Product family datasheet POWERTRONIC PT-FIT S ECG for HID lamps, for installation in luminaires Areas of application _ Shop lighting _ Health and fitness areas (in dry, corrosion-protected place) _ Effect and accent lighting __ Product benefits _ Optimized cost/benefit factor _ Compact dimensions and low weight for small luminaire designs _ Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL) Product features _ Energy Efficiency Index EEI: A2 _ Supply voltage: 220…240 V _ Line frequency: 50…60 Hz _ RI suppression: to EN 55015/CISPR 15 _ Safety: to EN 61347-2-12 _ Line harmonics according to EN 61000-3-2 _ Immunity according to EN 61547 June 8, 2016, 04:38:57 POWERTRONIC PT-FIT S © 2016, OSRAM GmbH. All rights reserved. Page 1 of 7 Product family datasheet Technical data Electrical data __ Product description Lamp wattage Line current Ignition voltage Operating frequency System wattage ECG efficiency PT-FIT 35/220…240 S 39 W 0.19 A 1) 4.5 kVp 0.200…0.240 kHz 43.00 W 92 % PT-FIT 50/220…240 S 50 W 0.24 A 1) 4.5 kVp 0.200…0.240 kHz 54.50 W 92 % PT-FIT 70/220…240 S 73 W 0.36 A 1) 4.5 kVp 0.200…0.240 kHz 80.00 W 92 % Product description Input voltage AC Nominal voltage Mains frequency Power factor λ Inrush current Max. ECG no. on circuit breaker 10 A (B) PT-FIT 35/220…240 S 198…264 V 220…240 V 50…60 Hz 0.95 2) 30 A 3) 15 PT-FIT 50/220…240 S 198…264 V 220…240 V 50…60 Hz 0.95 2) 45 A 5) 7 4) 2) 5) 7 4) PT-FIT 70/220…240 S 198…264 V 220…240 V 50…60 Hz 0.95 Product description Max. ECG no. on circuit breaker 16 A (B) U-OUT (working voltage) Max. working voltage between LH and LL Max. working voltage betw. LL/LH & earth Max. capacitance of wire ECG/lamp PT-FIT 35/220…240 S 26 4) 250 V 250 V 250 V 120 pF PT-FIT 50/220…240 S 13 4) 250 V 250 V 250 V 120 pF 13 4) 250 V 250 V 250 V 120 pF PT-FIT 70/220…240 S 45 A 4) 1) At 230 V AC 2) Minimum 3) t = 150 µs (measured at 50 % I ) 5) t = 250 µs (measured at 50 % I ) width 4) Type B width peak peak Dimensions & weight Product description Length Width Height Mounting hole spacing, length Mounting hole spacing, width Cable crosssection, input side PT-FIT 35/220…240 S 110.0 mm 75.0 mm 30.0 mm 99.0 mm 64.0 mm 0.5…1.0 / 0.5…1.5 mm² 1) PT-FIT 50/220…240 S 110.0 mm 75.0 mm 30.0 mm 99.0 mm 64.0 mm 0.5…1.0 / 0.5…1.5 mm² 1) PT-FIT 70/220…240 S 110.0 mm 75.0 mm 30.0 mm 99.0 mm 64.0 mm 0.5…1.0 / 0.5…1.5 mm² 1) Product description Cable crosssection, output side Wire preparation length, input side Wire preparation length, output side Product weight PT-FIT 35/220…240 S 0.5…1.0 / 0.5…1.5 mm² 1) 8.5…9.5 mm 8.5…9.5 mm 245.00 g June 8, 2016, 04:38:57 POWERTRONIC PT-FIT S © 2016, OSRAM GmbH. All rights reserved. Page 2 of 7 Product family datasheet Product description Cable crosssection, output side Wire preparation length, input side Wire preparation length, output side Product weight PT-FIT 50/220…240 S 0.5…1.0 / 0.5…1.5 mm² 1) 8.5…9.5 mm 8.5…9.5 mm 250.00 g PT-FIT 70/220…240 S 0.5…1.0 / 0.5…1.5 mm² 1) 8.5…9.5 mm 8.5…9.5 mm 250.00 g 1) With ferrule Product line drawing __ PT-FIT 35/220…240 S, PT-FIT 50/220…240 S, PT-FIT 70/220…240 S Colors & materials Product description Casing material PT-FIT 35/220…240 S Metal PT-FIT 50/220…240 S Metal PT-FIT 70/220…240 S Metal June 8, 2016, 04:38:57 POWERTRONIC PT-FIT S © 2016, OSRAM GmbH. All rights reserved. Page 3 of 7 Product family datasheet Temperatures & operating conditions Product description Ambient temperature range Maximum temperature at tc test point PT-FIT 35/220…240 S -15…+65 °C 85 °C PT-FIT 50/220…240 S -15…+60 °C 85 °C PT-FIT 70/220…240 S -15…+55 °C 85 °C Lifespan Product description ECG lifetime PT-FIT 35/220…240 S 30000 h 1) PT-FIT 50/220…240 S 30000 h 1) PT-FIT 70/220…240 S 30000 h 1) 1) At maximum T / 10% failure rate c Additional product data __ Product description Design / version PT-FIT 35/220…240 S Built-in unit PT-FIT 50/220…240 S Built-in unit PT-FIT 70/220…240 S Built-in unit Capabilities Product description Max. cable length to lamp/LED module Overheating protection ECG reset time Dimmable Restriction on ignition time PT-FIT 35/220…240 S 1.5 m Power reduction and switch off at T > 85 °C at the tc point > 0.5 s No 20 min PT-FIT 50/220…240 S 1.5 m Power reduction and switch off at T > 85 °C at the tc point > 0.5 s No 20 min PT-FIT 70/220…240 S 1.5 m Power reduction and switch off at T > 85 °C at the tc point > 0.5 s No 20 min Product description Suitable for fixtures with prot. class PT-FIT 35/220…240 S I PT-FIT 50/220…240 S I PT-FIT 70/220…240 S I June 8, 2016, 04:38:57 POWERTRONIC PT-FIT S © 2016, OSRAM GmbH. All rights reserved. Page 4 of 7 Product family datasheet Certificates & standards Product description Approval marks – approval Type of protection EEI – Energy Label PT-FIT 35/220…240 S VDE / VDE-EMC / EAC / C-Tick IP20 A2 PT-FIT 50/220…240 S VDE / VDE-EMC / EAC / C-Tick IP20 A2 PT-FIT 70/220…240 S VDE / VDE-EMC / EAC / C-Tick IP20 A2 Product description Standards PT-FIT 35/220…240 S Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61547 PT-FIT 50/220…240 S Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61547 PT-FIT 70/220…240 S Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61547 Wiring Diagram __ PT-FIT 35/220…240 S, PT-FIT 50/220…240 S, PT-FIT 70/220…240 S Safety advice Ballast losses and lamp heat radiation can lead to heat accumulation in a completely closed case. Therefore it is necessary to ensure that the temperature at the measuring point t of the ECG does not exceed the maximum value. June 8, 2016, 04:38:57 POWERTRONIC PT-FIT S © 2016, OSRAM GmbH. All rights reserved. Page 5 of 7 Product family datasheet Attention! For safety reasons disconnect the device before replacing the lamp! Application advice For more detailed application information and graphics please see product datasheet. Sales and Technical Support Sales and Technical Support www.osram.com Country specific information Product description Product code METEL code SEG number STK-Number UK Org PT-FIT 35/220…240 S 4008321386625 OSRPTFIT35S 7980553 - - PT-FIT 50/220…240 S 4008321648693 - 7980555 - - PT-FIT 70/220…240 S 4008321386649 OSRPTFIT70S 7980557 - - __ Download Data File Tender documents Tender Document for POWERTRONIC EVG.eng Certificates EMC-Marks approval Certificates VDE-Marks approval Certificates EAC PT family Declarations of conformity Declaration of conformity Installation/Operation notice Technical guide - POWERTRONIC for HID-lamps (GB) Operating instructions EAC - PTI S PT-FIT S Product Datasheet PT-FIT 50220-240 S: technical information June 8, 2016, 04:38:57 POWERTRONIC PT-FIT S © 2016, OSRAM GmbH. All rights reserved. Page 6 of 7 Product family datasheet Logistical Data Product code Product description Packaging unit (Pieces/Unit) Dimensions (length x width x height) Volume Gross weight 4008321386625 PT-FIT 35/220…240 S Shipping carton box 20 412 mm x 136 mm x 152 mm 8.52 dm³ 5169.89 g 4008321648693 PT-FIT 50/220…240 S Shipping carton box 20 412 mm x 152 mm x 136 mm 8.52 dm³ 5170.00 g 4008321386649 PT-FIT 70/220…240 S Shipping carton box 20 412 mm x 136 mm x 152 mm 8.52 dm³ 5269.89 g The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit. Disclaimer Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release. __ June 8, 2016, 04:38:57 POWERTRONIC PT-FIT S © 2016, OSRAM GmbH. All rights reserved. Page 7 of 7