SERIES: VMS-365 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
•
•
up to 365 W continuous power
industry standard 3" x 5" footprint
18 W/in3 power density
universal input (85-264 Vac / 125-373 Vdc)
single output from 12 to 48 V
active power correction (98%)
12 V auxiliary fan output, 5 V standby
no minimum load required
over load, over voltage, and short circuit protections
full medical and ITE safety approvals
efficiency up to 90%
V
DE
output
voltage
output
current
output
power1
ripple and
noise2
efficiency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VMS-365-12
12
30.4
365
120
90
VMS-365-24
24
15.2
365
240
90
VMS-365-48
48
7.6
365
480
90
MODEL
Notes:
1. Total continuous output power will not exceed 365 W forced air (400 LFM), 200 W without fan
2. Measured at 20 MHz, twisted pair with 0.47 μF ceramic and 22 μF tantalum parallel capacitors
PART NUMBER KEY
VMS-365 - XX
Base Number
Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VMS-365 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/16/2013 │ page 2 of 5
INPUT
parameter
conditions/description
min
voltage
frequency
current
max
units
90
125
typ
264
373
Vac
Vdc
47
63
Hz
5
2.5
A
A
max
units
at 90 Vac, cold start
at 180 Vac, cold start
inrush current
no damage at 230 Vac, full load, cold start
power factor
measured at full load and 115 Vac/60 Hz and
230 Vac/50 Hz input source, coming impedance
will be less than 0.25Ω, compliant to EN61000-3-2
for harmonic currents
0.9
0.98
parameter
conditions/description
min
typ
line regulation
low line to high line
load regulation
all other outputs
12 V aux. output
5 V SB
OUTPUT
temperature coefficient
transient response
%
±1
±15
±5
%
%
%
0.25
mV/°C
25% Imax to Imax , 0.1 A/μs slew rate, ±5% max. deviation, 10 ms recovery
start-up time
500
rise time
hold-up time
±1
ms
0.2
115 Vac /60 Hz
adjustability
fan drive
12 Vdc / 500 mA for external fan
standby
5 Vdc, 2A (400 LFM forced air) / 1A (convection)
20
ms
16.6
ms
±5
%
PROTECTIONS
parameter
conditions/description
min
typ
over voltage protection
over current protection
automatically recovers
short circuit protection
auto recovery with no damage from a short on any output
max
units
130
%
150
%
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
primary to secondary (for 1 second):
primary to earth ground (for 1 second):
safety approvals
UL 60950-1/60601-1, VDE EN60950-1/EN60601-1,
CCC
EMI/EMC
EN55022:1998 (CISPR 22 class A conducted),
EN61000-3-2: 2000, EN61000-3-3: A1:2001,
EN55024 (IEC61000-4-2: 1995, IEC61000-4-3: 1995,
IEC61000-4-4: 1995, IEC61000-4-5: 1995,
IEC61000-4-6: 1996, IEC61000-4-11: 1994), CE
leakage current
measured per IEC 60950-1, paragraph 5.1,
test voltage of 120 Vac/60 Hz
test voltage of 230 Vac / 60 Hz
MTBF
with 400 LFM forced air, MIL-HDBK-217E-1, 75%
of rated full load, 25°C ambient
RoHS
2011/65/EU
cui.com
typ
5,656
5,656
Vdc
Vdc
0.110
0.275
300,000
mA
mA
hrs
For more information, please visit the product page.
CUI Inc │ SERIES: VMS-365 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/16/2013 │ page 3 of 5
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
operating humidity
non-condensing
typ
max
units
-20
50
°C
-40
80
°C
8
90
%
95
%
storage humidity
shock
operating (11 ms, half sine, for a total of 6 shock inputs)
non-operating (2 ms, half sine, for a total of 6 shock inputs)
10
140
G
G
vibration
operating (10 ~ 300 Hz, 1 hour per axis, 3 hours total)
non-operating (10 ~ 500 Hz, 1 hour per axis, 3 hours total)
1
2
Grms
Grms
DERATING CURVES
output power vs. ambient temperature
Load (%)
100
2
80
60
54
1
1
Convection
2
Forced air (400 LFM)
40
20
4
-20
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
APPLICATION NOTES
1. P/S ON
Logic Table
Negative Logic
SW Closed (VPSON <2.5 V)
Output on
SW Open (VPSON >2.5 Vor Open Circuit
Output off
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VMS-365 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/16/2013 │ page 4 of 5
2. Power OK
The POK pin of CN3 shall change from STATE (<400mV) to the high STATE (>4.5V) 100-500 ms after the main outputs are within
the regulation limits. Conversely, the POK should be de-asserted to a low srare when any of the main output voltages fall below
its under-voltage threshold, or when the main power has been removed for a time sufficiently long such that the power supply
operation cannot be guaranteed beyond the power-down warning time. The power down warning time must be 1mS minimum.
The electrical characteristics for the Power OK output driver are shown below.
POWER OK SIGNAL CHARACTERISTICS
Signal Type
+5 V TTL Compatible
Logic Level Low
< 0.4 V while Sinking a maximum of 10 mA
Logic Level High
Between 2.4 V and 5 V Output while Sourcing 200 μA
High State Output Impedance
1 K Pull-Up from +5 Vsb to Termination Point
Max. Low Level Surge Current
56 mA for 5μS with a 500 mS on/150 mS off duty cycle
MECHANICAL DRAWING
Ø4.04[Ø0.159]
MOUNTING HOLE
TYP 4 PLCS
MOLEX (90130-1108)
C-GRID III SHROUDED HEADER
VERTICAL, DUAL ROW, 8 PIN
0.10" PITCH
MATING CONNECTOR:
MOLEX (90142-0008)
CN1
127.00 5.000
115.60 4.551
A
AC Line
2
AC Neutral
INPUT SPADE CONNECTOR
Gnd
64.80 2.551
MOLEX (39-28-1123)
MINIFIT JR., VERTICAL DUAL
ROW CONNECTOR, 12 PIN
0.165" PITCH
MATING CONNECTOR:
MOLEX (39-01-2120)
Ø6.35[Ø0.250]
MAX DIA OF
MOUNTING HARDWARE
TYP 4 PLCS
1
76.40 3.008
2
CN2
1
J1
MOLEX (26-60-4030)
3 PIN, CTR PIN REMOVED
0.156" SPACING
QUICK DISCONNECT TAB
6.35[0.250] X 0.81[0.032]
MOLEX (19705-4301)
29.60 1.17
35.65 1.40
MAX
4.40 0.17 MAX
SMT COMPONENT
HEIGHT
J3
4
3
2
1
8
7
6
5
7
8
9
10
11
12
DETAIL A
SCALE 1 : 1
cui.com
1
V1
2
V1
3
V1
4
V1
5
V1
6
V1
7
DC Returns
8
DC Returns
9
DC Returns
10
DC Returns
11
DC Returns
12
DC Returns
CN3
1
2
3
4
5
6
J2
AC Ground
1
+5V Aux
2
FAN-
3
RS+
4
FAN+
5
P OK
6
PS ON
7
RS-
8
-5V Aux GND
For more information, please visit the product page.
CUI Inc │ SERIES: VMS-365 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/16/2013 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
05/13/2011
1.01
new template applied
08/01/2011
1.02
V-Infinity branding removed
08/22/2012
1.03
updated drawing
04/18/2013
added CCC safety approval
12/16/2013
1.04
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.