Family data sheet

Product family datasheet
POWERTRONIC PT-FIT S
ECG for HID lamps, for installation in luminaires
Areas of application
_ Shop lighting
_ Health and fitness areas (in dry, corrosion-protected
place)
_ Effect and accent lighting
__
Product benefits
_ Optimized cost/benefit factor
_ Compact dimensions and low weight for small luminaire designs
_ Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL)
Product features
_ Energy Efficiency Index EEI: A2
_ Supply voltage: 220…240 V
_ Line frequency: 50…60 Hz
_ RI suppression: to EN 55015/CISPR 15
_ Safety: to EN 61347-2-12
_ Line harmonics according to EN 61000-3-2
_ Immunity according to EN 61547
June 8, 2016, 04:38:57
POWERTRONIC PT-FIT S
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 7
Product family datasheet
Technical data
Electrical data
__
Product description
Lamp
wattage
Line
current
Ignition voltage
Operating
frequency
System
wattage
ECG
efficiency
PT-FIT 35/220…240 S
39 W
0.19 A 1)
4.5 kVp
0.200…0.240 kHz
43.00 W
92 %
PT-FIT 50/220…240 S
50 W
0.24 A
1)
4.5 kVp
0.200…0.240 kHz
54.50 W
92 %
PT-FIT 70/220…240 S
73 W
0.36 A 1)
4.5 kVp
0.200…0.240 kHz
80.00 W
92 %
Product description
Input voltage
AC
Nominal
voltage
Mains
frequency
Power factor λ
Inrush
current
Max. ECG no.
on circuit
breaker 10 A
(B)
PT-FIT 35/220…240 S
198…264 V
220…240 V
50…60 Hz
0.95
2)
30 A 3)
15
PT-FIT 50/220…240 S
198…264 V
220…240 V
50…60 Hz
0.95
2)
45 A 5)
7
4)
2)
5)
7
4)
PT-FIT 70/220…240 S
198…264 V
220…240 V
50…60 Hz
0.95
Product description
Max. ECG no.
on circuit
breaker 16 A
(B)
U-OUT
(working
voltage)
Max.
working
voltage
between
LH and LL
Max.
working
voltage
betw.
LL/LH &
earth
Max.
capacitance
of wire
ECG/lamp
PT-FIT 35/220…240 S
26
4)
250 V
250 V
250 V
120 pF
PT-FIT 50/220…240 S
13
4)
250 V
250 V
250 V
120 pF
13
4)
250 V
250 V
250 V
120 pF
PT-FIT 70/220…240 S
45 A
4)
1) At 230 V
AC
2) Minimum
3) t
= 150 µs (measured at 50 % I
)
5) t
= 250 µs (measured at 50 % I
)
width
4) Type B
width
peak
peak
Dimensions & weight
Product description
Length
Width
Height
Mounting
hole
spacing,
length
Mounting
hole
spacing,
width
Cable crosssection, input
side
PT-FIT 35/220…240 S
110.0 mm
75.0 mm
30.0 mm
99.0 mm
64.0 mm
0.5…1.0 /
0.5…1.5 mm² 1)
PT-FIT 50/220…240 S
110.0 mm
75.0 mm
30.0 mm
99.0 mm
64.0 mm
0.5…1.0 /
0.5…1.5 mm² 1)
PT-FIT 70/220…240 S
110.0 mm
75.0 mm
30.0 mm
99.0 mm
64.0 mm
0.5…1.0 /
0.5…1.5 mm² 1)
Product description
Cable crosssection, output
side
Wire preparation
length, input side
Wire preparation
length, output side
Product
weight
PT-FIT 35/220…240 S
0.5…1.0 /
0.5…1.5 mm² 1)
8.5…9.5 mm
8.5…9.5 mm
245.00 g
June 8, 2016, 04:38:57
POWERTRONIC PT-FIT S
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 7
Product family datasheet
Product description
Cable crosssection, output
side
Wire preparation
length, input side
Wire preparation
length, output side
Product
weight
PT-FIT 50/220…240 S
0.5…1.0 /
0.5…1.5 mm² 1)
8.5…9.5 mm
8.5…9.5 mm
250.00 g
PT-FIT 70/220…240 S
0.5…1.0 /
0.5…1.5 mm² 1)
8.5…9.5 mm
8.5…9.5 mm
250.00 g
1) With ferrule
Product line drawing
__
PT-FIT 35/220…240 S, PT-FIT 50/220…240 S, PT-FIT
70/220…240 S
Colors & materials
Product description
Casing material
PT-FIT 35/220…240 S
Metal
PT-FIT 50/220…240 S
Metal
PT-FIT 70/220…240 S
Metal
June 8, 2016, 04:38:57
POWERTRONIC PT-FIT S
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 7
Product family datasheet
Temperatures & operating conditions
Product description
Ambient
temperature range
Maximum
temperature at tc
test point
PT-FIT 35/220…240 S
-15…+65 °C
85 °C
PT-FIT 50/220…240 S
-15…+60 °C
85 °C
PT-FIT 70/220…240 S
-15…+55 °C
85 °C
Lifespan
Product description
ECG lifetime
PT-FIT 35/220…240 S
30000 h 1)
PT-FIT 50/220…240 S
30000 h 1)
PT-FIT 70/220…240 S
30000 h 1)
1) At maximum T / 10% failure rate
c
Additional product data
__
Product description
Design / version
PT-FIT 35/220…240 S
Built-in unit
PT-FIT 50/220…240 S
Built-in unit
PT-FIT 70/220…240 S
Built-in unit
Capabilities
Product description
Max. cable
length to
lamp/LED
module
Overheating protection
ECG
reset
time
Dimmable
Restriction on
ignition time
PT-FIT 35/220…240 S
1.5 m
Power reduction and
switch off at T > 85 °C at
the tc point
> 0.5 s
No
20 min
PT-FIT 50/220…240 S
1.5 m
Power reduction and
switch off at T > 85 °C at
the tc point
> 0.5 s
No
20 min
PT-FIT 70/220…240 S
1.5 m
Power reduction and
switch off at T > 85 °C at
the tc point
> 0.5 s
No
20 min
Product description
Suitable for fixtures
with prot. class
PT-FIT 35/220…240 S
I
PT-FIT 50/220…240 S
I
PT-FIT 70/220…240 S
I
June 8, 2016, 04:38:57
POWERTRONIC PT-FIT S
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 7
Product family datasheet
Certificates & standards
Product description
Approval marks – approval
Type of
protection
EEI –
Energy
Label
PT-FIT 35/220…240 S
VDE / VDE-EMC / EAC / C-Tick
IP20
A2
PT-FIT 50/220…240 S
VDE / VDE-EMC / EAC / C-Tick
IP20
A2
PT-FIT 70/220…240 S
VDE / VDE-EMC / EAC / C-Tick
IP20
A2
Product description
Standards
PT-FIT 35/220…240 S
Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to
EN 61547
PT-FIT 50/220…240 S
Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to
EN 61547
PT-FIT 70/220…240 S
Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to
EN 61547
Wiring Diagram
__
PT-FIT 35/220…240 S, PT-FIT 50/220…240 S, PT-FIT
70/220…240 S
Safety advice
Ballast losses and lamp heat radiation can lead to heat accumulation in a completely closed case. Therefore it is necessary to
ensure that the temperature at the measuring point t of the ECG does not exceed the maximum value.
June 8, 2016, 04:38:57
POWERTRONIC PT-FIT S
© 2016, OSRAM GmbH. All rights reserved.
Page 5 of 7
Product family datasheet
Attention!
For safety reasons disconnect the device before replacing the lamp!
Application advice
For more detailed application information and graphics please see product datasheet.
Sales and Technical Support
Sales and Technical Support www.osram.com
Country specific information
Product description
Product code
METEL code
SEG number
STK-Number
UK Org
PT-FIT 35/220…240
S
4008321386625
OSRPTFIT35S
7980553
-
-
PT-FIT 50/220…240
S
4008321648693
-
7980555
-
-
PT-FIT 70/220…240
S
4008321386649
OSRPTFIT70S
7980557
-
-
__
Download Data
File
Tender documents
Tender Document for POWERTRONIC EVG.eng
Certificates
EMC-Marks approval
Certificates
VDE-Marks approval
Certificates
EAC PT family
Declarations of conformity
Declaration of conformity
Installation/Operation notice
Technical guide - POWERTRONIC for HID-lamps (GB)
Operating instructions
EAC - PTI S PT-FIT S
Product Datasheet
PT-FIT 50220-240 S: technical information
June 8, 2016, 04:38:57
POWERTRONIC PT-FIT S
© 2016, OSRAM GmbH. All rights reserved.
Page 6 of 7
Product family datasheet
Logistical Data
Product code
Product description
Packaging unit (Pieces/Unit)
Dimensions (length x width x
height)
Volume
Gross weight
4008321386625
PT-FIT 35/220…240 S
Shipping carton box
20
412 mm x 136 mm x 152 mm
8.52 dm³
5169.89 g
4008321648693
PT-FIT 50/220…240 S
Shipping carton box
20
412 mm x 152 mm x 136 mm
8.52 dm³
5170.00 g
4008321386649
PT-FIT 70/220…240 S
Shipping carton box
20
412 mm x 136 mm x 152 mm
8.52 dm³
5269.89 g
The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or
more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit.
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.