 13
108 GND
“
109
“
“
110
“
“
111
“
“
112
“
“
113
“
“
114
“
“
115
“
MIL-M-38510/190D
4.4.1 Group A inspection. Group A inspection shall be in accordance with table III of MIL-PRF-38535 and as follows:
a.
Tests shall be as specified in table II herein.
b.
Subgroups 5, 6, 7, and 8 of method 5005 of MIL-STD-883 shall be omitted.
c.
Subgroup 4 (Ci measurements) shall be measured only for initial qualification and after process or design changes
which may affect input capacitance. Capacitance shall be measured between the designated terminal and GND at a
frequency of 1 MHz. Subgroup 4 shall be performed using a sample of 5 devices with no failures allowed.
d.
Subgroup 13 shall be added to group A inspection for all classes and it shall consist of the tests, conditions and limits
as specified in table III. The sample size series shall be 10 for all classes (accept on 0).
e.
Subgroup 12 shall be performed for initial qualification only using a sample of 5 devices for each device type submitted
to group A inspections with no failures allowed. If not more than 1 failure is found in the first sample of 5, a second
sample of 5 is permitted with no further failures allowed.
4.4.2 Group B inspection. Group B inspection shall be in accordance with table II of MIL-PRF-38535.
4.4.3 Group C inspection. Group C inspection shall be in accordance with table IV of MIL-PRF-38535 and as follows:
a.
End point electrical parameters shall be as specified in table II herein.
b.
The steady-state life test duration, test condition, and test temperature, or approved alternatives shall be as
specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be
maintained under document control by the device manufacturer's Technology Review Board (TRB) in accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test
method 1005 of MIL-STD-883.
c.
A special subgroup shall be added to the group C inspection requirements for class B devices, and shall consist of the
tests, conditions, and limits as specified for subgroups 10 and 11 of group A.
d.
A special subgroup shall be added to group C inspection for class B devices only and it shall consist of group A,
subgroup 12 as specified in table III herein. This special subgroup shall be performed on each device type that is
qualified from those listed in 1.2.1 herein. After initial qualification, the special subgroup shall be performed periodically
on a single device type selected from those device types previously qualified. A sample of 5 devices (of the device
type to be inspected) shall be chosen and submitted to test with no failures allowed. If not more than 1 failure is found
in the first sample of 5, a second sample of 5 is permitted with no further failures allowed. When more than one device
type is qualified, the single device type selected shall be a different device for each subsequent periodic inspection until
all qualified device types have been inspected. The sequence of single device types shall be repeated to fulfill the
periodic inspection requirement.
4.4.4 Group D inspection. Group D inspection shall be in accordance with table V of MIL-PRF-38535.
a.
End point electrical parameters shall be as specified in table II herein.
b.
A special subgroup shall be added to group D inspection for class S devices only and it shall consist of group A,
subgroups 4 and 7 as specified in table III herein. This special subgroup shall be performed on each device type that is
qualified from those listed in 1.2.1 herein. After initial qualification, the special subgroup shall be performed periodically
on a single device type selected from those device types previously qualified. When more than one device type is
qualified, the single device type selected shall be a different device for each subsequent periodic inspection until all
qualified device types have been inspected. The sequence of single device types shall be repeated to fulfill the
periodic inspection requirement.
4.5 Methods of inspection. Methods of inspection shall be specified and as follows.
4.5.1 Voltage and current. All voltage values given are referenced to the microcircuit ground terminals. Currents given are
conventional current and positive when flowing into the referenced terminal.
81
MIL-M-38510/190D
4.6 Data reporting. When specified in the acquisition document, a copy of the following data, as applicable, shall be applied:
a.
Attributes data for all screening tests (see 4.2) and variables data for all static burn-in, dynamic burn-in, and
operating life tests.
b.
The technology conformance inspection data (see 4.4).
Table IV. Group C end-point electrical parameters. TA = 25°C
Parameter
RON
ID(OFF)
IS(OFF)
01, 07
50 Ω or 10% 1/
15 nA
15 nA
02
150 Ω or 10%
15 nA
15 nA
Device types
03, 08
04
50 Ω or 10%
150 Ω or 10%
15 nA
15 nA
15 nA
15 nA
05
150 Ω or 10% 1/
15 nA
15 nA
06
150 Ω or 10% 1/
15 nA
15 nA
1/ Whichever is greater.
2/ Each of the above parameters shall be recorded before and after the required burn-in or life tests to determine deltas (∆).
5. PACKAGING
5.1 Packaging requirements. For acquisition purposes, the packaging requirements shall be as specified in the contract or
order (see 6.2). When packaging of materiel is to be performed by DoD personnel, these personnel need to contact the
responsible packaging activity to ascertain requisite packaging requirements. Packaging requirements are maintained by the
Inventory Control Point’s packaging activity within the Military Department of Defense Agency, or within the Military
Department’s System Command. Packaging data retrieval is available from the managing Military Department’s or Defense
Agency’s automated packaging files, CD-ROM products, or by contacting the responsible packaging activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)
6.1 Intended use. Microcircuits conforming to this specification are intended for logistic support of existing equipment.
6.2 Acquisition requirements. Acquisition documents should specify the following:
a.
Title, number, and date of the specification.
b.
PIN and compliance identifier, if applicable (see 1.2).
c.
Requirements for delivery of one copy of the conformance inspection data pertinent to the device
inspection lot to be supplied with each shipment by the device manufacturer, if applicable.
d.
Requirements for certificate of compliance, if applicable.
e.
Requirements for notification of change of product or process to acquiring activity in addition to
notification of the qualifying activity, if applicable.
f.
Requirements for failure analysis (including required test condition of MIL-STD-883, method 5003),
corrective action and reporting of results, if applicable.
g.
Requirements for product assurance options.
h.
Requirements for special carriers, lead lengths, or lead forming, if applicable. These requirements should not
affect the part number. Unless otherwise specified, these requirements will not apply to direct purchase by
or direct shipment to the Government.
i.
Requirements for “JAN” marking.
j.
Packaging requirements (see 5.1).
82
MIL-M-38510/190D
6.3 Qualification. With respect to products requiring qualification, awards will be made only for products which are, at the
time of award of contract, qualified for inclusion in Qualified Manufacturers List QML-38535 whether or not such products have
actually been so listed by that date. The attention of the contractors is called to these requirements, and manufacturers are
urged to arrange to have the products that they propose to offer to the Federal Government tested for qualification in order that
they may be eligible to be awarded contracts or purchase orders for the products covered by this specification. Information
pertaining to qualification of products may be obtained from DSCC-VQ, 3990 E. Broad Street, Columbus, Ohio 43123-1199.
6.4 Superseding information. The requirements of MIL-M-38510 have been superseded to take advantage of the
available Qualified Manufacturer Listing (QML) system provided by MIL-PRF-38535. Previous references to MIL-M-38510 in
this document have been replaced by appropriate references to MIL-PRF-38535. All technical requirements now consist of this
specification and MIL-PRF-38535. The MIL-M-38510 specification sheet number and PIN have been retained to avoid
adversely impacting existing government logistics systems and contractor's parts lists.
6.5 Abbreviations, symbols, and definitions. The abbreviations, symbols, and definitions used herein are defined in
MIL-PRF-38535 and MIL-HDBK-1331 and as follows:
VIC
IIL
IIH
IS(OFF)
ID(OFF)
ID(ON)
I(+)
I(-)
I(SBY)
RON
CA
COS
CIS
CIOS
tPLH
tPHL
GND
VREF
A
EN
O/I
I/O
................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
.................................................
Input clamp voltage.
Low level (address) input current.
High level (address) input current.
Leakage current into the source terminal of an “OFF” switch.
Leakage current into the drain terminal of an “OFF” switch.
Leakage current from an “ON” driver into the switch.
Positive supply current.
Negative supply current.
Standby supply current.
Resistance of an “ON” switch.
Address capacitance.
Output switch capacitance.
Input switch capacitance.
Input to output (feedthrough) capacitance.
Propagation delay time: low to high level.
Propagation delay time: high to low level.
Electrical ground.
Reference voltage.
Address input to switch.
Enable.
Output/Input.
Input/Output.
6.6 Logistic support. Lead materials and finishes (see 3.4) are interchangeable. Unless otherwise specified, microcircuits
acquired for Government logistic support will be acquired to device class B (see 1.2.2), lead material and finish A (see 3.4).
Longer length leads and lead forming should not affect the part number.
83
MIL-M-38510/190D
6.7 Substitutability. The cross-reference information below is presented for the convenience of users. Microcircuits covered
by this specification will functionally replace the listed generic-industry type. Generic-industry microcircuit types may not have
equivalent operational performance characteristics across military temperature ranges or reliability factors equivalent to MIL-M38510 device types and may have slight physical variations in relation to case size. The presence of this information should not
be deemed as permitting substitution of generic-industry types for MIL-M-38510 types or as a waiver of any of the provisions of
MIL-PRF-38535.
Military device type
01
02
03
04
05
06
07
08
Generic-industry type
506, 6116
506A
507, 6216
507A
508A
509A
508, 6108
509, 6208
6.8 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the
previous issue, due to the extensiveness of the changes.
Custodians:
Army – CR
Navy - EC
Air Force - 11
NASA – NA
DLA – CC
Preparing activity:
DLA - CC
Project 5962-2125
Review activities:
Army – MI, SM
Navy – AS, CG, MC, SH, TD
Air Force – 03, 19, 99
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and
responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at
http://assist.daps.dla.mil .
84