Level measurement CleverLevel® LBFS Point level detection Product highlights Save detection of liquids, bulk-solids and powders Short immersion length Excellent cleanability Ability for differentiation between foam and liquid Not sensitive to adherent or sticky media Status signaling by bright, blue LED Compact stainless steel housing, sealed up to IP69K User benefits One sensor for all applications Less disturbance of process Safe process with less downtime Visual observation of process Long life time even in wash-down areas TYPE EL - Class I DECEMBER 2012 Technical data Housing Style Dimension Material Reverse polarity protection Compact design Refer to dimensional drawings (page 4 f.) Switching polarity M12, 4 pin, polycarbonate M12, 4 pin, stainless steel 5 m, 4-wire, PVC Ambient conditions Humidity (IEC 68-2-38) Protection class (IEC 60529) Vibration -40 ... 85 °C -40 ... 85 °C Yes PNP: (+Vs -1.5 V) ± 0.5 V, Rload = 10 kΩ NPN: (+1.5 V) ± 0.5 V, Rload = 10 kΩ Off leak current Switching logic ± 100 μA max. Normally open (NO) Normally closed (NC) Sensor performance < 98 % RH, condensing IP67 IP69K (with appropriate cable) IEC 60068-2-6 GL Test 2 Repeatability ± 1 mm Hysteresis Response time Damping ± 1 mm 0.1 s typ. (0.15 ± 0.05 s) 0.0 ... 10.0 s (adjustable) Factory settings Mounting position Wetted parts material Refer to dimensional drawings (page 4 f.) Any (top, bottom, side) PEEK Natura AISI 316L (1.4404) AISI 304 (1.4301) (optional) Ra < 0.8 μm Process conditions Process temperature Process pressure Switching range (dielectric constant DC) Damping Refer to table (page 2 f.) 12 ... 30 V DC 25 mA typ., 50 mA max. < 75 % (DC > 2) 0.1 s Compliance and approvals EMC Immunity EMC Emission Explosion protection EN 61326 EN 61326 (installed on a metal tank) ATEX II 1 G Ex ia IIC T4/T5 ATEX II 1 D Ex ta IIIC T100 °C Da ATEX II 3 G Ex nA II T4/T5 Refer to table (page 2 f.) Power supply www.baumer.com 20 mA max. Current consumption (no load) Voltage drop Connection variants Voltage supply range Process connection Surface roughness wetted parts Short circuit protection Safety Hygiene Railway Marine Note: cULus Listed, Class 2, E365692 Refer to table (page 3) EN 50155 Refer to table (page 3) Information on product characteristics may relate to defined product options. Data sheet CleverLevel® LBFS Page 1 / 10 Design and specifications subject to change without notice Storage temperature range Current rating EN/13052016 Operating temperature range PNP NPN Cable outlet <2s Output signalization Stainless steel Electrical connection Connector variants Power-up time Yes Level measurement CleverLevel® LBFS Point level detection Process conditions Type Process connection Process temperature continuous Tamb < 50 °C Process pressure Process temperature max. temporary t < 1 h Tamb < 50 °C Process pressure @ Process temperature max. temporary LBFS-xx1xx.x G 1/2 A ISO 228-1 BCID °C bar °C bar G07 -40 … 115 -1 … 100 135 -1 … 100 LBFS-xxGxx.x G 1/2 A ISO 228-1 with cooling neck, not applicable for mounting with ZPW1-7x1 G07 -40 … 150 -1 … 100 N/A N/A LBFS-xxAxx.x G 1/2 A DIN 3852-E, NBR gasket G51 -40 … 115 -1 … 100 135 -1 … 100 LBFS-xxBxx.x G 1/2 A DIN 3852-E, FKM (Viton®) gasket G51 -40 … 115 -1 … 100 135 -1 … 100 LBFS-xx4xx.x G 1/2 A hygienic A03 -40 … 115 -1 … 10 135 -1 … 5 LBFS-xxKxx.x G 1/2 A hygienic, length 82 mm A03 -40 … 115 -1 … 10 135 -1 … 5 LBFS-xxLxx.x G 1/2 A hygienic, sliding connection, length 250 mm A03 -40 … 200 -1 … 5 N/A N/A LBFS-xx5xx.x G 1/2 A ISO 228-1 for reverse assembly (in-shell thread) T10 -40 … 85 -1 … 100 135 -1 … 100 LBFS-xx2xx.x G 3/4 A ISO 228-1 G10 -40 … 115 -1 … 100 135 -1 … 100 LBFS-xx3xx.x G 1 A ISO 228-1 G11 -40 … 115 -1 … 100 135 -1 … 100 LBFS-xxNxx.x 1/2-14 NPT N02 -40 … 115 -1 … 100 135 -1 … 100 LBFS-xxMxx.x 1/2-14 NPT with cooling neck N02 -40 … 150 -1 … 100 N/A N/A LBFS-xx6xx.x 3/4-14 NPT N03 -40 … 115 -1 … 100 135 -1 … 100 LBFS-xx7xx.x M18x1 M11 -40 … 115 N/A N/A N/A Process connection type 1, 2, 3, 4, 5, 6, 7, A, B, G, K, M, N Process connection type L (sliding connection) 150 140 130 120 110 100 200 25 35 50 65 90 145 190 20 35 45 65 90 140 With cooling neck (type G, M) 180 20 30 45 60 85 140 170 20 25 40 55 85 135 160 25 35 55 80 130 150 20 25 50 75 130 140 20 30 45 75 125 130 25 45 70 120 120 20 40 65 115 110 20 25 60 110 30 55 105 25 50 100 20 45 95 70 35 85 60 35 65 60 65 90 90 80 No limitation 100 80 50 60 70 80 90 35 Ambient temperature (°C) 40 45 50 55 Design and specifications subject to change without notice Projecting length min. (mm) Without cooling neck Process temperature (°C) Process temperature max.(°C) 160 Ambient temperature (°C) 15 min. Projecting length 15 ... 228 34 15 34 15 EN/13052016 228 max. www.baumer.com Data sheet CleverLevel® LBFS Page 2 / 10 Level measurement CleverLevel® LBFS Point level detection Compliance and approvals Type Process connection BCID LBFS-xx1xx.x G 1/2 A ISO 228-1 G07 LBFS-xxGxx.x G 1/2 A ISO 228-1 with cooling neck G07 LBFS-xxAxx.x G 1/2 A DIN 3852-E, NBR gasket LBFS-xxBxx.x EN 1935/2004 EN 10/2011 EN 2023/2006 FDA 3-A EHEDG EL-Class I DNV GL G51 G 1/2 A DIN 3852-E, FKM (Viton®) gasket G51 LBFS-xx4xx.x G 1/2 A hygienic A03 LBFS-xxKxx.x G 1/2 A hygienic, length 82 mm A03 LBFS-xxLxx.x G 1/2 A hygienic, sliding connection, length 250 mm A03 LBFS-xx5xx.x G 1/2 A ISO 228-1 for reverse assembly (in-shell thread) T10 LBFS-xx2xx.x G 3/4 A ISO 228-1 G10 LBFS-xx3xx.x G 1 A ISO 228-1 G11 LBFS-xxNxx.x 1/2-14 NPT N02 LBFS-xxMxx.x 1/2-14 NPT with cooling neck N02 LBFS-xx6xx.x 3/4-14 NPT LBFS-xx7xx.x M18x1 Lloyd‘s Register CCS WHG (overfill, leakage) N03 M11 Note: Information on product characteristics may relate to defined product options. The requirements of the respective 3-A Sanitary Standard will be only fulfilled in combination with appropriate mounting accessories. Those are marked with the 3-A logo. The EHEDG certification is only valid in combination with appropriate mounting accessories. Those are marked with the "EHEDG Certified" logo. ATEX II 1 G Ex ia IIC T4/T5 ATEX II 1 D Ex ta IIIC T100 °C Da Maximun values (for barrier selection) (1) Voltage supply range Temperature class Internal capacitance Ci: 43 nF Internal inductance Temperature class Li: 10 µH T1…T4: -40 < Tamb < 85 °C T1…T5: -40 < Tamb < 74 °C Protection class of cable accessory 30 V DC max. Design and specifications subject to change without notice Ui: 30 V DC Ii: 100 mA Pi: 0.75 W T100 °C: -40 < Tamb < 85 °C IP67 ATEX II 3 G Ex nA II T4/T5 Voltage supply range 30 V DC max. Temperature class T1…T4: -40 < Tamb < 85 °C T1…T5: -40 < Tamb < 74 °C EN/13052016 (1) Recommended barrier: PROFSI3-B25100-ALG-LS (please refer to accessories, page 10) www.baumer.com Data sheet CleverLevel® LBFS Page 3 / 10 Level measurement CleverLevel® LBFS Point level detection Field of application CleverLevel® LBFS is designed for level detection in tanks and dry-run protection of pumps by empty pipe monitoring. It detects liquid, pasty or oily media, but also solid-bulk materials like flour or plastic granulate. The LBFS is capable of media differentiation by distinguishing the specific properties, such as oil, water, foam and liquid. Reliable performance is assured in any mounting position (from top, bottom or side). Depending on the desired process connection, different mounting options are available. Corresponding mounting aids and adaptors for conventional process connections are available as an accessory. Two parallel switching outputs are available as Normally Open (NO) and Normally Closed (NC) which is defined by PNP or NPN polarity when placing the order. CleverLevel® LBFS in its default configuration covers a major part of potential applications. Where customer-specific configuration is required because of difficult media (e. g. foamy or adhering), the interface programming tool FlexProgrammer 9701 allows for easy parameterization of the optimum switching points by convenient teach-in functionality. The measured data can be visualized on a PC for further parameter adjustment, for example time constant of a damping function and inverted switching output logic. Measuring principle An electrode inside the sensor tip builds a capacitor together with the surroundings. The medium with its dielectric constant (DC value) is defining the capacitance value. A resonance circuit is created in combination with a coil in the sensor head. Switching signal tripping is according to the measured resonance frequency and the programmed trigger thresholds. G 1/2 A G 1/2 G 1/2 A Masszeichnungen 41 A/F 22 41 166 41 97 A/F 27 LBFS-xxGxx.x LBFS-xxAxx.x G 1/2 A ISO 228-1 G 1/2 A ISO 228-1 with cooling neck G 1/2 A DIN 3852-E, NBR gasket G 1/2 A G 1/2 A LBFS-xx1xx.x Design and specifications subject to change without notice 97 41 A/F 27 97 A/F 22 48 97 LBFS-xx4xx.x G 1/2 A DIN 3852-E, FKM (Viton®) gasket G 1/2 A hygienic EN/13052016 LBFS-xxBxx.x www.baumer.com Data sheet CleverLevel® LBFS Page 4 / 10 Level measurement CleverLevel® LBFS Point level detection Dimensional drawings 82 117 Ø18 Ø14,6 Ø14,6 Sealing ring Compression ring Screw-in plug 272 357 166 34 228 276 LBFS-xxKxx.x LBFS-xxLxx.x G 1/2 A hygienic, length 82 mm G 1/2 A hygienic, sliding connection, length 250 mm 39 68 97 A/F 27 A/F 36 38 97 97 LBFS-xx3xx.x G 1/2 A ISO 228-1 for reverse assembly (in-shell thread) G 3/4 A ISO 228-1 G1A ISO 228-1 1/2-14 NPT A/F 22 35 35 166 100 3/4-14 NPT LBFS-xx2xx.x 1/2 NPT LBFS-xx5xx.x 39 A/F 27 97 LBFS-xxMxx.x LBFS-xx6xx.x 1/2-14 NPT 1/2-14 NPT with cooling neck 3/4-14 NPT EN/13052016 LBFS-xxNxx.x Design and specifications subject to change without notice A/F 24 G1A Ø27 G 3/4 A G 1/2 A www.baumer.com Data sheet CleverLevel® LBFS Page 5 / 10 Level measurement CleverLevel® LBFS Point level detection 20 32 M12 Polycarbonate or stainless steel M18×1 65 97 PVC MacroMelt Dimensional drawings 24 LBFS-xx7xx.x LBFS-x1xxx.x LBFS-x3xxx.x M18x1 LBFS-x2xxx.x Cable outlet Connector M12 Electrical connection Terminal assignment 4 3 1 2 Connector M12 1 2 3 4 Cable outlet Brown White Blue Black Function + Vs Normally closed (NC) 0V Normally open (NO) Switching characteristic Switching polarity Normally closed (NC) PNP PNP 11 11 22 22 NPN ++ ++ –– –– LL LL 44 44 11 11 33 33 22 22 ++ ++ –– –– 44 44 11 11 NPN LL LL 44 44 11 11 ++ ++ –– –– 33 33 22 22 LL LL 33 33 22 22 LL LL EN/13052016 LED 33 33 ++ ++ –– –– LED Normally open (NO) 44 44 Design and specifications subject to change without notice Switching logic www.baumer.com Data sheet CleverLevel® LBFS Page 6 / 10 Level measurement CleverLevel® LBFS Point level detection Ordering code LBFS Type Level switch - x x x x x . x LBFS Compliance and approvals Standard ATEX II 1 G Ex ia IIC T4/T5 (4) ATEX II 1 D Ex ta IIIC T100 °C Da (2) ATEX II 3 G Ex nA II T4/T5 ATEX II 1 G Ex ia IIC T4/T5 and ATEX II 1 D Ex ta IIIC T100 °C Da (4) (2) cULus Listed, Class 2, E365692 Electrical connection Connector M12, 4 pin, polycarbonate (with LED) Cable outlet 5 m, 4-wire, PVC (3) Connector M12, 4 pin, stainless steel (without LED) 0 1 2 3 4 A 1 2 3 Process connection G 1/2 A ISO 228-1 G 1/2 A ISO 228-1 with cooling neck (2) G 1/2 A DIN 3852 form E, NBR gasket G 1/2 A DIN 3852 form E, FKM (Viton®) gasket G 1/2 A hygienic G 1/2 A hygienic, length 82 mm (2) G 1/2 A hygienic, sliding connection, length 250 mm (2) G 1/2 A ISO 228-1 for reverse assembly (in-shell thread) (5) G 3/4 A ISO 228-1 G 1 A ISO 228-1 1/2-14 NPT 1/2-14 NPT with cooling neck (2) 3/4-14 NPT M18x1 (BCID) (G07) (G07) (G51) (G51) (A03) (A03) (A03) (T10) (G10) (G11) (N02) (N02) (N03) (M11) Wetted parts material AISI 304 (1.4301) (available for „Process connection“ 1, 2, 3, 5, 6, 7) AISI 316L (1.4404) Switching polarity PNP NPN 1 G A B 4 K L 5 2 3 N M 6 7 1 2 1 2 Configuration Factory setting Customer-specific 0 C EN/13052016 Design and specifications subject to change without notice (2) Not available for „Process connection“ 2 (cable outlet) (3) Ambient temperature 70 °C max. (4) The isolating barrier PROFSI3-B25100-ALG-LS is recommended with PNP switching polarity for Ex ia IIC (please refer to accessories, page 10) (5) Including gasket ZPX3-14B0 (glass/aramide fiber with NBR) www.baumer.com Data sheet CleverLevel® LBFS Page 7 / 10 Level measurement CleverLevel® LBFS Point level detection Accessories Industrial weld-in sleeves for LBFS-xx1xx.x, (BCID: G07) Description Ordering code Thick wall tank - AISI 304 (1.4301) ZPW1-711 Thick wall tank - AISI 316L (1.4404) ZPW1-721 Hygienic adapters for LBFS-xx4xx.x, LBFS-xxKxx.x, LBFS-xxLxx.x (BCID: A03) TYPE EL - Class I DECEMBER 2012 Description Ordering code Clamp, DIN 32676 DN 25, DN 40 ISO 2852 DN 25, DN 38 ZPH1-3213 DIN 32676 DN 50 ISO 2852 DN 51 ZPH1-3216 DIN 11851 DN 25 DN 40 DN 50 ZPH1-3221 ZPH1-3224 ZPH1-3225 SMS 1145 DN 51 ZPH1-3236 Varivent® Type N ZPH1-324E TYPE EL - Class I EN/13052016 Design and specifications subject to change without notice DECEMBER 2012 www.baumer.com Data sheet CleverLevel® LBFS Page 8 / 10 Level measurement CleverLevel® LBFS Point level detection Accessories Hygienic weld-in sleeves for LBFS-xx4xx.x, LBFS-xxKxx.x, LBFS-xxLxx.x (BCID: A03) Description Ordering code Tanks, with leak detection port ZPW2-321 Thin wall tanks ZPW2-322 Tanks, pipes ZPW2-324 Pipe with collar DN 25 ... DN 50 DN 65 ... DN 150 ZPW2-326 ZPW2-327 TYPE EL - Class I DECEMBER 2012 Threaded adapters for LBFS-xx4xx.x, LBFS-xxKxx.x, LBFS-xxLxx.x (BCID: A03) Ordering code Vibronic level switch replacement EH FTL G 3/4 A VS G 3/4 A EH FTL G 1 A VS G 1 A ZPH1-32BA ZPH1-32BC ZPH1-32CB ZPH1-32CD Industrial G1A G 1 1/2 A G2A ZPI1-32B ZPI1-32D ZPI1-32E EN/13052016 Design and specifications subject to change without notice Description www.baumer.com Data sheet CleverLevel® LBFS Page 9 / 10 Level measurement CleverLevel® LBFS Point level detection Accessories Spare parts Description Ordering code G 1/2 A gland nut for LBFS-xxL2x.x with sliding connection (BCID: A03) ZPX1-008 Compression ring kit for LBFS-xxL2x.x with sliding connection (BCID: A03) ZPX1-006 Gasket for LBFS-xx5xx.x for reverse assembly (BCID: T10) ZPX3-14B0 Description Ordering code FlexProgrammer 9701 Programming kit for sensor parameterization. The set contains a FlexProgrammer, all cables needed, carrying strap and the FlexProgrammer software on a CD. 9701-0001 ATEX isolating barrier for LBFS-xxxx1.x, LBFS-xxxx4.x with PNP switching polarity for Ex ia IIC PROFSI3-B25100-ALG-LS Interfaces EN/13052016 Design and specifications subject to change without notice For more detailed information please refer to the applicable product data sheet. www.baumer.com Data sheet CleverLevel® LBFS Page 10 / 10