Photosensor amplifier C6386-01 Light-to-voltage conversion amplifier with optical fiber Features Applications Easy handling Optical power meters Built-in photodiode allows easy detection of light just by connecting to a voltmeter. Laser monitors Optical fiber light input Measures light at a narrow detection point. Separating the amplifier from the detection point allows measurement in unusual environments and achieves low noise. Precision photometry Various light detection (sparks inside equipment, etc.) Three sensitivity ranges Range Conversion impedance (V/A) Cutoff frequency (MHz) 5 H 10 M 104 1 3 L 103 10 High-speed response Absolute maximum ratings (Ta=25 °C unless otherwise noted) Parameter Supply voltage Operating temperature Optical fiber usage temperature Minimum bending radius for optical fiber Symbol Condition Vs Topr No dew condensation*1 No dew condensation*1 - Value ±18 0 to +40 0 to +60 Unit V °C °C R15 mm *1: When there is a temperature difference between a product and the surrounding area in high humidity environment, dew condensation may occur on the product surface. Dew condensation on the product may cause deterioration in characteristics and reliability. Note: Exceeding the absolute maximum ratings even momentarily may cause a drop in product quality. Always be sure to use the product within the absolute maximum ratings. Recommended operating range Parameter Supply voltage Symbol Vs Condition Min. ±6 www.hamamatsu.com Typ. - Max. ±15 Unit V 1 Photosensor amplifier C6386-01 Specifications (Ta=25 °C, Vs=±15 V, ±9 V using integrated dry batteries) Parameter Fiber diameter Numerical aperture Symbol H M L Photosensitivity*2 Output resistance Condition λ=830 nm Measured when light is input to the optical fiber end. S - Output voltage amplitude Vs=±15 V, RL=2 kΩ Vs=±9 V, RL=2 kΩ Dark state, all bandwidth VFS Output noise Vn H M L Frequency bandwidth*3 f Battery lifetime - Current consumption Weight *2: Refer to spectral response. *3: Refer to frequency response. IS - -3 dB With dry batteries dark state, RL > 10 kΩ Dark state Including batteries Spectral response Min. +10 +5 DC DC DC Typ. ϕ2.0 0.56 30 3 0.3 200 1 3 10 Max. 10 - Unit mm - - 90 - hr - 460 ±7 - mA g mV/μW Ω V mVp-p MHz Frequency response (Typ. Ta=25 °C) 100 (Typ. Ta=25 °C) 106 10 M range Output (V/A) Photosensitivity (mV/μW) H range 1 L range 0.1 0.01 300 400 10 5 H range 104 M range 103 L range 2 500 600 700 800 900 1000 1100 1200 Wavelength (nm) 10 100 kHz 1 MHz 10 MHz 100 MHz Frequency KACCB0041EC KACCB0042EB 2 Photosensor amplifier C6386-01 Dimensional outline (unit: mm) Output (BNC-R) External power supply input 90 ± 1 Input (1/4-36UNS) Pilot lamp Power supply switch Zero adjustment control Rf change switch 115 ± 1 ON Rf RANGE ZERO ADJ. H 40 ± 1 POWER M L PHOTOSENSOR AMP. C6386-01 KACCA0020EC Connection example Optical fiber A9511* Measurement light BNC cable E2573* (1 m) Power cable* (50 cm) Readout device (e.g., oscilloscope) Input terminal impedance 1 MΩ or more (Red) +15 V (Black) GND (Blue) -15 V * Accessories Dual power supply (±6 to ±15 V, 0.1 A or more) Be sure to use a dual power supply. Switching power supplies are not supported. Use a series power supply (ripple voltage: 3 mVp-p or less). KACCC0882EA 3 Photosensor amplifier C6386-01 Accessories (unit: mm) SMA type connector (1/4-36UNS) Nylon tube ɸ5.1 ± 0.4 · Instruction manual · Dry battery (built into the unit) · Optical fiber A9511 (provided also as a replacement accessory) Tip part (aluminum alloy) 17 ± 0.5 20 ± 0.5 ɸ5.0 ± 0.4 ɸ2.0 1000 ± 20 KACCA0141EB · Power cable 500 ± 50 Connector HR10A-7P-4S (Hirose, 4-pin, female) KACCC0823EA Options (unit: mm) · BNC cable E2573 Cable: 1.5D-QEV +50 1000 - 0 Related information KACCA0334EA www.hamamatsu.com/sp/ssd/doc_en.html Precautions ∙ Disclaimer Information described in this material is current as of June, 2016. Product specifications are subject to change without prior notice due to improvements or other reasons. This document has been carefully prepared and the information contained is believed to be accurate. In rare cases, however, there may be inaccuracies such as text errors. Before using these products, always contact us for the delivery specification sheet to check the latest specifications. The product warranty is valid for one year after delivery and is limited to product repair or replacement for defects discovered and reported to us within that one year period. However, even if within the warranty period we accept absolutely no liability for any loss caused by natural disasters or improper product use. Copying or reprinting the contents described in this material in whole or in part is prohibited without our prior permission. www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Solid State Division 1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184 U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J. 08807, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 8152-375-0, Fax: (49) 8152-265-8 France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10 United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777 North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01 Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39) 02-93581733, Fax: (39) 02-93581741 China: Hamamatsu Photonics (China) Co., Ltd.: B1201, Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86) 10-6586-6006, Fax: (86) 10-6586-2866 Cat. No. KACC1101E03 Jun. 2016 DN 4