350/500 Heavy Wall™ IR Entrances - Architectural Detail Manual

JUNE, 2012
FEATURES
Hurricane Resistant Product
Blast Mitigation Product
Features
• 350 medium stile has 3-1/2" vertical stile, 3-1/2" top and 6-1/2" bottom rail
• 500 wide stile has 5" vertical stile, 5" top and 6-1/2" bottom rail
• Door is 2" deep
• Door has 3/16" wall thickness
• Welded corner construction
• Single acting
• Offset pivot, butt hinges or continuous geared hinge
• Surface mounted or concealed closers
• MS lock or exit device hardware
• Architects Classic push-pulls
• Square stops with interior silicone seal for 9/16" (14.3 mm) or 1" (25.4 mm) glazing infills
• Adjustable astragal utilizing pile weathering with polymeric fin at meeting stiles
• Polymeric bulb weatherstripping in door frames
• Permanodic® anodized finishes in seven standard choices
• Painted finishes in standard and custom choices
Optional Features
• Numerous push/pull options
• Paneline® exit device or Paneline® EL exit device
• 3/16" heavy wall frame
• Crossrails and 10" Bottom Rail
• Square stops with 3MTM VHBTM interior tape for 9/16" (14.3 mm) or 1" (25.4 mm) glazing infills
Product Applications
• 350/500 Heavy WallTM IR provides added strength for schools, institutions, office buildings
and other high traffic applications where codes require windborne debris or blast
mitigating protection.
© Kawneer Company, Inc., 2012
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-44
350/500 HEAVY WALLTM IR ENTRANCES
For specific product applications,
Consult your Kawneer representative.
kawneer.com
1
kawneer.com
© Kawneer Company, Inc., 2012
BLANK PAGE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
350/500 HEAVY WALLTM IR ENTRANCES
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
JUNE, 2012
EC 97911-44
JUNE, 2012
350/500 HEAVY WALLTM IR ENTRANCES
INDEX
PICTORIAL VIEW................................................................................. 5
HURRICANE RESISTANT
350 DOOR WITH TRIFAB® VG 450 FRAMING DETAILS............. 6,7
350 DOOR WITH TRIFAB® VG 451 FRAMING DETAILS............. 8,9
350 DOOR WITH IR500/501 FRAMING DETAILS................... 10,11
500 DOOR ENTRANCE DETAILS............................................ 12,13
PANELINE® / PANELINE® EL EXIT DEVICES............................... 14
CROSS RAIL / BOTTOM RAIL OPTIONS.................................... 15
ENTRANCE HARDWARE OFFERINGS.................................. 16,17
BLAST MITIGATION
350 DOOR ENTRANCE DETAILS................................................. 18
ENTRANCE HARDWARE OFFERINGS....................................... 19
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED
ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT
CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR
GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference.
Numbers in parentheses (
) are millimeters unless otherwise noted.
The following metric (SI) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
© Kawneer Company, Inc., 2012
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-44
3
Kawneer reserves the right to change configurations without prior notice when deemed necessary
for product improvement.
kawneer.com
kawneer.com
© Kawneer Company, Inc., 2012
BLANK PAGE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
350/500 HEAVY WALLTM IR ENTRANCES
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
JUNE, 2012
EC 97911-44
JUNE, 2012
350/500 HEAVY WALLTM IR ENTRANCES
PICTORIAL VIEW
#1 MECHANICAL FASTENING is accomplished
by attaching a 5/16" (7.9) thick extruded aluminum
channel clip to the vertical stile with 1/4"-20 heat
strengthened bolts and 3/16" thick steel nut plates
for a high strength welding base for attachment
horizontal member.
#2 SIGMA* DEEP PENETRATION PLUG WELDS
are made top and bottom after the horizontal
is properly positioned over the channel clip to
help provide the strongest door corner joint
currently available.
© Kawneer Company, Inc., 2012
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-44
WELDED CORNER CONSTRUCTION
* An arc welding process known as Shielded Inert Gas Metal Arc (SIGMA)
or also known as Metal Inert Gas (MIG).
kawneer.com
#3 SIGMA* FILLET WELDS along both top and
bottom webs of the rail extrusion complete the
welded corner construction.
5
TM
350 HEAVY WALL IR DETAILS
Hurricane Resistant Product
4
4A
1
1A
1
HINGE JAMB
9/16" INFILL
TAPE GLAZED
4
4A
2
1
1A
5
1" INFILL
WET GLAZED
3
5
450-547
450-547
2
MEETING STILES
450-547
1A
CONTINUOUS HINGE
JAMB
1" INFILL
TAPE GLAZED
kawneer.com
© Kawneer Company, Inc., 2012
350/500 HEAVY WALLTM IR ENTRANCES
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SCALE 3" = 1'-0"
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
6
JUNE, 2012
EC 97911-44
(Doors shown with 9/16" infill, wet glazed)
350 HEAVY WALLTM IR DOORS
WITH TRIFAB® VG 450 CENTER DOOR FRAMING
3
LOCK JAMB
350/500 HEAVY WALLTM IR ENTRANCES
JUNE, 2012
EC 97911-44
350 HEAVY WALLTM IR DETAILS
Hurricane Resistant Product
SCALE 3" = 1'-0"
350 HEAVY WALLTM IR DOORS
WITH TRIFAB® VG 450 CENTER DOOR FRAMING
(Doors shown with 9/16" infill, wet glazed)
450-545
COC WITH SINGLE ACTING OFFSET ARM
450-079
041-045
4
DOOR HEADER/
TRANSOM BAR
4A
DOOR HEADER/
TRANSOM BAR
BOTTOM RAIL
WEATHERING
069-129
© Kawneer Company, Inc., 2012
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE ACTING DOORS
DOOR STOP USED
WITH PAIRS OF DOORS
5*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
kawneer.com
BOTTOM RAIL
WEATHERING
069-129
DOOR STOP USED
WITH PAIRS OF DOORS
5*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
7
350/500 HEAVY WALLTM IR ENTRANCES
8
JUNE, 2012
350 HEAVY WALL IR DETAILS
Hurricane Resistant Product
EC 97911-44
TM
SCALE 3" = 1'-0"
350 HEAVY WALLTM IR DOORS
WITH TRIFAB® VG 451 CENTER DOOR FRAMING
(Doors shown with 9/16" infill, wet glazed)
2
3
1
1A
7
6
6A
1
1A
7
4
4
6
6A
2
3
1
1A
7
7
451-547
451-547
1
HINGE JAMB
2
MEETING STILES
3
LOCK JAMB
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
1A
6
6A
451-547
451-026
1A
CONTINUOUS HINGE
JAMB
9/16" INFILL
TAPE GLAZED
4
TRANSOM
INSERT
1" INFILL
WET GLAZED
1" INFILL
TAPE GLAZED
kawneer.com
© Kawneer Company, Inc., 2012
6
6A
5
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
5
350/500 HEAVY WALLTM IR ENTRANCES
JUNE, 2012
EC 97911-44
350 HEAVY WALLTM IR DETAILS
Hurricane Resistant Product
SCALE 3" = 1'-0"
350 HEAVY WALLTM IR DOORS
WITH TRIFAB® VG 451 CENTER DOOR FRAMING
(Doors shown with 9/16" infill, wet glazed)
5
TRANSOM HEAD
COC WITH SINGLE ACTING OFFSET ARM
5
TRANSOM HEAD
450-022
STOPS
450-022
STOPS
451-079
451-545
041-045
6
DOOR HEADER/
TRANSOM BAR
© Kawneer Company, Inc., 2012
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE ACTING DOORS
6A
DOOR HEADER/
TRANSOM BAR
BOTTOM RAIL
WEATHERING
069-129
DOOR STOP USED
WITH PAIRS OF DOORS
7*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
kawneer.com
BOTTOM RAIL
WEATHERING
069-129
DOOR STOP USED
WITH PAIRS OF DOORS
7*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
9
350/500 HEAVY WALLTM IR ENTRANCES
10
JUNE, 2012
350 HEAVY WALL IR DETAILS
Hurricane Resistant Product
EC 97911-44
TM
SCALE 3" = 1'-0"
350 HEAVY WALLTM IR DOORS
WITH IR500/501 DOOR FRAMING
(Doors shown with 9/16" infill, wet glazed)
6
6A
2
3
1
1A
7
1
1A
7
4
4A
4
4A
6
6A
2
3
1
1A
7
7
575-051
575-051
069-177
575-052
575-052
069-177
1
HINGE JAMB
2
MEETING STILES
3
LOCK JAMB
575-051 (Mod.)
575-051
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
1A
6
6A
575-051 (Mod.)
575-033
1A
CONTINUOUS HINGE
JAMB
9/16" INFILL
TAPE GLAZED
4
9/16" INFILL
TRANSOM INSERT
(IR500)
1" INFILL
WET GLAZED
575-052
575-052
575-052
069-177
575-133
4A
1" INFILL
TRANSOM INSERT
(IR501)
1" INFILL
TAPE GLAZED
kawneer.com
© Kawneer Company, Inc., 2012
6
6A
5
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
5
350/500 HEAVY WALLTM IR ENTRANCES
JUNE, 2012
EC 97911-44
350 HEAVY WALLTM IR DETAILS
Hurricane Resistant Product
SCALE 3" = 1'-0"
350 HEAVY WALLTM IR DOORS
WITH IR500/501 DOOR FRAMING
(Doors shown with 9/16" infill, wet glazed)
IR501 FRAMING
COC WITH SINGLE ACTING OFFSET ARM
2-1/2"
(63.5)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
IR500 FRAMING
COC WITH SINGLE ACTING OFFSET ARM
575-112
575-012
5"
(69.85)
5
TRANSOM HEAD
5
TRANSOM HEAD
575-060
575-061
575-160
575-161
575-162
575-162
6
DOOR HEADER/
TRANSOM BAR
© Kawneer Company, Inc., 2012
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
041-045
041-045
6A
DOOR HEADER/
TRANSOM BAR
BOTTOM RAIL
WEATHERING
069-129
DOOR STOP USED
WITH PAIRS OF DOORS
7*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
kawneer.com
BOTTOM RAIL
WEATHERING
069-129
DOOR STOP USED
WITH PAIRS OF DOORS
7*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
11
350/500 HEAVY WALLTM IR ENTRANCES
JUNE, 2012
500 HEAVY WALL IR DETAILS
Hurricane Resistant Product
EC 97911-44
TM
SCALE 3" = 1'-0"
500 HEAVY WALLTM IR DOORS
WITH TRIFAB® VG 450 CENTER DOOR FRAMING
(TRIFAB® VG 451 CENTER DOOR FRAME AND IR500/501 DOOR FRAME OPTIONAL)
2
1
1A
5
3
5
450-547
1
HINGE JAMB
2
MEETING STILES
450-547
450-547
3
LOCK JAMB
1A
CONTINUOUS HINGE
JAMB
9/16" INFILL
TAPE GLAZED
1" INFILL
WET GLAZED
1" INFILL
TAPE GLAZED
kawneer.com
© Kawneer Company, Inc., 2012
1
1A
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
4
4A
4
4A
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
12
350/500 HEAVY WALLTM IR ENTRANCES
JUNE, 2012
EC 97911-44
500 HEAVY WALLTM IR DETAILS
Hurricane Resistant Product
SCALE 3" = 1'-0"
500 HEAVY WALLTM IR DOORS
WITH TRIFAB® VG 450 CENTER DOOR FRAMING
(TRIFAB® VG 451 CENTER DOOR FRAME AND IR500/501 DOOR FRAME OPTIONAL)
450-545
COC WITH SINGLE ACTING OFFSET ARM
450-079
041-045
4
DOOR HEADER/
TRANSOM BAR
4A
DOOR HEADER/
TRANSOM BAR
BOTTOM RAIL
WEATHERING
© Kawneer Company, Inc., 2012
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE ACTING DOORS
069-129
DOOR STOP USED
WITH PAIRS OF DOORS
5*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
kawneer.com
BOTTOM RAIL
WEATHERING
069-129
DOOR STOP USED
WITH PAIRS OF DOORS
5*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
13
350/500 HEAVY WALLTM IR ENTRANCES
14
JUNE, 2012
PANELINE / PANELINE EL EXIT DEVICE
Hurricane Resistant Product
®
SCALE 3" = 1'-0"
EC 97911-44
®
PANELINE® EXIT DEVICE
The Paneline® concealed rod exit device will accommodate variations in door width as shown in the following
illustrations. Sidelites adjacent to Paneline equipped doors not requiring exit devices may be fitted with fixed panels
as detailed below to match the general appearance of the Paneline cross rail.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
The Optional Paneline® EL device is designed for electrified access control and is compatible with most key pad
and card reader systems.
See Hardware Section for complete description of Paneline hardware, including finish of units.
Paneline® uses mortise cylinder in lieu of the normal rim-type.
Dummy Paneline units should not use any type of lock.
1-1/8"
(27.8)
1"
(25.4)
INTERIOR ELEVATION
INTERIOR VIEW
CROSS RAIL
WITH EXIT DEVICE
AND CPN PULL HANDLE
LOCK STILE TRIM FILLER WIDTH
VARIES WITH STILE WIDTH
3'-01/8"
(917.8)
TO BOTTOM
OF DOOR
PANELINE® EL COMPONENTS
DOGGING LOCK
(TYPICAL)
PUSH
5 7/8"
(149.2)
1'-11 5/16" (592.1)
ACTIVE PUSH PANEL
FIXED WIDTH
DOOR OPENING WIDTH
PIVOT STILE TRIM FILLER WIDTH
VARIES WITH DOOR WIDTH
POWER TRANSFER
INTERMEDIATE BUTT HINGE
POWER TRANSFER
INTERMEDIATE OFFSET PIVOT
4'-0" (1219.2) MAX. - 2'-10 13/32" (873.9) MIN.
3'-0" (914.6) ADA MIN.
EXTERIOR VIEW
"CPN" PULL AND OPTIONAL
CYLINDER GUARD SHOWN
ELECTRIC POWER TRANSFER
(EPT)
SP 1000 POWER SUPPLY
kawneer.com
© Kawneer Company, Inc., 2012
1
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
7-1/8"
(181.0)
PUSH
8-7/16"
(214.3)
2"
(50.8)
© Kawneer Company, Inc., 2012
10"
(254)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3-1/2" CROSS RAIL
WITH 9/16" INFILL
kawneer.com
8-7/16"
(214.3)
6"
(152.4)
3-1/2"
(88.9)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JUNE, 2012
350/500 HEAVY WALLTM IR ENTRANCES
EC 97911-44
SCALE 3" = 1'-0"
CROSS RAIL / BOTTOM RAIL OPTIONS
Hurricane Resistant Product
6" CROSS RAIL
WITH 9/16" INFILL
10" BOTTOM RAIL
8-1/4" CROSS RAIL
WITH 9/16" INFILL
200-183
200-184
200-185
15
350/500 HEAVY WALLTM IR ENTRANCES
JUNE, 2012
ENTRANCE HARDWARE OFFERINGS
Hurricane Resistant Product
EC 97911-44
Door Sizes
OPTIONAL
Maximum Size:
4'-0" x 8'-0" (1219.2 x 2438.4) per leaf
8'-0" x 8'-0" (2438.4 x 2438.4) pairs
3'-0" x 9'-0" (914.4 x 2743.2) per leaf
6'-0" x 9'-0" (1828.8 x 2743.2) pairs
Sizes up to maximum per leaf or pair
Glass Stops
Square stops for 9/16" (14.3) infill, interior screw applied
glass stop with silicone seal
Square stops for 9/16" (14.3) or 1" (25.4) infill, interior screw
applied glass stop with 3M VHB structural tape.
Door Frames
IR500 frame = 2-1/2" x 5" (63.5 x 127)
- *IR 501 frame = 2-1/2" x 5" (63.5 x 127)
- Trifab® VG 450 non-transom or sidelites
- Trifab® VG 451 (50.8 x 114.3)
- 1600 sub-frame with door jamb adaptors
   and sub-head
Architects Classic Hardware:
     - CO-9 Pull and CP-II Push Bar
     - CO-9 Pull with Exit Devices
     - CO-9 Pull with Paneline® Exit Device
Supplied by others
Norton 1601 Adjustable or 1601 BF
Adjustable Surface Closer with back-check, with or without
adjustable hold open
Surface Closers:
- Norton 8100 BF
- LCN 4040, LCN 1260 adjustable
- Dor-O-Matic/Falcon SC 60
Push-Pulls
Door Closers
**Concealed Closers
- Standard COC with single acting offset arm
- LCN 2030, LCN 5030
Kawneer Top, Bottom and Intermediate offset pivots
Locking
MS 1850 Deadbolt 3-Point Lock with 4016 Top Bolt and
4056 Bottom Bolt
Exit Device
Hardware
Kawneer 1686 Concealed Exit Device
Threshold
Kawneer Threshold
1/2" x 4-3/8" (12.7 x 111.1)
Weathering
Sealair® bulb polymeric weathering in door frames, adjustable bottom rail sweep with EPDM blade and adjustable
astragal utilizing pile weathering with polymeric fin at
meeting stiles
- Kawneer 4-1/2" x 4" (114.3 x 101.6) Top,
  Bottom and Intermediate (NRP) Butt Hinge
- Continuous Geared Hinge
- Kawneer Paneline® Conc. Rod Exit Device
- Kawneer Paneline® EL Conc. Rod Exit Device
- Falcon HSEC1690 Conc. Rod Exit Device
- Jackson 2086 Conc. Rod Exit Device
- Jackson 2086 EL Conc. Rod Exit Device
- Von Duprin HSEC9947 Conc. Rod Exit Device
- Von Duprin XP 98/99 Rim Exit Device
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Hinging
NOTE:
*IR 501 door frame uses IR 500 door jamb with IR 501 filler, (assembly has not been impact tested).
**Concealed Overhead Closer requires Trifab® VG 450 frame, Trifab® VG 450 sub-header, or 1600 Wall System®1 sub-frame.
kawneer.com
© Kawneer Company, Inc., 2012
STANDARD
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
16
JUNE, 2012
350/500 HEAVY WALLTM IR ENTRANCES
EC 97911-44
ENTRANCE HARDWARE OFFERINGS
Hurricane Resistant Product
MAXIMUM
DOOR SIZE
MAXIMUM
DESIGN
PRESSURE
HINGING
OPTIONS
GLAZING STOP
OPTIONS
GLASS
THICKNESS
MS 1850
3-Point Lock
4'-0" x 8'-0" (1219.2 x 2438.4) per leaf
8'-0" x 8'-0" (2438.4 x 2438.4) pairs
3'-0" x 9'-0" (914.4 x 2743.2) per leaf
6'-0" x 9'-0" (1828.8 x 2743.2) pairs
± 110 PSF
Offset Pivots
Butt Hinges
Continuous Hinge
1, 2, 3
9/16" (14.3)
1" (25.4)
Kawneer 1686
Conc. Rod Exit Device
Single 4'-0" x 8'-0" (1219.2 x 2438.4)
Pair 8'-0" x 8'-0" (2438.4 x 2438.4)
± 110 PSF
Offset Pivots
Butt Hinges
Continuous Hinge
1, 2, 3
9/16" (14.3)
1" (25.4)
Paneline®
Conc. Rod Exit Device
Single 4'-0" x 8'-0" (1219.2 x 2438.4)
Pair 8'-0" x 8'-0" (2438.4 x 2438.4)
± 70 PSF
Offset Pivots
Butt Hinges
Continuous Hinge
1, 2, 3
9/16" (14.3)
1" (25.4)
Falcon HSEC 1690
Conc. Rod Exit Device
4'-0" x 8'-0" (1219.2 x 2438.4) per leaf
8'-0" x 8'-0" (2438.4 x 2438.4) pairs
± 50 PSF
1, 2, 3
9/16" (14.3)
1" (25.4)
3'-0" x 9'-0" (914.4 x 2743.2) per leaf
6'-0" x 9'-0" (1828.8 x 2743.2) pairs
± 60 PSF
Offset Pivots
Butt Hinges
Continuous Hinge
Jackson 2086
Conc. Rod Exit Device
Single 4'-0" x 8'-0" (1219.2 x 2438.4)
Pair 8'-0" x 8'-0" (2438.4 x 2438.4)
± 90 PSF
Offset Pivots
Butt Hinges
Continuous Hinge
1, 2, 3
9/16" (14.3)
1" (25.4)
Von Duprin XP 98/99
Rim Exit Device
4'-0" x 8'-0" (1219.2 x 2438.4) per leaf
8'-0" x 8'-0" (2438.4 x 2438.4) pairs
± 50 PSF
Offset Pivots
Butt Hinges
Continuous Hinge
1, 2, 3
9/16" (14.3)
1" (25.4)
Von Duprin HSEC 9947
Conc. Rod Exit Device
4'-0" x 8'-0" (1219.2 x 2438.4) per leaf
8'-0" x 8'-0" (2438.4 x 2438.4) pairs
± 50 PSF
1, 2, 3
9/16" (14.3)
1" (25.4)
3'-0" x 9'-0" (914.4 x 2743.2) per leaf
6'-0" x 9'-0" (1828.8 x 2743.2) pairs
± 60 PSF
Offset Pivots
Butt Hinges
Continuous Hinge
Glazing Stop Options:
1 - Structural silicone with 0.090 Dupont or Solutia PVB interlayer or 0.090 Dupont Sentry Glas® interlayer.
2 - 3M VHB structural tape with 0.090 Dupont or Solutia PVB interlayer or 0.090 Dupont Sentry Glas® interlayer.
3 - Dry glazing gasket with 0.090 Dupont Sentry Glas® interlayer, only for 9/16" (14.3) infill with design pressure < or = 90 PSF.
© Kawneer Company, Inc., 2012
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
LOCKING
OPTIONS
17
kawneer.com
350/500 HEAVY WALLTM IR ENTRANCES
JUNE, 2012
350 HEAVY WALL IR DETAILS
Blast Mitigation Product
EC 97911-44
TM
350 HEAVY WALLTM IR DOORS
WITH 1600 WALL SUB-FRAMING
(Doors shown with 1" infill, tape glazed)
4
1
2
1
5
3
5
163-036
163-036
400-520
400-520
1
HINGE JAMB
3
LOCK JAMB
2
MEETING STILES
450-079
041-045
BOTTOM RAIL
WEATHERING
069-129
4
DOOR HEADER/
TRANSOM BAR
DOOR STOP USED
WITH PAIRS OF DOORS
5*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
kawneer.com
© Kawneer Company, Inc., 2012
4
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SCALE 3" = 1'-0"
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
18
JUNE, 2012
350/500 HEAVY WALLTM IR ENTRANCES
EC 97911-44
Jackson 2086
Conc. Rod Exit Device
ENTRANCE HARDWARE OFFERINGS
Blast Mitigation Product
MAXIMUM
DOOR SIZE
Single 3'-0" x 7'-0" (914.4 x 2133.6)
Pair 6'-0" x 7'-0" (1828.8 x 2133.6)
MAXIMUM
BLAST
LOADING
HINGING
OPTIONS
GLAZING STOP
OPTIONS
GLASS
THICKNESS
Peak Pressure:
5.8 PSF
Butt Hinges
1
1" (25.4)
Impulse:
41 PSI/M-SEC
Glazing Stop Options:
1 - Structural silicone with 0.090 Dupont or Solutia PVB interlayer.
© Kawneer Company, Inc., 2012
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
LOCKING
OPTIONS
kawneer.com
19
kawneer.com
© Kawneer Company, Inc., 2012
BLANK PAGE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
350/500 HEAVY WALLTM IR ENTRANCES
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
20
JUNE, 2012
EC 97911-44