For more information, please visit the product page. date 02/01/2016 page 1 of 4 SERIES: PFR-2100 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY FEATURES • • • • • • • • • up to 2050 W continuous power current limited to 5.125 A blind mate connections for hot-swap power factor correction DROOP current sharing single I/O connector for AC input, DC output & signals remote on/off control, power good signal front panel LED indicators efficiency up to 93% MODEL PFR-2100-400 Notes: 1. 2. 3. 4. output voltage1 output current output power2,3 ripple and noise4 efficiency (Vdc) max (A) max (W) max (mVp-p) typ (%) 400 5.125 2050 1500 93 Vout adjustable to 100~410 Vdc. At 100 Vdc output, maximum of 125 W; 1.25 A, 80 ohms load. At 410 Vdc output, maximum of 2050 W. With 2000 μF external capacitance PART NUMBER KEY PFR-2100 - 400 - CXX Base Number Output Voltage cui.com Reserved for Custom Configurations For more information, please visit the product page. CUI Inc │ SERIES: PFR-2100 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY date 02/01/2016 │ page 2 of 4 INPUT parameter conditions/description min voltage typ 180 frequency 50 current at 230 Vac inrush current at 230 Vac, 50 Hz, half cycle, cold start, 25°C leakage current power factor correction at 230 Vac 0.96 0.99 conditions/description min typ max units 264 Vac 60 Hz 10.7 A 40 A 3.5 mArms max units OUTPUT parameter total regulation ±2 transient response 25% step load, recovery to 1% within 5 ms, slew rate 1A/µs hold-up time at 115/230 Vac, full load 17 parameter conditions/description min remote enable “active low” enables main output, last-mate / firstbreak enable pin current share passive droop with 1% regulation (for more than 12 units, consult Application Engineering) Vprog (adjustability) via 0 ~ 5.0 V signal for adjustment; unterminated default @ 100 Vdc % 5 % ms STATUS & CONTROL LED indicator typ 100 max units 410 Vdc max units AC OK open collector, active “high” =Good DC OK open collector, active “high” =Good PROTECTIONS parameter conditions/description min typ over voltage protection 430 450 Vdc over current protection 110 125 % max units over temperature protection output shut down, auto recovery SAFETY & COMPLIANCE parameter conditions/description min safety approvals cTUVus 60950-1 (designed to meet), CE (designed to meet) emissions FCC 15 Sub Part J, Class A, EN55022 Class A, VCCI Class A harmonic compliance EN61000-3-2 Class D surges (mains) IEC/EN 61000-4-5 voltage dips/interruptions IEC/EN 61000-4-11 MTBF as per Telcordia SR332, 40°C, full load RoHS 2011/65/EU cui.com 400,000 typ hours For more information, please visit the product page. CUI Inc │ SERIES: PFR-2100 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY date 02/01/2016 │ page 3 of 4 ENVIRONMENTAL parameter conditions/description min max units 0 50 °C -40 85 °C operating temperature storage temperature typ MECHANICAL parameter conditions/description dimensions 11.50 x 5.20 x 2.50 (292.1 x 132.08 x 63.50 mm) min cooling / airflow integral high performance 60 mm fan, air inlet at face; exhaust at connector input / output connector FCI P/N 51939-377LF mates with FCI 51940-263LF hot-swap capability fully hot-swappable, blind mate connector typ max units inches MECHANICAL DRAWING units: inches [mm] tolerance: X.XX ±0.02 [0.50] X.XXX ±0.010 [0.25] INPUT / OUTPUT CONNECTOR1 Pins Function Pins Function Pins Function Pins Function Pins Function Pins Function Pins Function P2 -Vout A1 Reserved A2 DC_OK_L A3 Reserved A4 OTP A5 Enable (Return) A6 Ref (OVP/ UVP test) P4 + Vout B1 Reserved B2 N/C B3 N/C B4 N/C B5 Test-Pin 5 B6 Test-Pin 3 P6 Earth Ground C1 Logic Return C2 Reserved C3 N/C C4 N/C C5 N/C C6 Test-Pin 4 P8 AC Neutral D1 PS Present D2 AC_OK_L D3 V program D4 Reserved D5 -VE Sense D6 Enable P10 AC Line -- -- -- -- -- -- -- -- -- -- -- -- Note: 1. Power Blades P1, P3, P5, P7 & P9 omitted for isolation cui.com For more information, please visit the product page. CUI Inc │ SERIES: PFR-2100 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY date 02/01/2016 │ page 4 of 4 REVISION HISTORY rev. description date 1.0 initial release 05/07/2015 1.01 updated datasheet 02/01/2016 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.