T- 6 0 60W Triple Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on Fixed switching frequency at 50KHz 2 years warranty SPECIFICATION MODEL OUTPUT INPUT T-60A CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 5A 2.5A 0.5A 5A 2.5A 0.5A 5A 2A 0.5A CURRENT RANGE 0.5 ~ 7A 0.2 ~ 3.5A 0 ~ 1A 0.5 ~ 7A 0.2 ~ 3.5A 0 ~ 1A 0.5 ~ 7A 0.2 ~ 3A 0 ~ 1A RATED POWER 57.5W 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p CH1 : 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 6.0% CH1 : 4.75 ~ 5.5V 2.0% 6.0% 6.0% 6.0% 100mVp-p CH1 : 4.75 ~ 5.5V 2.0% 6.0% 6.0% LINE REGULATION 0.5% 1.0% 0.5% 0.5% 1.0% 0.5% 0.5% 1.0% 0.5% LOAD REGULATION 1.0% 4.0% 1.0% 1.0% 4.0% 1.0% 1.0% 4.0% 1.0% SETUP, RISE TIME 300ms, 50ms/230VAC HOLD UP TIME (Typ.) 80ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 72% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2A/115VAC 1A/230VAC COLD START 20A/115VAC LEAKAGE CURRENT <3.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE 800ms, 50ms/115VAC at full load 10ms/115VAC at full load 120 ~ 370VDC 72% 72% 40A/230VAC 5V: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012, UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT / 70% RH Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 281.1K hrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) 0.55Kg; 24pcs/14.1Kg/0.75CUFT DIMENSION PACKING NOTE 62.5W 100mVp-p VOLTAGE ADJ. RANGE WORKING TEMP. OTHERS 61W RIPPLE & NOISE (max.) Note.2 100mVp-p OVER VOLTAGE (Note 4) T-60C CH1 PROTECTION EMC T-60B OUTPUT NUMBER ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:T-60-SPEC 2010-10-18 T- 6 0 60W Triple Output Switching Power Supply Mechanical Specification Case No. 901 series Unit:mm 3.5 7 152.5 1 3 84.5 8.2 4 5 2-M 6 97 65 9.5 2 3 7 3.5 4.5 78 24 159 150 6.5 22 Assignment AC/L AC/N FG DC OUTPUT -V Pin No. 1 2 3 4 38 M3 3.5 28.5 9 3.5 3- 18 18.5 9 Terminal Pin No. Assignment Assignment Pin No. DC OUTPUT +V2 5 DC OUTPUT COM 6 DC OUTPUT +V1 7 117 RECTIFIERS & FILTER Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING FG O.L.P. fosc : 50KHz -V REGULATOR RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT PWM CONTROL O.V.P. Derating Curve Static Characteristics (B) Ta=25 80 LOAD (%) 60 40 20 5.2 12 5.0 +12V +5V 300 250 -12V 11 4.8 200 10 4.6 150 9 4.4 100 8 4.2 7 4.0 +12V +5V 50 25 OUTPUT RIPPLE (mVp-p) OUTPUT VOLTAGE (V) 100 13 -12V -10 -10 0 0 10 20 30 40 50 45 AMBIENT TEMPERATURE ( ) 60 55 (VERTICAL) (HORIZONTAL) 60 80 100 120 140 160 180 200 220 240 260 INPUT VOLTAGE (V) 60Hz File Name:T-60-SPEC 2010-10-18