MBL104S, MBL106S, MBL108S, MBL110S Datasheet

MBL104S, MBL106S, MBL108S, MBL110S
www.vishay.com
Vishay General Semiconductor
Miniature Glass Passivated Single-Phase
Surface Mount Bridge Rectifier
FEATURES
-
• UL recognition file number E54214
+
• Low profile - typical height of 1.4 mm
~
• Ideal for automated placement
• High surge current capability
~
• Meets MSL level 1, per
LF maximum peak of 260 °C
J-STD-020,
~
-
• Material categorization: For definitions of compliance
please see www.vishay.com/doc?99912
~
+
TYPICAL APPLICATIONS
Case Style (MBLS)
General purpose use in AC/DC bridge full wave rectification
for power supply, lighting ballaster, battery charger, home
appliances, office equipment, and telecommunication
applications.
PRIMARY CHARACTERISTICS
Package
MBLS
MECHANICAL DATA
IF(AV)
1.0 A
VRRM
400 V, 600 V, 800 V, 1000 V
IFSM
30 A
Epoxy meets UL 94 V-0 flammability rating
IR
5 μA
VF at IF = 0.4 A
0.95 V
Base P/N-M3 - halogen-free, RoHS-compliant, and
commercial grade
TJ max.
150 °C
Diode variations
Quad
Case: MBLS
Terminals: Matte tin plated leads, solderable
J-STD-002 and JESD22-B102
M3 suffix, meets JESD 201 class 1A whisker test
per
Polarity: As marked on body
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
MBL104S
MBL106S
MBL108S
MBL110S
UNIT
Maximum repetitive peak reverse voltage
VRRM
400
600
800
1000
V
Maximum RMS voltage
VRMS
280
420
560
700
V
Maximum DC blocking voltage
VDC
400
600
800
1000
V
Maximum average forward output rectified current
(fig. 1, fig. 2)
Peak forward surge current single sine-wave
superimposed on rated load
Rating for fusing (t < 8.3 ms)
Operating junction and storage temperature range
IF(AV) (1)
1.0
A
IFSM
30
A
I2t
3.0
A2 s
TJ, TSTG
- 55 to + 150
°C
Note
(1) Device mounted on 0.47" x 0.47" (12 mm x 12 mm) copper pad areas, 1 oz. PCB
Revision: 12-Sep-13
Document Number: 89959
1
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
MBL104S, MBL106S, MBL108S, MBL110S
www.vishay.com
Vishay General Semiconductor
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
TEST CONDITIONS
Maximum instantaneous
forward voltage drop per diode
IF = 0.4 A
Maximum DC reverse current
per diode
Rated VR
SYMBOL
MBL104S
MBL106S
VF (1)
TA = 25 °C
TA = 25 °C
MBL110S
UNIT
0.95
V
5
IR (2)
TA = 125 °C
MBL108S
μA
500
Notes
(1) Pulse test: 300 μs pulse width, 1 % duty cycle
(2) Pulse test: Pulse width ≤ 40 ms
THERMAL CHARACTERISTICS (TA = 25 °c unless otherwise noted)
PARAMETER
SYMBOL
Typical thermal resistance
(1)
MBL104S
MBL106S
MBL108S
RθJA
72
RθJL
25
MBL110S
UNIT
°C/W
Note
(1) Device mounted on 0.47" x 0.47" (12 mm x 12 mm) copper pad areas, 1 oz. PCB
ORDERING INFORMATION (Example)
PREFERRED P/N
UNIT WEIGHT (g)
PREFERRED PACKAGE CODE
BASE QUANTITY
DELIVERY MODE
0.136
I
4000
13" diameter plastic tape and reel
MBL106S-M3/I
1.1
Average Rectified Forward Current (A)
Average Rectified Forward Current (A)
RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted)
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Free air,
Mounted on 12 mm x 12 mm, 1 oz. PCB
0.1
0
0
25
50
75
100
125
150
Ambient Temperature (°C)
Fig. 1 - Derating Curve for Output Rectified Current
Revision: 12-Sep-13
1.2
RthJL = 25 °C/W
1
0.8
0.6
0.4
0.2
Free air,
Mounted on 12 mm x 12 mm, 1 oz. PCB
0
0
25
50
75
100
125
150
Lead Temperature (°C)
Fig. 2 - Maximum Non-Repetitive Peak Forward Surge
Current Per Diode
Document Number: 89959
2
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
MBL104S, MBL106S, MBL108S, MBL110S
www.vishay.com
Vishay General Semiconductor
Instantaneous Forward Current (A)
Forward Power Dissipation (W)
2
1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
0
100
TA = 150°C
10
TA = 100°C
1
TA = 80 °C
0.1
TA = 25 °C
0.01
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
20
Average Rectified Forward Current (A)
60
80
100
Instantaneous Forward Voltage (V)
Fig. 3 - Forward Power Dissipation
Fig. 5 - Typical Reverse Characteristics Per Diode
10
100
Junction Capacitance (pF)
Instantaneous Forward Current (A)
40
TA = 150 °C
TA = 100 °C
1
TA = 80 °C
TA = 25 °C
0.1
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
10
1
1.3
0.1
1
Instantaneous Forward Voltage (V)
10
100
Reverse Voltage (V)
Fig. 4 - Typical Instantaneous Forward Characteristics Per Diode
Fig. 6 - Typical Junction Capacitance Per Diode
PACKAGE OUTLINE DIMENSIONS in millimeters
1.5 max.
6.2 ± 0.2
4.6 ± 0.1
0.2
5.1 ± 0.1
+ 0.1
- 0.05
MBLS
0.45 ± 0.2
0.1
0
- 0.08
0.7 ± 0.1
0.6
Mounting Pad Layout
4
0.7 min.
1
1
4.8 max.
4
0.45 min.
2
3
4 ± 0.2
5.3 max.
Revision: 12-Sep-13
6.4 max.
3
2
4 ± 0.2
Document Number: 89959
3
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1