データシート

For more information, please visit the product page.
date
08/28/2012
page
1 of 6
SERIES: VSCP-2K4 │ DESCRIPTION: AC-DC POWER SUPPLY
RoHS
(Vdc)
VSCP-2K4-09
9
VSCP-2K4-12
12
VSCP-2K4-15
15
VSCP-2K4-18
18
VSCP-2K4-36
ripple
and noise3
efficiency
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
133 / 266
2,400
90
83
100 / 200
2,400
120
84
80 / 160
2,400
150
85
66 / 133.3
2,400
150
85
24
50 / 100
2,400
150
88
36
33 / 66.6
2,400
150
88
48
25 / 50
2,400
150
89
20 / 40
2,400
150
90
O
VSCP-2K4-48
60
1. output voltage is measured at output power connector
2. maximum current is measured at 100~120 V input / 200~240 V input
3. ripple and noise is measured from 10 kHz to 20 MHz at output terminals with 0.1 μF ceramic capacitor and a 22 μF electrolytic capacitor in parallel
IS
C
Notes:
output
power
N
VSCP-2K4-24
VSCP-2K4-60
output
current2
TI
output
voltage1
MODEL
U
up to 2,400 W continuous power
universal input (90~260 Vac / 130~370 Vdc)
single output from 9~60 V
programmable output voltage
active power correction (98%)
current sharing capable
power good, remote sense, remote on/off control
built-in DC fan
over load, over voltage, over temperature, and short circuit protections
UL and TUV safety approvals
efficiency up to 90%
N
•
•
•
•
•
•
•
•
•
•
•
ED
FEATURES
PART NUMBER KEY
VSCP-2K4 - XX
Base Number
D
Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSCP-2K4 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 2 of 6
INPUT
conditions/description
min
voltage
frequency
current
max
units
90
130
260
370
Vac
Vdc
47
63
Hz
at 230 Vac
inrush current
power factor correction
at 230 Vac, full load
conditions/description
min
0 ~ 50°C
230 Vac at full load
A
typ
max
units
±1
%
±1
%
±0.04
%/°C
12
ms
-8
+3
%
25
100
%
N
temperature coefficient
A
180
U
line regulation
load regulation
hold-up time
13.5
0.98
OUTPUT
parameter
typ
ED
parameter
adjustable with built-in trim pot
programming
output voltage programmable through external
1 ~ 5 V control voltage on VCI. Control voltage
can also be obtained from VCO via a 470 KΩ pot.
see application diagrams
remote sense
Designated as (VS+) and (VS-). Total voltage compensation from cable losses with respect to the main
output.
remote inhibit
Designated as (INH), requires a low signal to inhibit the output.
current sharing
Designated as (PAR), use in parallel for forced current sharing function.
TI
adjustability
N
PROTECTION
parameter
conditions/description
over voltage protection
Notes:
current limiting 3 times with auto recovery before
shutdown
max
units
110
typ
135
%
115
130
%
O
over current protection1
min
1. Protection mode sends a pulse, waits 1.5 seconds, sends second pulse, waits 3 seconds, sends third pulse, waits 5 seconds. If overload is still present, the unit will
shutdown.
IS
C
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
safety approvals
TUV EN 60950, UL/cUL 1950
EMI/EMC
EN 55022, EN 61000-4-(2,3,4,5,6,8,11), EN 61000-3-(2,3), ENV50204
leakage current
at 240 Vac
RoHS compliant
yes
max
units
10.5
mA
ENVIRONMENTAL
conditions/description
operating temperature
see derating curves
max
units
0
65
°C
storage temperature
-20
85
°C
operating humidity
20
90
%
storage humidity
10
95
%
2
G
D
parameter
vibration
min
10~200Hz, 10min/cycle, 60 min for each axis
cui.com
typ
For more information, please visit the product page.
CUI Inc │ SERIES: VSCP-2K4 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 3 of 6
MECHANICAL
parameter
conditions/description
min
typ
weight
max
8.9
332 x 212 x 123.9 (13.071 x 8.346 x 4.878 mm)
MECHANICAL DRAWING
332.00 13.071
5XM4X0.7 TERMINAL
BLOCK FOR AC INPUT
8-M3X0.5 TERMINAL BLOCK
FOR CONTROL SIGNAL
N
6-M6 SCREW
FOR DC OUTPUT
O
320.00 12.598
IS
C
4-M4X0.7 MOUNTING
HOLE FOR USER
TI
N
212.00 8.346
6.00 0.236
inch
U
units: mm[inch]
tolerance: ±1.0mm unless otherwise specified
123.90 4.878
Kg
ED
dimensions
units
30.00 1.181
LOGIC CONNECTOR
180.00 7.087
INH
2
GND
return, output ground
3
PAR
current sharing, parallel function
4
PG
power good signal
5
VCO
reference output voltage (5.1 Vdc) to be used
for output programming
6
VCI
command input voltage for output programming
cui.com
remote on/off, remote inhibit
7
VS(-)
remote sense (-)
8
VS(+)
remote sense (+)
24.00 0.945
D
290.00 11.417
1
For more information, please visit the product page.
CUI Inc │ SERIES: VSCP-2K4 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 4 of 6
Load (%)
≈
100
ED
DERATING CURVES
80
60
50
40
≈
U
20
-25
0
10
20
30
40
50
60
70
N
Ambient Temperature (°C)
O
VSCP-2K4
VSCP-2K4
IS
C
D
Optional
N
Standard
TI
WIRING CONFIGURATIONS
Optional
Optional
VSCP-2K4
VSCP-2K4
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSCP-2K4 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 5 of 6
D
IS
C
O
N
TI
N
U
ED
LOGIC CONNECTIONS
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSCP-2K4 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 6 of 6
REVISION HISTORY
rev.
description
date
08/20/2007
initial release
applied new spec template
1.02
applied new spec template, corrected over current protection
09/26/2011
1.03
spec updated
02/13/2012
1.04
V-Infinity branding removed
ED
1.0
1.01
08/07/2008
08/28/2012
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.