MEANWELL SCP-2K4-24

SCP-2K4
2400W Parallel (N+1) With PFC Function
series
■ Features :
AC input 180~260VAC, 3ψ3 wire
AC 220V, 1ψor 380V, 3ψ4 wire(option)
PF> 0.98@ 230VAC
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in remote sense function, remote ON-OFF control
Built-in power good signal output
Built-in parallel operation function(N+1)
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
Case coating with paint
3 years warranty
..
SPECIFICATION
ORDER NO.
OUTPUT
SCP-2K4-09
SCP-2K4-12
SCP-2K4-15
SCP-2K4-18
SCP-2K4-24
SCP-2K4-36
SCP-2K4-48
SCP-2K4-60
SAFETY MODEL NO.
2K4S-P009
2K4S-P012
2K4S-P015
2K4S-P018
2K4S-P024
2K4S-P036
2K4S-P048
2K4S-P060
DC VOLTAGE
9V
12V
15V
18V
24V
36V
48V
60V
RATED CURRENT
266A
200A
160A
133.3A
100A
66.6A
50A
40A
CURRENT RANGE
0 ~ 266A
0 ~ 200A
0 ~ 160A
0 ~ 133.3A
0 ~ 100A
0 ~ 66.6A
0 ~ 50A
0 ~ 40A
RATED POWER
2394W
2400W
2400W
2399W
2400W
2397W
2400W
2400W
120mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
200mVp-p
200mVp-p
RIPPLE & NOISE (max.) Note.2 90mVp-p
VOLTAGE ADJ. RANGE
± 3.0% Typical adjustment by potentiometer
± 1.0%
± 1.0%
VOLTAGE TOLERANCE Note.3 ± 2.0%
20% ~ 100% adjustment by 1 ~ 5VDC external control
± 1.0%
± 1.0%
± 1.0%
± 1.0%
± 1.0%
LINE REGULATION
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
LOAD REGULATION
± 1.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
88%
88%
89%
89%
SETUP, RISE, HOLD UP TIME 800ms, 400ms, 12ms at full load
INPUT
VOLTAGE RANGE
180 ~ 260VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
>0.98 / 230VAC
3ψ3 wire (other system available)
EFFICIENCY (Typ.)
83%
AC CURRENT
INRUSH CURRENT (max.)
15A / 230VAC
60A / 230VAC
LEAKAGE CURRENT(max.)
3.5mA / 240VAC
110 ~ 140% rated output power
OVERLOAD
Note. 4
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
84%
85%
86%
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
110 ~ 135% Follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
>100℃ / measure by heat sink, near transformer
WORKING TEMP.
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +65℃ (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
-20 ~ +85℃, 10 ~ 95% RH
± 0.04% / ℃ (0 ~ 50℃)
10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, OP/FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) class A
EMC
(Note. 5)
Compliance to EN61000-3-2,3
HARMONIC CURRENT
EMS IMMUNITY
POWER GOOD SIGNAL
SPECIAL FUNCTION
OTHERS
COOLING
Open collector of NPN transistor
DC Voltage Adj., Remote sensing, remote control, parallel operation(refer to control terminal instruction manual)
By fan, >20% load or >50℃ fan on
MTBF
24.9K hrs min. MIL-HDBK-217F(25℃)
DIMENSION
350*212*124mm (L*W*H)
9.0kg ; 1pcs / 10kg / CARTON
PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria A
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery before shut down
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCP-2K4-SPEC 2007-03-01
SCP-2K4
2400W Parallel (N+1) With PFC Function
Mechanical Specification
series
212[8.35]
Unit:mm
332 [13.07]
1 2 3 4 5 6 7 8
123.9 [4.88]
5-M4X0.7 Terminal block
For AC Input
8-M3X0.5 Terminal Block
For Control Signal
V-ADJ
1
2
3 4
5
6-M6 SCREW
FOR DC OUTPUT
Air flow
direction
POS(+)
LED
320 [12.60]
30 [1.18]
180[7.09]
6 [0.24] TYP
NEG(-)
4-M4X0.7 MOUNTING
HOLE FOR USER
24 [0.94]
290 [11.42]
Control Terminal Pin. No. Assignment :
Pin No.
1
2
Pin No.
5
6
Assignment
VS+
VSVCI
VCO
3
4
7
8
AC Input Terminal Pin. No. Assignment
Pin No.
1
2
3
Assignment
PG
PAR
GND
INH
Assignment
FG
N
T
Pin No.
4
5
Assignment
S
R
Derating Curve
Ta=25℃
OUTPUT POWER (W)
100
LOAD (%)
80
60
40
20
-20
2400
2000
1200
900
-10
10
20
30
40
50
AMBIENT TEMPERATURE (℃)
60
70
90
110
150
170
260
INPUT VOLTAGE (VAC) 60Hz
File Name:SCP-2K4-SPEC 2007-03-01
SCP-2K4
2400W Parallel (N+1) With PFC Function
series
Control terminal instruction manual
LOAD
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
USING INTERNAL VOLTAGE CONTROL
LOAD
LOAD
LOAD
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
ON/OFF SWITCH
ON/OFF CONTROL BY TRANSISTOR
ON/OFF CONTROL BY SWITCH
REMOTE SENSING
H:ON
L:OFF
Vout
GOOD
FAIL
O.V.P. 120% (Typ.)
: LED OFF
: LED ON
120
100
VS+
VSVCI
VCO
PG
PAR
GND
INH
40V / 0.5A MAX.
POWER GOOD SIGNAL
VS+
VSVCI
VCO
PG
PAR
GND
INH
OUTPUT VOLTAGE (%)
LOAD
LOAD
DC 1-5V
80
Non-Linear
60
40
20
1
OUTPUT VOLTAGE ADJUST WITH DC 1-5V
2
3
4
5
6
EXTERNAL VOLTAGE (DC)
LOAD
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
PARALLEL OPERATION WITH REMOTE SENSING
V
LOAD
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
VS+
VSVCI
VCO
PG
PAR
GND
INH
PARALLEL OPERATION WITHOUT REMOTE SENSING
File Name:SCP-2K4-SPEC 2007-03-01
SCP-2K4
2400W Parallel (N+1) With PFC Function
FIG. A: 3
series
3W 220VAC SYSTEM (STANDARD MODEL FOR STOCK)
R
R
L1
N1
220V
S
L2
N2
T
L3
N3
S
FG1
FG2
FG3
220V
N (NC)
FG
T
FIG. B: 1
220VAC SYSTEM
L
R
L1
N1
220V
S
L2
N2
T
L3
N3
N
FG1
FG2
FG3
N
FG
FIG. C: 3
4W 220/380VAC SYSTEM
R
R
L1
N1
220V
S
L2
N2
T
N
L3
N3
FG1
FG2
FG3
N
S
380V
FG
T
4W 190/110VAC SYSTEM
R
110V
R
L1
N1
S
L2
N2
N
(N.C.)
T
L3
N3
S
FG1
FG2
FG3
N (NC)
190V
FIG. D: 3
FG
T
File Name: SCP-2K4-SPEC 2007-03-01