データシート

For more information, please visit the product page.
date
02/12/2015
page
1 of 7
SERIES: VQA │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
designed for IGBT driver modules
small footprint
3,000 Vac isolation
short circuit protection
temperature range (-40~105°C)
UL 60950-1 approval
efficiency up to 80%
MODEL
input
voltage
output
voltage
output
current
ripple
and noise2
efficiency3
(Vdc)
max
(mA)
max
(mVp-p)
typ
(%)
typ
(Vdc)
range
(Vdc)
VQA-S9-D15-SIP1
12
9~15
15
-8
100
-80
200
80
VQA-S12-D15-SIP1
12
11.6~12.4
15
-8.7
80
-40
200
80
VQA-S15-S9-SIP
15
14.5~15.5
9
111
200
80
55
-55
200
80
VQA-S15-D9-SIP
15
14.5~15.5
9
-9
VQA-S15-D15-SIP1
15
14.5~15.5
15
-8.7
80
-40
200
80
VQA-S15-D17-SIP1
15
14.5~15.5
17
-8.7
80
-40
200
80
VQA-S24-D15-SIP1
24
23.3~24.7
15
-8.7
80
-40
200
80
Notes:
1. UL approved
2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
3. at full load
PART NUMBER KEY
VQA-SXX-XXX-SIP
Base Number
Input Voltage
Output
S = Single
D = Dual
cui.com
Output Voltage
For more information, please visit the product page.
CUI Inc │ SERIES: VQA │ DESCRIPTION: DC-DC CONVERTER
date 02/12/2015 │ page 2 of 7
INPUT
parameter
conditions/description
min
typ
max
units
input voltage
VQA-S9-D15-SIP
VQA-S12-D15-SIP
VQA-S24-D15-SIP
all other models
9
11.6
23.3
14.5
12
12
24
15
15
12.4
24.7
15.5
Vdc
Vdc
Vdc
Vdc
surge voltage
VQA-S9-D15-SIP
VQA-S12-D15-SIP
VQA-S24-D15-SIP
all other models
-0.7
-0.7
-0.7
-0.7
15
13
26
16
Vdc
Vdc
Vdc
Vdc
temperature coefficient
at full load
±0.03
%/°C
max
units
200
μF
OUTPUT
parameter
conditions/description
min
typ
capacitive load
line regulation
for Vin change of ±1%
1.2
1.5
%
switching frequency
at full load, nominal input
100
200
kHz
typ
max
units
1
s
max
units
PROTECTIONS
parameter
conditions/description
min
short circuit protection1
Notes:
1. The supply voltage must be discontinued at the end of the short circuit duration
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute at 1 mA max. leakage
3,000
isolation resistance
input to output at 500 Vdc
1,000
isolation capacitance
input to output, 100 kHz/0.1 V
safety approvals
UL 60950-1
conducted emissions
CISPR22/EN55022, class B, external circuit required (see figure 1)
radiated emissions
CISPR22/EN55022, class B, external circuit required (see figure 1)
ESD
IEC/EN61000-4-2, contact ±8kV, class B
MTBF
as per MIL-HDBK-217F @ 25°C
RoHS
2011/65/EU
2
Notes:
min
typ
Vac
MΩ
6.6
pF
3,500,000
hours
2. See specific models listed on page 1
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-40
105
°C
-55
125
°C
95
%
max
units
300
°C
storage temperature
storage humidity
typ
non-condensing
SOLDERABILITY
parameter
conditions/description
hand soldering
1.5mm from case for 10 seconds
min
cui.com
typ
For more information, please visit the product page.
CUI Inc │ SERIES: VQA │ DESCRIPTION: DC-DC CONVERTER
date 02/12/2015 │ page 3 of 7
MECHANICAL
parameter
conditions/description
dimensions
19.50 x 9.80 x 12.5 (0.768 x 0.386 x 0.492 inch)
min
material
plastic (UL94V-0)
typ
Ta=25°C
4.3
g
25
°C
MECHANICAL DRAWING
units: mm [inches]
tolerance: ±0.50 [±0.020]
pin section tolerance: ±0.10 [±0.004]
PIN CONNECTIONS
PIN
FUNCTION
1
Vin
2
GND
5*
-Vo
6
0V
7
+Vo
Grid size: 2.54mm x 2.54mm
Note: *VQA-S15-S9-SIP has no connection
Top View
PCB LAYOUT
Front View
Bottom View
DERATING CURVES
Temperature Derating Curve
Load (%)
100
80
60
Safe operating area
40
20
-40
-20
0
20
40
60
85
Ambient Temperature (°C)
cui.com
units
mm
weight
temperature rise
max
105
120
For more information, please visit the product page.
CUI Inc │ SERIES: VQA │ DESCRIPTION: DC-DC CONVERTER
date 02/12/2015 │ page 4 of 7
PERFORMANCE CURVES
2. output current vs. output voltage
20
90
18
80
16
70
14
Voltage VO1 (V)
Efficiency η (%)
1. output current vs. efficiency
100
60
50
40
30
12
10
8
6
20
4
10
2
0
0
8
16
24
32
40
48
56
64
72
80
0
88
0
8
16
24
32
Current IO1 (mA)
100
20
90
18
80
16
70
14
60
50
40
30
40
50
60
70
80
90
0
100
0
10
20
30
Current IO1 (mA)
18
80
16
70
14
Voltage VO1 (V)
Efficiency η (%)
20
90
60
50
40
30
50
60
70
80
90
100
80
90
100
6
2
40
70
8
4
30
60
10
10
20
50
12
20
10
40
VQA-S15-D17-SIP
100
0
88
Current IO1 (mA)
VQA-S15-D17-SIP
0
80
6
2
30
72
8
4
20
64
10
10
10
56
12
20
0
48
VQA-S12-D15-SIP, VQA-S15-D15-SIP, VQA-S24-D15-SIP
Voltage VO1 (V)
Efficiency η (%)
VQA-S12-D15-SIP, VQA-S15-D15-SIP, VQA-S24-D15-SIP
0
40
Current IO1 (mA)
80
90
0
100
Current IO1 (mA)
0
10
20
30
40
50
60
70
Current IO1 (mA)
VQA-S9-D15-SIP
VQA-S9-D15-SIP
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VQA │ DESCRIPTION: DC-DC CONVERTER
date 02/12/2015 │ page 5 of 7
PERFORMANCE CURVES (CONTINUED)
1. output current vs. efficiency
2. output current vs. output voltage
18
80
16
70
14
Voltage VO1 (V)
20
90
Efficiency η (%)
100
60
50
40
30
12
10
8
6
20
4
10
2
0
0
10
20
30
40
50
60
70
80
90
0
100
0
10
20
30
Current IO1 (mA)
16
70
14
Voltage VO1 (V)
18
80
Efficiency η (%)
20
90
60
50
40
30
50
60
100
80
90
100
6
2
40
90
8
4
30
80
10
10
20
70
12
20
10
60
VQA-S15-S9-SIP
100
0
50
Current IO1 (mA)
VQA-S15-S9-SIP
0
40
70
80
90
0
100
0
10
20
30
Current IO1 (mA)
40
50
60
70
Current IO1 (mA)
VQA-S15-D9-SIP
VQA-S15-D9-SIP
EMC RECOMMENDED CIRCUIT
Table 1
LD M
Vi n
Vin
Figure 1
Recommended external circuit components
+Vo
EUT
C1
G ND
GN D
L O AD
Vin
(Vdc)
C1
LDM
12
4.7μF/50V
12μH
15
4.7μF/50V
12μH
24
4.7μF/50V
12μH
-Vo
(0 V)
TEST CONFIGURATION
Figure 2
1
Vin
C1
+
Vin
EUT
2
GND
+Vo
7
1
0V
6
-Vo
5
C3
+
A
V
Load
Vin
+
C1
EU T 0V
2
C1, C2, C3: 100 μF/35V (low impedance)
cui.com
+Vo
Vin
GND
-Vo
7
C2
6
5
+
A
V
Load
For more information, please visit the product page.
CUI Inc │ SERIES: VQA │ DESCRIPTION: DC-DC CONVERTER
date 02/12/2015 │ page 6 of 7
APPLICATION CIRCUIT
IGBT
Driver
Control Singal
1
Figure 3
Vin
C1
2
Vin
+Vo
7
EUT
0V
6
GND -Vo
5
Rg
IGBT
C2
C3
C1: 100 μF/35V (low impedance)
C2: 100 μF/35V (low impedance)
C3: 100 μF/35V (low impedance)
Notes:
1.
2.
3.
4.
The wire between the converter and IGBT driver must as short as possible.
External filter capacitors should be connected as close as possible to the converter and the IGBT driver.
The output average power of the IGBT driver should be less than the output power of DC-DC module.
Maximum capacitive load is tested at nominal input voltage and full load.
Note:
1. All specifications are measured at Ta=25°C, humidity <75%, nominal input voltage and rated output load unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VQA │ DESCRIPTION: DC-DC CONVERTER
date 02/12/2015 │ page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
08/16/2012
1.01
updated features
09/20/2012
1.02
updated product photograph
11/13/2012
1.03
various updates
02/05/2013
1.04
added switching frequency to spec
07/01/2013
1.05
added models, updated spec
09/23/2013
1.06
added UL to some models
02/12/2015
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.