SERIES: PFR-2100 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
up to 2050 W continuous power
current limited to 5.125 A
blind mate connections for hot-swap
power factor correction
DROOP current sharing
single I/O connector for AC input, DC output & signals
remote on/off control, power good signal
front panel LED indicators
efficiency up to 93%
MODEL
PFR-2100-400
Notes:
1.
2.
3.
4.
output
voltage1
output
current
output
power2,3
ripple
and noise4
efficiency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
400
5.125
2050
1500
93
Vout adjustable to 100~410 Vdc.
At 100 Vdc output, maximum of 125 W; 1.25 A, 80 ohms load.
At 410 Vdc output, maximum of 2050 W.
With 2000 μF external capacitance
PART NUMBER KEY
PFR-2100 - 400 - CXX
Base Number
Output Voltage
cui.com
Reserved for Custom
Configurations
For more information, please visit the product page.
CUI Inc │ SERIES: PFR-2100 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY
date 02/01/2016 │ page 2 of 4
INPUT
parameter
conditions/description
min
voltage
typ
180
frequency
50
current
at 230 Vac
inrush current
at 230 Vac, 50 Hz, half cycle, cold start, 25°C
leakage current
power factor correction
at 230 Vac
0.96
0.99
conditions/description
min
typ
max
units
264
Vac
60
Hz
10.7
A
40
A
3.5
mArms
max
units
OUTPUT
parameter
total regulation
±2
transient response
25% step load, recovery to 1% within 5 ms, slew
rate 1A/µs
hold-up time
at 115/230 Vac, full load
17
parameter
conditions/description
min
remote enable
“active low” enables main output, last-mate / firstbreak enable pin
current share
passive droop with 1% regulation (for more than
12 units, consult Application Engineering)
Vprog (adjustability)
via 0 ~ 5.0 V signal for adjustment; unterminated
default @ 100 Vdc
%
5
%
ms
STATUS & CONTROL
LED indicator
typ
100
max
units
410
Vdc
max
units
AC OK open collector, active “high” =Good
DC OK open collector, active “high” =Good
PROTECTIONS
parameter
conditions/description
min
typ
over voltage protection
430
450
Vdc
over current protection
110
125
%
max
units
over temperature protection
output shut down, auto recovery
SAFETY & COMPLIANCE
parameter
conditions/description
min
safety approvals
cTUVus 60950-1 (designed to meet), CE (designed to meet)
emissions
FCC 15 Sub Part J, Class A, EN55022 Class A, VCCI Class A
harmonic compliance
EN61000-3-2 Class D
surges (mains)
IEC/EN 61000-4-5
voltage dips/interruptions
IEC/EN 61000-4-11
MTBF
as per Telcordia SR332, 40°C, full load
RoHS
2011/65/EU
cui.com
400,000
typ
hours
For more information, please visit the product page.
CUI Inc │ SERIES: PFR-2100 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY
date 02/01/2016 │ page 3 of 4
ENVIRONMENTAL
parameter
conditions/description
min
max
units
0
50
°C
-40
85
°C
operating temperature
storage temperature
typ
MECHANICAL
parameter
conditions/description
dimensions
11.50 x 5.20 x 2.50 (292.1 x 132.08 x 63.50 mm)
min
cooling / airflow
integral high performance 60 mm fan, air inlet at
face; exhaust at connector
input / output connector
FCI P/N 51939-377LF
mates with FCI 51940-263LF
hot-swap capability
fully hot-swappable, blind mate connector
typ
max
units
inches
MECHANICAL DRAWING
units: inches [mm]
tolerance:
X.XX ±0.02 [0.50]
X.XXX ±0.010 [0.25]
INPUT / OUTPUT CONNECTOR1
Pins
Function
Pins
Function
Pins
Function
Pins
Function
Pins
Function
Pins
Function
Pins
Function
P2
-Vout
A1
Reserved
A2
DC_OK_L
A3
Reserved
A4
OTP
A5
Enable
(Return)
A6
Ref (OVP/
UVP test)
P4
+ Vout
B1
Reserved
B2
N/C
B3
N/C
B4
N/C
B5
Test-Pin 5
B6
Test-Pin 3
P6
Earth
Ground
C1
Logic
Return
C2
Reserved
C3
N/C
C4
N/C
C5
N/C
C6
Test-Pin 4
P8
AC
Neutral
D1
PS Present
D2
AC_OK_L
D3
V
program
D4
Reserved
D5
-VE Sense
D6
Enable
P10
AC Line
--
--
--
--
--
--
--
--
--
--
--
--
Note:
1. Power Blades P1, P3, P5, P7 & P9 omitted for isolation
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PFR-2100 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY
date 02/01/2016 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
05/07/2015
1.01
updated datasheet
02/01/2016
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.