Inductive sensors IFRM 08X Inductive sensors NAMUR sample drawing 41 SW 13 25 M8 x 1 M8 x 1 general data sample picture approvals/certificates ATEX 1G electrical data switching frequency < 5 kHz normal operating voltage 8,2 VDC voltage supply range +Vs 5 ... 30 VDC current consumption undamped > 4 mA current consumption damped < 1 mA current consumption max. (no load) 10 mA output circuit NAMUR residual ripple < 10 % Vs mechanical data type cylindrical threaded dimension 8 mm ambient conditions operating temperature -25 ... +75 °C protection class IP 67 safe maximum values EC-type-examination Certificate PTB 03 ATEX 2146 marking II 1G Ex ia IIC T6 Ga current Ii < 37 mA voltage Ui < 13,5 VDC power Pi < 0,125 W internal capacitance Ci < 50 nF internal inductance Li < 0,2 mH operating temperature Ta (temp. class T5) -20 ... +60 °C operating temperature Ta (temp. class T6) -20 ... +40 °C order reference nominal sensing distance Sn mounting type housing material housing length connection types IFRM 08X9103 2 mm non-flush brass nickel plated 27 mm cable, 2 m IFRM 08X9501/S35 1,5 mm flush stainless steel 50 mm connector M8 IFRM 08X9503 1,5 mm flush brass nickel plated 25 mm cable, 2 m IFRM 08X9503/S35 1,5 mm flush stainless steel 41 mm connector M8 1 www.baumer.com 2/6/2015