MEANWELL T

T- 6 0
60W Triple Output Switching Power Supply
series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
Fixed switching frequency at 50KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT
INPUT
T-60A
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
DC VOLTAGE
5V
12V
-5V
5V
12V
-12V
5V
15V
-15V
RATED CURRENT
5A
2.5A
0.5A
5A
2.5A
0.5A
5A
2A
0.5A
CURRENT RANGE
0.5 ~ 7A
0.2 ~ 3.5A
0 ~ 1A
0.5 ~ 7A
0.2 ~ 3.5A
0 ~ 1A
0.5 ~ 7A
0.2 ~ 3A
0 ~ 1A
RATED POWER
57.5W
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
CH1 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
6.0%
CH1 : 4.75 ~ 5.5V
2.0%
6.0%
6.0%
6.0%
100mVp-p
CH1 : 4.75 ~ 5.5V
2.0%
6.0%
6.0%
LINE REGULATION
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
LOAD REGULATION
1.0%
4.0%
1.0%
1.0%
4.0%
1.0%
1.0%
4.0%
1.0%
SETUP, RISE TIME
300ms, 50ms/230VAC
HOLD UP TIME (Typ.)
80ms/230VAC
VOLTAGE RANGE
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
72%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2A/115VAC
1A/230VAC
COLD START 20A/115VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
800ms, 50ms/115VAC at full load
10ms/115VAC at full load
120 ~ 370VDC
72%
72%
40A/230VAC
5V: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1012, UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
/ 70% RH
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
281.1K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
0.55Kg; 24pcs/14.1Kg/0.75CUFT
DIMENSION
PACKING
NOTE
62.5W
100mVp-p
VOLTAGE ADJ. RANGE
WORKING TEMP.
OTHERS
61W
RIPPLE & NOISE (max.) Note.2 100mVp-p
OVER VOLTAGE
(Note 4)
T-60C
CH1
PROTECTION
EMC
T-60B
OUTPUT NUMBER
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:T-60-SPEC 2010-10-18
T- 6 0
60W Triple Output Switching Power Supply
Mechanical Specification
Case No. 901
series
Unit:mm
3.5
7
152.5
1
3
84.5
8.2
4
5
2-M
6
97
65
9.5
2
3
7
3.5
4.5
78
24
159
150
6.5
22
Assignment
AC/L
AC/N
FG
DC OUTPUT -V
Pin No.
1
2
3
4
38
M3
3.5
28.5
9
3.5
3-
18
18.5
9
Terminal Pin No. Assignment
Assignment
Pin No.
DC OUTPUT +V2
5
DC OUTPUT COM
6
DC OUTPUT +V1
7
117
RECTIFIERS
&
FILTER
Block Diagram
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
FG
O.L.P.
fosc : 50KHz
-V
REGULATOR
RECTIFIERS
&
FILTER
+V2
RECTIFIERS
&
FILTER
+V1
COM
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
Derating Curve
Static Characteristics (B)
Ta=25
80
LOAD (%)
60
40
20
5.2
12
5.0
+12V
+5V
300
250
-12V
11
4.8
200
10
4.6
150
9
4.4
100
8
4.2
7
4.0
+12V
+5V
50
25
OUTPUT RIPPLE (mVp-p)
OUTPUT VOLTAGE (V)
100
13
-12V
-10
-10
0
0
10
20
30
40
50
45
AMBIENT TEMPERATURE ( )
60
55
(VERTICAL)
(HORIZONTAL)
60
80
100
120
140
160
180
200
220
240
260
INPUT VOLTAGE (V) 60Hz
File Name:T-60-SPEC 2010-10-18