SCP-2K4 2400W Parallel (N+1) With PFC Function series ■ Features : AC input 180~260VAC, 3ψ3 wire AC 220V, 1ψor 380V, 3ψ4 wire(option) PF> 0.98@ 230VAC Protections: Short circuit / Overload / Over voltage / Over temperature Built-in remote sense function, remote ON-OFF control Built-in power good signal output Built-in parallel operation function(N+1) Can adjust from 20~100% output voltage by external control 1-5V Forced air cooling by built-in DC fan Case coating with paint 3 years warranty .. SPECIFICATION ORDER NO. OUTPUT SCP-2K4-09 SCP-2K4-12 SCP-2K4-15 SCP-2K4-18 SCP-2K4-24 SCP-2K4-36 SCP-2K4-48 SCP-2K4-60 SAFETY MODEL NO. 2K4S-P009 2K4S-P012 2K4S-P015 2K4S-P018 2K4S-P024 2K4S-P036 2K4S-P048 2K4S-P060 DC VOLTAGE 9V 12V 15V 18V 24V 36V 48V 60V RATED CURRENT 266A 200A 160A 133.3A 100A 66.6A 50A 40A CURRENT RANGE 0 ~ 266A 0 ~ 200A 0 ~ 160A 0 ~ 133.3A 0 ~ 100A 0 ~ 66.6A 0 ~ 50A 0 ~ 40A RATED POWER 2394W 2400W 2400W 2399W 2400W 2397W 2400W 2400W 120mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p RIPPLE & NOISE (max.) Note.2 90mVp-p VOLTAGE ADJ. RANGE ± 3.0% Typical adjustment by potentiometer ± 1.0% ± 1.0% VOLTAGE TOLERANCE Note.3 ± 2.0% 20% ~ 100% adjustment by 1 ~ 5VDC external control ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% LINE REGULATION ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% LOAD REGULATION ± 1.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% 88% 88% 89% 89% SETUP, RISE, HOLD UP TIME 800ms, 400ms, 12ms at full load INPUT VOLTAGE RANGE 180 ~ 260VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR >0.98 / 230VAC 3ψ3 wire (other system available) EFFICIENCY (Typ.) 83% AC CURRENT INRUSH CURRENT (max.) 15A / 230VAC 60A / 230VAC LEAKAGE CURRENT(max.) 3.5mA / 240VAC 110 ~ 140% rated output power OVERLOAD Note. 4 PROTECTION OVER VOLTAGE OVER TEMPERATURE 84% 85% 86% Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover 110 ~ 135% Follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100℃ / measure by heat sink, near transformer WORKING TEMP. Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +65℃ (Refer to output load derating curve) WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE -20 ~ +85℃, 10 ~ 95% RH ± 0.04% / ℃ (0 ~ 50℃) 10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, OP/FG:100M Ohms / 500VDC / 25℃/ 70% RH EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) class A EMC (Note. 5) Compliance to EN61000-3-2,3 HARMONIC CURRENT EMS IMMUNITY POWER GOOD SIGNAL SPECIAL FUNCTION OTHERS COOLING Open collector of NPN transistor DC Voltage Adj., Remote sensing, remote control, parallel operation(refer to control terminal instruction manual) By fan, >20% load or >50℃ fan on MTBF 24.9K hrs min. MIL-HDBK-217F(25℃) DIMENSION 350*212*124mm (L*W*H) 9.0kg ; 1pcs / 10kg / CARTON PACKING NOTE Compliance to EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria A 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery before shut down 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:SCP-2K4-SPEC 2007-03-01 SCP-2K4 2400W Parallel (N+1) With PFC Function Mechanical Specification series 212[8.35] Unit:mm 332 [13.07] 1 2 3 4 5 6 7 8 123.9 [4.88] 5-M4X0.7 Terminal block For AC Input 8-M3X0.5 Terminal Block For Control Signal V-ADJ 1 2 3 4 5 6-M6 SCREW FOR DC OUTPUT Air flow direction POS(+) LED 320 [12.60] 30 [1.18] 180[7.09] 6 [0.24] TYP NEG(-) 4-M4X0.7 MOUNTING HOLE FOR USER 24 [0.94] 290 [11.42] Control Terminal Pin. No. Assignment : Pin No. 1 2 Pin No. 5 6 Assignment VS+ VSVCI VCO 3 4 7 8 AC Input Terminal Pin. No. Assignment Pin No. 1 2 3 Assignment PG PAR GND INH Assignment FG N T Pin No. 4 5 Assignment S R Derating Curve Ta=25℃ OUTPUT POWER (W) 100 LOAD (%) 80 60 40 20 -20 2400 2000 1200 900 -10 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 90 110 150 170 260 INPUT VOLTAGE (VAC) 60Hz File Name:SCP-2K4-SPEC 2007-03-01 SCP-2K4 2400W Parallel (N+1) With PFC Function series Control terminal instruction manual LOAD VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH USING INTERNAL VOLTAGE CONTROL LOAD LOAD LOAD VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH ON/OFF SWITCH ON/OFF CONTROL BY TRANSISTOR ON/OFF CONTROL BY SWITCH REMOTE SENSING H:ON L:OFF Vout GOOD FAIL O.V.P. 120% (Typ.) : LED OFF : LED ON 120 100 VS+ VSVCI VCO PG PAR GND INH 40V / 0.5A MAX. POWER GOOD SIGNAL VS+ VSVCI VCO PG PAR GND INH OUTPUT VOLTAGE (%) LOAD LOAD DC 1-5V 80 Non-Linear 60 40 20 1 OUTPUT VOLTAGE ADJUST WITH DC 1-5V 2 3 4 5 6 EXTERNAL VOLTAGE (DC) LOAD VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH PARALLEL OPERATION WITH REMOTE SENSING V LOAD VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH PARALLEL OPERATION WITHOUT REMOTE SENSING File Name:SCP-2K4-SPEC 2007-03-01 SCP-2K4 2400W Parallel (N+1) With PFC Function FIG. A: 3 series 3W 220VAC SYSTEM (STANDARD MODEL FOR STOCK) R R L1 N1 220V S L2 N2 T L3 N3 S FG1 FG2 FG3 220V N (NC) FG T FIG. B: 1 220VAC SYSTEM L R L1 N1 220V S L2 N2 T L3 N3 N FG1 FG2 FG3 N FG FIG. C: 3 4W 220/380VAC SYSTEM R R L1 N1 220V S L2 N2 T N L3 N3 FG1 FG2 FG3 N S 380V FG T 4W 190/110VAC SYSTEM R 110V R L1 N1 S L2 N2 N (N.C.) T L3 N3 S FG1 FG2 FG3 N (NC) 190V FIG. D: 3 FG T File Name: SCP-2K4-SPEC 2007-03-01