350/500 Heavy Wall™ Entrances

350/500 Heavy Wall™ Entrances
Managing Heavy Traffic with
Reliability, Strength and
Protection that Lasts
Kohl Center, University of Wisconsin, Madison, WI
Architects: Hok Sport Facilities Group, Kansas City, MO; Venture Architects, Milwaukee, WI; Heinlein & Schrock, Kansas City, MO
Glazing Contractor: Lurie Glass Company, Milwaukee, WI
HIGH DURABILITY – 350/500 Heavy Wall™
HURRICANE RESISTANT – 350/500 Heavy Wall™ IR
Kawneer’s Medium Stile 350 and Wide Stile 500 Heavy Wall™ Entrance
lines provide quality, durability and protection that lasts. The entrances
were designed for heavy-traffic areas such as schools, universities
and office buildings where traffic and motion create rigorous usage.
350/500 Heavy Wall™ Entrances have 3/16" (4.8 mm) walls throughout
for additional strength and durability, and two framing options to
provide a choice for designers. Additionally, the 350/500 Heavy Wall™
IR Entrances provide a solution for blast mitigation as well as offer
hurricane resistance where they have been tested to meet the highest
level of impact protection for entrances in the industry.
Performance
To resist both lever arm and torsion forces that constantly act upon
any door, all 350/500 Heavy Wall™ Entrances feature four Sigma deep
penetration and fillet welds plus mechanical fastening at each corner.
In addition to the standard two-year warranty covering every Kawneer
door, each door corner for the 350/500 Heavy Wall™ Entrances
comes with a limited lifetime warranty, good for the life of the door
under normal-use operation.
Aesthetics
Like all Kawneer entrances, 350/500 Heavy Wall™ Entrances offer
classic lines and clean aesthetics and can blend into any type
of architecture, whether traditional or modern, remodel or new
construction. The door is 2" (50.8 mm) deep with 3-1/2" (88.9 mm)
vertical stiles for the 350 Heavy Wall™ and 5" (127 mm) vertical stiles
for the 500 Heavy Wall™ with a 6-1/2" (165.1 mm) bottom rail. A
deeper 10-1/4" (260.4 mm) bottom rail is also available. Glazing infills
range from 1/4" to 1" (6.4 mm to 25.4 mm). Muntins are optional and
can be added to complement any design.
350/500 Heavy Wall™ Entrances provide a choice of framing:
Trifab® VG (VersaGlaze®) 450 or 451 with 3/32" (2.4 mm) thickness
for economical applications that do not require additional strength
throughout the entire entrance. Alternatively, the Heavy Wall™
Trifab® VG framing with 3/16" (4.8 mm) wall thickness provides a
solution for applications facing heavier traffic and substantial, or
possibly abusive, usage.
Heavy Wall™ is a single-acting entrance with offset pivots, butt hinges
or continuous geared hinges. The classic lines of 350/500 Heavy
Wall™ Entrances push-pull hardware blend into any design.
Protective Glazing
350/500 Heavy Wall™ IR Entrances
Wind-borne debris, persistent rain and internal/external pressure
changes are major causes of property damage and injury stemming
from violent weather, and building codes in coastal areas often
require enhanced safety for occupants. To meet these needs,
350/500 Heavy Wall™ IR Entrances have been rigorously tested to
meet the forces of nature as well as human directed attacks.
These impact resistant entrances have been tested to meet TAS 201,
202 and 203 requirements of the Florida Building Code (FBC) as well
as Level D requirements of ASTM E 1996. The entrances have also
been tested to meet the even more stringent Level E (Enhanced
Facilities) requirements of ASTM E 1996. For comprehensive safety
assurance, 350/500 Heavy Wall™ IR Entrances have also been tested
for blast mitigation per the requirements of ASTM F 1642.
Montana State Fund Office Building, Helena, MT
Architect: Mosaic Architecture , Helena, MT
Glazing Contractor: Frontline Glass Inc., Helena, MT
For the Finishing Touch
Permanodic® anodized finishes are available in Class I and Class II in
seven different color choices.
Painted finishes, including fluoropolymer, that meet or exceed
AAMA 2605 are offered in many standard choices and an unlimited
number of specially designed colors.
Solvent-free powder coatings add the green element with high
performance, durability and scratch resistance that meet the
standards of AAMA 2604.
Kawneer Company, Inc.
Technology Park / Atlanta
555 Guthridge Court
Norcross, GA 30092
© Kawneer Company, Inc. 2012
kawneer.com
770 . 449 . 5555
LITHO IN U.S.A.
Form No. 12-2146
JUNE, 2011
350/500 HEAVY WALLTM ENTRANCES
FEATURES
Features
• 350 medium stile has 3-1/2" vertical stile, 3-1/2" top and 6-1/2" bottom rail
• 500 wide stile has 5" vertical stile, 5" top and 6-1/2" bottom rail
• Door is 2" deep
• Door has 3/16" wall thickness
• Dual moment welded corner construction
• Single acting
• Offset pivot, butt hinges or continuous geared hinge
• Surface mounted or concealed closers
• MS lock or exit device hardware
• Architects Classic push-pulls
• 1/4", 5/8" or 1" infills
• Adjustable astragal utilizing pile weathering with polymeric fin at meeting stiles
• Sealair® bulb polymeric weatherstripping in door frames
• Permanodic® anodized finishes in seven standard choices
• Painted finishes in standard and custom choices
Optional Features
• Numerous push/pull options
• Paneline® exit device or Paneline® EL exit device
• 3/16" heavy wall frame
Product Applications
• Designed for high traffic applications such as schools, universities and office buildings
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-30
For specific product applications,
Consult your Kawneer representative.
kawneer.com
1
kawneer.com
© Kawneer Company, Inc., 2011
BLANK PAGE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
350/500 HEAVY WALLTM ENTRANCES
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
JUNE, 2011
EC 97911-30
JUNE, 2011
350/500 HEAVY WALLTM ENTRANCES
INDEX
PICTORIAL VIEW................................................................................. 5
350 HEAVY WALL CONSTRUCTION DETAILS................................ 6-9
500 HEAVY WALL CONSTRUCTION DETAILS............................ 10-13
ENTRANCE PACKAGES............................................................... 14,15
ENTRANCE OFFERINGS.............................................................. 16,17
PUSH-PULL HARDWARE / EXIT DEVICES...................................... 18
PANELINE® / PANELINE® EL EXIT DEVICE...................................... 19
OPTIONS AND ACCESSORIES........................................................ 20
THERMAL CHARTS...................................................................... 21-33
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED
ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT
CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR
GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference.
Numbers in parentheses (
) are millimeters unless otherwise noted.
The following metric (SI) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-30
3
Kawneer reserves the right to change configurations without prior notice when deemed necessary
for product improvement.
kawneer.com
kawneer.com
© Kawneer Company, Inc., 2011
BLANK PAGE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
350/500 HEAVY WALLTM ENTRANCES
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
JUNE, 2011
EC 97911-30
JUNE, 2011
350/500 HEAVY WALLTM ENTRANCES
PICTORIAL VIEW
#1 MECHANICAL FASTENING is accomplished
by attaching a 5/16" (7.9) thick extruded aluminum
channel clip to the vertical stile with 1/4"-20 heat
strengthened bolts and 3/16" thick steel nut plates
for a high strength welding base for attachment
horizontal member.
#2 SIGMA* DEEP PENETRATION PLUG WELDS
are made top and bottom after the horizontal
is properly positioned over the channel clip to
help provide the strongest door corner joint
currently available.
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-30
DUAL MOMENT CORNER CONSTRUCTION
* An arc welding process known as Shielded Inert Gas Metal Arc (SIGMA)
or also known as Metal Inert Gas (MIG).
kawneer.com
#3 SIGMA* FILLET WELDS along both top and
bottom webs of the rail extrusion complete the
Dual Moment corner construction.
5
350/500 HEAVY WALLTM ENTRANCES
6
JUNE, 2011
350 HEAVY WALL CONSTRUCTION DETAILS
SCALE 3" = 1'-0"
EC 97911-30
350 HEAVY WALL DOORS
TRIFAB® VG 450 CENTER DOOR FRAMES SHOWN
(HEAVY WALL FRAME OPTIONAL)
7
6 or 6A
1 or 1A
2
1 or 1A
4 or 4A
5
4 or 4A
9
6 or 6A
8 or 8A,8B
8 or 8A,8B
8 or 8A
3 or 3A
1 or 1A
2
1 or 1A
4 or 4A
5
4 or 4A
9
9
3 or 3A
9
450-547
450-547
3
LOCK JAMB
1
HINGE JAMB
2
MEETING STILES
1A
HINGE JAMB
450-499
3A
LOCK JAMB
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
450-499
450-547
4
HINGE JAMB
450-033
6
TRANSOM
INSERT
450-499
4A
HINGE JAMB
450-097
6A
TRANSOM
INSERT
kawneer.com
© Kawneer Company, Inc., 2011
8 or 8A
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
350 HEAVY WALL CONSTRUCTION DETAILS
SCALE 3" = 1'-0"
350 HEAVY WALL DOORS
TRIFAB® VG 450 CENTER DOOR FRAMES SHOWN
(HEAVY WALL FRAME OPTIONAL)
COC WITH SINGLE ACTING OFFSET ARM
7
TRANSOM HEAD
7
TRANSOM HEAD
450-022
STOPS
450-022
STOPS
450-545
450-498
450-022
STOPS
450-079
041-045
8A
DOOR HEADER/
TRANSOM BAR
8
DOOR HEADER/
TRANSOM BAR
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE ACTING DOORS
8B
DOOR HEADER/
TRANSOM BAR
200-799
BOTTOM RAIL
WEATHERING
(OPTIONAL)
069-129
069-129
9*
BOTTOM RAIL
9*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
kawneer.com
200-799
BOTTOM RAIL
WEATHERING
(OPTIONAL)
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
7
350/500 HEAVY WALLTM ENTRANCES
8
JUNE, 2011
350 HEAVY WALL CONSTRUCTION DETAILS
SCALE 3" = 1'-0"
EC 97911-30
350 HEAVY WALL DOORS
TRIFAB® VG 451 CENTER DOOR FRAMES SHOWN
(HEAVY WALL FRAME OPTIONAL)
7
6 or 6A
8 or 8A
1 or 1A
2
1 or 1A
4 or 4A
5
4 or 4A
9
6 or 6A
8 or 8A,8B
8 or 8A,8B
3 or 3A
1 or 1A
2
1 or 1A
4 or 4A
5
4 or 4A
9
9
3 or 3A
9
451-547
451-547
3
LOCK JAMB
1
HINGE JAMB
2
MEETING STILES
1A
HINGE JAMB
451-499
3A
LOCK JAMB
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
451-499
451-547
4
HINGE JAMB
451-026
6
TRANSOM
INSERT
451-499
4A
HINGE JAMB
451-097
6A
TRANSOM
INSERT
kawneer.com
© Kawneer Company, Inc., 2011
8 or 8A
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
350 HEAVY WALL CONSTRUCTION DETAILS
SCALE 3" = 1'-0"
350 HEAVY WALL DOORS
TRIFAB® VG 451 CENTER DOOR FRAMES SHOWN
(HEAVY WALL FRAME OPTIONAL)
COC WITH SINGLE ACTING OFFSET ARM
7
TRANSOM HEAD
7
TRANSOM HEAD
450-022
STOPS
450-022
STOPS
451-498
451-545
450-022
STOPS
451-079
041-045
8A
DOOR HEADER/
TRANSOM BAR
8
DOOR HEADER/
TRANSOM BAR
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE ACTING DOORS
8B
DOOR HEADER/
TRANSOM BAR
200-799
BOTTOM RAIL
WEATHERING
(OPTIONAL)
069-129
069-129
9*
BOTTOM RAIL
9*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
kawneer.com
200-799
BOTTOM RAIL
WEATHERING
(OPTIONAL)
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
9
350/500 HEAVY WALLTM ENTRANCES
10
JUNE, 2011
500 HEAVY WALL CONSTRUCTION DETAILS
SCALE 3" = 1'-0"
EC 97911-30
500 HEAVY WALL DOORS
TRIFAB® VG 450 CENTER DOOR FRAMES SHOWN
(HEAVY WALL FRAME OPTIONAL)
7
6 or 6A
8 or 8A
1 or 1A
2
1 or 1A
4 or 4A
5
4 or 4A
9
6 or 6A
8 or 8A,8B
8 or 8A,8B
8 or 8A
3 or 3A
1 or 1A
2
1 or 1A
4 or 4A
5
4 or 4A
9
9
3 or 3A
9
450-547
450-547
3
LOCK JAMB
1
HINGE JAMB
2
MEETING STILES
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7
450-499
450-499
450-547
4
HINGE JAMB
450-033
6
TRANSOM
INSERT
450-499
4A
HINGE JAMB
450-097
6A
TRANSOM
INSERT
kawneer.com
© Kawneer Company, Inc., 2011
3A
LOCK JAMB
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1A
HINGE JAMB
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
500 HEAVY WALL CONSTRUCTION DETAILS
SCALE 3" = 1'-0"
500 HEAVY WALL DOORS
TRIFAB® VG 450 CENTER DOOR FRAMES SHOWN
(HEAVY WALL FRAME OPTIONAL)
COC WITH SINGLE ACTING OFFSET ARM
7
TRANSOM HEAD
7
TRANSOM HEAD
450-022
STOPS
450-022
STOPS
450-545
450-498
450-022
STOPS
450-079
041-045
8A
DOOR HEADER/
TRANSOM BAR
8
DOOR HEADER/
TRANSOM BAR
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE ACTING DOORS
8B
DOOR HEADER/
TRANSOM BAR
200-799
BOTTOM RAIL
WEATHERING
(OPTIONAL)
069-129
069-129
9*
BOTTOM RAIL
9*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
kawneer.com
200-799
BOTTOM RAIL
WEATHERING
(OPTIONAL)
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
11
350/500 HEAVY WALLTM ENTRANCES
12
JUNE, 2011
500 HEAVY WALL CONSTRUCTION DETAILS
SCALE 3" = 1'-0"
EC 97911-30
500 HEAVY WALL DOORS
TRIFAB® VG 451 CENTER DOOR FRAMES SHOWN
(HEAVY WALL FRAME OPTIONAL)
7
6 or 6A
8 or 8A
8 or 8A
1 or 1A
2
1 or 1A
4 or 4A
5
4 or 4A
3 or 3A
1 or 1A
2
1 or 1A
4 or 4A
5
4 or 4A
9
9
3 or 3A
9
451-547
451-547
3
LOCK JAMB
1
HINGE JAMB
2
MEETING STILES
451-499
451-499
3A
LOCK JAMB
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1A
HINGE JAMB
451-547
4
HINGE JAMB
451-026
6
TRANSOM
INSERT
451-499
4A
HINGE JAMB
451-097
6A
TRANSOM
INSERT
kawneer.com
© Kawneer Company, Inc., 2011
9
6 or 6A
8 or 8A,8B
8 or 8A,8B
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
500 HEAVY WALL CONSTRUCTION DETAILS
SCALE 3" = 1'-0"
500 HEAVY WALL DOORS
TRIFAB® VG 451 CENTER DOOR FRAMES SHOWN
(HEAVY WALL FRAME OPTIONAL)
COC WITH SINGLE ACTING OFFSET ARM
7
TRANSOM HEAD
7
TRANSOM HEAD
450-022
STOPS
450-022
STOPS
451-498
451-545
450-022
STOPS
451-079
041-045
8A
DOOR HEADER/
TRANSOM BAR
8
DOOR HEADER/
TRANSOM BAR
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE ACTING DOORS
8B
DOOR HEADER/
TRANSOM BAR
200-799
BOTTOM RAIL
WEATHERING
(OPTIONAL)
069-129
069-129
9*
BOTTOM RAIL
9*
BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
kawneer.com
200-799
BOTTOM RAIL
WEATHERING
(OPTIONAL)
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
13
SINGLE ACTING DOOR
WITHOUT TRANSOM
3/16"
(4.3)
3/16"
(4.3)
6-1/2"
(165.1)
6-1/2"
(165.1)
1/8"
(3.2)
1/4"
(6.4)
ENTRANCE PACKAGES
SINGLE ACTING DOOR
WITH TRANSOM
kawneer.com
© Kawneer Company, Inc., 2011
3-17/32"
(89.7)
1/8"
(3.2)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DOOR OPENING
FRAME DIMENSION
MASONRY OPENING
3-17/32"
(89.7)
1/4"
(6.4)
350/500 HEAVY WALLTM ENTRANCES
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1/2"
(12.7)
11/16"
(17.5)
1/2"
(12.7)
11/16"
(17.5)
DOOR OPENING
FRAME DIMENSION
MASONRY OPENING
14
JUNE, 2011
EC 97911-30
SCALE 3" = 1'-0"
TRIFAB® VG 450 CENTER DOOR FRAMES SHOWN
(TRIFAB® VG 451 CENTER DOOR FRAMES SIMILAR)
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
15
ENTRANCE PACKAGES
SCALE 3" = 1'-0"
MASONRY OPENING
FRAME DIMENSION
2"
(50.8)
3/32"
(2.4)
1/8"
(3.2)
1/4"
(6.4)
3-9/16"
(90.5)
3-1/2" (typ.)
(88.9)
1/8"
(3.2)
3/32"
(2.4)
1/4"
(6.4)
SINGLE ACTING DOORS
MASONRY OPENING
FRAME DIMENSION
1/8"
(3.2)
DOOR OPENING
1/4"
(6.4)
11/32"
(8.7)
CONTINUOUS HINGE
JAMB
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DOOR OPENING
kawneer.com
Door Opening Dimension
3' 1/2" x 7' 0" (927.1 x 2134)
3' 6" x 7' 0" (1066.8 x 2134)
6' 0" x 7' 0" (1829 x 2134)
STANDARD SIZE TRIFAB® VG 450 CENTER DOOR FRAMES
WITHOUT TRANSOM
Overall Frame Dimension
3' 4" x 7' 1-3/4" (1016 x 2178)
3' 9-1/2" x 7' 1-3/4" (1155.7 x 2178)
6' 3-1/2" x 7' 1-3/4" (1918 x 2178)
Masonry Opening Dimension
3' 4-1/2" x 7' 2" (1028.7 x 2185)
3' 10" x 7' 2" (1168.4 x 2185)
6' 4" x 7' 2" (1930 x 2185)
Door Opening Dimension
Unchanged from above
WITH TRANSOM
Overall Frame Dimension
Add 3' 1-3/4" (959) to above heights
Masonry Opening Dimension
Add 3' 1-3/4" (959) to above heights
Door Opening Dimension
3' 1/2" x 7' 0" (927.1 x 2134)
3' 6" x 7' 0" (1066.8 x 2134)
6' 0" x 7' 0" (1829 x 2134)
STANDARD SIZE TRIFAB® VG 451 CENTER DOOR FRAMES
WITHOUT TRANSOM
Overall Frame Dimension
3' 4" x 7' 1-3/4" (1016 x 2178)
3' 9-1/2" x 7' 1-3/4" (1155.7 x 2178)
6' 3-1/2" x 7' 1-3/4" (1918 x 2178)
Masonry Opening Dimension
3' 4-1/2" x 7' 2" (1028.7 x 2185)
3' 10" x 7' 2" (1168.4 x 2185)
6' 4" x 7' 2" (1930 x 2185)
Door Opening Dimension
Unchanged from above
WITH TRANSOM
Overall Frame Dimension
Add 3' 1-3/4" (959) to above heights
Masonry Opening Dimension
Add 3' 1-3/4" (959) to above heights
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
ENTRANCE OFFERINGS
EC 97911-30
OPTIONAL
Standard sizes shown on Page 15.
Any size up to 4' x 8' (1219 x 2438)
Glass Stops
Beveled glass stops for 3/16" (4.0) or 1/4" (6.4) infill.
Square glass stops for 3/16" (4.0) or 1/4" (6.4) infill.
Also 1" (25.4) infill.
Door Frames
• Trifab® VG 450 Center - 1-3/4" x 4-1/2" (44.5 x 114.3)
for single glazing.
• Trifab® VG 451 Center - 2" x 4-1/2" (50.8 x 114.3)
for double glazing.
• Heavy Wall Trifab® VG 450 Center - (3/16" Wall).
• Heavy Wall Trifab® VG 451 Center - (3/16" Wall).
Push-Pulls
Single Acting:
• Architects Classic Style "CO-9" Pull and "CP-II" Push bar.
• Architects Classic Style "CO-9" Pull and "CP" Push bar.
Single Acting:
• Architects Classic Style "CO-12" Pull and "CP-II"
Push bar.
• Architects Classic Style "CO-12" Pull and "CP"
Push bar.
• Architects Classic Style "CO-9" / "CO-9" Pull.
• Architects Classic Style "CO-12" / "CP-12" Pull.
Door Closers
Single Acting:
•Norton 1601 adjustable or 1601 BF adjustable surface closer
with back-check, and with or without hold-open.
Single Acting:
•LCN 1260 adjustable
•LCN 4040 surface closer with or without adjustable
hold-open.
•Standard COC with single acting offset arm.
•Norton 8100 surface closer with 50% spring power
adjustment (for opening forces of less than 8 pounds.)
Closer is available with standard back-checks and with
or without the hold-open feature.
•Door-O-Matic/Falcon SC 60 surface closer.
Pivots / Butts
Single Acting:
•Kawneer top and bottom offset pivots.
•Kawneer top and bottom 4-1/2" x 4" (114.3 x 101.6)
ball bearing butt hinge with non-removable pin (NRP).
•Continuous Hinge.
Intermediate
Pivots / Butts
Single Acting:
•Kawneer optional intermediate pivot.
•Kawneer 4-1/2" x 4" (114.3 x 101.6) ball bearing butt
hinge with non-removable pin (NRP).
Note: Offset Pivots are not available for use with Heavy
Wall Frames.
Power Transfers
Single Acting:
•Kawneer optional intermediate pivot with wire transfer.
•Kawneer standard (4-1/2" x 4") (114.3 x 101.6) ball bearing
(NRP) butt hinge with wire transfer.
•EPT (Electric Power Transfer)
Power Supply
•SP 1000 Power Supply
Locks
(Active Leaf)
Adams-Rite MS 1850A Deadlock with two 1-5/32" (29.4)
diameter 5 pin cylinders.
• Adams-Rite #4510 Latch Lock.
• Adams-Rite #1850A-500 Short throw Deadlock.
• Adams-Rite #1850A-505 Hookbolt Lock.
• Adams-Rite #4015 Two-point Lock.
• Adams-Rite #4085 Three-point Lock.
• Adams-Rite #4089 Exit Indicator.
• Kawneer Cylinder Guard.
• Kawneer Thumbturn (in lieu of cylinder).
kawneer.com
© Kawneer Company, Inc., 2011
Door Sizes
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
STANDARD
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
16
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-30
17
ENTRANCE OFFERINGS
STANDARD
OPTIONAL
Locks
(Inactive Leaf)
One pair of Kawneer flush bolts in the inactive leaf of a pair
of doors.
Controller® 3-point locking system consisting of a two point
locking device in the inactive leaf in lieu of flush bolts, working
in conjunction with the MS 1850A deadlock in the active leaf.
This combination provides for greater security than possible
with flush bolts and complies with the life safety considerations
of building codes which prohibit the use of flush bolts.
Threshold
A 1/2" x 4" (12.7 x 101.6) aluminum mill finish threshold.
Weathering
SEALAIR ® Weathering system in the door and frame
consisting of a dense, bulb polymeric material, which remains
resilient and retains its weathering ability under temperature
extremes. (The system is complete with an optional EPDM
blade gasket sweep strip applied to the bottom door rail with
concealed fasteners.)
Bottom Door Sweep
Exit Devices
•Kawneer 1686 concealed rod exit device with
or without a rim type cylinder.
•Paneline® is a concealed rod exit device applicable to
single or pairs of doors. It features an activating panel
contained within the door crossrail.
•Kawneer 1786 rim type exit device with or
without a rim type cylinder.
•Paneline® EL is a concealed rod exit device applicable
to single or pairs of doors. The device is designed for
electrified access control and is compatible with most
key pad and card reader systems.
•Dor-O-Matic/Falcon 1490 is a concealed rod exit device
with or without a rim type cylinder.
•Dor-O-Matic/Falcon 1590 is a rim type exit device with
or without a rim type cylinder.
•Dor-O-Matic/Falcon 1790 rim type exit device with or
without a rim type cylinder.
•Dor-O-Matic/Falcon EL 1690 concealed rod exit device
with or without a rim type cylinder. The device is designed
for electrified access control and is compatible with most
key pad and card reader systems.
•Dor-O-Matic/Falcon EL 1790 rim type exit device with or
without a rim type cylinder. The device is designed for
electrified access control and is compatible with most key
pad and card reader systems.
•Dor-O-Matic/Falcon 1990 is a concealed rod exit device
with or without a rim type cylinder.
•Dor-O-Matic/Falcon 2090 is a rim type exit device with
or without a rim type cylinder.
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
•Dor-O-Matic/Falcon 1690 concealed rod exit device with
or without a rim type cylinder.
Exit Device Pulls
Exit Device Pulls
•Architects Classic style "CO-9" Pull.
•Architects Classic style "CPN" Pull for Paneline® and
Paneline® EL exit devices.
•Architects Classic style "CO-12" Pull
(except for Paneline® and Paneline® EL exit devices).
Reference Hardware section for additional information
kawneer.com
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
PUSH-PULL HARDWARE / EXIT DEVICES
EC 97911-30
ARCHITECTS CLASSIC (PUSH-PULL SETS)
Refer to HARDWARE SECTION for
complete hardware information.
SINGLE ACTING DOORS USE A PULL HANDLE AND PUSH BAR.
CP-II / CP-II
CO-9 / CP
CO-12 / CP
CO-9 / CP-II
CO-12 / CP-II
CP / CP
CO-9 / CO-9
CO-12 / CO-12
ARCHITECTS CLASSIC (COMPONENTS)
"CO-9"
PULL
"CO-12"
PULL
"CP-II" PUSH BAR
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
18
"CP" PUSH BAR
RIM LATCH EXIT DEVICE
Kawneer 1786
"CO-9"
PULL
CONCEALED ROD EXIT DEVICE
Dor-O-Matic/Falcon 1990
"CO-12"
PULL
CONCEALED ROD EXIT DEVICE
Dor-O-Matic/Falcon 1690
Dor-O-Matic/Falcon EL 1690
RIM LATCH EXIT DEVICE
Dor-O-Matic/Falcon 1790
Dor-O-Matic/Falcon EL 1790
RIM LATCH EXIT DEVICE
Dor-O-Matic/Falcon 2090
kawneer.com
© Kawneer Company, Inc., 2011
CONCEALED ROD EXIT DEVICE
Kawneer 1686
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
EXIT DEVICES and EXIT DEVICE PULLS
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
19
PANELINE® / PANELINE® EL EXIT DEVICE
PANELINE® EXIT DEVICE
SCALE 3" = 1'-0"
The Paneline® concealed rod exit device will accommodate variations in door width as shown in the following
illustrations. Sidelites adjacent to Paneline equipped doors not requiring exit devices may be fitted with fixed panels
as detailed below to match the general appearance of the Paneline cross rail.
See Hardware Section for complete description of Paneline hardware, including finish of units.
Paneline uses mortise cylinder in lieu of the normal rim-type.
Dummy Paneline units should not use any type of lock.
2"
(50.8)
INTERIOR ELEVATIONS
1-1/8"
(27.8)
1/8"
(3.2)
NOTE: Sidelites must be stop glazed above and below rail.
NOTE
PUSH
1
8-1/4"
(209.6)
1
7-1/8"
(181.0)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
The Optional Paneline® EL device is designed for electrified access control and is compatible with most key pad
and card reader systems.
2
3*
SIDELITE
CROSSRAIL
CROSSRAIL
WITH FIXED
PANEL
PUSH
2
3*
17/32"
(13.5)
NOTE
SIDELITE
*VESTIBULE DOOR
(Without Exit Device or Lock)
INTERIOR VIEW
CROSSRAIL
WITH EXIT DEVICE
AND CPN PULL HANDLE
PANELINE® EL COMPONENTS
LOCK STILE TRIM FILLER WIDTH
VARIES WITH STILE WIDTH
DOGGING LOCK
(TYPICAL)
PUSH
5 7/8"
(149.2)
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
ACTIVE
DOOR
3'-01/8"
(917.8)
TO BOTTOM
OF DOOR
1'-5 7/8" (454.0)
ACTIVE PUSH PANEL
FIXED WIDTH
PIVOT STILE TRIM FILLER WIDTH
VARIES WITH DOOR WIDTH
POWER TRANSFER
INTERMEDIATE BUTT HINGE
POWER TRANSFER
INTERMEDIATE OFFSET PIVOT
DOOR OPENING WIDTH
4'-0" (1219.2) MAX. - 2'-10 13/32" (873.9) MIN.
3'-0" (914.6) ADA MIN.
EXTERIOR VIEW
"CPN" PULL AND OPTIONAL
CYLINDER GUARD SHOWN
kawneer.com
ELECTRIC POWER TRANSFER
(EPT)
SP 1000 POWER SUPPLY
350/500 HEAVY WALLTM ENTRANCES
20
JUNE, 2011
OPTIONS AND ACCESSORIES
EC 97911-30
SCALE 3" = 1'-0"
6" CROSSRAIL
WITH BEVELED STOPS
FOR 1/4" INFILL
8-1/4" CROSSRAIL
WITH BEVELED STOPS
FOR 1/4" INFILL
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
3-1/2" CROSSRAIL
WITH BEVELED STOPS
FOR 1/4" INFILL
6"
(152.4)
3-1/2"
(88.9)
2"
(50.8)
2" CROSSRAIL
WITH BEVELED STOPS
FOR 1/4" INFILL
8-1/4"
(209.6)
200-182
200-183
200-184
5/16"
(7.9)
200-185
118-070
5/16" CROSSRAIL
WITH BEVELED STOPS
FOR 1/4" INFILL
OPTIONAL SQUARE STOPS
FOR 1" INFILL
118-070
5/16" CROSSRAIL
WITH SQUARE STOPS
FOR 1/4" INFILL
1/2"
(13.0)
2-7/32"
(56.4)
5/16"
(7.9)
069-177
118-070
1/2"
(13.0)
069-154
451-098
(TF VG 451)
SNAP-IN DOOR STOP
11/16"
(17.5)
APPLIED DOOR STOP
400-086
(TF VG 450)
SNAP-IN DOOR STOP
2-7/32"
(56.4)
5/16" CROSSRAIL
WITH SQUARE STOPS
FOR 1" INFILL
1"
(25.4)
10" BOTTOM RAIL
APPLIED DOOR STOP
kawneer.com
© Kawneer Company, Inc., 2011
5/16"
(7.9)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
10"
(254)
OPTIONAL SQUARE STOPS
FOR 1/4" INFILL
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
THERMAL CHARTS
Project Specific U-Factor Example Calculation
30.125"
(765.2)
(DLO)
75.75"
(1924.1)
(F.H.)
7'-2"
(2184.4)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
(DLO)
3'-4"
(1016.0)
(F.W.)
Example Glass U-Factor = 0.28 Btu/hr • ft2 • °F
Total Daylight Opening
= 30.125" x 75.75" = 15.85 ft2
Total Projected Area
= 3'-4" x 7'-2" = 23.9 ft2
Percent of Glass
= (Total Daylight Opening ÷ Total Projected Area)100
= (15.85 ÷ 23.9)100 = 66%
System U-factor vs Percent of Glass Area
0.90
0.80
0.75
N
© Kawneer Company, Inc., 2011
(2.73)
(2.61)
(2.50)
(2.39)
(2.27)
(2.16)
(2.05)
(1.93)
(1.82)
(1.71)
(1.59)
(1.48)
(1.37)
(1.25)
(1.14)
0.65
0.60
0.55
0.50
0.49
0.45
0.40
0.35
0.30
0.25
0.20
80
75
70
Percent of Glass Area
65
66%
85
Based on 66% glass and center of glass (COG) U-factor of 0.28
System U-factor is equal to 0.49 Btu/hr • ft2 • °F
kawneer.com
60
Btu
hr • ft2 • °F
System U-factor
COG
U-factor
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.70
E IGN
PL S
M E
A D
EX OR
F
T
O
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.85
21
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
THERMAL CHARTS
350 (SINGLE DOOR)
0.48 (2.73)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
COG
U-factor
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
Percent of Glass = Vision Area/Total Area
(Total Daylight Opening / Projected Area)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
kawneer.com
© Kawneer Company, Inc., 2011
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
System U-factor (BTU/hr·ft2·oF)
22
System VT
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JUNE, 2011
kawneer.com
350/500 HEAVY WALLTM ENTRANCES
EC 97911-30
THERMAL CHARTS
350 (SINGLE DOOR)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
23
24
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Thermal Transmittance (BTU/hr • ft • °F)
2
0.48
0.83
0.46
0.82
0.44
0.81
0.42
0.81
0.40
0.80
0.38
0.79
0.36
0.78
0.34
0.77
0.32
0.76
0.30
0.75
0.28
0.74
0.26
0.73
0.24
0.72
0.22
0.71
0.20
0.70
0.18
0.69
0.16
0.68
0.14
0.68
0.12
0.67
0.10
0.66
SHGC Matrix 2
350 (SINGLE DOOR)
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values
(winter conditions) and are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 960mm wide by
2090mm high (37-3/4" by 82-3/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.43
0.75
0.39
0.70
0.41
0.70
0.36
0.65
0.38
0.65
0.34
0.60
0.36
0.60
0.31
0.55
0.33
0.55
0.29
0.50
0.30
0.50
0.26
0.45
0.28
0.45
0.23
0.40
0.25
0.40
0.21
0.35
0.23
0.35
0.18
0.30
0.20
0.30
0.16
0.25
0.17
0.25
0.13
0.20
0.15
0.20
0.10
0.15
0.12
0.15
0.08
0.10
0.10
0.10
0.05
0.05
0.07
0.05
0.03
kawneer.com
© Kawneer Company, Inc., 2011
Overall U-Factor 4
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
THERMAL CHARTS
350 (PAIR OF DOORS)
System U-factor (BTU/hr·ft2·oF)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
COG
U-factor
0.47 (2.67)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.32 (1.82)
Percent of Glass = Vision Area/Total Area
(Total Daylight Opening / Projected Area)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
kawneer.com
25
COG
SHGC
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
kawneer.com
© Kawneer Company, Inc., 2011
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
350/500 HEAVY WALLTM ENTRANCES
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
26
JUNE, 2011
EC 97911-30
350 (PAIR OF DOORS)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
27
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Thermal Transmittance (BTU/hr • ft • °F)
2
1
Overall U-Factor 4
0.47
0.79
0.46
0.78
0.44
0.77
0.42
0.76
0.40
0.75
0.38
0.74
0.36
0.73
0.34
0.72
0.32
0.71
0.30
0.70
0.28
0.69
0.26
0.68
0.24
0.67
0.22
0.66
0.20
0.65
0.18
0.64
0.16
0.63
0.14
0.62
0.12
0.61
0.10
0.60
SHGC Matrix 2
350 (PAIR OF DOORS)
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values
(winter conditions) and are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1920mm wide by
2090mm high (75-1/2" by 82-3/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.46
0.75
0.42
0.70
0.43
0.70
0.39
0.65
0.40
0.65
0.36
0.60
0.37
0.60
0.34
0.55
0.35
0.55
0.31
0.50
0.32
0.50
0.28
0.45
0.29
0.45
0.25
0.40
0.26
0.40
0.22
0.35
0.23
0.35
0.20
0.30
0.21
0.30
0.17
0.25
0.18
0.25
0.14
0.20
0.15
0.20
0.11
0.15
0.12
0.15
0.08
0.10
0.09
0.10
0.06
0.05
0.07
0.05
0.03
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
THERMAL CHARTS
500 (SINGLE DOOR)
0.48 (2.73)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
COG
U-factor
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
Percent of Glass = Vision Area/Total Area
(Total Daylight Opening / Projected Area)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
kawneer.com
© Kawneer Company, Inc., 2011
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
System U-factor (BTU/hr·ft2·oF)
28
System VT
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JUNE, 2011
kawneer.com
350/500 HEAVY WALLTM ENTRANCES
EC 97911-30
THERMAL CHARTS
500 (SINGLE DOOR)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
29
30
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Thermal Transmittance (BTU/hr • ft • °F)
2
0.48
0.87
0.46
0.86
0.44
0.85
0.42
0.84
0.40
0.84
0.38
0.83
0.36
0.82
0.34
0.81
0.32
0.81
0.30
0.80
0.28
0.79
0.26
0.78
0.24
0.77
0.22
0.77
0.20
0.76
0.18
0.75
0.16
0.74
0.14
0.73
0.12
0.73
0.10
0.72
SHGC Matrix 2
500 (SINGLE DOOR)
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values
(winter conditions) and are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 960mm wide by
2090mm high (37-3/4" by 82-3/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.38
0.75
0.33
0.70
0.36
0.70
0.31
0.65
0.34
0.65
0.29
0.60
0.32
0.60
0.27
0.55
0.29
0.55
0.25
0.50
0.27
0.50
0.22
0.45
0.25
0.45
0.20
0.40
0.23
0.40
0.18
0.35
0.21
0.35
0.16
0.30
0.18
0.30
0.13
0.25
0.16
0.25
0.11
0.20
0.14
0.20
0.09
0.15
0.12
0.15
0.07
0.10
0.09
0.10
0.04
0.05
0.07
0.05
0.02
kawneer.com
© Kawneer Company, Inc., 2011
Overall U-Factor 4
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
THERMAL CHARTS
500 (PAIR OF DOORS)
System U-factor (BTU/hr·ft2·oF)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
COG
U-factor
0.47 (2.67)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.34 (1.93)
Percent of Glass = Vision Area/Total Area
(Total Daylight Opening / Projected Area)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
kawneer.com
31
COG
SHGC
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
kawneer.com
© Kawneer Company, Inc., 2011
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
350/500 HEAVY WALLTM ENTRANCES
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
32
JUNE, 2011
EC 97911-30
500 (PAIR OF DOORS)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
350/500 HEAVY WALLTM ENTRANCES
JUNE, 2011
EC 97911-30
33
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Thermal Transmittance (BTU/hr • ft • °F)
2
1
Overall U-Factor 4
0.47
0.82
0.46
0.82
0.44
0.81
0.42
0.80
0.40
0.79
0.38
0.78
0.36
0.77
0.34
0.77
0.32
0.76
0.30
0.75
0.28
0.74
0.26
0.73
0.24
0.72
0.22
0.71
0.20
0.70
0.18
0.70
0.16
0.69
0.14
0.68
0.12
0.67
0.10
0.66
SHGC Matrix 2
500 (PAIR OF DOORS)
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values
(winter conditions) and are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1920mm wide by
2090mm high (75-1/2" by 82-3/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.41
0.75
0.36
0.70
0.38
0.70
0.34
0.65
0.36
0.65
0.32
0.60
0.34
0.60
0.29
0.55
0.31
0.55
0.27
0.50
0.29
0.50
0.24
0.45
0.26
0.45
0.22
0.40
0.24
0.40
0.19
0.35
0.21
0.35
0.17
0.30
0.19
0.30
0.15
0.25
0.17
0.25
0.12
0.20
0.14
0.20
0.10
0.15
0.12
0.15
0.07
0.10
0.09
0.10
0.05
0.05
0.07
0.05
0.02
© Kawneer Company, Inc., 2011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
kawneer.com
© Kawneer Company, Inc., 2011
BLANK PAGE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
350/500 HEAVY WALLTM ENTRANCES
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
34
JUNE, 2011
EC 97911-30