350/500 Heavy Wall™ Entrances Managing Heavy Traffic with Reliability, Strength and Protection that Lasts Kohl Center, University of Wisconsin, Madison, WI Architects: Hok Sport Facilities Group, Kansas City, MO; Venture Architects, Milwaukee, WI; Heinlein & Schrock, Kansas City, MO Glazing Contractor: Lurie Glass Company, Milwaukee, WI HIGH DURABILITY – 350/500 Heavy Wall™ HURRICANE RESISTANT – 350/500 Heavy Wall™ IR Kawneer’s Medium Stile 350 and Wide Stile 500 Heavy Wall™ Entrance lines provide quality, durability and protection that lasts. The entrances were designed for heavy-traffic areas such as schools, universities and office buildings where traffic and motion create rigorous usage. 350/500 Heavy Wall™ Entrances have 3/16" (4.8 mm) walls throughout for additional strength and durability, and two framing options to provide a choice for designers. Additionally, the 350/500 Heavy Wall™ IR Entrances provide a solution for blast mitigation as well as offer hurricane resistance where they have been tested to meet the highest level of impact protection for entrances in the industry. Performance To resist both lever arm and torsion forces that constantly act upon any door, all 350/500 Heavy Wall™ Entrances feature four Sigma deep penetration and fillet welds plus mechanical fastening at each corner. In addition to the standard two-year warranty covering every Kawneer door, each door corner for the 350/500 Heavy Wall™ Entrances comes with a limited lifetime warranty, good for the life of the door under normal-use operation. Aesthetics Like all Kawneer entrances, 350/500 Heavy Wall™ Entrances offer classic lines and clean aesthetics and can blend into any type of architecture, whether traditional or modern, remodel or new construction. The door is 2" (50.8 mm) deep with 3-1/2" (88.9 mm) vertical stiles for the 350 Heavy Wall™ and 5" (127 mm) vertical stiles for the 500 Heavy Wall™ with a 6-1/2" (165.1 mm) bottom rail. A deeper 10-1/4" (260.4 mm) bottom rail is also available. Glazing infills range from 1/4" to 1" (6.4 mm to 25.4 mm). Muntins are optional and can be added to complement any design. 350/500 Heavy Wall™ Entrances provide a choice of framing: Trifab® VG (VersaGlaze®) 450 or 451 with 3/32" (2.4 mm) thickness for economical applications that do not require additional strength throughout the entire entrance. Alternatively, the Heavy Wall™ Trifab® VG framing with 3/16" (4.8 mm) wall thickness provides a solution for applications facing heavier traffic and substantial, or possibly abusive, usage. Heavy Wall™ is a single-acting entrance with offset pivots, butt hinges or continuous geared hinges. The classic lines of 350/500 Heavy Wall™ Entrances push-pull hardware blend into any design. Protective Glazing 350/500 Heavy Wall™ IR Entrances Wind-borne debris, persistent rain and internal/external pressure changes are major causes of property damage and injury stemming from violent weather, and building codes in coastal areas often require enhanced safety for occupants. To meet these needs, 350/500 Heavy Wall™ IR Entrances have been rigorously tested to meet the forces of nature as well as human directed attacks. These impact resistant entrances have been tested to meet TAS 201, 202 and 203 requirements of the Florida Building Code (FBC) as well as Level D requirements of ASTM E 1996. The entrances have also been tested to meet the even more stringent Level E (Enhanced Facilities) requirements of ASTM E 1996. For comprehensive safety assurance, 350/500 Heavy Wall™ IR Entrances have also been tested for blast mitigation per the requirements of ASTM F 1642. Montana State Fund Office Building, Helena, MT Architect: Mosaic Architecture , Helena, MT Glazing Contractor: Frontline Glass Inc., Helena, MT For the Finishing Touch Permanodic® anodized finishes are available in Class I and Class II in seven different color choices. Painted finishes, including fluoropolymer, that meet or exceed AAMA 2605 are offered in many standard choices and an unlimited number of specially designed colors. Solvent-free powder coatings add the green element with high performance, durability and scratch resistance that meet the standards of AAMA 2604. Kawneer Company, Inc. Technology Park / Atlanta 555 Guthridge Court Norcross, GA 30092 © Kawneer Company, Inc. 2012 kawneer.com 770 . 449 . 5555 LITHO IN U.S.A. Form No. 12-2146 JUNE, 2011 350/500 HEAVY WALLTM ENTRANCES FEATURES Features • 350 medium stile has 3-1/2" vertical stile, 3-1/2" top and 6-1/2" bottom rail • 500 wide stile has 5" vertical stile, 5" top and 6-1/2" bottom rail • Door is 2" deep • Door has 3/16" wall thickness • Dual moment welded corner construction • Single acting • Offset pivot, butt hinges or continuous geared hinge • Surface mounted or concealed closers • MS lock or exit device hardware • Architects Classic push-pulls • 1/4", 5/8" or 1" infills • Adjustable astragal utilizing pile weathering with polymeric fin at meeting stiles • Sealair® bulb polymeric weatherstripping in door frames • Permanodic® anodized finishes in seven standard choices • Painted finishes in standard and custom choices Optional Features • Numerous push/pull options • Paneline® exit device or Paneline® EL exit device • 3/16" heavy wall frame Product Applications • Designed for high traffic applications such as schools, universities and office buildings © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-30 For specific product applications, Consult your Kawneer representative. kawneer.com 1 kawneer.com © Kawneer Company, Inc., 2011 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 350/500 HEAVY WALLTM ENTRANCES Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JUNE, 2011 EC 97911-30 JUNE, 2011 350/500 HEAVY WALLTM ENTRANCES INDEX PICTORIAL VIEW................................................................................. 5 350 HEAVY WALL CONSTRUCTION DETAILS................................ 6-9 500 HEAVY WALL CONSTRUCTION DETAILS............................ 10-13 ENTRANCE PACKAGES............................................................... 14,15 ENTRANCE OFFERINGS.............................................................. 16,17 PUSH-PULL HARDWARE / EXIT DEVICES...................................... 18 PANELINE® / PANELINE® EL EXIT DEVICE...................................... 19 OPTIONS AND ACCESSORIES........................................................ 20 THERMAL CHARTS...................................................................... 21-33 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-30 3 Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com kawneer.com © Kawneer Company, Inc., 2011 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 350/500 HEAVY WALLTM ENTRANCES Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 JUNE, 2011 EC 97911-30 JUNE, 2011 350/500 HEAVY WALLTM ENTRANCES PICTORIAL VIEW #1 MECHANICAL FASTENING is accomplished by attaching a 5/16" (7.9) thick extruded aluminum channel clip to the vertical stile with 1/4"-20 heat strengthened bolts and 3/16" thick steel nut plates for a high strength welding base for attachment horizontal member. #2 SIGMA* DEEP PENETRATION PLUG WELDS are made top and bottom after the horizontal is properly positioned over the channel clip to help provide the strongest door corner joint currently available. © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-30 DUAL MOMENT CORNER CONSTRUCTION * An arc welding process known as Shielded Inert Gas Metal Arc (SIGMA) or also known as Metal Inert Gas (MIG). kawneer.com #3 SIGMA* FILLET WELDS along both top and bottom webs of the rail extrusion complete the Dual Moment corner construction. 5 350/500 HEAVY WALLTM ENTRANCES 6 JUNE, 2011 350 HEAVY WALL CONSTRUCTION DETAILS SCALE 3" = 1'-0" EC 97911-30 350 HEAVY WALL DOORS TRIFAB® VG 450 CENTER DOOR FRAMES SHOWN (HEAVY WALL FRAME OPTIONAL) 7 6 or 6A 1 or 1A 2 1 or 1A 4 or 4A 5 4 or 4A 9 6 or 6A 8 or 8A,8B 8 or 8A,8B 8 or 8A 3 or 3A 1 or 1A 2 1 or 1A 4 or 4A 5 4 or 4A 9 9 3 or 3A 9 450-547 450-547 3 LOCK JAMB 1 HINGE JAMB 2 MEETING STILES 1A HINGE JAMB 450-499 3A LOCK JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 450-499 450-547 4 HINGE JAMB 450-033 6 TRANSOM INSERT 450-499 4A HINGE JAMB 450-097 6A TRANSOM INSERT kawneer.com © Kawneer Company, Inc., 2011 8 or 8A Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 7 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 350 HEAVY WALL CONSTRUCTION DETAILS SCALE 3" = 1'-0" 350 HEAVY WALL DOORS TRIFAB® VG 450 CENTER DOOR FRAMES SHOWN (HEAVY WALL FRAME OPTIONAL) COC WITH SINGLE ACTING OFFSET ARM 7 TRANSOM HEAD 7 TRANSOM HEAD 450-022 STOPS 450-022 STOPS 450-545 450-498 450-022 STOPS 450-079 041-045 8A DOOR HEADER/ TRANSOM BAR 8 DOOR HEADER/ TRANSOM BAR © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE ACTING DOORS 8B DOOR HEADER/ TRANSOM BAR 200-799 BOTTOM RAIL WEATHERING (OPTIONAL) 069-129 069-129 9* BOTTOM RAIL 9* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. kawneer.com 200-799 BOTTOM RAIL WEATHERING (OPTIONAL) *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. 7 350/500 HEAVY WALLTM ENTRANCES 8 JUNE, 2011 350 HEAVY WALL CONSTRUCTION DETAILS SCALE 3" = 1'-0" EC 97911-30 350 HEAVY WALL DOORS TRIFAB® VG 451 CENTER DOOR FRAMES SHOWN (HEAVY WALL FRAME OPTIONAL) 7 6 or 6A 8 or 8A 1 or 1A 2 1 or 1A 4 or 4A 5 4 or 4A 9 6 or 6A 8 or 8A,8B 8 or 8A,8B 3 or 3A 1 or 1A 2 1 or 1A 4 or 4A 5 4 or 4A 9 9 3 or 3A 9 451-547 451-547 3 LOCK JAMB 1 HINGE JAMB 2 MEETING STILES 1A HINGE JAMB 451-499 3A LOCK JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 451-499 451-547 4 HINGE JAMB 451-026 6 TRANSOM INSERT 451-499 4A HINGE JAMB 451-097 6A TRANSOM INSERT kawneer.com © Kawneer Company, Inc., 2011 8 or 8A Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 7 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 350 HEAVY WALL CONSTRUCTION DETAILS SCALE 3" = 1'-0" 350 HEAVY WALL DOORS TRIFAB® VG 451 CENTER DOOR FRAMES SHOWN (HEAVY WALL FRAME OPTIONAL) COC WITH SINGLE ACTING OFFSET ARM 7 TRANSOM HEAD 7 TRANSOM HEAD 450-022 STOPS 450-022 STOPS 451-498 451-545 450-022 STOPS 451-079 041-045 8A DOOR HEADER/ TRANSOM BAR 8 DOOR HEADER/ TRANSOM BAR © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE ACTING DOORS 8B DOOR HEADER/ TRANSOM BAR 200-799 BOTTOM RAIL WEATHERING (OPTIONAL) 069-129 069-129 9* BOTTOM RAIL 9* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. kawneer.com 200-799 BOTTOM RAIL WEATHERING (OPTIONAL) *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. 9 350/500 HEAVY WALLTM ENTRANCES 10 JUNE, 2011 500 HEAVY WALL CONSTRUCTION DETAILS SCALE 3" = 1'-0" EC 97911-30 500 HEAVY WALL DOORS TRIFAB® VG 450 CENTER DOOR FRAMES SHOWN (HEAVY WALL FRAME OPTIONAL) 7 6 or 6A 8 or 8A 1 or 1A 2 1 or 1A 4 or 4A 5 4 or 4A 9 6 or 6A 8 or 8A,8B 8 or 8A,8B 8 or 8A 3 or 3A 1 or 1A 2 1 or 1A 4 or 4A 5 4 or 4A 9 9 3 or 3A 9 450-547 450-547 3 LOCK JAMB 1 HINGE JAMB 2 MEETING STILES Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 7 450-499 450-499 450-547 4 HINGE JAMB 450-033 6 TRANSOM INSERT 450-499 4A HINGE JAMB 450-097 6A TRANSOM INSERT kawneer.com © Kawneer Company, Inc., 2011 3A LOCK JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1A HINGE JAMB 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 500 HEAVY WALL CONSTRUCTION DETAILS SCALE 3" = 1'-0" 500 HEAVY WALL DOORS TRIFAB® VG 450 CENTER DOOR FRAMES SHOWN (HEAVY WALL FRAME OPTIONAL) COC WITH SINGLE ACTING OFFSET ARM 7 TRANSOM HEAD 7 TRANSOM HEAD 450-022 STOPS 450-022 STOPS 450-545 450-498 450-022 STOPS 450-079 041-045 8A DOOR HEADER/ TRANSOM BAR 8 DOOR HEADER/ TRANSOM BAR © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE ACTING DOORS 8B DOOR HEADER/ TRANSOM BAR 200-799 BOTTOM RAIL WEATHERING (OPTIONAL) 069-129 069-129 9* BOTTOM RAIL 9* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. kawneer.com 200-799 BOTTOM RAIL WEATHERING (OPTIONAL) *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. 11 350/500 HEAVY WALLTM ENTRANCES 12 JUNE, 2011 500 HEAVY WALL CONSTRUCTION DETAILS SCALE 3" = 1'-0" EC 97911-30 500 HEAVY WALL DOORS TRIFAB® VG 451 CENTER DOOR FRAMES SHOWN (HEAVY WALL FRAME OPTIONAL) 7 6 or 6A 8 or 8A 8 or 8A 1 or 1A 2 1 or 1A 4 or 4A 5 4 or 4A 3 or 3A 1 or 1A 2 1 or 1A 4 or 4A 5 4 or 4A 9 9 3 or 3A 9 451-547 451-547 3 LOCK JAMB 1 HINGE JAMB 2 MEETING STILES 451-499 451-499 3A LOCK JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1A HINGE JAMB 451-547 4 HINGE JAMB 451-026 6 TRANSOM INSERT 451-499 4A HINGE JAMB 451-097 6A TRANSOM INSERT kawneer.com © Kawneer Company, Inc., 2011 9 6 or 6A 8 or 8A,8B 8 or 8A,8B Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 7 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 500 HEAVY WALL CONSTRUCTION DETAILS SCALE 3" = 1'-0" 500 HEAVY WALL DOORS TRIFAB® VG 451 CENTER DOOR FRAMES SHOWN (HEAVY WALL FRAME OPTIONAL) COC WITH SINGLE ACTING OFFSET ARM 7 TRANSOM HEAD 7 TRANSOM HEAD 450-022 STOPS 450-022 STOPS 451-498 451-545 450-022 STOPS 451-079 041-045 8A DOOR HEADER/ TRANSOM BAR 8 DOOR HEADER/ TRANSOM BAR © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE ACTING DOORS 8B DOOR HEADER/ TRANSOM BAR 200-799 BOTTOM RAIL WEATHERING (OPTIONAL) 069-129 069-129 9* BOTTOM RAIL 9* BOTTOM RAIL *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. kawneer.com 200-799 BOTTOM RAIL WEATHERING (OPTIONAL) *NOTE: Some building codes limit threshold height to 1/2" (12.7) max. 13 SINGLE ACTING DOOR WITHOUT TRANSOM 3/16" (4.3) 3/16" (4.3) 6-1/2" (165.1) 6-1/2" (165.1) 1/8" (3.2) 1/4" (6.4) ENTRANCE PACKAGES SINGLE ACTING DOOR WITH TRANSOM kawneer.com © Kawneer Company, Inc., 2011 3-17/32" (89.7) 1/8" (3.2) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DOOR OPENING FRAME DIMENSION MASONRY OPENING 3-17/32" (89.7) 1/4" (6.4) 350/500 HEAVY WALLTM ENTRANCES Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1/2" (12.7) 11/16" (17.5) 1/2" (12.7) 11/16" (17.5) DOOR OPENING FRAME DIMENSION MASONRY OPENING 14 JUNE, 2011 EC 97911-30 SCALE 3" = 1'-0" TRIFAB® VG 450 CENTER DOOR FRAMES SHOWN (TRIFAB® VG 451 CENTER DOOR FRAMES SIMILAR) 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 15 ENTRANCE PACKAGES SCALE 3" = 1'-0" MASONRY OPENING FRAME DIMENSION 2" (50.8) 3/32" (2.4) 1/8" (3.2) 1/4" (6.4) 3-9/16" (90.5) 3-1/2" (typ.) (88.9) 1/8" (3.2) 3/32" (2.4) 1/4" (6.4) SINGLE ACTING DOORS MASONRY OPENING FRAME DIMENSION 1/8" (3.2) DOOR OPENING 1/4" (6.4) 11/32" (8.7) CONTINUOUS HINGE JAMB © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DOOR OPENING kawneer.com Door Opening Dimension 3' 1/2" x 7' 0" (927.1 x 2134) 3' 6" x 7' 0" (1066.8 x 2134) 6' 0" x 7' 0" (1829 x 2134) STANDARD SIZE TRIFAB® VG 450 CENTER DOOR FRAMES WITHOUT TRANSOM Overall Frame Dimension 3' 4" x 7' 1-3/4" (1016 x 2178) 3' 9-1/2" x 7' 1-3/4" (1155.7 x 2178) 6' 3-1/2" x 7' 1-3/4" (1918 x 2178) Masonry Opening Dimension 3' 4-1/2" x 7' 2" (1028.7 x 2185) 3' 10" x 7' 2" (1168.4 x 2185) 6' 4" x 7' 2" (1930 x 2185) Door Opening Dimension Unchanged from above WITH TRANSOM Overall Frame Dimension Add 3' 1-3/4" (959) to above heights Masonry Opening Dimension Add 3' 1-3/4" (959) to above heights Door Opening Dimension 3' 1/2" x 7' 0" (927.1 x 2134) 3' 6" x 7' 0" (1066.8 x 2134) 6' 0" x 7' 0" (1829 x 2134) STANDARD SIZE TRIFAB® VG 451 CENTER DOOR FRAMES WITHOUT TRANSOM Overall Frame Dimension 3' 4" x 7' 1-3/4" (1016 x 2178) 3' 9-1/2" x 7' 1-3/4" (1155.7 x 2178) 6' 3-1/2" x 7' 1-3/4" (1918 x 2178) Masonry Opening Dimension 3' 4-1/2" x 7' 2" (1028.7 x 2185) 3' 10" x 7' 2" (1168.4 x 2185) 6' 4" x 7' 2" (1930 x 2185) Door Opening Dimension Unchanged from above WITH TRANSOM Overall Frame Dimension Add 3' 1-3/4" (959) to above heights Masonry Opening Dimension Add 3' 1-3/4" (959) to above heights 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 ENTRANCE OFFERINGS EC 97911-30 OPTIONAL Standard sizes shown on Page 15. Any size up to 4' x 8' (1219 x 2438) Glass Stops Beveled glass stops for 3/16" (4.0) or 1/4" (6.4) infill. Square glass stops for 3/16" (4.0) or 1/4" (6.4) infill. Also 1" (25.4) infill. Door Frames • Trifab® VG 450 Center - 1-3/4" x 4-1/2" (44.5 x 114.3) for single glazing. • Trifab® VG 451 Center - 2" x 4-1/2" (50.8 x 114.3) for double glazing. • Heavy Wall Trifab® VG 450 Center - (3/16" Wall). • Heavy Wall Trifab® VG 451 Center - (3/16" Wall). Push-Pulls Single Acting: • Architects Classic Style "CO-9" Pull and "CP-II" Push bar. • Architects Classic Style "CO-9" Pull and "CP" Push bar. Single Acting: • Architects Classic Style "CO-12" Pull and "CP-II" Push bar. • Architects Classic Style "CO-12" Pull and "CP" Push bar. • Architects Classic Style "CO-9" / "CO-9" Pull. • Architects Classic Style "CO-12" / "CP-12" Pull. Door Closers Single Acting: •Norton 1601 adjustable or 1601 BF adjustable surface closer with back-check, and with or without hold-open. Single Acting: •LCN 1260 adjustable •LCN 4040 surface closer with or without adjustable hold-open. •Standard COC with single acting offset arm. •Norton 8100 surface closer with 50% spring power adjustment (for opening forces of less than 8 pounds.) Closer is available with standard back-checks and with or without the hold-open feature. •Door-O-Matic/Falcon SC 60 surface closer. Pivots / Butts Single Acting: •Kawneer top and bottom offset pivots. •Kawneer top and bottom 4-1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with non-removable pin (NRP). •Continuous Hinge. Intermediate Pivots / Butts Single Acting: •Kawneer optional intermediate pivot. •Kawneer 4-1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with non-removable pin (NRP). Note: Offset Pivots are not available for use with Heavy Wall Frames. Power Transfers Single Acting: •Kawneer optional intermediate pivot with wire transfer. •Kawneer standard (4-1/2" x 4") (114.3 x 101.6) ball bearing (NRP) butt hinge with wire transfer. •EPT (Electric Power Transfer) Power Supply •SP 1000 Power Supply Locks (Active Leaf) Adams-Rite MS 1850A Deadlock with two 1-5/32" (29.4) diameter 5 pin cylinders. • Adams-Rite #4510 Latch Lock. • Adams-Rite #1850A-500 Short throw Deadlock. • Adams-Rite #1850A-505 Hookbolt Lock. • Adams-Rite #4015 Two-point Lock. • Adams-Rite #4085 Three-point Lock. • Adams-Rite #4089 Exit Indicator. • Kawneer Cylinder Guard. • Kawneer Thumbturn (in lieu of cylinder). kawneer.com © Kawneer Company, Inc., 2011 Door Sizes Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. STANDARD Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 16 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-30 17 ENTRANCE OFFERINGS STANDARD OPTIONAL Locks (Inactive Leaf) One pair of Kawneer flush bolts in the inactive leaf of a pair of doors. Controller® 3-point locking system consisting of a two point locking device in the inactive leaf in lieu of flush bolts, working in conjunction with the MS 1850A deadlock in the active leaf. This combination provides for greater security than possible with flush bolts and complies with the life safety considerations of building codes which prohibit the use of flush bolts. Threshold A 1/2" x 4" (12.7 x 101.6) aluminum mill finish threshold. Weathering SEALAIR ® Weathering system in the door and frame consisting of a dense, bulb polymeric material, which remains resilient and retains its weathering ability under temperature extremes. (The system is complete with an optional EPDM blade gasket sweep strip applied to the bottom door rail with concealed fasteners.) Bottom Door Sweep Exit Devices •Kawneer 1686 concealed rod exit device with or without a rim type cylinder. •Paneline® is a concealed rod exit device applicable to single or pairs of doors. It features an activating panel contained within the door crossrail. •Kawneer 1786 rim type exit device with or without a rim type cylinder. •Paneline® EL is a concealed rod exit device applicable to single or pairs of doors. The device is designed for electrified access control and is compatible with most key pad and card reader systems. •Dor-O-Matic/Falcon 1490 is a concealed rod exit device with or without a rim type cylinder. •Dor-O-Matic/Falcon 1590 is a rim type exit device with or without a rim type cylinder. •Dor-O-Matic/Falcon 1790 rim type exit device with or without a rim type cylinder. •Dor-O-Matic/Falcon EL 1690 concealed rod exit device with or without a rim type cylinder. The device is designed for electrified access control and is compatible with most key pad and card reader systems. •Dor-O-Matic/Falcon EL 1790 rim type exit device with or without a rim type cylinder. The device is designed for electrified access control and is compatible with most key pad and card reader systems. •Dor-O-Matic/Falcon 1990 is a concealed rod exit device with or without a rim type cylinder. •Dor-O-Matic/Falcon 2090 is a rim type exit device with or without a rim type cylinder. © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. •Dor-O-Matic/Falcon 1690 concealed rod exit device with or without a rim type cylinder. Exit Device Pulls Exit Device Pulls •Architects Classic style "CO-9" Pull. •Architects Classic style "CPN" Pull for Paneline® and Paneline® EL exit devices. •Architects Classic style "CO-12" Pull (except for Paneline® and Paneline® EL exit devices). Reference Hardware section for additional information kawneer.com 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 PUSH-PULL HARDWARE / EXIT DEVICES EC 97911-30 ARCHITECTS CLASSIC (PUSH-PULL SETS) Refer to HARDWARE SECTION for complete hardware information. SINGLE ACTING DOORS USE A PULL HANDLE AND PUSH BAR. CP-II / CP-II CO-9 / CP CO-12 / CP CO-9 / CP-II CO-12 / CP-II CP / CP CO-9 / CO-9 CO-12 / CO-12 ARCHITECTS CLASSIC (COMPONENTS) "CO-9" PULL "CO-12" PULL "CP-II" PUSH BAR Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 18 "CP" PUSH BAR RIM LATCH EXIT DEVICE Kawneer 1786 "CO-9" PULL CONCEALED ROD EXIT DEVICE Dor-O-Matic/Falcon 1990 "CO-12" PULL CONCEALED ROD EXIT DEVICE Dor-O-Matic/Falcon 1690 Dor-O-Matic/Falcon EL 1690 RIM LATCH EXIT DEVICE Dor-O-Matic/Falcon 1790 Dor-O-Matic/Falcon EL 1790 RIM LATCH EXIT DEVICE Dor-O-Matic/Falcon 2090 kawneer.com © Kawneer Company, Inc., 2011 CONCEALED ROD EXIT DEVICE Kawneer 1686 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. EXIT DEVICES and EXIT DEVICE PULLS 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 19 PANELINE® / PANELINE® EL EXIT DEVICE PANELINE® EXIT DEVICE SCALE 3" = 1'-0" The Paneline® concealed rod exit device will accommodate variations in door width as shown in the following illustrations. Sidelites adjacent to Paneline equipped doors not requiring exit devices may be fitted with fixed panels as detailed below to match the general appearance of the Paneline cross rail. See Hardware Section for complete description of Paneline hardware, including finish of units. Paneline uses mortise cylinder in lieu of the normal rim-type. Dummy Paneline units should not use any type of lock. 2" (50.8) INTERIOR ELEVATIONS 1-1/8" (27.8) 1/8" (3.2) NOTE: Sidelites must be stop glazed above and below rail. NOTE PUSH 1 8-1/4" (209.6) 1 7-1/8" (181.0) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. The Optional Paneline® EL device is designed for electrified access control and is compatible with most key pad and card reader systems. 2 3* SIDELITE CROSSRAIL CROSSRAIL WITH FIXED PANEL PUSH 2 3* 17/32" (13.5) NOTE SIDELITE *VESTIBULE DOOR (Without Exit Device or Lock) INTERIOR VIEW CROSSRAIL WITH EXIT DEVICE AND CPN PULL HANDLE PANELINE® EL COMPONENTS LOCK STILE TRIM FILLER WIDTH VARIES WITH STILE WIDTH DOGGING LOCK (TYPICAL) PUSH 5 7/8" (149.2) © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. ACTIVE DOOR 3'-01/8" (917.8) TO BOTTOM OF DOOR 1'-5 7/8" (454.0) ACTIVE PUSH PANEL FIXED WIDTH PIVOT STILE TRIM FILLER WIDTH VARIES WITH DOOR WIDTH POWER TRANSFER INTERMEDIATE BUTT HINGE POWER TRANSFER INTERMEDIATE OFFSET PIVOT DOOR OPENING WIDTH 4'-0" (1219.2) MAX. - 2'-10 13/32" (873.9) MIN. 3'-0" (914.6) ADA MIN. EXTERIOR VIEW "CPN" PULL AND OPTIONAL CYLINDER GUARD SHOWN kawneer.com ELECTRIC POWER TRANSFER (EPT) SP 1000 POWER SUPPLY 350/500 HEAVY WALLTM ENTRANCES 20 JUNE, 2011 OPTIONS AND ACCESSORIES EC 97911-30 SCALE 3" = 1'-0" 6" CROSSRAIL WITH BEVELED STOPS FOR 1/4" INFILL 8-1/4" CROSSRAIL WITH BEVELED STOPS FOR 1/4" INFILL Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 3-1/2" CROSSRAIL WITH BEVELED STOPS FOR 1/4" INFILL 6" (152.4) 3-1/2" (88.9) 2" (50.8) 2" CROSSRAIL WITH BEVELED STOPS FOR 1/4" INFILL 8-1/4" (209.6) 200-182 200-183 200-184 5/16" (7.9) 200-185 118-070 5/16" CROSSRAIL WITH BEVELED STOPS FOR 1/4" INFILL OPTIONAL SQUARE STOPS FOR 1" INFILL 118-070 5/16" CROSSRAIL WITH SQUARE STOPS FOR 1/4" INFILL 1/2" (13.0) 2-7/32" (56.4) 5/16" (7.9) 069-177 118-070 1/2" (13.0) 069-154 451-098 (TF VG 451) SNAP-IN DOOR STOP 11/16" (17.5) APPLIED DOOR STOP 400-086 (TF VG 450) SNAP-IN DOOR STOP 2-7/32" (56.4) 5/16" CROSSRAIL WITH SQUARE STOPS FOR 1" INFILL 1" (25.4) 10" BOTTOM RAIL APPLIED DOOR STOP kawneer.com © Kawneer Company, Inc., 2011 5/16" (7.9) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10" (254) OPTIONAL SQUARE STOPS FOR 1/4" INFILL 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 THERMAL CHARTS Project Specific U-Factor Example Calculation 30.125" (765.2) (DLO) 75.75" (1924.1) (F.H.) 7'-2" (2184.4) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. (DLO) 3'-4" (1016.0) (F.W.) Example Glass U-Factor = 0.28 Btu/hr • ft2 • °F Total Daylight Opening = 30.125" x 75.75" = 15.85 ft2 Total Projected Area = 3'-4" x 7'-2" = 23.9 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (15.85 ÷ 23.9)100 = 66% System U-factor vs Percent of Glass Area 0.90 0.80 0.75 N © Kawneer Company, Inc., 2011 (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) 0.65 0.60 0.55 0.50 0.49 0.45 0.40 0.35 0.30 0.25 0.20 80 75 70 Percent of Glass Area 65 66% 85 Based on 66% glass and center of glass (COG) U-factor of 0.28 System U-factor is equal to 0.49 Btu/hr • ft2 • °F kawneer.com 60 Btu hr • ft2 • °F System U-factor COG U-factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.70 E IGN PL S M E A D EX OR F T O Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.85 21 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 THERMAL CHARTS 350 (SINGLE DOOR) 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. COG U-factor 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com © Kawneer Company, Inc., 2011 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area System U-factor (BTU/hr·ft2·oF) 22 System VT © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2011 kawneer.com 350/500 HEAVY WALLTM ENTRANCES EC 97911-30 THERMAL CHARTS 350 (SINGLE DOOR) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) 23 24 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance (BTU/hr • ft • °F) 2 0.48 0.83 0.46 0.82 0.44 0.81 0.42 0.81 0.40 0.80 0.38 0.79 0.36 0.78 0.34 0.77 0.32 0.76 0.30 0.75 0.28 0.74 0.26 0.73 0.24 0.72 0.22 0.71 0.20 0.70 0.18 0.69 0.16 0.68 0.14 0.68 0.12 0.67 0.10 0.66 SHGC Matrix 2 350 (SINGLE DOOR) NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960mm wide by 2090mm high (37-3/4" by 82-3/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.43 0.75 0.39 0.70 0.41 0.70 0.36 0.65 0.38 0.65 0.34 0.60 0.36 0.60 0.31 0.55 0.33 0.55 0.29 0.50 0.30 0.50 0.26 0.45 0.28 0.45 0.23 0.40 0.25 0.40 0.21 0.35 0.23 0.35 0.18 0.30 0.20 0.30 0.16 0.25 0.17 0.25 0.13 0.20 0.15 0.20 0.10 0.15 0.12 0.15 0.08 0.10 0.10 0.10 0.05 0.05 0.07 0.05 0.03 kawneer.com © Kawneer Company, Inc., 2011 Overall U-Factor 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 THERMAL CHARTS 350 (PAIR OF DOORS) System U-factor (BTU/hr·ft2·oF) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area COG U-factor 0.47 (2.67) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.32 (1.82) Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com 25 COG SHGC System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) kawneer.com © Kawneer Company, Inc., 2011 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 350/500 HEAVY WALLTM ENTRANCES Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 26 JUNE, 2011 EC 97911-30 350 (PAIR OF DOORS) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 27 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance (BTU/hr • ft • °F) 2 1 Overall U-Factor 4 0.47 0.79 0.46 0.78 0.44 0.77 0.42 0.76 0.40 0.75 0.38 0.74 0.36 0.73 0.34 0.72 0.32 0.71 0.30 0.70 0.28 0.69 0.26 0.68 0.24 0.67 0.22 0.66 0.20 0.65 0.18 0.64 0.16 0.63 0.14 0.62 0.12 0.61 0.10 0.60 SHGC Matrix 2 350 (PAIR OF DOORS) NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1920mm wide by 2090mm high (75-1/2" by 82-3/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.46 0.75 0.42 0.70 0.43 0.70 0.39 0.65 0.40 0.65 0.36 0.60 0.37 0.60 0.34 0.55 0.35 0.55 0.31 0.50 0.32 0.50 0.28 0.45 0.29 0.45 0.25 0.40 0.26 0.40 0.22 0.35 0.23 0.35 0.20 0.30 0.21 0.30 0.17 0.25 0.18 0.25 0.14 0.20 0.15 0.20 0.11 0.15 0.12 0.15 0.08 0.10 0.09 0.10 0.06 0.05 0.07 0.05 0.03 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 THERMAL CHARTS 500 (SINGLE DOOR) 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. COG U-factor 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com © Kawneer Company, Inc., 2011 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area System U-factor (BTU/hr·ft2·oF) 28 System VT © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2011 kawneer.com 350/500 HEAVY WALLTM ENTRANCES EC 97911-30 THERMAL CHARTS 500 (SINGLE DOOR) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) 29 30 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance (BTU/hr • ft • °F) 2 0.48 0.87 0.46 0.86 0.44 0.85 0.42 0.84 0.40 0.84 0.38 0.83 0.36 0.82 0.34 0.81 0.32 0.81 0.30 0.80 0.28 0.79 0.26 0.78 0.24 0.77 0.22 0.77 0.20 0.76 0.18 0.75 0.16 0.74 0.14 0.73 0.12 0.73 0.10 0.72 SHGC Matrix 2 500 (SINGLE DOOR) NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960mm wide by 2090mm high (37-3/4" by 82-3/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.38 0.75 0.33 0.70 0.36 0.70 0.31 0.65 0.34 0.65 0.29 0.60 0.32 0.60 0.27 0.55 0.29 0.55 0.25 0.50 0.27 0.50 0.22 0.45 0.25 0.45 0.20 0.40 0.23 0.40 0.18 0.35 0.21 0.35 0.16 0.30 0.18 0.30 0.13 0.25 0.16 0.25 0.11 0.20 0.14 0.20 0.09 0.15 0.12 0.15 0.07 0.10 0.09 0.10 0.04 0.05 0.07 0.05 0.02 kawneer.com © Kawneer Company, Inc., 2011 Overall U-Factor 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 THERMAL CHARTS 500 (PAIR OF DOORS) System U-factor (BTU/hr·ft2·oF) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area COG U-factor 0.47 (2.67) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.34 (1.93) Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com 31 COG SHGC System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) kawneer.com © Kawneer Company, Inc., 2011 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 350/500 HEAVY WALLTM ENTRANCES Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 32 JUNE, 2011 EC 97911-30 500 (PAIR OF DOORS) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) 350/500 HEAVY WALLTM ENTRANCES JUNE, 2011 EC 97911-30 33 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance (BTU/hr • ft • °F) 2 1 Overall U-Factor 4 0.47 0.82 0.46 0.82 0.44 0.81 0.42 0.80 0.40 0.79 0.38 0.78 0.36 0.77 0.34 0.77 0.32 0.76 0.30 0.75 0.28 0.74 0.26 0.73 0.24 0.72 0.22 0.71 0.20 0.70 0.18 0.70 0.16 0.69 0.14 0.68 0.12 0.67 0.10 0.66 SHGC Matrix 2 500 (PAIR OF DOORS) NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1920mm wide by 2090mm high (75-1/2" by 82-3/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.41 0.75 0.36 0.70 0.38 0.70 0.34 0.65 0.36 0.65 0.32 0.60 0.34 0.60 0.29 0.55 0.31 0.55 0.27 0.50 0.29 0.50 0.24 0.45 0.26 0.45 0.22 0.40 0.24 0.40 0.19 0.35 0.21 0.35 0.17 0.30 0.19 0.30 0.15 0.25 0.17 0.25 0.12 0.20 0.14 0.20 0.10 0.15 0.12 0.15 0.07 0.10 0.09 0.10 0.05 0.05 0.07 0.05 0.02 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com kawneer.com © Kawneer Company, Inc., 2011 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 350/500 HEAVY WALLTM ENTRANCES Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 34 JUNE, 2011 EC 97911-30