350/500 Heavy Wall™ Entrances Managing Heavy Traffic with Reliability, Strength and Protection that Lasts Kohl Center, University of Wisconsin, Madison, WI Architects: Hok Sport Facilities Group, Kansas City, MO; Venture Architects, Milwaukee, WI; Heinlein & Schrock, Kansas City, MO Glazing Contractor: Lurie Glass Company, Milwaukee, WI HIGH DURABILITY – 350/500 Heavy Wall™ HURRICANE RESISTANT – 350/500 Heavy Wall™ IR Kawneer’s Medium Stile 350 and Wide Stile 500 Heavy Wall™ Entrance lines provide quality, durability and protection that lasts. The entrances were designed for heavy-traffic areas such as schools, universities and office buildings where traffic and motion create rigorous usage. 350/500 Heavy Wall™ Entrances have 3/16" (4.8 mm) walls throughout for additional strength and durability, and two framing options to provide a choice for designers. Additionally, the 350/500 Heavy Wall™ IR Entrances provide a solution for blast mitigation as well as offer hurricane resistance where they have been tested to meet the highest level of impact protection for entrances in the industry. Performance To resist both lever arm and torsion forces that constantly act upon any door, all 350/500 Heavy Wall™ Entrances feature four Sigma deep penetration and fillet welds plus mechanical fastening at each corner. In addition to the standard two-year warranty covering every Kawneer door, each door corner for the 350/500 Heavy Wall™ Entrances comes with a limited lifetime warranty, good for the life of the door under normal-use operation. Aesthetics Like all Kawneer entrances, 350/500 Heavy Wall™ Entrances offer classic lines and clean aesthetics and can blend into any type of architecture, whether traditional or modern, remodel or new construction. The door is 2" (50.8 mm) deep with 3-1/2" (88.9 mm) vertical stiles for the 350 Heavy Wall™ and 5" (127 mm) vertical stiles for the 500 Heavy Wall™ with a 6-1/2" (165.1 mm) bottom rail. A deeper 10-1/4" (260.4 mm) bottom rail is also available. Glazing infills range from 1/4" to 1" (6.4 mm to 25.4 mm). Muntins are optional and can be added to complement any design. 350/500 Heavy Wall™ Entrances provide a choice of framing: Trifab® VG (VersaGlaze®) 450 or 451 with 3/32" (2.4 mm) thickness for economical applications that do not require additional strength throughout the entire entrance. Alternatively, the Heavy Wall™ Trifab® VG framing with 3/16" (4.8 mm) wall thickness provides a solution for applications facing heavier traffic and substantial, or possibly abusive, usage. Heavy Wall™ is a single-acting entrance with offset pivots, butt hinges or continuous geared hinges. The classic lines of 350/500 Heavy Wall™ Entrances push-pull hardware blend into any design. Protective Glazing 350/500 Heavy Wall™ IR Entrances Wind-borne debris, persistent rain and internal/external pressure changes are major causes of property damage and injury stemming from violent weather, and building codes in coastal areas often require enhanced safety for occupants. To meet these needs, 350/500 Heavy Wall™ IR Entrances have been rigorously tested to meet the forces of nature as well as human directed attacks. These impact resistant entrances have been tested to meet TAS 201, 202 and 203 requirements of the Florida Building Code (FBC) as well as Level D requirements of ASTM E 1996. The entrances have also been tested to meet the even more stringent Level E (Enhanced Facilities) requirements of ASTM E 1996. For comprehensive safety assurance, 350/500 Heavy Wall™ IR Entrances have also been tested for blast mitigation per the requirements of ASTM F 1642. Montana State Fund Office Building, Helena, MT Architect: Mosaic Architecture , Helena, MT Glazing Contractor: Frontline Glass Inc., Helena, MT For the Finishing Touch Permanodic® anodized finishes are available in Class I and Class II in seven different color choices. Painted finishes, including fluoropolymer, that meet or exceed AAMA 2605 are offered in many standard choices and an unlimited number of specially designed colors. Solvent-free powder coatings add the green element with high performance, durability and scratch resistance that meet the standards of AAMA 2604. Kawneer Company, Inc. Technology Park / Atlanta 555 Guthridge Court Norcross, GA 30092 © Kawneer Company, Inc. 2012 kawneer.com 770 . 449 . 5555 LITHO IN U.S.A. Form No. 12-2146 JUNE, 2012 FEATURES Hurricane Resistant Product Blast Mitigation Product Features • 350 medium stile has 3-1/2" vertical stile, 3-1/2" top and 6-1/2" bottom rail • 500 wide stile has 5" vertical stile, 5" top and 6-1/2" bottom rail • Door is 2" deep • Door has 3/16" wall thickness • Welded corner construction • Single acting • Offset pivot, butt hinges or continuous geared hinge • Surface mounted or concealed closers • MS lock or exit device hardware • Architects Classic push-pulls • Square stops with interior silicone seal for 9/16" (14.3 mm) or 1" (25.4 mm) glazing infills • Adjustable astragal utilizing pile weathering with polymeric fin at meeting stiles • Polymeric bulb weatherstripping in door frames • Permanodic® anodized finishes in seven standard choices • Painted finishes in standard and custom choices Optional Features • Numerous push/pull options • Paneline® exit device or Paneline® EL exit device • 3/16" heavy wall frame • Crossrails and 10" Bottom Rail • Square stops with 3MTM VHBTM interior tape for 9/16" (14.3 mm) or 1" (25.4 mm) glazing infills Product Applications • 350/500 Heavy WallTM IR provides added strength for schools, institutions, office buildings and other high traffic applications where codes require windborne debris or blast mitigating protection. © Kawneer Company, Inc., 2012 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-44 350/500 HEAVY WALLTM IR ENTRANCES For specific product applications, Consult your Kawneer representative. kawneer.com 1 kawneer.com © Kawneer Company, Inc., 2012 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 350/500 HEAVY WALLTM IR ENTRANCES Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JUNE, 2012 EC 97911-44 JUNE, 2012 350/500 HEAVY WALLTM IR ENTRANCES INDEX PICTORIAL VIEW................................................................................. 5 HURRICANE RESISTANT 350 DOOR WITH TRIFAB® VG 450 FRAMING DETAILS............. 6,7 350 DOOR WITH TRIFAB® VG 451 FRAMING DETAILS............. 8,9 350 DOOR WITH IR500/501 FRAMING DETAILS................... 10,11 500 DOOR ENTRANCE DETAILS............................................ 12,13 PANELINE® / PANELINE® EL EXIT DEVICES............................... 14 CROSS RAIL / BOTTOM RAIL OPTIONS.................................... 15 ENTRANCE HARDWARE OFFERINGS.................................. 16,17 BLAST MITIGATION 350 DOOR ENTRANCE DETAILS................................................. 18 ENTRANCE HARDWARE OFFERINGS....................................... 19 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2012 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-44 3 Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com kawneer.com © Kawneer Company, Inc., 2012 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 350/500 HEAVY WALLTM IR ENTRANCES Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 JUNE, 2012 EC 97911-44 JUNE, 2012 350/500 HEAVY WALLTM IR ENTRANCES PICTORIAL VIEW #1 MECHANICAL FASTENING is accomplished by attaching a 5/16" (7.9) thick extruded aluminum channel clip to the vertical stile with 1/4"-20 heat strengthened bolts and 3/16" thick steel nut plates for a high strength welding base for attachment horizontal member. #2 SIGMA* DEEP PENETRATION PLUG WELDS are made top and bottom after the horizontal is properly positioned over the channel clip to help provide the strongest door corner joint currently available. © Kawneer Company, Inc., 2012 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-44 WELDED CORNER CONSTRUCTION * An arc welding process known as Shielded Inert Gas Metal Arc (SIGMA) or also known as Metal Inert Gas (MIG). kawneer.com #3 SIGMA* FILLET WELDS along both top and bottom webs of the rail extrusion complete the welded corner construction. 5 TM 350 HEAVY WALL IR DETAILS Hurricane Resistant Product 4 4A 1 1A 1 HINGE JAMB 9/16" INFILL TAPE GLAZED 4 4A 2 1 1A 5 1" INFILL WET GLAZED 3 5 450-547 450-547 2 MEETING STILES 450-547 1A CONTINUOUS HINGE JAMB 1" INFILL TAPE GLAZED kawneer.com © Kawneer Company, Inc., 2012 350/500 HEAVY WALLTM IR ENTRANCES Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6 JUNE, 2012 EC 97911-44 (Doors shown with 9/16" infill, wet glazed) 350 HEAVY WALLTM IR DOORS WITH TRIFAB® VG 450 CENTER DOOR FRAMING 3 LOCK JAMB 350/500 HEAVY WALLTM IR ENTRANCES JUNE, 2012 EC 97911-44 350 HEAVY WALLTM IR DETAILS Hurricane Resistant Product SCALE 3" = 1'-0" 350 HEAVY WALLTM IR DOORS WITH TRIFAB® VG 450 CENTER DOOR FRAMING (Doors shown with 9/16" infill, wet glazed) 450-545 COC WITH SINGLE ACTING OFFSET ARM 450-079 041-045 4 DOOR HEADER/ TRANSOM BAR 4A DOOR HEADER/ TRANSOM BAR BOTTOM RAIL WEATHERING 069-129 © Kawneer Company, Inc., 2012 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE ACTING DOORS DOOR STOP USED WITH PAIRS OF DOORS 5* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. kawneer.com BOTTOM RAIL WEATHERING 069-129 DOOR STOP USED WITH PAIRS OF DOORS 5* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. 7 350/500 HEAVY WALLTM IR ENTRANCES 8 JUNE, 2012 350 HEAVY WALL IR DETAILS Hurricane Resistant Product EC 97911-44 TM SCALE 3" = 1'-0" 350 HEAVY WALLTM IR DOORS WITH TRIFAB® VG 451 CENTER DOOR FRAMING (Doors shown with 9/16" infill, wet glazed) 2 3 1 1A 7 6 6A 1 1A 7 4 4 6 6A 2 3 1 1A 7 7 451-547 451-547 1 HINGE JAMB 2 MEETING STILES 3 LOCK JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 1A 6 6A 451-547 451-026 1A CONTINUOUS HINGE JAMB 9/16" INFILL TAPE GLAZED 4 TRANSOM INSERT 1" INFILL WET GLAZED 1" INFILL TAPE GLAZED kawneer.com © Kawneer Company, Inc., 2012 6 6A 5 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5 350/500 HEAVY WALLTM IR ENTRANCES JUNE, 2012 EC 97911-44 350 HEAVY WALLTM IR DETAILS Hurricane Resistant Product SCALE 3" = 1'-0" 350 HEAVY WALLTM IR DOORS WITH TRIFAB® VG 451 CENTER DOOR FRAMING (Doors shown with 9/16" infill, wet glazed) 5 TRANSOM HEAD COC WITH SINGLE ACTING OFFSET ARM 5 TRANSOM HEAD 450-022 STOPS 450-022 STOPS 451-079 451-545 041-045 6 DOOR HEADER/ TRANSOM BAR © Kawneer Company, Inc., 2012 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE ACTING DOORS 6A DOOR HEADER/ TRANSOM BAR BOTTOM RAIL WEATHERING 069-129 DOOR STOP USED WITH PAIRS OF DOORS 7* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. kawneer.com BOTTOM RAIL WEATHERING 069-129 DOOR STOP USED WITH PAIRS OF DOORS 7* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. 9 350/500 HEAVY WALLTM IR ENTRANCES 10 JUNE, 2012 350 HEAVY WALL IR DETAILS Hurricane Resistant Product EC 97911-44 TM SCALE 3" = 1'-0" 350 HEAVY WALLTM IR DOORS WITH IR500/501 DOOR FRAMING (Doors shown with 9/16" infill, wet glazed) 6 6A 2 3 1 1A 7 1 1A 7 4 4A 4 4A 6 6A 2 3 1 1A 7 7 575-051 575-051 069-177 575-052 575-052 069-177 1 HINGE JAMB 2 MEETING STILES 3 LOCK JAMB 575-051 (Mod.) 575-051 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 1A 6 6A 575-051 (Mod.) 575-033 1A CONTINUOUS HINGE JAMB 9/16" INFILL TAPE GLAZED 4 9/16" INFILL TRANSOM INSERT (IR500) 1" INFILL WET GLAZED 575-052 575-052 575-052 069-177 575-133 4A 1" INFILL TRANSOM INSERT (IR501) 1" INFILL TAPE GLAZED kawneer.com © Kawneer Company, Inc., 2012 6 6A 5 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5 350/500 HEAVY WALLTM IR ENTRANCES JUNE, 2012 EC 97911-44 350 HEAVY WALLTM IR DETAILS Hurricane Resistant Product SCALE 3" = 1'-0" 350 HEAVY WALLTM IR DOORS WITH IR500/501 DOOR FRAMING (Doors shown with 9/16" infill, wet glazed) IR501 FRAMING COC WITH SINGLE ACTING OFFSET ARM 2-1/2" (63.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. IR500 FRAMING COC WITH SINGLE ACTING OFFSET ARM 575-112 575-012 5" (69.85) 5 TRANSOM HEAD 5 TRANSOM HEAD 575-060 575-061 575-160 575-161 575-162 575-162 6 DOOR HEADER/ TRANSOM BAR © Kawneer Company, Inc., 2012 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 041-045 041-045 6A DOOR HEADER/ TRANSOM BAR BOTTOM RAIL WEATHERING 069-129 DOOR STOP USED WITH PAIRS OF DOORS 7* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. kawneer.com BOTTOM RAIL WEATHERING 069-129 DOOR STOP USED WITH PAIRS OF DOORS 7* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. 11 350/500 HEAVY WALLTM IR ENTRANCES JUNE, 2012 500 HEAVY WALL IR DETAILS Hurricane Resistant Product EC 97911-44 TM SCALE 3" = 1'-0" 500 HEAVY WALLTM IR DOORS WITH TRIFAB® VG 450 CENTER DOOR FRAMING (TRIFAB® VG 451 CENTER DOOR FRAME AND IR500/501 DOOR FRAME OPTIONAL) 2 1 1A 5 3 5 450-547 1 HINGE JAMB 2 MEETING STILES 450-547 450-547 3 LOCK JAMB 1A CONTINUOUS HINGE JAMB 9/16" INFILL TAPE GLAZED 1" INFILL WET GLAZED 1" INFILL TAPE GLAZED kawneer.com © Kawneer Company, Inc., 2012 1 1A Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 4 4A 4 4A Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 350/500 HEAVY WALLTM IR ENTRANCES JUNE, 2012 EC 97911-44 500 HEAVY WALLTM IR DETAILS Hurricane Resistant Product SCALE 3" = 1'-0" 500 HEAVY WALLTM IR DOORS WITH TRIFAB® VG 450 CENTER DOOR FRAMING (TRIFAB® VG 451 CENTER DOOR FRAME AND IR500/501 DOOR FRAME OPTIONAL) 450-545 COC WITH SINGLE ACTING OFFSET ARM 450-079 041-045 4 DOOR HEADER/ TRANSOM BAR 4A DOOR HEADER/ TRANSOM BAR BOTTOM RAIL WEATHERING © Kawneer Company, Inc., 2012 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE ACTING DOORS 069-129 DOOR STOP USED WITH PAIRS OF DOORS 5* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. kawneer.com BOTTOM RAIL WEATHERING 069-129 DOOR STOP USED WITH PAIRS OF DOORS 5* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. 13 350/500 HEAVY WALLTM IR ENTRANCES 14 JUNE, 2012 PANELINE / PANELINE EL EXIT DEVICE Hurricane Resistant Product ® SCALE 3" = 1'-0" EC 97911-44 ® PANELINE® EXIT DEVICE The Paneline® concealed rod exit device will accommodate variations in door width as shown in the following illustrations. Sidelites adjacent to Paneline equipped doors not requiring exit devices may be fitted with fixed panels as detailed below to match the general appearance of the Paneline cross rail. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. The Optional Paneline® EL device is designed for electrified access control and is compatible with most key pad and card reader systems. See Hardware Section for complete description of Paneline hardware, including finish of units. Paneline® uses mortise cylinder in lieu of the normal rim-type. Dummy Paneline units should not use any type of lock. 1-1/8" (27.8) 1" (25.4) INTERIOR ELEVATION INTERIOR VIEW CROSS RAIL WITH EXIT DEVICE AND CPN PULL HANDLE LOCK STILE TRIM FILLER WIDTH VARIES WITH STILE WIDTH 3'-01/8" (917.8) TO BOTTOM OF DOOR PANELINE® EL COMPONENTS DOGGING LOCK (TYPICAL) PUSH 5 7/8" (149.2) 1'-11 5/16" (592.1) ACTIVE PUSH PANEL FIXED WIDTH DOOR OPENING WIDTH PIVOT STILE TRIM FILLER WIDTH VARIES WITH DOOR WIDTH POWER TRANSFER INTERMEDIATE BUTT HINGE POWER TRANSFER INTERMEDIATE OFFSET PIVOT 4'-0" (1219.2) MAX. - 2'-10 13/32" (873.9) MIN. 3'-0" (914.6) ADA MIN. EXTERIOR VIEW "CPN" PULL AND OPTIONAL CYLINDER GUARD SHOWN ELECTRIC POWER TRANSFER (EPT) SP 1000 POWER SUPPLY kawneer.com © Kawneer Company, Inc., 2012 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 7-1/8" (181.0) PUSH 8-7/16" (214.3) 2" (50.8) © Kawneer Company, Inc., 2012 10" (254) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3-1/2" CROSS RAIL WITH 9/16" INFILL kawneer.com 8-7/16" (214.3) 6" (152.4) 3-1/2" (88.9) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2012 350/500 HEAVY WALLTM IR ENTRANCES EC 97911-44 SCALE 3" = 1'-0" CROSS RAIL / BOTTOM RAIL OPTIONS Hurricane Resistant Product 6" CROSS RAIL WITH 9/16" INFILL 10" BOTTOM RAIL 8-1/4" CROSS RAIL WITH 9/16" INFILL 200-183 200-184 200-185 15 350/500 HEAVY WALLTM IR ENTRANCES JUNE, 2012 ENTRANCE HARDWARE OFFERINGS Hurricane Resistant Product EC 97911-44 Door Sizes OPTIONAL Maximum Size: 4'-0" x 8'-0" (1219.2 x 2438.4) per leaf 8'-0" x 8'-0" (2438.4 x 2438.4) pairs 3'-0" x 9'-0" (914.4 x 2743.2) per leaf 6'-0" x 9'-0" (1828.8 x 2743.2) pairs Sizes up to maximum per leaf or pair Glass Stops Square stops for 9/16" (14.3) infill, interior screw applied glass stop with silicone seal Square stops for 9/16" (14.3) or 1" (25.4) infill, interior screw applied glass stop with 3M VHB structural tape. Door Frames IR500 frame = 2-1/2" x 5" (63.5 x 127) - *IR 501 frame = 2-1/2" x 5" (63.5 x 127) - Trifab® VG 450 non-transom or sidelites - Trifab® VG 451 (50.8 x 114.3) - 1600 sub-frame with door jamb adaptors and sub-head Architects Classic Hardware: - CO-9 Pull and CP-II Push Bar - CO-9 Pull with Exit Devices - CO-9 Pull with Paneline® Exit Device Supplied by others Norton 1601 Adjustable or 1601 BF Adjustable Surface Closer with back-check, with or without adjustable hold open Surface Closers: - Norton 8100 BF - LCN 4040, LCN 1260 adjustable - Dor-O-Matic/Falcon SC 60 Push-Pulls Door Closers **Concealed Closers - Standard COC with single acting offset arm - LCN 2030, LCN 5030 Kawneer Top, Bottom and Intermediate offset pivots Locking MS 1850 Deadbolt 3-Point Lock with 4016 Top Bolt and 4056 Bottom Bolt Exit Device Hardware Kawneer 1686 Concealed Exit Device Threshold Kawneer Threshold 1/2" x 4-3/8" (12.7 x 111.1) Weathering Sealair® bulb polymeric weathering in door frames, adjustable bottom rail sweep with EPDM blade and adjustable astragal utilizing pile weathering with polymeric fin at meeting stiles - Kawneer 4-1/2" x 4" (114.3 x 101.6) Top, Bottom and Intermediate (NRP) Butt Hinge - Continuous Geared Hinge - Kawneer Paneline® Conc. Rod Exit Device - Kawneer Paneline® EL Conc. Rod Exit Device - Falcon HSEC1690 Conc. Rod Exit Device - Jackson 2086 Conc. Rod Exit Device - Jackson 2086 EL Conc. Rod Exit Device - Von Duprin HSEC9947 Conc. Rod Exit Device - Von Duprin XP 98/99 Rim Exit Device Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Hinging NOTE: *IR 501 door frame uses IR 500 door jamb with IR 501 filler, (assembly has not been impact tested). **Concealed Overhead Closer requires Trifab® VG 450 frame, Trifab® VG 450 sub-header, or 1600 Wall System®1 sub-frame. kawneer.com © Kawneer Company, Inc., 2012 STANDARD Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 16 JUNE, 2012 350/500 HEAVY WALLTM IR ENTRANCES EC 97911-44 ENTRANCE HARDWARE OFFERINGS Hurricane Resistant Product MAXIMUM DOOR SIZE MAXIMUM DESIGN PRESSURE HINGING OPTIONS GLAZING STOP OPTIONS GLASS THICKNESS MS 1850 3-Point Lock 4'-0" x 8'-0" (1219.2 x 2438.4) per leaf 8'-0" x 8'-0" (2438.4 x 2438.4) pairs 3'-0" x 9'-0" (914.4 x 2743.2) per leaf 6'-0" x 9'-0" (1828.8 x 2743.2) pairs ± 110 PSF Offset Pivots Butt Hinges Continuous Hinge 1, 2, 3 9/16" (14.3) 1" (25.4) Kawneer 1686 Conc. Rod Exit Device Single 4'-0" x 8'-0" (1219.2 x 2438.4) Pair 8'-0" x 8'-0" (2438.4 x 2438.4) ± 110 PSF Offset Pivots Butt Hinges Continuous Hinge 1, 2, 3 9/16" (14.3) 1" (25.4) Paneline® Conc. Rod Exit Device Single 4'-0" x 8'-0" (1219.2 x 2438.4) Pair 8'-0" x 8'-0" (2438.4 x 2438.4) ± 70 PSF Offset Pivots Butt Hinges Continuous Hinge 1, 2, 3 9/16" (14.3) 1" (25.4) Falcon HSEC 1690 Conc. Rod Exit Device 4'-0" x 8'-0" (1219.2 x 2438.4) per leaf 8'-0" x 8'-0" (2438.4 x 2438.4) pairs ± 50 PSF 1, 2, 3 9/16" (14.3) 1" (25.4) 3'-0" x 9'-0" (914.4 x 2743.2) per leaf 6'-0" x 9'-0" (1828.8 x 2743.2) pairs ± 60 PSF Offset Pivots Butt Hinges Continuous Hinge Jackson 2086 Conc. Rod Exit Device Single 4'-0" x 8'-0" (1219.2 x 2438.4) Pair 8'-0" x 8'-0" (2438.4 x 2438.4) ± 90 PSF Offset Pivots Butt Hinges Continuous Hinge 1, 2, 3 9/16" (14.3) 1" (25.4) Von Duprin XP 98/99 Rim Exit Device 4'-0" x 8'-0" (1219.2 x 2438.4) per leaf 8'-0" x 8'-0" (2438.4 x 2438.4) pairs ± 50 PSF Offset Pivots Butt Hinges Continuous Hinge 1, 2, 3 9/16" (14.3) 1" (25.4) Von Duprin HSEC 9947 Conc. Rod Exit Device 4'-0" x 8'-0" (1219.2 x 2438.4) per leaf 8'-0" x 8'-0" (2438.4 x 2438.4) pairs ± 50 PSF 1, 2, 3 9/16" (14.3) 1" (25.4) 3'-0" x 9'-0" (914.4 x 2743.2) per leaf 6'-0" x 9'-0" (1828.8 x 2743.2) pairs ± 60 PSF Offset Pivots Butt Hinges Continuous Hinge Glazing Stop Options: 1 - Structural silicone with 0.090 Dupont or Solutia PVB interlayer or 0.090 Dupont Sentry Glas® interlayer. 2 - 3M VHB structural tape with 0.090 Dupont or Solutia PVB interlayer or 0.090 Dupont Sentry Glas® interlayer. 3 - Dry glazing gasket with 0.090 Dupont Sentry Glas® interlayer, only for 9/16" (14.3) infill with design pressure < or = 90 PSF. © Kawneer Company, Inc., 2012 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. LOCKING OPTIONS 17 kawneer.com 350/500 HEAVY WALLTM IR ENTRANCES JUNE, 2012 350 HEAVY WALL IR DETAILS Blast Mitigation Product EC 97911-44 TM 350 HEAVY WALLTM IR DOORS WITH 1600 WALL SUB-FRAMING (Doors shown with 1" infill, tape glazed) 4 1 2 1 5 3 5 163-036 163-036 400-520 400-520 1 HINGE JAMB 3 LOCK JAMB 2 MEETING STILES 450-079 041-045 BOTTOM RAIL WEATHERING 069-129 4 DOOR HEADER/ TRANSOM BAR DOOR STOP USED WITH PAIRS OF DOORS 5* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. kawneer.com © Kawneer Company, Inc., 2012 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 JUNE, 2012 350/500 HEAVY WALLTM IR ENTRANCES EC 97911-44 Jackson 2086 Conc. Rod Exit Device ENTRANCE HARDWARE OFFERINGS Blast Mitigation Product MAXIMUM DOOR SIZE Single 3'-0" x 7'-0" (914.4 x 2133.6) Pair 6'-0" x 7'-0" (1828.8 x 2133.6) MAXIMUM BLAST LOADING HINGING OPTIONS GLAZING STOP OPTIONS GLASS THICKNESS Peak Pressure: 5.8 PSF Butt Hinges 1 1" (25.4) Impulse: 41 PSI/M-SEC Glazing Stop Options: 1 - Structural silicone with 0.090 Dupont or Solutia PVB interlayer. © Kawneer Company, Inc., 2012 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. LOCKING OPTIONS kawneer.com 19 kawneer.com © Kawneer Company, Inc., 2012 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 350/500 HEAVY WALLTM IR ENTRANCES Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 20 JUNE, 2012 EC 97911-44