cd00248402

AN3060
Application note
Applications guide for serial real-time clocks (RTCs)
By Doug Sams
Introduction
ST’s family of serial real-time clocks (RTCs) has been very popular with users. Over the years, many
topics associated with these devices have been addressed by the applications groups supporting them.
This document is a compilation of some of the most common issues addressed ranging from layout
considerations for crystals to proper software access upon power-up. Readers will find this helpful in
understanding some of the subtleties of RTCs and what it takes to keep them running reliably.
August 2015
DocID16253 Rev 3
1/25
www.st.com
Contents
AN3060
Contents
1
2
Battery hookup and charging protection....................................... 5
1.1
Series resistors ................................................................................. 5
1.2
Decoupling capacitors on the battery ................................................ 5
1.3
Blocking diode ................................................................................... 6
1.4
Underwriters Laboratories documents for ST real-time clocks .......... 6
1.5
Battery mounting ............................................................................... 7
Layout considerations .................................................................... 8
2.1
3
What are some basic layout considerations for the RTC crystal? ..... 8
Oscillator circuit .............................................................................. 9
3.1
Besides the crystal, what other components do I need to add to
make my RTC oscillator work correctly? ........................................................ 9
4
Undershoot .................................................................................... 11
4.1
Can undershoot affect operation of my real-time clock? How? What
can be done to guard against it? .................................................................. 11
5
Switchover voltage ........................................................................ 12
5.1
Does the switchover voltage depend on the battery level? Or is it
always a fixed value? What is the maximum battery voltage for an RTC? ... 12
6
Oscillator fail detect ...................................................................... 15
6.1
7
Battery low detect.......................................................................... 16
7.1
8
How does the battery low bit work? Can it detect a missing battery?16
Halt (HT) bit .................................................................................... 18
8.1
9
What is the OF bit? How does it work? ........................................... 15
What does the halt bit (HT) do? How do I use it? ............................ 18
RTC initialization ........................................................................... 21
9.1
What is the best sequence for accessing the RTC at first power-up?
On subsequent power-ups? ......................................................................... 21
10
2/25
Revision history ............................................................................ 24
DocID16253 Rev 3
AN3060
List of tables
List of tables
Table 1: Summary of deselect and switchover thresholds ....................................................................... 13
Table 2: M41T81S register map ............................................................................................................... 16
Table 3: M41ST85W register map ............................................................................................................ 18
Table 4: Document revision history .......................................................................................................... 24
DocID16253 Rev 3
3/25
List of figures
AN3060
List of figures
Figure 1: Battery switchover circuit inside RTC/NVRAM ............................................................................ 5
Figure 2: Effects of a diode in the VBAT path ............................................................................................... 6
Figure 3: SNAPHAT SOIC package ........................................................................................................... 6
Figure 4: Coin cell battery with tabs ............................................................................................................ 7
Figure 5: Layout considerations .................................................................................................................. 8
Figure 6: Built-in load capacitors ................................................................................................................ 9
Figure 7: Typical parasitic diode ............................................................................................................... 11
Figure 8: Undershoot protection ............................................................................................................... 11
Figure 9: Typical switchover circuits ......................................................................................................... 12
Figure 10: Switchover circuit ..................................................................................................................... 13
Figure 11: Oscillator fail detect circuit ....................................................................................................... 15
Figure 12: Battery monitor function ........................................................................................................... 17
Figure 13: Clock and non-clock registers ................................................................................................. 19
Figure 14: M41T83/M41T82 power-up defaults ....................................................................................... 21
Figure 15: First power-up .......................................................................................................................... 22
Figure 16: Power-up from backup ............................................................................................................ 23
4/25
DocID16253 Rev 3
AN3060
1
Battery hookup and charging protection
Battery hookup and charging protection
The battery hookup for ST's serial real-time clocks is very simple. Charging protection
circuits are built into the RTCs, so external resistors and diodes are not required.
Furthermore, adding components to the battery path can have detrimental effects. For
example, series resistors in the battery path can cause switchover issues which may
adversely affect the battery monitor circuit in some devices.
1.1
Series resistors
All ST serial RTC's which include a switchover circuit also include current limiting resistors
in the battery path. In the drawing below, RB is required by Underwriters Laboratories. It
limits any current flowing into the battery to less than 1 mA. Because this is built into the
device, no external resistor is necessary.
Figure 1: Battery switchover circuit inside RTC/NVRAM
1.2
Decoupling capacitors on the battery
It is common for users to add a decoupling capacitor to any supply pin. However, in
applications such as this, the leakage current in the capacitor may be as high as or higher
than the backup current. That is, users could see the battery life appreciably shortened due
to leakage through the capacitor. Furthermore, batteries have very good capacitor
characteristics, so external capacitors are not needed.
DocID16253 Rev 3
5/25
Battery hookup and charging protection
1.3
AN3060
Blocking diode
Diode D1 in the drawing blocks current from flowing from VCC back into the battery when
the system is powered by VCC. So no external diode is required for this purpose.
In some applications, the backup supply may be higher than the RTC's rated maximum
battery voltage. In that case, some users may try to drop the voltage using a diode. That
will drop the voltage somewhat, but users should keep in mind that, at the very low backup
current draw of real-time clocks, on the order of 300-500 nA, the drop across the diode may
only be 200-300 mV, well below the popular 0.7 V commonly associated with diodes.
Another concern when using a diode in the VBAT path is its effect on backup life. As shown
in the graph below, when VBB falls below the VBAT-MIN level, the part will fail. With a diode in
the path, when the battery voltage decays, the minimum threshold will be crossed earlier in
time resulting in a loss of battery life.
Figure 2: Effects of a diode in the VBAT path
1.4
Underwriters Laboratories documents for ST real-time
clocks
For devices in ST's SNAPHAT SOIC package, sec5_sna_rev1.pdf is the correct UL
document.
For all other RTC packages, please refer to sec3_nba_rev1.pdf.
Figure 3: SNAPHAT SOIC package
6/25
DocID16253 Rev 3
AN3060
1.5
Battery hookup and charging protection
Battery mounting
Coin cell batteries are often mounted in battery holders. Users can easily remove and
replace those batteries. In some instances, when used in harsh environments, batteries in
holders may momentarily lose contact due to shock or vibration. The typical result is
corruption of the device contents. For those applications, batteries with mounting tabs will
provide more reliable connections.
Figure 4: Coin cell battery with tabs
DocID16253 Rev 3
7/25
Layout considerations
AN3060
2
Layout considerations
2.1
What are some basic layout considerations for the RTC
crystal?
Layout considerations are straightforward for the 32 KHz crystals used with ST's M41
series real-time clocks.
Figure 5: Layout considerations
The primary consideration is lead length. The crystal should be mounted as near as
possible to the RTC to keep the traces short. A guard ring around these connections,
connected to ground, is very important to avoid picking up unwanted noise, which might
affect timekeeping.
Users should avoid running signals directly underneath this area unless a ground plane
resides between the signals and the crystal connections.
When possible, users can add an island ground plane under the area of the ring and crystal
body. This plane is on a separate layer from the ring, and isolated from the PCB ground
plane. It connects to ground at the GND pin of the RTC.
No other components are shown in the layout because the crystal is all that is required for
the RTC oscillator to work. No external load capacitors or bias resistors should be added.
8/25
DocID16253 Rev 3
AN3060
Oscillator circuit
3
Oscillator circuit
3.1
Besides the crystal, what other components do I need to
add to make my RTC oscillator work correctly?
None. Nothing else is required. ST's real-time clocks have built-in load capacitors. External
load capacitors are not needed, nor are external resistors. All that is needed is the crystal.
It must be a 32,768 Hz watch crystal and be rated for the load capacitance built into the
RTC.
Figure 6: Built-in load capacitors
No other components are required to make the oscillator run. Adding any external
components will only serve to reduce the accuracy and reliability of the oscillator. Extra
load capacitors will tend to slow the clock. At low temperatures, such capacitance, or any
external resistance, may keep the oscillator from starting.
Matching load capacitance
Each RTC comes with built-in load capacitors. These are usually specified as 12.5 pF, or in
the case of the M41T6x family, 6 pF. The crystal selected for use with the RTC should have
this same rating. Mismatched crystals will tend to run slightly off frequency. For example, a
crystal rated for 12.5 pF expects to see that load. If it is used with an RTC rated for 6 pF,
the crystal will only see 6 pF instead of the specified 12.5 pF and will thus run fast.
DocID16253 Rev 3
9/25
Oscillator circuit
AN3060
Effective load capacitance value versus internal capacitance value
Occasionally, the reader will see a reference to the individual load capacitors. There are
two used inside the RTC - one on each leg of the crystal. The actual value of each is twice
the rated or effective load value - that is, twice the load value specified in the data sheet.
This is because the internal load capacitors add in series. In Figure 6: "Built-in load
capacitors", the effective load capacitance is:
Thus, when CL1 and CL2 are equal, the effective load capacitance, CL - the value listed in
the data sheet - is half of CL1 and CL2. An ST RTC rated for 12.5 pF will have two 25 pF
capacitors built into its oscillator circuit. The reader is encouraged to be aware of this.
Furthermore, the reader should keep in mind that the crystal specifications should match
the rated value - in this case 12.5 pF - and not the individual values.
10/25
DocID16253 Rev 3
AN3060
Undershoot
4
Undershoot
4.1
Can undershoot affect operation of my real-time clock?
How? What can be done to guard against it?
Inherent in all field effect devices - all CMOS devices - are parasitic diodes resulting from
the intersection of P and N type regions in the device. Every PN junction forms a diode
which will conduct under any condition which biases the P region above the N region.
In Figure 7: "Typical parasitic diode", if VCC drops sufficiently below ground, the parasitic
diode will be turned on thus drawing current through the device. Significant undershoot on
VCC can result in enough current flow to cause some disturbance in the real-time clock
registers and hence can adversely affect timekeeping. Therefore, undershoot should be
avoided.
Figure 7: Typical parasitic diode
VCC
Most ST real-time clocks specify a minimum VCC of –0.3 V thereby limiting negative
undershoot to 0.3 V below ground.
Some supplies ramp very quickly when power cycling with the result that ringing can occur
which produces an undershoot condition that can cause problems for real-time clocks.
In the rare situations where this occurs, the best protection is a back biased Schottky diode
on the VCC pin as shown in Figure 8: "Undershoot protection". This addition has been
shown to be a very reliable fix for undershoot problems.
Figure 8: Undershoot protection
DocID16253 Rev 3
11/25
Switchover voltage
AN3060
5
Switchover voltage
5.1
Does the switchover voltage depend on the battery level? Or
is it always a fixed value? What is the maximum battery
voltage for an RTC?
Figure 9: Typical switchover circuits
VCC
VCC
VCC-INT
VBAT
VCC-INT
VBAT
VSO
VSO
With fixed reference
With battery reference
Power fail deselect voltage, VPFD
When VCC falls to the power-fail deselect level, VPFD, the part deselects thereby cutting off
communications to the host; it is write protected.
For ST's serial real-time clocks, VPFD is either equal to - or a function of - the switchover
voltage, VSO. Thus, the deselect and switchover operations are tightly coupled.
Switchover voltage, VSO
Switchover connects the backup supply - usually a battery, but sometimes a capacitor or
super-cap - to the internal VCC of the device thereby maintaining the timekeeping operation
in the absence of system power. VSO is the value of VCC at which the part switches over to
VBAT.
Fixed reference
Most ST serial real-time clocks use a fixed, precision reference for the switchover
threshold. Regardless of the level of VBAT, the part will always deselect and switchover at
the same VCC levels.
Battery reference
Some older RTCs use the battery as a reference. One diode drop is applied, internal to the
RTC, to the battery pin, and that level determines the switchover threshold. Typically, the
diode drop is 0.5 V, but it can vary from 0.3 to 0.8 V. For brand new lithium coin cell
batteries, the voltage output may be as high as 3.5 V. (Once under load for a while, this will
drop to approximately 3.0 V and remain there for the useful life of the battery.) At low
temperatures, the diode drop will tend toward the minimum value, 0.3 V. This means that,
with new batteries and low temperatures, the switchover threshold may be as high as 3.5 0.3 = 3.2 V. The implication is that parts employing battery references may be problematic
in 3.3 V applications, and will be unsuitable for 3.0 V applications. In those cases, users
should choose parts with fixed references. For example, the M41T81S with fixed reference
12/25
DocID16253 Rev 3
AN3060
Switchover voltage
is well-suited for 3.3 V and 3.0 V applications, and is a drop-in replacement for the older
M41T81 (non-S).
Table 1: Summary of deselect and switchover thresholds
Root part
number
Switchover and deselect parameters
VPFD
VSO
VBAT-MAX
VBAT – 0.5
VBAT – 0.5
VCC
2.8
2.0 < VBACK < VPFD : VBACK
VBACK > VPFD : VPFD
VCC
2.6 V
VBAT < VPFD : VBAT
VBAT > VPFD : VPFD
VCC
M41T11
VBAT – 0.5
VBAT – 0.5
VCC
M41T56
1.25 x VBAT
VBAT
3.5 V
M41T81
VBAT – 0.5
VBAT – 0.5
VCC
M41T81S
2.6 V
VBAT < VPFD : VBAT
VBAT > VPFD : VPFD
VCC
M41T82
VRST(1)
VRST(1)
VCC(max)
M41T83
VRST
(1)
(1)
VCC(max)
M41ST85W
2.6 V
2.5 V
VCC(max)
M41ST87W
2.62 V, THS = 0
2.88 V, THS = 1
2.5 V
VCC(max)
M41T93
VRST(1)
VRST(1)
VCC(max)
M41T94
2.6 V
2.5 V
VCC(max)
M41T00
M41T00AUD
M41T00S
VRST
Notes:
(1)
The reset voltage, VRST, can be specified as 2.32, 2.63 or 2.93 V.
Complex switchover thresholds
Some devices employ more sophisticated switchover circuits which select the lesser of
VPFD and VBAT as the switchover threshold. This ensures that the part remains on VCC for as
long as possible before switching over to the backup supply thus extending the backup life
slightly.
Figure 10: Switchover circuit
VCC
VCC-INT
VBAT
VSO
DocID16253 Rev 3
13/25
Switchover voltage
AN3060
Maximum battery levels
The maximum value for VBAT varies within ST's family of serial RTCs. It is a function of the
process used to fabricate the silicon and considerations made during the design process.
For most parts, the maximum value is VCC(max) (usually 5.5 V).
For parts with VCC as the limit, if VBAT exceeds VCC, parasitic diodes, inherent in CMOS
technology, can be turned on thereby causing problems within the devices. Obviously, it is
okay for VBAT to be above VCC during backup (when VCC is 0). But when operated in active
mode, VBAT should not exceed VCC for these parts.
To be clear, when VCC is the listed limit for VBAT, the limit is the actual working level of VCC
and not VCC-MAX. Conversely, when the limit is VCC(max), the VBAT limit is VCC(max) regardless
of the operating level of VCC.
14/25
DocID16253 Rev 3
AN3060
Oscillator fail detect
6
Oscillator fail detect
6.1
What is the OF bit? How does it work?
OF is the oscillator fail bit, and is set whenever the real-time clock detects approximately 4
to 6 consecutive missing pulses in the 4 KHz tap of the divider chain.
Figure 11: Oscillator fail detect circuit
An RC circuit is used as an integrator. The 4 KHz pulses keep it discharged, and it slowly
charges between pulses. If sufficient pulses are missing, it charges high enough to trip the
comparator and set the OF bit. In the figure above, at low operating voltages, the time
constant will be shorter since the threshold voltage will be lower. Thus, fewer missing
pulses may be required to trigger the OF bit.
The basic mission of the OF function is to indicate when the oscillator has slowed or
stopped as might occur in capacitor backed applications or when the backup battery is
failing. When the backup voltage falls low enough, the part may stop keeping time, but the
registers will not necessarily become reset; the voltage may not drop low enough to
completely reset the part. Subsequently, after power-up, the oscillator will begin running
and, by merely reading the registers, it will not be clear that the timekeeping function had
become halted. The OF bit overcomes this. It provides a way for the system software to
monitor the timekeeping function and know when to advise the end user that the time may
need to be adjusted.
At first power-up, or anytime the oscillator has been turned off via the stop bit, the RC
circuit will be charged, and the OF bit will be set. The user should allow the oscillator to run
for four seconds prior to clearing the OF bit. This is done not only to discharge the RC
circuit but to ensure the oscillator has stabilized.
DocID16253 Rev 3
15/25
Battery low detect
AN3060
7
Battery low detect
7.1
How does the battery low bit work? Can it detect a missing
battery?
Table 2: M41T81S register map
Addr
D7
D6
00h
D5
D4
D3
0.1 seconds
D2
D1
D0
Function/range
BCD format
0.01 seconds
Seconds
00-99
01h
ST
10 seconds
Seconds
Seconds
00-59
02h
0
10 minutes
Minutes
Minutes
00-59
03h
CEB
CB
Hours (24-hour format)
Century/hours
04h
0
0
05h
0
0
06h
0
0
07h
10 Hours
0
0
0
Day of week
10 date
0
00-23
Day
01-7
Date: day of month
Date
01-31
Month
Month
01-12
Year
Year
00-99
10M
10 years
08h
OUT
FT
S
Calibration
09h
OFIE
BMB4
BMB3
BMB2
0Ah
AFE
SQWE
ABE
Al 10M
0Bh
RPT4
RPT5
AI 10
date
0Ch
RPT3
HT
0Dh
RPT2
0Eh
RPT1
0Fh
WDF
AF
0
BL
0
OF
0
0
Flags
10h
0
0
0
0
0
0
0
0
Reserved
11h
0
0
0
0
0
0
0
0
Reserved
12h
0
0
0
0
0
0
0
0
Reserved
13h
RS3
RS2
RS1
RS0
0
0
0
0
SQW
BMB1
0-1/
BMB0
Calibration
RB1
RB0
Watchdog
Alarm month
Al month
01-12
Alarm date
Al date
01-31
Alarm hour
Al hour
00-23
Alarm 10 minutes
Alarm minutes
Al min
00-59
Alarm 10 seconds
Alarm seconds
Al sec
00-59
AI 10 hour
Many ST serial real-time clocks include a battery monitor function which sets the BL bit
when the battery is low. The basic functionality is to periodically compare the battery to the
internal 2.5 V reference and set the BL bit whenever the battery voltage is less than 2.5 V.
16/25
DocID16253 Rev 3
AN3060
Battery low detect
Figure 12: Battery monitor function
Periodic checking
The battery is checked every time the RTC powers up from backup mode, and every time
the clock rolls over at midnight (when not in backup mode). During the rollover check, the
battery is loaded to ensure a valid reading.
Power-up check
When an RTC has been in backup mode, its battery has already been loaded and thus a
load is not needed for the battery check. Batteries have a slow enough recovery time that
their outputs will not change quickly so it is not necessary to load them during the power-up
check. Nevertheless, a few devices - the M41T82, M41T83, M41ST87W and M41T93 include loading during the power-up check.
Detecting no battery - open circuit
Some applications call for being able to determine that no battery is installed. Ideally, a no
battery condition should read as low battery, but when the battery input, VBAT, is left open floated - the comparator output will be indeterminate. In order to reliably detect a no battery
condition, a load needs to be applied to the battery node prior to checking it. A resistor
applied across the battery terminals (or between B+ and ground in the case of devices with
no B– pin) is sufficient load for this purpose. This is impractical in the field, but can be
useful in the lab during development.
Using rollover to load the battery
Since the RTC applies a load to the battery during the midnight rollover check, it is possible
for applications to invoke the load by changing the time to near midnight, letting the clock
rollover, then setting the time back to its previous setting plus some delta to account for the
time spent waiting for rollover. This can be helpful during factory test to check that a battery
has been installed.
For example, if it's 17:53:27, the user would store that value, set the clock to 23:59:59, wait
two seconds, read the BL bit, then set the time back to 17:53:29 (17:53:27 + 2 seconds). In
this manner, the battery will be loaded during the check and thus a no battery condition will
be reliably read as battery low.
As stated above, some RTCs do load the clock during power-up, and thus a missing
battery can be detected by simply power-cycling the device.
DocID16253 Rev 3
17/25
Halt (HT) bit
AN3060
8
Halt (HT) bit
8.1
What does the halt bit (HT) do? How do I use it?
Table 3: M41ST85W register map
Addr
Data
D7
D6
00h
D5
D4
Function/range
D3
0.1 seconds
D2
D1
D0
BCD format
0.01 seconds
Seconds
00-99
01h
ST
10 seconds
Seconds
Seconds
00-59
02h
0
10 minutes
Minutes
Minutes
00-59
03h
CEB
CB
Hours (24 hour format)
Century/hours
04h
TR
0
05h
0
0
06h
0
0
07h
10 hours
0
0
0
Day of week
10 date
0
Day
01-7
Date: day of month
Date
01-31
Month
Month
01-12
Year
Year
00-99
10M
10 years
08h
OUT
FT
S
Calibration
09h
WDS
BMB4
BMB3
BMB2
0Ah
AFE
SQWE
ABE
Al 10M
0Bh
RPT4
RPT5
0Ch
RPT3
HT
0Dh
RPT2
0Eh
RPT1
0Fh
WDF
AF
0
BL
0
0
0
0
Flags
10h
0
0
0
0
0
0
0
0
Reserved
11h
0
0
0
0
0
0
0
0
Reserved
12h
0
0
0
0
0
0
0
0
Reserved
13h
RS3
RS2
RS1
RS0
0
0
0
0
SQW
BMB1
0-1/
00-23
BMB0
Control
RB1
RB0
Watchdog
Alarm month
Al month
01-12
AI 10 date
Alarm date
Al date
01-31
AI 10 hour
Alarm hour
Al hour
00-23
Alarm 10 minutes
Alarm minutes
Al min
00-59
Alarm 10 seconds
Alarm seconds
Al sec
00-59
Many of ST's serial real-time clocks include a halt bit (HT) in the registers. This bit is used
to halt updates to the user clock registers. When HT is set, the internal counters continue
timekeeping, but the buffer/transfer registers accessed by the user are frozen.
18/25
DocID16253 Rev 3
AN3060
Halt (HT) bit
Figure 13: Clock and non-clock registers
Coherency
The clock counters are buffered to ensure coherency. At the start of a read of the clock
registers, the device will copy the counters to the buffer/transfer registers, then make no
further updates to these registers for the duration of the read cycle. (The HT bit is not set at
this time, but the updates are halted.) By copying all the counters simultaneously, the
values in the registers will all be from the same instant in time and thus will be coherent.
Example of incoherency
Without having the intervening buffer/transfer registers, if the user began directly reading
the counters at 23:59:59, a read of the seconds register would return 59 seconds. After the
address pointer incremented, the next read would return 59 minutes. The next read should
return 23 hours, but if the clock happened to increment between the reads, the user would
see 00 hours. When the time was re-assembled, it would appear as 00:59:59, and thus be
off by one hour. It would be incoherent.
By using the buffer/transfer registers to hold a copy of the time, the user is able to read the
entire set of registers without any values changing during the read.
Similarly, when the application needs to change the time in the counters, it is necessary
that all the counters be loaded simultaneously. Thus, the user writes sequentially to the
various buffer/transfer registers, then they are copied to the counters in a single transfer
thereby coherently loading the counters.
DocID16253 Rev 3
19/25
Halt (HT) bit
AN3060
Write flag
The copying to the counters is caused by an internal write flag which gets set anytime a
write occurs in one of the buffer transfer registers, but not to any of the other (non-clock)
registers. For example, writing the watchdog or calibration register will not set the write flag,
but writing the seconds or day-of-week will set the flag.
2
At the end of the write cycle, when a STOP condition occurs on the I C bus, if the device
sees the write flag set, it copies all the buffer transfer registers to the clock counters. Even
if only one or two of the buffer/transfer registers is overwritten by the application, all the
registers will be copied to the counters.
Auto-setting of the HT bit
Whenever the device is powered down, the time and date are copied to the buffer/transfer
registers and the HT bit is set automatically. At power-up, the user can read the device
(with the HT bit still set) and retrieve the time of power-down from the registers. This allows
the application to determine how long the power outage lasted which is needed in some
situations. As long as the HT bit remains set, reads will return the time of power-down
(assuming no writes have occurred to alter the contents of the buffer/transfer registers).
In order to read the present time, the user must first clear (write a 0 to) the HT bit.
Subsequent reads will return the current time. Subtracting the time of power-down from the
present time establishes the length of the power outage.
Writing with the HT bit set
Following a power failure, the buffer/transfer registers contain the time of power-down.
Should the user write to any of the clock registers (addresses 0x00 to 0x07 in the table
above), the write flag will be set. Thus, at the end of the write cycle, the counters will be
updated from the registers.
If the HT bit is still set, the buffer/transfer registers contain the time of power-down modified
by the written value. Thus, at the end of the write sequence, the modified time of powerdown will be written back into the counters thus causing an apparent loss of time.
Example: Let the time/date of power down be, Mon, 9-Mar-08, 7:23:44pm. At power-up,
prior to clearing the HT bit, the user writes the ST bit in the seconds register thus setting
the write flag, but writes no other bits. At the end of the write cycle, the present time will
revert to the time of power-down thus resulting in an apparent loss of time.
Conversely, if the HT bit had been cleared prior to the write, the buffer/transfer registers
would have been updated to the present time. As before, a write of the ST bit would have
set the write flag, but the resultant update of the counters would have placed the current
time back in them. They would have been written over with the same values already
present in the counters. No loss of time would occur.
For more information, refer to application note AN1572.
20/25
DocID16253 Rev 3
AN3060
RTC initialization
9
RTC initialization
9.1
What is the best sequence for accessing the RTC at first
power-up? On subsequent power-ups?
This will vary from device to device, and hence a comprehensive answer is beyond the
scope of this document. Instead, we offer an example for the M41T83/M41T82.
Initializing and accessing the M41T83/M41T82
At first power-up, the part is in a benign state - the alarms and interrupts are disabled as
are the watchdog and timer. The OUT bit is high, and the frequency test bit, FT, is disabled.
Both the digital and analog calibration functions are set to the neutral points and the OTP
bit is set to 0 thus selecting the user analog calibration register over the factory value. (OTP
applies only to the M41T83 in the embedded crystal [MY] package.)
The squarewave output is enabled and 32.768 kHz is selected. (This allows devices using
this as a reference to have it at first power-up without need of user intervention.)
Figure 14: M41T83/M41T82 power-up defaults
The clock registers - hours, minutes, seconds, year, month, date - are unknown. Only the
century bits, CB1:CB0, are defined (00).
The stop bit, ST, powers up cleared thus enabling the 32 KHz oscillator. But, since the
oscillator has not been running (prior to this first power-up) the oscillator fail detect bit, OF,
will be set.
Lastly, as is the case at all power-ups, the HT bit is set.
DocID16253 Rev 3
21/25
RTC initialization
AN3060
First power-up
Since most of the peripheral and alarm functions are not enabled at power-up, there is little
urgency to initialize the part. The only item which might require immediate attention is the
squarewave function which powers-up running. Some applications may prefer to disable
this, or change its frequency.
The next thing the user should do is to write the HT bit to 0, then set the time and date. (For
other RTCs, at this point in the flow, if the ST bit is 1, it should be cleared to 0.)
If the application will be calibrated, this should be the next step.
Then the OF bit should be cleared (written to 0). Since power-up - since oscillator startup four seconds must have elapsed before this step is done. If calibration was performed, then
the time required to do that can be subtracted from the four seconds, and if calibration took
longer than that, then no additional waiting is required. The software should verify that the
OF bit remained cleared before progressing to the next step.
The next few items are optional. If the watchdog will be used, it can be started now,
assuming the software will soon get to the operational code which updates the watchdog.
Otherwise, the software should wait until the top of its main routine to start the watchdog.
If the timer or alarms will be used, the user might set them here, or again wait until the top
of the main routine. That will prevent any of these functions from timing out (interrupting)
while the processor is still running its initialization routine.
Figure 15: First power-up
22/25
DocID16253 Rev 3
AN3060
RTC initialization
Power-up from backup
Coming out of backup, the first thing to do is read the time. Prior to clearing the HT bit, the
RTC's buffer/transfer registers will contain the time of power down. If the duration of power
outage is needed by the application, the time of power down will be required. Otherwise,
this step can be skipped.
The next step is to clear the HT bit by writing it to 0. It is very important that the HT bit be
cleared prior to writing any of the timekeeping registers (addresses 0x00 to 0x07). Failure
to do so can resulting in corrupting the RTC counters.
If, at this point in the application flow, the present time is required, the time would be read.
With the HT bit clear, the present time will be returned by a read.
Upon servicing any interrupts from the RTC - e.g., alarm or OF - the flags register must be
cleared. Most of the flag bits clear upon reading, but the OF bit must be written to 0. Also,
the user should bear in mind that clearing the alarm flags (AF1, AF2) and oscillator fail flag
(OF) will clear the associated interrupt.
Figure 16: Power-up from backup
Watchdog and timer
Lastly, power cycling always leaves the watchdog and timer disabled. If either is being
used by the application, they will need to be re-initialized.
DocID16253 Rev 3
23/25
Revision history
10
AN3060
Revision history
Table 4: Document revision history
24/25
Date
Revision
Changes
04-Nov-2009
1
Initial release.
17-Jul-2012
2
Textual updates concerning device availability.
17-Aug-2015
3
Added Section 1: "Battery hookup and charging protection"
DocID16253 Rev 3
AN3060
IMPORTANT NOTICE – PLEASE READ CAREFULLY
STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications,
and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant
information on ST products before placing orders. ST products are sold pursuant to ST’s terms and conditions of sale in place at
the time of order acknowledgement.
Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application
assistance or the design of Purchasers’ products.
No license, express or implied, to any intellectual property right is granted by ST herein.
Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such
product.
ST and the ST logo are trademarks of ST. All other product or service names are the property of their respective owners.
Information in this document supersedes and replaces information previously supplied in any prior versions of this document.
© 2015 STMicroelectronics – All rights reserved
DocID16253 Rev 3