M41T81S Serial access real-time clock (RTC) with alarms Datasheet − production data Features ■ ■ Counters for tenths/hundredths of seconds, seconds, minutes, hours, day, date, month, year, and century 32 KHz crystal oscillator with integrated load capacitance (12.5 pf) which provides exceptional oscillator stability and high crystal series resistance operation) ■ Oscillator stop detection (monitors clock operation) ■ Serial interface supports I2C bus (400 kHz protocol) ■ Ultra-low battery supply current of 0.6 µA (typ) ■ 2.0 to 5.5 V clock operating voltage ■ Automatic switchover and deselect circuitry (fixed reference) which provides full operation in 3.0 V applications) ■ VCC = 2.7 to 5.5 V ■ 2.5 V ≤ VPFD ≤ 2.7 V ■ Power-down time-stamp (HT bit) which allows determination of time elapsed in battery backup ■ Battery low flag ■ Programmable alarm and interrupt function (valid even during battery backup mode) ■ Accurate programmable watchdog timer (from 62.5 ms to 128 s) ■ Software clock calibration (to compensate for crystal deviation due to temperature) ■ Operating temperature of –40 to 85 °C ■ Package options include an 8-lead SOIC or 18-lead embedded crystal SOIC May 2012 This is information on a product in full production. 8 1 SO8 8-pin SOIC 18 1 Doc ID 10773 Rev 7 SOX18 18-pin (300 mil) SOIC with embedded crystal 1/32 www.st.com 1 Contents M41T81S Contents 1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2-wire bus characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Bus not busy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Start data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Stop data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Data valid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Acknowledge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 READ mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 WRITE mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Data retention mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3 Clock operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Power-down time-stamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Clock registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Calibrating the clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Setting alarm clock registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Watchdog timer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Square wave output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Century bit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Battery low warning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Oscillator fail detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Oscillator fail interrupt enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Output driver pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Preferred initial power-on default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4 Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 5 DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 6 Package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 2/32 Doc ID 10773 Rev 7 M41T81S Contents 7 Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 8 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Doc ID 10773 Rev 7 3/32 List of tables M41T81S List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. 4/32 Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Clock register map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Alarm repeat modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Square wave output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Preferred default values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Operating and AC measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 DC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Crystal electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Power down/up AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Power down/up trip points DC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 SO8 – 8-lead plastic small outline (150 mils body width), package mechanical data. . . . . 28 SOX18 – 18-lead plastic small outline, 300 mils, embedded crystal, package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Doc ID 10773 Rev 7 M41T81S List of figures List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. Figure 19. Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 8-pin SOIC (M) connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 18-pin, 300 mil SOIC (MY) connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Serial bus data transfer sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Acknowledgement sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Slave address location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 READ mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Alternative READ mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 WRITE mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Crystal accuracy across temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Clock calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Alarm interrupt reset waveform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Backup mode alarm waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 AC measurement I/O waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Power down/up mode AC waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Bus timing requirements sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 SO8 – 8-lead plastic small package outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 SOX18 – 18-lead plastic small outline, 300 mils, embedded crystal, outline . . . . . . . . . . . 29 Doc ID 10773 Rev 7 5/32 Description 1 M41T81S Description The M41T81S is a low-power serial real-time clock (RTC) with a built-in 32.768 kHz oscillator (external crystal controlled). Eight bytes of the SRAM are used for the clock/calendar function and are configured in binary-coded decimal (BCD) format. An additional 12 bytes of SRAM provide status/control of alarm, watchdog and square wave functions. Addresses and data are transferred serially via a two line, bidirectional I2C interface. The built-in address register is incremented automatically after each WRITE or READ data byte. The M41T81S has a built-in power sense circuit which detects power failures and automatically switches to the battery supply when a power failure occurs. The energy needed to sustain the clock operations can be supplied by a small lithium button supply when a power failure occurs. Functions available to the user include a non-volatile, time-ofday clock/calendar, alarm interrupts, watchdog timer and programmable square wave output. The eight clock address locations contain the century, year, month, date, day, hour, minute, second and tenths/hundredths of a second in 24-hour BCD format. Corrections for 28, 29 (leap year - valid until year 2100), 30 and 31 day months are made automatically. The M41T81S is supplied in either an 8-pin SOIC or an 18-pin 300 mil SOIC package which includes an embedded 32 KHz crystal. The 18-pin, embedded crystal SOIC requires only a user-supplied battery to provide nonvolatile operation. Figure 1. Logic diagram VCC VBAT (1) XI XO(1) M41T81S IRQ/FT/OUT/SQW SCL SDA VSS AI09160 1. For SO8 package only 6/32 Doc ID 10773 Rev 7 M41T81S Description Table 1. Signal names (1) XI Oscillator input XO(1) Oscillator output IRQ/OUT/FT/SQW Interrupt / output driver / frequency test / square wave (open drain) SDA Serial data input/output SCL Serial clock input VBAT Battery supply voltage VCC Supply voltage VSS Ground NC(2) No connect NF(2) No function 1. For SO8 package only. 2. NC and NF pins should be tied to VSS. Figure 2. 8-pin SOIC (M) connections XI XO VBAT VSS 1 8 7 2 3 M41T81S 6 4 5 VCC IRQ/FT/OUT/SQW(1) SCL SDA AI09161 1. Open drain output Figure 3. 18-pin, 300 mil SOIC (MY) connections NC NF(1) NF(1) NC NC NC NC VBAT VSS 1 18 17 2 16 3 15 4 5 M41T81S 14 13 6 12 7 11 8 10 9 NC NF(1) NF(1) VCC NC IRQ/FT/OUT/SQW(2) NC SCL SDA AI09162 1. NC and NF pins should be tied to VSS. Pins 2 and 3 are internally shorted together. Pins 17 and 16 are internally shorted together. 2. Open drain output Doc ID 10773 Rev 7 7/32 Description Figure 4. M41T81S Block diagram REAL TIME CLOCK CALENDAR 32KHz OSCILLATOR CRYSTAL OSCILLATOR FAIL CIRCUIT OFIE RTC W/ALARM & CALIBRATION AFE IRQ/FT/OUT/SQW(1) WATCHDOG SDA I2C INTERFACE (2) SQWE SQUARE WAVE SCL WRITE PROTECT FREQUENCY TEST FT OUTPUT DRIVER OUT INTERNAL POWER VCC VBAT VSO COMPARE VPFD AI09163 1. Open drain output 2. Square wave function has the highest priority on IRQ/FT/OUT/SQW output. 8/32 Doc ID 10773 Rev 7 M41T81S 2 Operation Operation The M41T81S clock operates as a slave device on the serial bus. Access is obtained by implementing a start condition followed by the correct slave address (D0h). The 20 bytes contained in the device can then be accessed sequentially in the following order: 1. Tenths/hundredths of a second register 2. Seconds register 3. Minutes register 4. Century/hours register 5. Day register 6. Date register 7. Month register 8. Year register 9. Calibration register 10. Watchdog register 11 - 15. Alarm registers 16. Flags register 17 - 19. Reserved 20. Square wave register The M41T81S clock continually monitors VCC for an out-of-tolerance condition. Should VCC fall below VPFD, the device terminates an access in progress and resets the device address counter. Inputs to the device will not be recognized at this time to prevent erroneous data from being written to the device from a an out-of-tolerance system. Once VCC falls below the switchover voltage (VSO), the device automatically switches over to the battery and powers down into an ultra-low current mode of operation to preserve battery life. If VBAT is less than VPFD, the device power is switched from VCC to VBAT when VCC drops below VBAT. If VBAT is greater than VPFD, the device power is switched from VCC to VBAT when VCC drops below VPFD. Upon power-up, the device switches from battery to VCC at VSO. When VCC rises above VPFD, it will recognize the inputs. For more information on battery storage life refer to application note AN1012, "Predicting the battery life and data retention period of NVRAMs and serial RTCs" . 2-wire bus characteristics The bus is intended for communication between different ICs. It consists of two lines: a bidirectional data signal (SDA) and a clock signal (SCL). Both the SDA and SCL lines must be connected to a positive supply voltage via a pull-up resistor. Doc ID 10773 Rev 7 9/32 Operation M41T81S The following protocol has been defined: ● Data transfer may be initiated only when the bus is not busy. ● During data transfer, the data line must remain stable whenever the clock line is high. ● Changes in the data line, while the clock line is high, will be interpreted as control signals. Accordingly, the following bus conditions have been defined: Bus not busy Both data and clock lines remain high. Start data transfer A change in the state of the data line, from high to low, while the clock is high, defines the START condition. Stop data transfer A change in the state of the data line, from low to high, while the clock is high, defines the STOP condition. Data valid The state of the data line represents valid data when after a start condition, the data line is stable for the duration of the high period of the clock signal. The data on the line may be changed during the low period of the clock signal. There is one clock pulse per bit of data. Each data transfer is initiated with a start condition and terminated with a stop condition. The number of data bytes transferred between the start and stop conditions is not limited. The information is transmitted byte-wide and each receiver acknowledges with a ninth bit. By definition a device that gives out a message is called “transmitter,” the receiving device that gets the message is called “receiver.” The device that controls the message is called “master.” The devices that are controlled by the master are called “slaves.” Acknowledge Each byte of eight bits is followed by one acknowledge bit. This acknowledge bit is a low level put on the bus by the receiver whereas the master generates an extra acknowledge related clock pulse. A slave receiver which is addressed is obliged to generate an acknowledge after the reception of each byte that has been clocked out of the slave transmitter. The device that acknowledges has to pull down the SDA line during the acknowledge clock pulse in such a way that the SDA line is a stable low during the high period of the acknowledge related clock pulse. Of course, setup and hold times must be taken into account. A master receiver must signal an end of data to the slave transmitter by not generating an acknowledge on the last byte that has been clocked out of the slave. In this 10/32 Doc ID 10773 Rev 7 M41T81S Operation case the transmitter must leave the data line high to enable the master to generate the STOP condition. Figure 5. Serial bus data transfer sequence DATA LINE STABLE DATA VALID CLOCK DATA START CONDITION CHANGE OF DATA ALLOWED STOP CONDITION AI00587 Figure 6. Acknowledgement sequence CLOCK PULSE FOR ACKNOWLEDGEMENT START SCL FROM MASTER DATA OUTPUT BY TRANSMITTER 1 2 MSB 8 9 LSB DATA OUTPUT BY RECEIVER AI00601 READ mode In this mode the master reads the M41T81S slave after setting the slave address (see Figure 8 on page 12). Following the WRITE mode control bit (R/W=0) and the acknowledge bit, the word address 'An' is written to the on-chip address pointer. Next the START condition and slave address are repeated followed by the READ mode control bit (R/W=1). At this point the master transmitter becomes the master receiver. The data byte which was addressed will be transmitted and the master receiver will send an acknowledge bit to the slave transmitter. The address pointer is only incremented on reception of an acknowledge clock. The M41T81S slave transmitter will now place the data byte at address An+1 on the bus, the master receiver reads and acknowledges the new byte and the address pointer is incremented to “An+2.” This cycle of reading consecutive addresses will continue until the master receiver sends a STOP condition to the slave transmitter. The system-to-user transfer of clock data will be halted whenever the address being read is a clock address (00h to 07h). The update will resume due to a stop condition or when the pointer increments to any non-clock address (08h-13h). Doc ID 10773 Rev 7 11/32 Operation Note: M41T81S This is true both in READ mode and WRITE mode. An alternate READ mode may also be implemented whereby the master reads the M41T81S slave without first writing to the (volatile) address pointer. The first address that is read is the last one stored in the pointer (see Figure 9 on page 12). Figure 7. Slave address location R/W START A LSB MSB SLAVE ADDRESS 1 1 0 1 0 0 0 AI00602 SLAVE ADDRESS DATA n+1 ACK DATA n ACK BUS ACTIVITY: S ACK ACK WORD ADDRESS (An) R/W S ACK SDA LINE R/W BUS ACTIVITY: MASTER START READ mode sequence START Figure 8. STOP SLAVE ADDRESS P NO ACK DATA n+X SLAVE ADDRESS 12/32 DATA n+X ACK BUS ACTIVITY: DATA n+1 ACK DATA n P NO ACK R/W S ACK SDA LINE ACK BUS ACTIVITY: MASTER STOP Alternative READ mode sequence START Figure 9. AI00899 AI00895 Doc ID 10773 Rev 7 M41T81S Operation WRITE mode In this mode the master transmitter transmits to the M41T81S slave receiver. Bus protocol is shown in Figure 10 on page 13. Following the START condition and slave address, a logic '0' (R/W=0) is placed on the bus and indicates to the addressed device that word address “An” will follow and is to be written to the on-chip address pointer. The data word to be written to the memory is strobed in next and the internal address pointer is incremented to the next address location on the reception of an acknowledge clock. The M41T81S slave receiver will send an acknowledge clock to the master transmitter after it has received the slave address see Figure 7 on page 12 and again after it has received the word address and each data byte. Data retention mode With valid VCC applied, the M41T81S can be accessed as described above with READ or WRITE cycles. Should the supply voltage decay, the power input will be switched from the VCC pin to the battery when VCC falls below the battery backup switchover voltage (VSO). At this time the clock registers will be maintained by the attached battery supply. On power-up, when VCC returns to a nominal value, write protection continues for tREC. For a further, more detailed review of lifetime calculations, please see application note AN1012. STOP SLAVE ADDRESS DATA n+X P ACK DATA n+1 ACK BUS ACTIVITY: DATA n ACK WORD ADDRESS (An) ACK S R/W SDA LINE ACK BUS ACTIVITY: MASTER START Figure 10. WRITE mode sequence AI00591 Doc ID 10773 Rev 7 13/32 Clock operation 3 M41T81S Clock operation The 20-byte register map (see Table 2: Clock register map on page 15) is used to both set the clock and to read the date and time from the clock, in a binary coded decimal format. Tenths/hundredths of seconds, seconds, minutes, and hours are contained within the first four registers. Note: Tenths/hundredths of seconds cannot be written to any value other than “00.” Bits D6 and D7 of clock register 03h (century/hours register) contain the CENTURY ENABLE bit (CEB) and the CENTURY bit (CB). Setting CEB to a '1' will cause CB to toggle, either from '0' to '1' or from '1' to '0' at the turn of the century (depending upon its initial state). If CEB is set to a '0,' CB will not toggle. Bits D0 through D2 of register 04h contain the day (day of week). Registers 05h, 06h, and 07h contain the date (day of month), month and years. The ninth clock register is the calibration register (this is described in the clock calibration section). Bit D7 of register 01h contains the STOP bit (ST). Setting this bit to a '1' will cause the oscillator to stop. If the device is expected to spend a significant amount of time on the shelf, the oscillator may be stopped to reduce current drain. When reset to a '0' the oscillator restarts within one second. The eight clock registers may be read one byte at a time, or in a sequential block. Provision has been made to assure that a clock update does not occur while any of the eight clock addresses are being read. If a clock address is being read, an update of the clock registers will be halted. This will prevent a transition of data during the READ. Power-down time-stamp When a power failure occurs, the HALT (HT) bit will automatically be set to a '1.' This will prevent the clock from updating the registers, and will allow the user to read the exact time of the power-down event. Resetting the HT bit to a '0' will allow the clock to update the registers with the current time. For more information, please refer to AN1572, “Power-down time-stamp function in serial real-time clocks (RTCs)”. Clock registers The M41T81S offers 20 internal registers which contain clock, alarm, watchdog, flags, square wave and calibration data. These registers are memory locations which contain external (user accessible) and internal copies of the data (usually referred to as BiPORT™ cells). The external copies are independent of internal functions except that they are updated periodically by the simultaneous transfer of the incremented internal copy. The internal divider (or clock) chain will be reset upon the completion of a WRITE to any clock address. The system-to-user transfer of clock data will be halted whenever the address being read is a clock address (00h to 07h). The update will resume either due to a stop condition or when the pointer increments to any non-clock address (08h-13h). Clock and alarm registers store data in BCD. Calibration, watchdog and square wave registers store data in binary format. 14/32 Doc ID 10773 Rev 7 M41T81S Clock operation Table 2. Clock register map Addr D7 D6 D5 0.1 seconds 00h D4 D3 D2 D1 0.01 Seconds D0 Function/range BCD format Seconds 00-99 01h ST 10 seconds Seconds Seconds 00-59 02h 0 10 minutes Minutes Minutes 00-59 03h CEB CB Hours (24-hour format) Century/hours 0-1/00-23 04h 0 0 Day 01-7 Date: day of month Date 01-31 Month Month 01-12 Year 00-99 05h 0 0 06h 0 0 08h OUT FT 07h 10 hours 0 0 0 10 date 0 10M Day of week 10 years Year S Calibration 09h OFIE BMB4 BMB3 BMB2 BMB1 BMB0 0Ah AFE SQW ABE Al Calibration RB1 RB0 Alarm month Watchdog Al month 01-12 0Bh RPT4 RPT5 AI 10 date Alarm date Al date 01-31 0Ch RPT3 HT AI 10 hour Alarm hour Al hour 00-23 0Dh RPT2 Alarm minutes Al min 00-59 0Eh RPT1 Al sec 00-59 0Fh WDF AF 0 BL 0 OF 0 0 Flags 10h 0 0 0 0 0 0 0 0 Reserved 11h 0 0 0 0 0 0 0 0 Reserved Alarm 10 minutes Alarm 10 seconds Alarm seconds 12h 0 0 0 0 0 0 0 0 Reserved 13h RS3 RS2 RS1 RS0 0 0 0 0 SQW 0 = Must be set to '0' ABE = Alarm in battery backup mode enable bit AF = Alarm flag (read only) AFE = Alarm flag enable flag BL = Battery low bit BMB0-BMB4 = Watchdog multiplier bits CB = Century bit CEB = Century enable bit FT = Frequency test bit HT = Halt update bit OF = Oscillator fail flag OFIE = Oscillator fail interrupt enable OUT = Output level RB0-RB1 = Watchdog resolution bits RPT1-RPT5 = Alarm repeat mode bits RS0-RS3 = SQW frequency S = Sign bit SQWE = Square wave enable ST = Stop bit WDF = Watchdog flag (read only) Doc ID 10773 Rev 7 15/32 Clock operation M41T81S Calibrating the clock The M41T81S is driven by a quartz controlled oscillator with a nominal frequency of 32,768 Hz. The devices are tested not exceed ±35 ppm (parts per million) oscillator frequency error at 25oC, which equates to about +1.9 to –1.1 minutes per month (see Figure 11 on page 17). When the calibration circuit is properly employed, accuracy improves to better than ±2 ppm at 25°C. The oscillation rate of crystals changes with temperature. The M41T81S design employs periodic counter correction. The calibration circuit adds or subtracts counts from the oscillator divider circuit at the divide by 256 stage, as shown in Figure 12 on page 17. The number of times pulses which are blanked (subtracted, negative calibration) or split (added, positive calibration) depends upon the value loaded into the five calibration bits found in the calibration register. Adding counts speeds the clock up, subtracting counts slows the clock down. The calibration bits occupy the five lower order bits (D4-D0) in the calibration register 08h. These bits can be set to represent any value between 0 and 31 in binary form. Bit D5 is a sign bit; '1' indicates positive calibration, '0' indicates negative calibration. Calibration occurs within a 64 minute cycle. The first 62 minutes in the cycle may, once per minute, have one second either shortened by 128 or lengthened by 256 oscillator cycles. If a binary '1' is loaded into the register, only the first 2 minutes in the 64 minute cycle will be modified; if a binary 6 is loaded, the first 12 will be affected, and so on. Therefore, each calibration step has the effect of adding 512 or subtracting 256 oscillator cycles for every 125,829,120 actual oscillator cycles, that is +4.068 or –2.034 ppm of adjustment per calibration step in the calibration register (see Figure 12 on page 17). Assuming that the oscillator is running at exactly 32,768Hz, each of the 31 increments in the Calibration byte would represent +10.7 or –5.35 seconds per month which corresponds to a total range of +5.5 or –2.75 minutes per month. Two methods are available for ascertaining how much calibration a given M41T81S may require. The first involves setting the clock, letting it run for a month and comparing it to a known accurate reference and recording deviation over a fixed period of time. Calibration values, including the number of seconds lost or gained in a given period, can be found in application note AN934, “TIMEKEEPER® calibration.” This allows the designer to give the end user the ability to calibrate the clock as the environment requires, even if the final product is packaged in a non-user serviceable enclosure. The designer could provide a simple utility that accesses the calibration byte. The second approach is better suited to a manufacturing environment, and involves the use of the IRQ/FT/OUT/SQW pin. The pin will toggle at 512 Hz, when the stop bit (ST, D7 of 01h) is '0,' the frequency test bit (FT, D6 of 08h) is '1,' the alarm flag enable bit (AFE, D7 of 0Ah) is '0,' and the square wave enable bit (SQWE, D6 of 0Ah) is '0' and the watchdog register (09h = 0) is reset. Any deviation from 512 Hz indicates the degree and direction of oscillator frequency shift at the test temperature. For example, a reading of 512.010124 Hz would indicate a +20 ppm oscillator frequency error, requiring a –10 (XX001010) to be loaded into the calibration byte for correction. Note that setting or changing the calibration byte does not affect the frequency test output frequency. 16/32 Doc ID 10773 Rev 7 M41T81S Clock operation The IRQ/FT/OUT/SQW pin is an open drain output which requires a pull-up resistor to VCC for proper operation. A 500-10 k resistor is recommended in order to control the rise time. The FT bit is cleared on power-down. Figure 11. Crystal accuracy across temperature Frequency (ppm) 20 0 –20 –40 –60 ΔF = K x (T – T )2 O F –80 2 K = –0.036 ppm/°C ± 0.006 ppm/°C –100 2 TO = 25°C ± 5°C –120 –140 –160 –40 –30 –20 –10 0 10 20 30 Temperature °C 40 50 60 70 80 AI07888 Figure 12. Clock calibration NORMAL POSITIVE CALIBRATION NEGATIVE CALIBRATION AI00594B Setting alarm clock registers Address locations 0Ah-0Eh contain the alarm settings. The alarm can be configured to go off at a prescribed time on a specific month, date, hour, minute, or second or repeat every year, month, day, hour, minute, or second. It can also be programmed to go off while the M41T81S is in the battery backup mode to serve as a system wake-up call. Bits RPT5-RPT1 put the alarm in the repeat mode of operation. Table 3 on page 19 shows the possible configurations. Codes not listed in the table default to the once per second mode to quickly alert the user of an incorrect alarm setting. Doc ID 10773 Rev 7 17/32 Clock operation M41T81S When the clock information matches the alarm clock settings based on the match criteria defined by RPT5-RPT1, the AF (alarm flag) is set. If AFE (alarm flag enable) is also set (and SQWE is '0.'), the alarm condition activates the IRQ/FT/OUT/SQW pin. Note: If the address pointer is allowed to increment to the flags register address, an alarm condition will not cause the Interrupt/Flag to occur until the address pointer is moved to a different address. It should also be noted that if the last address written is the “Alarm Seconds,” the address pointer will increment to the flag address, causing this situation to occur. The IRQ/FT/OUT/SQW output is cleared by a READ to the flags register as shown in Figure 13. A subsequent READ of the flags register is necessary to see that the value of the alarm flag has been reset to '0.' The IRQ/FT/OUT/SQW pin can also be activated in the battery backup mode. The IRQ/FT/OUT/SQW will go low if an alarm occurs and both ABE (alarm in battery backup mode enable) and AFE are set. Figure 14 illustrates the backup mode alarm timing. Figure 13. Alarm interrupt reset waveform 0Eh 0Fh 10h ACTIVE FLAG HIGH-Z IRQ/FT/OUT/SQW AI04617 Figure 14. Backup mode alarm waveform VCC VPFD VSO trec ABE and AFE Bits AF Bit in Flags Register IRQ/FT/OUT/SQW HIGH-Z AI09164b 18/32 Doc ID 10773 Rev 7 M41T81S Clock operation Table 3. Alarm repeat modes RPT5 RPT4 RPT3 RPT2 RPT1 Alarm setting 1 1 1 1 1 Once per second 1 1 1 1 0 Once per minute 1 1 1 0 0 Once per hour 1 1 0 0 0 Once per day 1 0 0 0 0 Once per month 0 0 0 0 0 Once per year Watchdog timer The watchdog timer can be used to detect an out-of-control microprocessor. The user programs the watchdog timer by setting the desired amount of time-out into the watchdog register, address 09h. Bits BMB4-BMB0 store a binary multiplier and the two lower order bits RB1-RB0 select the resolution, where 00 = 1/16 second, 01 = 1/4 second, 10 = 1 second, and 11 = 4 seconds. The amount of time-out is then determined to be the multiplication of the five-bit multiplier value with the resolution. (For example: writing 00001110 in the watchdog register = 3*1, or 3 seconds). If the processor does not reset the timer within the specified period, the M41T81S sets the WDF (watchdog flag) and generates a watchdog interrupt. The watchdog timer can be reset by having the microprocessor perform a WRITE of the watchdog register. The time-out period then starts over. Should the watchdog timer time-out, a value of 00h needs to be written to the watchdog register in order to clear the IRQ/FT/OUT/SQW pin. This will also disable the watchdog function until it is again programmed correctly. A READ of the flags register will reset the watchdog flag (bit D7; register 0Fh). The watchdog function is automatically disabled upon power-up and the watchdog register is cleared. If the watchdog function is set, the frequency test function is activated, and the SQWE bit is '0,' the watchdog function prevails and the frequency test function is denied. Doc ID 10773 Rev 7 19/32 Clock operation M41T81S Square wave output The M41T81S offers the user a programmable square wave function which is output on the SQW pin. RS3-RS0 bits located in 13h establish the square wave output frequency. These frequencies are listed in Table 4. Once the selection of the SQW frequency has been completed, the IRQ/FT/OUT/SQW pin can be turned on and off under software control with the square wave enable bit (SQWE) located in register 0Ah. Table 4. Square wave output frequency Square wave bits Square wave RS3 RS2 RS1 RS0 Frequency Units 0 0 0 0 None - 0 0 0 1 32.768 kHz 0 0 1 0 8.192 kHz 0 0 1 1 4.096 kHz 0 1 0 0 2.048 kHz 0 1 0 1 1.024 kHz 0 1 1 0 512 Hz 0 1 1 1 256 Hz 1 0 0 0 128 Hz 1 0 0 1 64 Hz 1 0 1 0 32 Hz 1 0 1 1 16 Hz 1 1 0 0 8 Hz 1 1 0 1 4 Hz 1 1 1 0 2 Hz 1 1 1 1 1 Hz Century bit Bits D7 and D6 of clock register 03h contain the CENTURY ENABLE bit (CEB) and the CENTURY bit (CB). Setting CEB to a '1' will cause CB to toggle, either from a '0' to '1' or from '1' to '0' at the turn of the century (depending upon its initial state). If CEB is set to a '0,' CB will not toggle. 20/32 Doc ID 10773 Rev 7 M41T81S Clock operation Battery low warning The M41T81S automatically performs battery voltage monitoring upon power-up and at factory-programmed time intervals of approximately 24 hours. The battery low (BL) bit, bit D4 of flags register 0Fh, will be asserted if the battery voltage is found to be less than approximately 2.5 V. The BL bit will remain asserted until completion of battery replacement and subsequent battery low monitoring tests, either during the next power-up sequence or the next scheduled 24-hour interval. If a battery low is generated during a power-up sequence, this indicates that the battery is below approximately 2.5 volts and may not be able to maintain data integrity. Clock data should be considered suspect and verified as correct. A fresh battery should be installed. If a battery low indication is generated during the 24-hour interval check, this indicates that the battery is near end of life. However, data is not compromised due to the fact that a nominal VCC is supplied. In order to insure data integrity during subsequent periods of battery back-up mode, the battery should be replaced. The M41T81S only monitors the battery when a nominal VCC is applied to the device. Thus applications which require extensive durations in the battery backup mode should be powered-up periodically (at least once every few months) in order for this technique to be beneficial. Additionally, if a battery low is indicated, data integrity should be verified upon power-up via a checksum or other technique. Oscillator fail detection If the oscillator fail bit (OF) is internally set to '1,' this indicates that the oscillator has either stopped, or was stopped for some period of time and can be used to judge the validity of the clock and date data. In the event the OF bit is found to be set to '1' at any time other than the initial power-up, the STOP bit (ST) should be written to a '1,' then immediately reset to '0.' This will restart the oscillator. The following conditions can cause the OF bit to be set: ● The first time power is applied (defaults to a '1' on power-up). ● The voltage present on VCC is insufficient to support oscillation. ● The ST bit is set to '1.' ● External interference of the crystal. The OF bit will remain set to '1' until written to logic '0.' The oscillator must start and have run for at least 4 seconds before attempting to reset the OF bit to '0.' Oscillator fail interrupt enable If the oscillator fail interrupt bit (OFIE) is set to a '1,' the IRQ pin will also be activated. The IRQ output is cleared by resetting the OFIE or OF bit to '0' (not be reading the flags register). Doc ID 10773 Rev 7 21/32 Clock operation M41T81S Output driver pin When the FT bit, AFE bit, SQWE bit, and watchdog register are not set, the IRQ/FT/OUT/SQW pin becomes an output driver that reflects the contents of D7 of the calibration register. In other words, when D7 (OUT bit) and D6 (FT bit) of address location 08h are a '0,' then the IRQ/FT/OUT/SQW pin will be driven low. Note: The IRQ/FT/OUT/SQW pin is an open drain which requires an external pull-up resistor. Preferred initial power-on default Upon initial application of power to the device, the following register bits are set to a '0' state: watchdog register; AFE; ABE; SQWE; OFIE; and FT. The following bits are set to a '1' state: ST; OUT; OF; and HT (see Table 5). Table 5. Preferred default values Condition Initial power-up(2) Subsequent power-up (with battery backup)(3) ST HT Out FT 1 1 1 0 0 0 UC 1 UC 0 UC UC 1. BMB0-BMB4, RB0, RB1 2. State of other control bits undefined 3. UC = Unchanged 22/32 WATCHDOG register(1) OF OFIE 0 0 1 0 UC 0 UC UC AFE SQWE ABE Doc ID 10773 Rev 7 M41T81S 4 Maximum ratings Maximum ratings Stressing the device above the rating listed in the absolute maximum ratings table may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the operating sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Table 6. Absolute maximum ratings Sym Parameter TSTG Storage temperature (VCC off, oscillator off) VCC Supply voltage TSLD Lead solder temperature for 10 seconds VIO Input or output voltages Value Unit –55 to 125 °C –0.3 to 7 V SO8(1) 260 °C SOX18(2) 240 °C –0.3 to VCC + 0.3 V IO Output current 20 mA PD Power dissipation 1 W 1. For SO8 package, Lead-free (Pb-free) lead finish, reflow at peak temperature of 260 °C. The time above 255 °C must not exceed 30 seconds. 2. For SOX18 package, reflow at peak temperature of 240 °C. The time above 235 °C must not exceed 20 seconds. Caution: Negative undershoots below –0.3 volts are not allowed on any pin while in the battery backup mode. Doc ID 10773 Rev 7 23/32 DC and AC parameters 5 M41T81S DC and AC parameters This section summarizes the operating and measurement conditions, as well as the DC and AC characteristics of the device. The parameters in the following DC and AC Characteristic tables are derived from tests performed under the measurement conditions listed in the relevant tables. Designers should check that the operating conditions in their projects match the measurement conditions when using the quoted parameters. Table 7. Operating and AC measurement conditions Parameter Note: M41T81S Supply voltage (VCC) 2.7 to 5.5 V Ambient operating temperature (TA) –40 to 85 °C Load capacitance (CL) 100 pF Input rise and fall times ≤ 50 ns Input pulse voltages 0.2VCC to 0.8VCC Input and output timing ref. voltages 0.3VCC to 0.7VCC Output Hi-Z is defined as the point where data is no longer driven. Figure 15. AC measurement I/O waveform 0.8VCC 0.7VCC 0.3VCC 0.2VCC Table 8. AI02568 Capacitance Parameter(1)(2) Symbol CIN COUT(3) tLP Min Max Unit Input capacitance - 7 pF Output capacitance - 10 pF Low-pass filter input time constant (SDA and SCL) - 50 ns 1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested. 2. At 25 °C, f = 1 MHz 3. Outputs deselected 24/32 Doc ID 10773 Rev 7 M41T81S DC and AC parameters Table 9. Sym DC characteristics Test condition(1) Parameter Min Typ Max Unit ±1 µA 0 V ≤ VIN ≤ VCC ILI Input leakage current ILO Output leakage current ICC1 Supply current 0 V ≤ VOUT ≤ VCC ±1 µA Switch freq = 400 kHz 400 µA SCL = 0 Hz All inputs ≥ VCC – 0.2 V ≤ VSS + 0.2 V 100 µA ICC2 Supply current (standby) VIL Input low voltage –0.3 0.3VCC V VIH Input high voltage 0.7VCC VCC + 0.3 V VOL Output low voltage IOL = 3.0 mA 0.4 V Output low voltage (open drain)(2) IOL = 10 mA 0.4 V IRQ/OUT/FT/SQW 5.5 V 3.5(4) V 1 µA Pull-up supply voltage (open drain) VBAT(3) IBAT Backup supply voltage 2.0 TA = 25 °C, VCC = 0 V Oscillator ON, VBAT = 3 V Battery supply current 0.6 1. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 2.7 to 5.5 V (except where noted). 2. For IRQ/FT/OUT/SQW pin (open drain) 3. STMicroelectronics recommends the RAYOVAC BR1225 or BR1632 (or equivalent) as the battery supply. 4. For rechargeable back-up, VBAT (max) may be considered to be VCC. Table 10. Sym fO Crystal electrical characteristics Parameter(1)and(2) Resonant frequency Min - RS Series resistance - CL Load capacitance - Typ 32.768 Max Units kHz 60(3) kΩ 12.5 pF 1. Externally supplied if using the SO8 package. STMicroelectronics recommends the KDS DT-38: 1TA/1TC252E127, Tuning Fork Type (thru-hole) or the DMX-26S: 1TJS125FH2A212, (SMD) quartz crystal for industrial temperature operations. KDS can be contacted at [email protected] or http://www.kdsj.co.jp for further information on this crystal type. 2. Load capacitors are integrated within the M41T81S. Circuit board layout considerations for the 32.768 kHz crystal of minimum trace lengths and isolation from RF generating signals should be taken into account. 3. For applications requiring back-up supply operation below 2.5 V, RS (max) should be considered 40 kΩ. Figure 16. Power down/up mode AC waveforms VCC VSO tPD SDA SCL trec DON'T CARE AI00596 Doc ID 10773 Rev 7 25/32 DC and AC parameters Table 11. M41T81S Power down/up AC characteristics Symbol tPD Parameter(1)(2) SCL and SDA at VIH before power-down Min 0 Typ - Max - Unit nS trec SCL and SDA at VIH after power-up 10 - - µS 1. VCC fall time should not exceed 5 mV/µs. 2. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 2.7 to 5.5 V (except where noted). Table 12. Power down/up trip points DC characteristics Parameter(1)(2) Sym VPFD VSO Power-fail deselect Min Typ Max Unit 2.5 2.6 2.7 V Hysteresis Battery backup switchover voltage (VCC < VBAT; VCC < VPFD) 25 mV VBAT < VPFD VBAT V VBAT > VPFD VPFD V 40 mV Hysteresis 1. All voltages referenced to VSS. 2. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 2.7 to 5.5 V (except where noted). Figure 17. Bus timing requirements sequence SDA tBUF tHD:STA tR tHD:STA tF SCL tHIGH P S tLOW tSU:DAT tHD:DAT tSU:STA SR tSU:STO P AI00589 26/32 Doc ID 10773 Rev 7 M41T81S DC and AC parameters Table 13. AC characteristics Parameter(1) Sym Min Typ Max Units 0 - 400 kHz fSCL SCL clock frequency tLOW Clock low period 1.3 - µs tHIGH Clock high period 600 - ns tR SDA and SCL rise time - 300 ns tF SDA and SCL fall time - 300 ns tHD:STA START condition hold time (after this period the first clock pulse is generated) 600 - ns tSU:STA START condition setup time (only relevant for a repeated start condition) 600 - ns tSU:DAT Data setup time 100 - ns Data hold time 0 - µs STOP condition setup time 600 - ns Time the bus must be free before a new transmission can start 1.3 - µs tHD:DAT (2) tSU:STO tBUF 1. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 2.7 to 5.5 V (except where noted). 2. Transmitter must internally provide a hold time to bridge the undefined region (300 ns max) of the falling edge of SCL. Doc ID 10773 Rev 7 27/32 Package mechanical data 6 M41T81S Package mechanical data In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK® packages, depending on their level of environmental compliance. ECOPACK® specifications, grade definitions and product status are available at: www.st.com. ECOPACK® is an ST trademark. Figure 18. SO8 – 8-lead plastic small package outline h x 45° A2 A c ccc b e 0.25 mm GAUGE PLANE D k 8 E1 E 1 L A1 L1 SO-A Note: Drawing is not to scale. Table 14. SO8 – 8-lead plastic small outline (150 mils body width), package mechanical data mm inches Symb Typ Min A Typ Min 1.75 Max 0.069 A1 0.10 A2 1.25 b 0.28 0.48 0.011 0.019 c 0.17 0.23 0.007 0.009 ccc 0.25 0.004 0.010 0.049 0.10 0.004 D 4.90 4.80 5.00 0.193 0.189 0.197 E 6.00 5.80 6.20 0.236 0.228 0.244 E1 3.90 3.80 4.00 0.154 0.150 0.157 e 1.27 0.050 h 0.25 0.50 0.010 0.020 k 0° 8° 0° 8° L 0.40 0.127 0.016 0.050 L1 28/32 Max 1.04 0.041 Doc ID 10773 Rev 7 M41T81S Package mechanical data Figure 19. SOX18 – 18-lead plastic small outline, 300 mils, embedded crystal, outline SOX18 Note: Drawing is not to scale. Table 15. SOX18 – 18-lead plastic small outline, 300 mils, embedded crystal, package mechanical data millimeters inches Symbol Typ Min Max Typ Min Max A 2.57 2.44 2.69 0.101 0.096 0.106 A1 0.23 0.15 0.31 0.009 0.006 0.012 A2 2.34 2.29 2.39 0.092 0.090 0.094 B 0.46 0.41 0.51 0.018 0.016 0.020 c 0.25 0.20 0.31 0.010 0.008 0.012 D 11.61 11.56 11.66 0.457 0.455 0.459 E 7.62 7.57 7.67 0.300 0.298 0.302 E1 10.34 10.16 10.52 0.407 0.400 0.414 e 1.27 L 0.66 0.020 0.032 0.050 0.51 0.81 Doc ID 10773 Rev 7 0.026 29/32 Part numbering 7 M41T81S Part numbering Table 16. Ordering information Example: M41T 81S M 6 F Device type M41T Supply voltage and write protect voltage 81S = VCC = 2.7 to 5.5 V Package M = SO8 MY(1) = SOX18 Temperature range 6 = –40 °C to 85 °C Shipping method E = ECOPACK® package, tubes(2) F = ECOPACK® package, tape & reel 1. The SOX18 package includes an embedded 32,768 Hz crystal. Contact local ST sales office for availability. 2. Shipment in tubes is not recommended for new design. Contact local ST sales office for availability. For other options, or for more information on any aspect of this device, please contact the ST sales office nearest you. 30/32 Doc ID 10773 Rev 7 M41T81S 8 Revision history Revision history Date Revision Changes 22-Jan-2004 0.1 First draft 06-Feb-2004 0.2 Update BL information, characteristics, ratings, and Lead (Pb)-free information (Table 12, Table 6, Table 10, Table 16) 20-Feb-2004 0.3 Update characteristics (Table 11, Table 12, Table 7, Part numbering) 14-Apr-2004 1 05-May-2004 1.1 Update DC characteristics (Table 9) 16-Jun-2004 1.2 Add shipping package (Table 16) 13-Sep-2004 2 Update maximum ratings (Table 6) 26-Nov-2004 3 Promote document; update characteristics and marketing status (cover page, Figure 5) 23-Sep-2005 4 Update features; added Lead-free information (cover page; Figure 4) 22-Jan-2007 5 Remove TIMEKEEPER references and update package mechanical data (Figure 18 and Figure 19) 13-Sep-2010 6 Updated Section 4, ECOPACK® text in Section 6; reformatted document. 16-May-2012 7 Added reference to AN1572 in Power-down time-stamp on page 14; updated footnote 1 of Table 6; updated Table 16: Ordering information. Product promoted; reformatted; update characteristics, including Lead-free package information (Figure 3, Figure 4, Figure 11, Figure 14; Table 13, Table 16) Doc ID 10773 Rev 7 31/32 M41T81S Please Read Carefully: Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST’s terms and conditions of sale. Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the ST products and services described herein. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such third party products or services or any intellectual property contained therein. UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS EXPRESSLY APPROVED IN WRITING BY TWO AUTHORIZED ST REPRESENTATIVES, ST PRODUCTS ARE NOT RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY, DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. ST PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE GRADE" MAY ONLY BE USED IN AUTOMOTIVE APPLICATIONS AT USER’S OWN RISK. Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any liability of ST. ST and the ST logo are trademarks or registered trademarks of ST in various countries. Information in this document supersedes and replaces all information previously supplied. The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners. © 2012 STMicroelectronics - All rights reserved STMicroelectronics group of companies Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Philippines - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America www.st.com 32/32 Doc ID 10773 Rev 7