data sheet - family

Inductive sensors
IFRM 08X
Inductive sensors NAMUR
sample drawing
41
SW 13
25
M8 x 1
M8 x 1
general data
sample picture
approvals/certificates
ATEX 1G
electrical data
switching frequency
< 5 kHz
normal operating voltage
8,2 VDC
voltage supply range +Vs
5 ... 30 VDC
current consumption undamped
> 4 mA
current consumption damped
< 1 mA
current consumption max. (no load)
10 mA
output circuit
NAMUR
residual ripple
< 10 % Vs
mechanical data
type
cylindrical threaded
dimension
8 mm
ambient conditions
operating temperature
-25 ... +75 °C
protection class
IP 67
safe maximum values
EC-type-examination Certificate
PTB 03 ATEX 2146
marking
II 1G Ex ia IIC T6 Ga
current Ii
< 37 mA
voltage Ui
< 13,5 VDC
power Pi
< 0,125 W
internal capacitance Ci
< 50 nF
internal inductance Li
< 0,2 mH
operating temperature Ta (temp. class T5)
-20 ... +60 °C
operating temperature Ta (temp. class T6)
-20 ... +40 °C
order reference
nominal sensing distance Sn
mounting type
housing material
housing length
connection types
IFRM 08X9103
2 mm
non-flush
brass nickel plated
27 mm
cable, 2 m
IFRM 08X9501/S35
1,5 mm
flush
stainless steel
50 mm
connector M8
IFRM 08X9503
1,5 mm
flush
brass nickel plated
25 mm
cable, 2 m
IFRM 08X9503/S35
1,5 mm
flush
stainless steel
41 mm
connector M8
1
www.baumer.com
2/6/2015