Accessories for infrared detector Temperature controllers Heatsinks for TE-cooled detector Chopper, etc. Wide lineups of accessories for infrared detector HAMAMATSU provides temperature controllers, heatsinks for TE-cooled detector, chopper and cables, etc as accessories for infrared detectors. Connection example of accessories for infrared detectors *1 Power supply (±15 V) Chopper C4696 TE-cooled detector*3 *2 POWER OUT Measuring instrument Amplifier for infrared detector*4 C4159 series, C5185-02 Heatsink for TE-cooled detector A3179 series Power supply (100 V, 115 V, 230 V) ûC GND +12 V POWER CHOPPER TRIG *3 Chopper driver circuit (accessory of the C4696) Temperature controller C1103 series Power supply (+12 V) KACCC0321ED *1: Attach the bare wire ends to a 3-pin or 4-pin connector or to a banana jack, and then connect them to the power supply. *2: Soldering is needed. When using the C5185-02 amplifier, a BNC connector (prepared by the user, example: one end of the E2573) is required. *3: No socket is available. Soldering is needed. *4: Refer to the datasheet “Amplifiers for infrared detectors” for detailed information. Note: Refer to page 6 for details on cables. www.hamamatsu.com 1 Temperature controllers, heatsinks for TE-cooled detector, chopper, etc. Accessories for infrared detector Temperature controllers C1103 series The C1103 series is a temperature controller designed for thermoelectrically cooled infrared detectors. The C1103 series allows easy but accurate temperature setting for the thermoelectric cooler mounted in an infrared detector. Specifications Parameter C1103-04 C1103-05 C1103-07 One-stage/two-stage TE-cooled type Two-stage/three-stage TE-cooled type One-stage TE-cooled type Applicable detector*5 InAsSb, InAs photovoltaic detector, InSb photoconductive detector InSb photoconductive detector InGaAs, Si photodiode Setting element temperature -30 to +20 °C -75 to -25 °C -30 to +20 °C Temperature stability Within ±0.1 °C Output current for temperature control 1.1 A min., 1.2 A typ., 1.3 A max. Power supply 100 V ± 10 % · 50/60 Hz*6 Power consumption 30 W Dimensions 107 (W) × 84 (H) × 190 (D) mm Weight 1.9 kg approx. Instruction manual Accessories 4-conductor cable (with a connector, 3 m) A4372-05*7, power supply cable *5: It doesn't correspond to TE-cooled type infrared detector module with preamp. *6: Please specify power supply requirement (AC line voltage) from among 100 V, 115 V and 230 V when ordering. *7: When used in combination with an A3179 series heatsink, do not use the 4-conductor cable supplied with the A3179 series, but use the A4372-05 instead. Absolute maximum ratings Parameter Operating temperature Operating humidity Storage temperature Value +10 to +40 °C 90% Max.*8 -20 to +40 °C *8: No dew condensation When there is a temperature difference between a product and the surrounding area in high humidity environment, dew condensation may occur on the product surface. Dew condensation on the product may cause deterioration in characteristics and reliability. Note: Exceeding the absolute maximum ratings even momentarily may cause a drop in product quality. Always be sure to use the product within the absolute maximum ratings. Block diagram C1103 series TE-cooled detector Thermistor Comparator Amp circuit Current circuit TE-cooled element Power supply AC input KIRDC0008EB 2 Temperature controllers, heatsinks for TE-cooled detector, chopper, etc. Accessories for infrared detector Heatsinks for TE-cooled detector (TO-8, TO-3 package) A3179 series These heatsinks are designed for use with thermoelectrically cooled detector sealed in a 6-pin TO-8, TO-3 package. The cooling (heat dissipation) capacity of the A3179 and A3179-03 is about 35 °C relative to the ambient temperature 25 °C, the A3179-01 is about 40 °C, and that of the A3179-04 is about 85 °C. The A3179-03 is designed only for two-color detector K3413 series, the A3179, A3179-01 for TO-8, the A3179-04 for TO-3 (heatsink for TO-66 is available as a custom product.) . Accessories *9: When used in combination with a C1103 series temperature controller, do not use the 4-conductor cable supplied with the A3179 series, but use the 4-conductor cable A4372-05 (sold separately, with a connector). *10: No socket is supplied for connection to infrared detectors. Connect infrared detectors by soldering. Cover the soldered joints and detector pins with vinyl insulating tubes. Instruction manual 4-conductor cable (2 m): for TE-cooler and thermistor*9, *10 Coaxial cable (2 m): for signal*10 Dimensional outlines (unit: mm, tolerance unless otherwise noted: ±0.3) A3179 ϕ32 3 3 ϕ46 0.4 ± 0.3*2 ϕ26 ± 0.2 *1 Photosensitive surface*3 Detector metal package 32 (4 ×) ϕ3.5 ϕ40 60° 32.6 Weight: 50 g approx. *1: Bottom surface (reference surface) of detector metal package *2: When the detector is installed *3: The position of the photosensitive surface differs according to the detector used. Refer to the dimensional outline for the detector. KIRDA0018ED 3 Temperature controllers, heatsinks for TE-cooled detector, chopper, etc. Accessories for infrared detector A3179-01, A3179-03 (4 ×) ϕ3.5 32 ϕ40 ϕ46 ϕ32 3 Photosensitive surface*3 Detector metal package 0.4 ± 0.3*2 ϕ26 ± 0.2 *1 B 60° 36 A3179-01: B=6 A3179-03: B=6.4 Weight: 53 g approx. *1: Bottom surface (reference surface) of detector metal package *2: When detector is installed *3: The position of the photosensitive surface differs according to the detector used. Refer to the dimensional outline for the detector. KIRDA0019ED 3 ± 0.5 A3179-04 Fixation board 40 56 1 + 0 Photosensitive surface 79. ϕ1 ϕ38 ± 0.5 (4 ×) ϕ3.5 ± 0.5 56 6.7 ± 0.5 68 45 80 Weight: 320 g approx. KIRDA0149EB 4 Temperature controllers, heatsinks for TE-cooled detector, chopper, etc. Accessories for infrared detector Chopper C4696 Specifications Parameter Chopping frequency*11 Power supply (VD) Duty ratio Rotational stability Min. Synchronous signal (high level) Max. Operating temperature Maximum current consumption*12 Accessory Specification 115 to 380 Hz, 345 Hz typ.*12 DC 5 to 13 V, 12 V typ. 1:1 0.06 %/°C VD - 0.5 V VD - 0.2 V 0 to 50 °C 90 mA Magnet stand A1447 *11: Chopping frequency will be 230 to 760 Hz when an optional disc is used. *12: VD=12 V Dimensional outline (unit: mm, tolerance unless otherwise noted: ±1) <Chopper> Output window ϕ8.0 19 Input window ϕ4.0 23.0 45.0 202.3 to 272.3 (adjustable) 8 ϕ8 A1447 (Magnet stand) 6-pin receptacle cord length: 2 m (For connection to driver circuit) <Driver circuit> 38.5 COUNTER 13.5 12.5 25 37 GND +12 V ON-OFF TRIG BNC 18 12.5 17.5 85 30 60 6-pin connector KIRDA0022EA 5 Accessories for infrared detector Temperature controllers, heatsinks for TE-cooled detector, chopper, etc. Chopping frequency vs. operating voltage (Typ.) 800 Chopping frequency (Hz) 700 600 500 When used with optional disk 400 300 200 C4696 100 0 2 4 6 8 10 12 14 Operating voltage (V) KIRDB0376EA Cables A4372 series Cable No. Cable Length approx. Coaxial cable (for signal) 2m 4-conductor cable (with a connector) A4372-05 3m 4-conductor cable (with a connector) A4372-02 2m BNC connector cable E2573 Power supply cable (for temperature controller) Chopper driver cable (connected to chopper) 2-conductor cable or coaxial cable (for chopper power supply) 1m 1.9 m 2m 2 m or less Note Supplied with heatsink A3179 series. When using this cable, make it as short as possible (preferably about 10 cm). Supplied with temperature controller C1103 series. This cable is also sold separately. This cable is supplied with the C4159 series, C5185-02 amplifiers for infrared detector, and infrared detector modules with preamp (room temperature operation type). This cable is also sold separately. Besides this cable, the A437203, which is a 6-conductor cable (with connector) supplied with “infrared detector module with preamp”, is also sold separately. Option Supplied with temperature controller C1103 series Connected to chopper Prepared by user 6 Accessories for infrared detector Temperature controllers, heatsinks for TE-cooled detector, chopper, etc. Magnet stand A1447 This is a magnet stand (sold separately) designed for the B749 photon drag detector. Dimensional outline (unit: mm, tolerance unless otherwise noted: ±1) 1/4-20UNC 100 49.5 160 min. 230 max. 5.5 ϕ20 KIRDA0017EA 7 Temperature controllers, heatsinks for TE-cooled detector, chopper, etc. Accessories for infrared detector Valve operator for metal dewar A3515 With this valve operator, metal dewars can be re-evacuated to maintain the desired vacuum level. Refer to the instruction manual for details. Please be aware that the detector performance is not guaranteed after re-evacuation is performed with the valve operator. Vacuum pump Metal dewar type infrared detector Valve operator Dimensional outline (unit: mm) Pump tube ϕ9.5 ± 0.5 Leak mount Gland nut O-ring Knob 80.0 ± 1 (close) 115.0 ± 1 (open) KIRDA0021EC Related information www.hamamatsu.com/sp/ssd/doc_en.html Precautions ∙ Disclaimer Technical information ∙ Infrared detector Information described in this material is current as of November, 2015. Product specifications are subject to change without prior notice due to improvements or other reasons. This document has been carefully prepared and the information contained is believed to be accurate. In rare cases, however, there may be inaccuracies such as text errors. Before using these products, always contact us for the delivery specification sheet to check the latest specifications. The product warranty is valid for one year after delivery and is limited to product repair or replacement for defects discovered and reported to us within that one year period. However, even if within the warranty period we accept absolutely no liability for any loss caused by natural disasters or improper product use. Copying or reprinting the contents described in this material in whole or in part is prohibited without our prior permission. www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Solid State Division 1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184 U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J. 08807, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 8152-375-0, Fax: (49) 8152-265-8 France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10 United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777 North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01 Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39) 02-93581733, Fax: (39) 02-93581741 China: Hamamatsu Photonics (China) Co., Ltd.: B1201, Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86) 10-6586-6006, Fax: (86) 10-6586-2866 Cat. No. KACC1062E15 Nov. 2015 DN 8