For more information, please visit the product page. date 06/10/2016 page 1 of 4 SERIES: PSE-1000 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY FEATURES up to 1000 W continuous power 1U x 2U package I2C communication for monitoring and control blind mate connections for hot-swap redundant (N+1) operation power factor correction 3.3 Vdc (0.5A) standby voltage DROOP current sharing or forced current sharing (optional) single I/O connector for AC input, DC output & signals remote on/off control, power good signal efficiency up to 90% o of N C rt . T Rheinla nd UV , I nc • • • • • • • • • • • h A ca meri US MODEL PSE-1000-54 Notes: output voltage output current output power ripple and noise efficiency1 (Vdc) max (A) max (W) max (mVp-p) typ (%) 54 18.50 1000 540 90 1. At 230 Vac input. PART NUMBER KEY PSE-1000 - 54 - CXX Base Number Output Voltage cui.com Reserved for Custom Configurations For more information, please visit the product page. CUI Inc │ SERIES: PSE-1000 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY date 06/10/2016 │ page 2 of 4 INPUT parameter conditions/description min voltage typ 90 frequency 50 current at 90 Vac inrush current half cycle, cold start, 25°C at 115 Vac, 60 Hz at 230 Vac, 50 Hz leakage current power factor correction 0.95 0.98 min typ max units 264 Vac 60 Hz 13.2 A 20 40 A A 1.5 mArms max units OUTPUT - V1 (MAIN OUTPUT) parameter conditions/description total regulation ±3 transient response 25% step load, recovery to 1% within 1 ms, slew rate 1 A/μs hold-up time full load in redundant operation % 3 12 20 % ms ms OUTPUT - V2 (STANDBY OUTPUT) parameter conditions/description min output voltage typ max 3.3 output current 0 ripple and noise total regulation units Vdc 0.5 A 33 mVp-p ±2.5 % STATUS & CONTROL parameter conditions/description I2C interface SCL 100 kHz clock rate, SDA data line remote sense main output remote enable “active low” enable main output, last-mate/ firstbreak enable pin current share droop share, active current share option status AC OK, DC OK, and OTP_OK (open collector, active “low” =OK); and PS_Present LED indicator AC OK & DC OK indicators min typ max units min typ max units 60 Vdc % 120 % max units PROTECTIONS parameter conditions/description over voltage protection V1 V2 over current protection latching; shutdown after 2 s over temperature protection output shut down, auto recovery 115 SAFETY & COMPLIANCE parameter conditions/description min safety approvals cTUVus UL60950-1, CE (LVD) emissions FCC 15 Sub Part J, Class A, EN55022 Class A harmonic compliance EN61000-3-2 Class A surges (mains) IEC/EN 61000-4-5 voltage dips/interruptions IEC/EN 61000-4-11 cui.com typ For more information, please visit the product page. CUI Inc │ SERIES: PSE-1000 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY date 06/10/2016 │ page 3 of 4 SAFETY & COMPLIANCE (CONTINUED) parameter conditions/description MTBF as per Telcordia SR332, 40°C, full load min RoHS 2011/65/EU typ max units 500,000 hours ENVIRONMENTAL parameter conditions/description min operating temperature storage temperature max units 0 typ 55 °C -40 85 °C max units MECHANICAL parameter conditions/description min dimensions 10.00 x 3.30 x 1.60 (254.0 x 83.8 x 40.6 mm) cooling / airflow integral high performance 38 mm fan air inlet at face; exhaust at connector input / output connector FCI P/N 51939-420LF mates with FCI P/N 51762-10602000AALF hot-swap capability fully hot-swappable, blind mate connector typ inches MECHANICAL DRAWING units: inches [mm] tolerance: X.XX ±0.02 [0.50] X.XXX ±0.010 [0.25] INPUT / OUTPUT CONNECTOR Pins Function Pins Function Pins Function Pins Function Pins Function Pins Function Pins Function P1 +54 V A1 +V1 Sense A2 EEPROM A0 A31 N/C A4 AC OK A5 Signal Return A6 +3.3 VSB Return P2 -54 V B1 -V1 Sense B2 EEPROM A1 B31 N/C B4 DC OK B5 EEPROM Clock SCL B6 +3.3 VSB Adj. P3 FG C1 ISHARE C2 EEPROM A2 C31 N/C C4 PS_PRESENT C5 EEPROM Data (SDA) C6 Spare P4 AC Neutral D1 V Program D2 N/C D31 N/C D4 OTP OK D5 +3.3 VSB D6 Enable (short pin) P5 AC Line -- -- -- -- -- -- -- -- -- -- -- -- Note: 1. POE Isolation Barrier - No traces to be routed between these pins and any others. cui.com For more information, please visit the product page. CUI Inc │ SERIES: PSE-1000 │ DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY date 06/10/2016 │ page 4 of 4 REVISION HISTORY rev. description date 1.0 initial release 05/06/2015 1.01 updated datasheet 06/10/2016 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.