MEANWELL Q

Q-120
120W Quad Output Switching Power Supply
series
Features :
AC input range selected by switch
Protections: Short circuit / Overload / Over voltage
100% full load burn-in test
Fixed switching frequency at 25KHz
2 years warranty
SPECIFICATION
Q-120B
MODEL
OUTPUT
Q-120C
Q-120D
OUTPUT NUMBER
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
5V
12V
-5V
-12V
5V
15V
-5V
-15V
5V
12V
24V
-12V
RATED CURRENT
11A
4A
1A
1A
10A
3.5A
1A
1A
8A
2A
2A
1A
CURRENT RANGE
2 ~ 12A
0.5 ~ 5A
0.2 ~ 1A
0.2 ~ 1A
2 ~ 12A
0.5 ~ 5A
0.2 ~ 1A
0.2 ~ 1A
2 ~ 12A
0.2 ~ 5A
0.2 ~ 2A
0.2 ~ 1A
RATED POWER
120W
122.5W
124W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 120mVp-p 80mVp-p 150mVp-p 80mVp-p 150mVp-p 80mVp-p 120mVp-p 180mVp-p 120mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
2.0%
6.0%
6.0%
6.0%
2.0%
+10,-5%
6.0%
+10,-5%
2.0%
6.0%
6.0%
6.0%
LINE REGULATION
0.5%
1.0%
1.0%
1.0%
0.5%
1.0%
1.0%
1.0%
0.5%
1.0%
1.0%
1.0%
LOAD REGULATION
0.5%
5.0%
5.0%
5.0%
0.5%
6.0%
5.0%
6.0%
0.5%
5.0%
5.0%
5.0%
VOLTAGE TOLERANCE Note.3
SETUP, RISE, HOLD UP TIME 200ms, 50ms, 20ms at full load
INPUT
VOLTAGE RANGE
88 ~ 132VAC/176 ~ 264VAC selected by switch
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
77%
AC CURRENT
INRUSH CURRENT (max.)
2.8A/115VAC
1.6A/230VAC
COLD START 35A
240 ~ 370VDC
76%
LEAKAGE CURRENT
<3.5mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
80%
CH1:5.75 ~ 6.75VDC
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, CCC GB4943 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
NOTE
DIMENSION
PACKING
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
261.4K hrs min. MIL-HDBK-217F (25
199*110*50mm (L*W*H)
0.86Kg; 16pcs/14.7Kg/0.95CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:Q-120-SPEC 2010-10-18
Q-120
120W Quad Output Switching Power Supply
Mechanical Specification
Case No. 906
series
Unit:mm
192
5
172
3.5
12
6
100
1
9.5
2
3
97
110
4
8.2
5
6
5-M3
7
37
8
Terminal Pin No. Assignment
Pin No.
1
2
3
4,5
199
6
6.5
3.5
50
3M3
20
Pin No.
6
7
8
Assignment
DC OUTPUT -V1
DC OUTPUT COM
DC OUTPUT +V1
20
12
24.5
3.5
MODEL
25
16.5
190.5
Assignment
AC/L
AC/N
FG
DC OUTPUT
Q-120B Q-120C Q-120D
Pin No.
4
5
+12V
-12V
+15V
-15V
+24V
+12V
159
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
Block Diagram
230
115
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
+V2
-V1
+V1
COM
O.L.P.
O.V.P.
FG
DRIVER
fosc : 83KHz
-V2
PWM
CONTROL
Derating Curve
Static Characteristics (B)
Ta=25
100
OUTPUT VOLTAGE (V)
12V
80
LOAD (%)
60
40
20
-10
-10
300
5.2
0
0
10
20
30
40
50
45
AMBIENT TEMPERATURE ( )
60
55
(VERTICAL)
(HORIZONTAL)
250
12
5.0
11
4.8
200
10
4.6
150
9
4.4
8
4.2
7
4.0
5V
100
+12V
-12V
-5V
+5V
80
160
85
170
90
180
95
190
100
200
105
210
110
220
115
230
120
240
125
250
50
25
OUTPUT RIPPLE (mVp-p)
13
130
260
INPUT VOLTAGE (V) 60Hz
File Name:Q-120-SPEC 2010-10-18